AE Design Repair Structural Columns at the Thunder Dome (B1140)
Awarded Award Notice Posted
- Solicitation number
- FA500418RD007
- Agency
- Pacific Air Forces Air Force, Department of Defense
- Awarded
- to Design Alaska, Inc.
- Set-aside
- Total Small Business
Opportunity facts
- Contract number
- FA5004-18-C-C015 Federal contract award
- NAICS code
- 541330 Engineering Services
- PSC
- Not on record
- Place of performance
- Bldg 1140 Eielson AFB, Alaska 99702, United States
Notice details come from SAM.gov. Updated .
Notice text
Added: Feb 07, 2018 6:33 pm
ARCHITECT-ENGINEERING (A-E) SERIVCES AT EIELSON AFB, AK
"Notice to Offerors/Supplier(s): Funds are not presently available for this effort. No award will be made under this solicitation until funds are available. The Government reserves the right to cancel this solicitation, either before or after the closing date for receipt of proposals. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any costs."
The 354th Contracting Squadron is seeking qualification packages and past performance information from vendors interested in providing professional architect and engineering services at Eielson AFB, AK to design repair of the structural columns of the Thunder Dome (B1140), Project FTQW 14-1002.
BACKGROUND: The Thunder Dome Hangar B1140, is a 300' x 300' concrete structure that servers as the primary heavy aircraft support hangar for REDFLAG-Alaska. This building, constructed in the early 1950's, is a concrete structure supported with multiple buttresses. The building houses numerous offices and conference rooms along the two-story East and West sides of the building. Some of the support elements on each corner of the building are failing and show evidence of severe concrete damage.
This is a competitive selection process in which competing offerors' qualifications will be evaluated in accordance with (IAW) FAR Part 36.6 to determine the most highly qualified firms. The Government intends to award one Firm Fixed-Price contract.
IAW FAR 36.603(b): To be considered for architect-engineer contracts, a firm must file with the appropriate office or board the Standard Form 330, "Architect-Engineer Qualifications," Part II and when applicable, SF 330, Part I. Responders are advised that the Government will not pay for any information or administrative costs incurred in response to this posting; all costs associated with responding will be solely at the interested parties' expense. Failure to respond to this post does not preclude participation in the subsequent technical evaluation so long as a firm's SF 330 is currently on file with the 354th Contracting Squadron. It is the responsibility of the potential offerors to monitor these sites for additional information pertaining to this requirement.
This acquisition will be a 100% Small Business set-aside. The NAICS 541330 (Engineering Services) applies to this acquisition, with a small business size standard of $15M. The Disclosure of Magnitude for the subsequent construction project is between $500,000 and $1,000,000, IAW FAR 36.204(e).
The work to be performed shall include:
1. Attending a pre-investigation meeting
2. Investigating site conditions, options, etc.
3. Collecting and reviewing project data and records
4. Developing design concepts and cost estimates
5. Submitting an investigation report
6. Attending review meetings
7. Making the revisions requested by the Government
8. Submitting intermediate design documents
9. Producing a complete design (65%, 95% and 100% submissions)
A-E EXPERIENCE REQUIREMENTS: A-E's experience shall include that which is commensurate with the requirements specific to the scope of the design.
A. The offeror's team shall include staff members licensed in the State of Alaska in the following disciplines:
• Structural Engineer
B. In addition, offerors shall demonstrate their qualification for the following:
• Project/Program Manager
• Environmental Engineer (hazmat)
• Industrial Hygienist (certified)
• Cost Estimator
The scope of the investigation and design shall include the full repairs to the structural elements at each corner of the hangar that show evidence of failure. Include architectural including maintaining a building envelope that is appropriate to the sub-arctic environment, structural upgrades if required.
The Air Force requires complete and functional designs that are appropriate for the sub-arctic environment of interior Alaska and that meet all applicable Federal, State, Local, Industry,
U.S. Air Force and Eielson AFB requirements.
The A-E shall be responsible for all travel and lodging arrangements and expenses involved in the performance of work under this contract. The A-E shall furnish the Air Force with complete and usable products to include: planning documents, investigative reports, study reports, design analyses, project drawings, technical provisions (specifications), equipment layouts, cost estimates, submittal registers, quality assurance plans, constructability review reports, construction bidding amendments, construction contract modifications, and other documents.
QUESTIONS: All questions regarding this synopsis must be submitted in writing no later than 21 Feb 2018.
Primary POC email: rebecca.hartupee@us.af.mil
Alternate POC email: tanya.gutka@us.af.mil
Attachments
| File | Type | Posted |
|---|---|---|
| Attach_5_-_PPQ.pdf | ||
| Attach_4_-_SF330.pdf | ||
| Attach_6_-_AMRDEC_Guide.pdf | ||
| Attach_1_-_Instructions_to_Offerors.pdf | ||
| Attach_3_-_SOW_7Feb18.pdf | ||
| Attach_2_-_Evaluation_Factors.pdf |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity