About this file

Drawing for CLINs 001-003

View the file

Other files for this federal contract opportunity

Other files attached to Furniture, newest first.
File Type Posted
products_updated_5APR17.xlsx XLSX spreadsheet
Drawing_UPDATED.pdf PDF
products.xlsx XLSX spreadsheet
Drawing_Option.pdf PDF
drawing_option1.pdf PDF
SOW.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R

EF

GENERAL FLOOR PLAN NOTES

1. FINISH FLOOR ELEVATION = XXX'-X". -(X) = DISTANCE OF GRADE BELOW FFE

IN INCHES. + X = DISTANCE OF GRADE ABOVE FFE IN INCHES. FINISH FLOOR

ELEVATION OF BUILDING IS REFERENCED AS ARCHITECTURAL DATUM

ELEVATION 100'-0", AND IS MEASURED FROM THE TOP OF CONCRETE SLAB.

SEE CIVIL DRAWINGS FOR ELEVATIONS BASED ON TOPOGRAPHIC DATUM.

2. DO NOT SCALE DRAWINGS

3. THE CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL MILLWORK,

MECHANICAL FIXTURES, PLUMBING FIXTURES AND ELECTRICAL DEVICES AS

REQUIRED.

4. ALL LUMBER IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE

TREATED INCLUDING ALL SILL PLATES FOR WOOD STUD WALLS.

5. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF

ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH

ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE

ARCHITECT FOR REVIEW.

6. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF

MASONRY OR CENTER OF OPENING, U.N.O.

7. COORDINATE MISCELLANEOUS STEEL REQUIREMENTS FOR MOUNTING /

HANGING OWNER SUPPLIED EQUIPMENT.

8. BUILDER SHALL COORDINATE ALL ROUGH OPENING DIMENSIONS WITH

FLASHING DETAILS.

X

GENERAL PARTITION NOTES

1. SEE SHEET A0.3 FOR PARTITION TYPES. PROVIDE MOISTURE RESISTANT

GWB ON ALL WALLS & CEILINGS IN ALL BATHROOM, RESTROOM & SHOWER

LOCATIONS, & WITHIN 4'-0" OF SINKS, TOILETS AND SHOWERS.

2. ALL DIMENSIONS ARE TO FACE OF STUD OR CENTER OF OPENING UNLESS

NOTED OTHERWISE.

3. INSTALL ALL FIRE RATED WALL & CEILING ASSEMBLIES FOLLOWING DETAILS.

FASTENERS AND SPACING IN ACCORDANCE WITH UL FIRE RESISTANCE

DIRECTORY.

4. EXTEND GWB TO UNDERSIDE OF FLOOR OR DECK ON FIRE BARRIERS. GWB

SHALL TERMINATE AT UNDERSIDE OF DECK AT FIRE PARTITIONS UNLESS

OTHERWISE DETAILED.

5. STAGGER ALL ELECTRICAL DEVICES IN FIRE BARRIERS & FIRE PARTITIONS.

6. INSTALL APPROVED FIRE STOP MATERIAL AT ALL PENETRATIONS THROUGH

FIRE RATED WALLS & FLOORS.

7. ALL WIRE PENETRATIONS THROUGH FIRE RATED WALLS PLATES & FLOORS

SHALL BE SEALED WITH FIRE STOP SEALANT.

8. METALLIC PIPE PENETRATIONS SHALL BE SEALED AROUND PENETRATIONS

WITH FIRE STOP SEALANT AT FIRE RATED WALLS, FLOORS & CEILINGS.

9. NON-METALLIC PIPE PENETRATIONS SHALL BE SEALED WITH FIRE STOP

COLLAR AROUND PENETRATION WITH FIRE STOP SEALANT.

10. CONTRACTOR SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF

ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH

ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE

ARCHITECT FOR REVIEW.

CONSTRUCTION LEGEND

- NEW PARTITIONS

- CONSTRUCTION NOTE. SEE

LEGEND BELOW

CONSTRUCTION NOTE LEGEND

1 NEW 2 HR FIRE RATED COUNTER

SHUTTER

SURFACE MOUNTED FIRE

EXTINGUISHER CABINET W/ 10LBS ABC

EXTINGUISHER

3 NEW WATER ENTRANCE LOCATION, SEE

PLUMB.

- EXISTING TO REMAIN

1 HR. FIRE RATED MASONRY/BRICK

WALL INFILL TO MATCH EXISTING.

TOOTH BRICK & BLOCK

5 SKYLIGHT ABOVE

6 6'-0" x 6'-0" FOOT GRILLE

N.I.C.

ADD ALTERNATE #1

PROJECT AREA

ADD ALTERNATE #2

CORRIDOR

x1 x1 x2 x2 x3 x3 xA xB xC xD xE xF

IT ROOM

2A

OFFICE 3

OFFICE 2

OFFICE 1

KITCHEN

VESTIBULE

41.2

33.2

16 17

1B

1B

1A

2B

2A10

0" 8'

- 8

9'

- 4

8"

1'

- 0

8'

- 2 "1'

- 0

1'

- 9

3"

0" 0'

- 8

1'

- 4

0"

77' - 6"

4' - 2" 23' - 8" 22' - 8" 1' - 0" 16' - 5" 8' - 7" 1' - 0"

7C

4"

C

A4.1

A4.1

A4.1

A4.1

A4.1

A4.1

A4.1

A4.1

RADAR BAY

OFFICE 4

43 OPEN OFFICE

44 SERVICE

CORRIDOR

BOILER ROOM

BREAK

CUSTODIAN

CLASSROOM 1

CLASSROOM 2

WOMEN'S

LOCKER ROOM

KITCHENETTE

CONF.

CUST.

CORRIDOR

42.242.3

44.2

37.3

2"

A1.4

A1.4

15.2

A6.1 3

37.2

37.1

41.1

5'

- 8

A6.11

A6.1 2

6' - 8" 16' - 0" 10' - 0"

44.1

6'

- 4

0'

- 8

6' - 0"

M.O.

12' - 0" 2' - 0"

M.O.

3' - 4" 6' - 0"

M.O.

4' - 0" 6' - 0"

M.O.

3' - 4" 3' - 4"

M.O.

4' - 0" 4' - 8"

M.O.

4' - 0" 6' - 0"

M.O.

3' - 4"

9'

- 2

5'

- 0

M.

O.

4'

- 0

5'

- 4

M.

O.

4'

- 0

5'

- 8

M.

O.

4'

- 0

4"

M.

O.

4'

- 0

3'

- 8

M.

O.

4'

- 0

4'

- 0

4'

- 1

7' - 6"

8 5 /8"

9'

- 0

8'

- 4 3/

4"

M.O.

5' - 4" 4' - 0"

D

1.5

B

A

FITNESS ROOM

B.9

3.7

3.7

A.1

2.7

4' - 2" 10' - 0" 13' - 8" 16' - 0" 6' - 8" 1' - 0" 16' - 5" 8' - 7" 1' - 0"

7C

2A

1B

2A

7B

2A

2A 2A

1A

1A

7C7C

A6.1

M.

O.

6' -4

A

A

A

A

A

A A

33.1

15.1

4 4

7C

2A

8"

23' - 8"

8' - 8" 3' - 4" 4' - 4" 3' - 4" 4' - 0"

V1

V2

A2.2 5

42.1

CORRIDOR

DRILL HALL

3' - 0"

11' - 8 3/8" 8' - 4"

A5.2

ADD ALTERNATE #1

ADD ALTERNATE #2

4' - 0"

3' - 0"

CS-1

1/4 xA xB

A4.1

A4.1

A4.1

A4.1

RADAR BAY

B

A

A.1

27' - 0"

1' -2

1/4

F.O. BRICK

27' - 0"

F.

O.

BR

IC

K

0"

B

C

D

1' -8

311 Great Road Littleton, MA 01460 t: 978.486.4301 e-mail: info@blwengineers.com

ELECTRICAL * PLUMBING * FIRE PROTECTION

TTG PROJECT No:

REVISIONS

DRAWN BY: SCALE: DATE:

STAMP

803 McGEE DRIVE

PORTSMOUTH, NEW HAMPSHIRE

NEW HAMPSHIRE ARMY NATIONAL GUARD

PORTSMOUTH READINESS CENTER

27 Locke Rd.

Concord, New Hampshire 03301 t:603.228.1122 hlturner.com

ARCHITECTS ENGINEERS

The H.L. Turner Group Inc.

BUILDING SCIENTISTS

COPYRIGHT: THE H.L. TURNER GROUP INC.

C 2015

"Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only -except as excluded by individual specifications (e.g.

Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others." As indicated

FLOOR PLAN

A1.206/19/2015EJD

4181-2

CONSTRUCTION DOCUMENTS

NScale:A1.2 1/8" = 1'-0"

1 LEVEL 1 PLAN

Scale:A1.2 1/8" = 1'-0"

3 UPPER LEVEL 1 - RADAR BAY

N

NO. DESRIPTION DATE