General Requirements: Brand name or equal Power Load System are needed for the Temple, TX in accordance with the following requirements: Q&A Wednesday Jun 2- Friday Jun 4 1 PM CST Quote Due Wednesday 9 Jun 2021 4 PM CST.

ITEM NUMBER

DESCRIPTION OF SUPPLIES/SERVICES

QUANTITY

UNIT

UNIT PRICE

AMOUNT

0001

3.00

EA

$00.00

$00.00

MTS POWER LOAD

LOCAL STOCK NUMBER: 639005550001

0002

3.00

EA

$00.00

$00.00

6506 MTS PWRPRO COT HIGH CNFIG

LOCAL STOCK NUMBER: 650605550003

0003

3.00

EA

$00.00

$00.00

ProCare Power-PRO Prevent Service: Annual onsite prevention maintenance inspection and unlimited repairs including parts, labor and travel with battery coverage for Power-PRO XT

LOCAL STOCK NUMBER: 71061PT

0004

3.00

EA

$00.00

$00.00

ProCare Power-LOAD Prevent Service: Annual onsite preventive maintenance inspection and unlimited repairs including parts, labor and travel with battery coverage for MTS POWER LOAD

LOCAL STOCK NUMBER: 76011PT

GRAND TOTAL

$00.00

Item Name: Power-Load

Salient Characteristics:

IPX6: The system is tested to withstand powerful water jets (IEC 60601-1 and IEC 60601-1-2)

Conforms to industry standards for mechanical and electrical safety for medical electrical devices, as well as electromagnetic compatibility and immunity, BS EN-1789:2007 clause 4.5.9, when used with Power-PRO Cot and X-Restraints

This is a dynamic crash test which subjects a 50th percentile dummy to nominal 10g deceleration for a minimum of 50ms.

Following the test there shall be no sharp edges and SAE J3027 compliant when used with Stryker s Power-PRO Cot and X-Restraints

provide a linear guide for loading and unloading the cot

remote actuation from Power-PRO foot end controls

Engages to the cot during loading and unloading, providing a means of lifting and lowering

Safe working load of 870 lb and capable of lifting patients weighing up to 700 lbs.

Mounts inside the patient compartment to prevent environmental exposure and corrosion

Power washable and inductively charges Stryker s SMRT Battery.

Item Name: Power-Pro XT Cot

Salient Characteristics:

IPX6: The system is tested to withstand powerful water jets (IEC 60601-1 and IEC 60601-1-2)

Conforms to industry standards for mechanical and electrical safety for medical electrical devices, as well as electromagnetic compatibility and immunity, BS EN-1789:2007 clause 4.5.9, when used with Power-PRO Cot and X-Restraints

This is a dynamic crash test which subjects a 50th percentile dummy to nominal 10g deceleration for a minimum of 50ms.

Following the test there shall be no sharp edges and SAE J3027 compliant when used with Stryker s Power-PRO Cot and X-Restraints

provide a linear guide for loading and unloading the cot

remote actuation from Power-PRO foot end controls

Engages to the cot during loading and unloading, providing a means of lifting and lowering

Safe working load of 870 lb and capable of lifting patients weighing up to 700 lbs.

Mounts inside the patient compartment to prevent environmental exposure and corrosion

Power washable and inductively charges Stryker s SMRT Battery.

Manual release handle for unloading that uses hydraulic dampening to prevent abrupt jarring to the patient or operator

battery is placed at the foot end of the stretcher

cot legs power-retract in 3.5 seconds which speeds load time

cot load height of 36 and is operator adjustable to match the deck height of individual ambulances

foot-end of the cot provides lifting bars and operator controls at two different heights, thus providing optimal ergonomics to most operator heights

The foot end of the cot contains a large battery indicator light which displays amber or green which indicates battery level

A warning is given by a flashing amber light, providing the operator the time to change the battery before full depletion of power

has 6 x 2 sealed casters and bearings

foot end mounted hourly usage meter

powder-coating of the aluminum frame (including the patient handling surfaces) and sealed caster bearings, thus reducing aluminum oxidation throughout the cot

power washable

The Department of Veterans Affairs is seeking both manufacturers and/or distributors of the exact match or functionally equivalent equipment/ services to the following listed above Stryker Power Load System.

52.211-6 Brand Name or Equal.

As prescribed in 11.107(a), insert the following provision:

Brand Name or Equal (Aug 1999)

     (a) If an item in this solicitation is identified as brand name or equal, the purchase description reflects the characteristics and level of quality that will satisfy the Government s needs. The salient physical, functional, or performance characteristics that equal products must meet are specified in the solicitation.

     (b) To be considered for award, offers of equal products, including equal products of the brand name manufacturer, must-

          (1) Meet the salient physical, functional, or performance characteristic specified in this RFI.

          (2) Clearly identify the item by-

               (i) Brand name, if any; and

               (ii) Make or model number.

          (3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer; and

          (4) Clearly describe any modifications the offeror plans to make in a product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show the modifications.

     (c) The Contracting Officer will evaluate equal products on the basis of information furnished by the offeror or identified in the offer and reasonably available to the Contracting Officer. The Contracting Officer is not responsible for locating or obtaining any information not identified in the offer.

     (d) Unless the offeror clearly indicates in its offer that the product being offered is an equal product, the offeror shall provide the brand name product referenced in the solicitation.

(End of clause)

VAAR 852.212-72 Gray Market Items:

a) Gray market items are Original Equipment Manufacturers' (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical equipment only for VA Medical Centers. No remanufactures or gray market items will be acceptable.

(b) Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system, verified by an authorization letter or other documents from the OEM, such that the OEM's warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions.

(End of clause)

FAR 52.212-2 Evaluation-Commercial Items: A copy of the authorized distributor letter from the contractor to verify that you are an authorized distributor of the products/services SHALL BE SUBMITTED WITH THE QUOTE AND IS MANDATORY.

Please title email with RFQ Solicitation Number and Name Power Load System

Attachments

Files attached to this notice, newest first
File Type Posted
36C25721Q0958_1.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
6515--Stryker Power Load System This notice · Latest solicitation Solicitation
6515--Stryker Power Load System Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity