Air Changes Certification - STL

Awarded Award Notice Posted

Solicitation number
VA25517Q0096
Agency
Veterans Integrated Service Network 15 Veterans Health Administration, Department of Veterans Affairs
Awarded
to Walter Mechanical Services Inc.
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Contract number
VA25517C0036 Federal contract award
NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
Not on record
Place of performance
St. Louis VA Health Care System John Cochran Division 915 North Grand Blvd. St. Louis, MO 63106 USA

Notice details come from SAM.gov. Updated .

Notice text

Added: Dec 02, 2016 2:45 pm Page 3 of 3



THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR A PROPOSAL OR QUOTE. THE VA IS NOT SEEKING PRICING OR OFFERS.



This is a Request for Information (RFI)/Sources Sought Notice, issued in accordance with FAR 15.201(e), to conduct market research. This RFI/Sources Sought Notice is issued solely for information and planning purposes. It does not constitute either a Request for Quotation (RFQ) or a Request for Proposal (RFP); nor is it a promise to issue a RFQ/RFP in the future. This RFI/Sources Sought Notice does not commit the Government to contract for any supply or service whatsoever. The Department of Veterans Affairs (VA) is not seeking proposals at this time, and will not accept any unsolicited proposals. Responders, and not the Government, will pay for any costs incurred while responding to this RFI/Sources Sought Notice. Vendors who don t respond to this RFI/Sources Sought Notice may still participate in any future RFQ/RFP. Information submitted in response to this RFI/Sources Sought Notice is strictly voluntary and becomes the property of the Government. The Government may modify this announcement in the future, as information changes.



This RFI/Sources Sought Notice is market research to help the Department of Veterans Affairs make acquisition decisions. The VA Heartland Network Contracting Office (NCO) 15 is looking for VETBIZ VIP verified SDVOSB and VOSB concerns registered under the NAICS code of 238220 (Plumbing, Heating, and Air-Conditioning Contractors) in both VETBIZ and SAM that are capable of performing Air Changes per hour (ACH) testing in HVAC systems, as described below.



DESCRIPTION OF SERVICES:

Perform air duct testing and calculate Air Changes per hour (ACH) in the HVAC systems in buildings 1 and 2 on the St. Louis Health Care System campus, John Cochran Division, 915 North Grand Blvd., St. Louis, MO 63106. Test all HVAC systems and components in the defined spaces and verify that test results are within acceptable tolerances. The test is required for annual certification.



CONTRACT OBJECTIVE:

The purpose of determining the ventilation rate calculated as Air Changes per hour, or air change rate, abbreviated ACH or ac/h - is to measure:



the air volume added to or removed from a space, or how many times the air within a defined space is replaced per hour;

duct leakage, or airtightness;

pressure differentials; and

maximum ACH required to prevent (or control) condensation.



The test shall include: 1) measurement of airflow and pressure relationships in all the defined spaces; 2) measurement of fresh air changes per hour; 3) total air changes per hour; and 4) pressure relationship to adjacent areas.

The Contractor shall identify the deficiencies in the areas that don t meet current VA and industry standards, and recommend solutions to correct those deficiencies.

The Contractor shall submit a detailed report to VA Engineering no later than two weeks after the testing is completed. The Ventilation Rate (or ACH) Report shall include the following information: A. Report Title; B. Report Certification; C. Table of Contents; D. Report Summary/Remarks; E. Appropriate Forms; F. Instrument Calibration; and G. Abbreviations. The report shall accurately represent the system measurements obtained in accordance with the current edition of the NEBB or AABC Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems. The report shall note any variances from design quantities, which exceed NEBB or AABC tolerances. The report shall clearly spell out any deficiencies uncovered, such as: 1) air and hydronic measurements on the HVAC systems; 2) total air changes and fresh air changes per hour; 3) pressure differentials, as measured in inches of water (iwc). The report shall also recommend solutions to fix the deficiencies in the areas where the air flow and pressure relationship is out of tolerance. And the report shall include notes and comments, as appropriate, to provide VA Engineering with additional details related to the test procedure, system operation and results. VA Engineering will provide the room by room benchmarks for the ACH rates. Nevertheless, ACH rates may change at any time, depending on revisions to VHA Directives and VA Office of Construction & Facilities Management Design Manuals.



CONTRACTOR REQUIREMENTS:

Testing and certification shall be in accordance with ASHRAE 170-2013 (Addendum k), and the design requirements of the existing HVAC system.

The Contractor shall provide all the labor, supervision, material, and instruments required to perform the air changes testing on the HVAC systems and components.

Air duct testing to calculate the Air Changes per Hour (ACH) shall be performed by an accredited Testing, Adjusting and Balancing Bureau (TABB) certified Contractor.

After each test the Contractor shall submit the test results to VA Engineering.

The Contractor must hold a valid Class A Air Conditioning and Refrigeration Contractor s (ACR) license with a code E endorsement.

The supervisor should be a TABB supervisor, and the technicians should be TABB technicians.

The Contractor shall provide all necessary Personal Protective Equipment (PPE) for his (or her) employees.



GENERAL INFORMATION:

The intended contract period of performance is one year, with options for renewal.



The assigned NAICS code is: 238220 (Plumbing, Heating, and Air-Conditioning Contractors) and the small business size standard is $15.0 Million.



The Government is not soliciting offers at this time, and it will be the Contracting Officer who will determine which suggested changes are accepted. This is a RFI/Sources Sought Notice only, to gain knowledge of potential qualified sources. A solicitation is not currently available.



Responses to this request will be considered for the purpose of determining how the requirements will be stated and how the procurement will be conducted. This RFI/Sources Sought Notice is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or to award a contract. No reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow-up information requests.



If you are interested and are capable of providing the required services, please complete the sources sought questionnaire below and email your response to paul.landry@va.gov no later than 2:00:00 PM CST on 9 December 2016. Include any comments or questions you may have. Also provide your capability statements with your response.



SPECIFIC RESPONSE INSTRUCTIONS



RFI/Sources Sought Notice response (capability statement) should be no more than 5 pages.

Mark your response Proprietary Information if the information is considered business sensitive.

State what class of Air Conditioning and Refrigeration Contractor s (ACR) license held, and code endorsement.

4. State whether supervisor and technicians are TABB-certified.

State whether SDVOSB or VOSB is verified in VETBIZ VIP and registered in SAM under NAICS code 238220 in SAM and VETBIZ.



A SOURCES SOUGHT QUESTIONNAIRE is below. Responses to the Questionnaire are encouraged from all interested parties. You are advised that providing responses to the questions will not automatically include you in the acquisition process for this solicitation. Please provide any additional feedback in your response that you feel is relevant.



Source Sought Questionnaire:



Company Name ___________________________________________



Phone Number ____________________________________________



Email Address ____________________________________________



DUNS ______________________



* Proof of Systems for Award Management Registration (SAM) is mandatory*



1. GSA Number if applicable_________________________________



2. Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program. The North American Industry Classification System (NAICS) code is tentatively 238220, Plumbing, Heating, and Air-Conditioning Contractors; the small business size standard for this NAICS code is $15.0 Million.



A size standard, which is usually stated in number of employees or average annual receipts, represents the largest size that a business (including its subsidiaries and affiliates) may be to remain classified as a small business for Small Business Administration and federal contracting programs. The definition of "small" varies by industry.



[ ] yes [ ] no Small Business (SB)



[ ] yes [ ] no HUBZone



[ ] yes [ ] no Small Business 8(a)



[ ] yes [ ] no Small Disadvantaged Business (SDB)



[ ] yes [ ] no Economically-Disadvantaged Women-Owned Small Business



(EDWOSB)



[ ] yes [ ] no Women-Owned (WO) Small Business



[ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB)



[ ] yes [ ] no Other (please specify)





3. In your opinion, what are the risks associated with this effort? Comment on any current or potential technical, cost, schedule, or performance risks that you would like to make the Government aware of that concerns this service.



4. Provide any additional feedback that you feel is relevant (i.e., problems or any other issues experienced with similar contracts).



Note: Do not include Proprietary, classified, confidential, or sensitive information in your responses.

Attachments

Files attached to this notice, newest first
File Type Posted
VA255-17-Q-0096-A00002000.docx DOCX document
VA255-17-Q-0096-A00001000.docx DOCX document
VA255-17-Q-0096-001.docx DOCX document
VA255-17-Q-0096-002.pdf PDF
VA255-17-Q-0096-000.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Air Changes Certification - STL Latest Award Notice
Air Changes Certification - STL This notice · Original Award Notice

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity