667-17-3-132-0429 -MapCheck2 - VA256-17-AP-6536

Awarded Award Notice Posted

Solicitation number
VA25617Q0721
Agency
Veterans Integrated Service Network 6 Veterans Health Administration, Department of Veterans Affairs
Awarded
to Sun Nuclear Corp.
Set-aside
No set-aside

Opportunity facts

Contract number
VA256-17-P-1033 Federal contract award
NAICS code
334519 Other Measuring and Controlling Device Manufacturing
PSC
Not on record

Notice details come from SAM.gov. Updated .

Notice text

Added: May 13, 2017 9:05 am This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), Hub-Zone and other Small Businesses interested and capable of providing items requested, as well as any large businesses . Responses to this notice shall include the following: (a) company name b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUB-Zone, Women Owned Small Business, Small disadvantaged business, or Small Business HUB-Zone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. A solicitation is not currently available. If a solicitation is issued, it will be announced on Federal Business opportunities website http://www.fbo.gov at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement.



This notice is seeking Brand Name or Equal equipment (manufacturer is Sun Nuclear). NEW equipment ONLY - no remanufactured or gray market equipment. Equipment must be covered under manufacturer s warranty.

The North American Industry Classification System (NAICS) Code for this acquisition is 334519, Size Standard: 500 Employees, and the Classification code is 6515. All information is to be submitted at no cost or obligation to the Government.



Description:



The Government is interested in gaining knowledge of potential businesses that would be able to distribute or manufacture MapCheck2 (MC@) device and associated software necessary for conducting quality assurance on patient treatment plans prior to treatment to the Overton Brooks VA Medical Center in Shreveport, LA. The MC2 is used to perform patient intensity Modulated radiation Therapy and Image Guided Radiation Therapy Quality Assurance (IMRT/IGRT QAs). The MC2 will also be used for Linear Accelerator (LINAC) quality assurance of light vs radiation field, beam steering and output checks on a monthly and annual basis. The current plans IMRT/IGRT and future SRS/SBRT require a high degree of precision and proper transference to the LINAC to be delivered correctly without issues.

BRAND NAME OR EQUAL



Brand Name: Sun Nuclear MapCheck 2

Part # Description - QTY 1 each



0001 - 1177000-0Z: MapCHECK® 2 - A 1527 channel 2-Dimensional real time diode array with PC software interface. Included software interfaces with treatment planning system to import calculated dose file for comparison to measured dose file. Field size of 26cm x 32cm with uniform 7mm spacing. Includes case, 25 meter power-data cable, USB cable, power supply (110/220 V), and 1 year of hardware and 1 year of software maintenance. See product datasheet for minimum PC requirements.



0002 - 1177-BQA - MapCHECK® 2 Beam QA Software Module - PROFILER software for use with MapCHECK 2 for comprehensive beam QA analysis.



0003 1083000-0 - MapPHAN -2 (5cm) Water equivalent phantom securely holds MapCHECK® 2 array at measurement plane depth of 5cm and backscatter depth of 5cm. Measurement may occur in the coronal and sagittal positions.



0004 - 1122000-0Z - IC PROFILER A linac radiation beam scanning system providing real-time beam profile data for beam alignment during LINAC factory testing, for field installation and service, and for routine trending of LINAC beam characteristics in clinical site. IC PROFILER uses 251 ionization chambers placed in four linear arrays (X,Y and two diagonals) on a 5mm grid. Measurement range is specified as 32cm on both X and Y axes and 45cm on the diagonals. Comprehensive PC analysis software included. 25 meter power-data cable, USB/serial power data supply, USB cable, Serial cable, 1 year warranty. Includes case.



0005 1118000-0Z - EDGE Dosimetry Detector Fully guarded therapy beam scanning diode for precision IMRT and SRS commissioning and modeling. Active area of 0.8 x 0.8mm with 0.5mm effective buildup. Waterproof, cable length 1.5m, connecting system triax-BNC. Includes one holder (p/n: 1118320 for PTW, p/n: 1118325 for Wellhofer or p/n: 1118375 for Scanditronix) Specify Sun Nuclear, PTW, IBA Blue Phantom or RFA 200 tank when ordering



0006 1122000-EAZ - Gantry Mounting Fixture, Agility Supported Holds IC PROFILER at 100cm SPD. Fits Elekta. Agility Supported. For use on non-Agility Head, touchguard must be removed before mounting



0007 1122-AZ - Adapter plate for the GMF (1122000-V and 1122000-E) - Adapter plate for the GMF (1122000-V and 1122000-E) to support MapCHECK® 2 (1177000-0), PROFILER 2 (1174000-0) and Daily QA 3 (1093000-0). Supports device inherent buildup only. Requires 1122000-V or 1122000-E



0008 1122608Z - Energy Verification Kit Includes Electron Energy Quad Wedge Plate and Photon Energy Quad Wedge Plate. Quad aluminum wedge plates designed for precise energy measurements independent of wedge positioning and suitable for 4MeV to 22MeV (electrons) and 6MV to 18MV (photons). 3mm of acrylic material surrounds each wedge. For use with the IC PROFILER.













SALIENT CHARACTERISTICS

SUN NUCLEAR Mapcheck2 System

(1) IMRT/IGRT/SRS/SBRT patient QA Device

(2) Requirements

High resolution

Large field size

High detector density

Can be used for QA of gated plans

Absolute dose measurements

Easy to setup

FFF support

Real-time measurements

User calibration

Stabilize array at measurement plane depth of 5cm

Stabilize backscatter depth at 5cm

Profiler software for comprehensive beam QA analysis



Interested parties should submit with their response the following information: Company name, capability statement, DUNS Number and address, business size, contact information, and social-economic status. Please email this information to arlene.blade@va.gov no later than 10:00 am CST Wednesday, May 17, 2017. Phone inquiries will not be accepted.