R
EF
GENERAL FLOOR PLAN NOTES
1. FINISH FLOOR ELEVATION = XXX'-X". -(X) = DISTANCE OF GRADE BELOW FFE
IN INCHES. + X = DISTANCE OF GRADE ABOVE FFE IN INCHES. FINISH FLOOR
ELEVATION OF BUILDING IS REFERENCED AS ARCHITECTURAL DATUM
ELEVATION 100'-0", AND IS MEASURED FROM THE TOP OF CONCRETE SLAB.
SEE CIVIL DRAWINGS FOR ELEVATIONS BASED ON TOPOGRAPHIC DATUM.
2. DO NOT SCALE DRAWINGS
3. THE CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL MILLWORK,
MECHANICAL FIXTURES, PLUMBING FIXTURES AND ELECTRICAL DEVICES AS
REQUIRED.
4. ALL LUMBER IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE
TREATED INCLUDING ALL SILL PLATES FOR WOOD STUD WALLS.
5. CM SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF
ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH
ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE
ARCHITECT FOR REVIEW.
6. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF
MASONRY OR CENTER OF OPENING, U.N.O.
7. COORDINATE MISCELLANEOUS STEEL REQUIREMENTS FOR MOUNTING /
HANGING OWNER SUPPLIED EQUIPMENT.
8. BUILDER SHALL COORDINATE ALL ROUGH OPENING DIMENSIONS WITH
FLASHING DETAILS.
X
GENERAL PARTITION NOTES
1. SEE SHEET A0.3 FOR PARTITION TYPES. PROVIDE MOISTURE RESISTANT
GWB ON ALL WALLS & CEILINGS IN ALL BATHROOM, RESTROOM & SHOWER
LOCATIONS, & WITHIN 4'-0" OF SINKS, TOILETS AND SHOWERS.
2. ALL DIMENSIONS ARE TO FACE OF STUD OR CENTER OF OPENING UNLESS
NOTED OTHERWISE.
3. INSTALL ALL FIRE RATED WALL & CEILING ASSEMBLIES FOLLOWING DETAILS.
FASTENERS AND SPACING IN ACCORDANCE WITH UL FIRE RESISTANCE
DIRECTORY.
4. EXTEND GWB TO UNDERSIDE OF FLOOR OR DECK ON FIRE BARRIERS. GWB
SHALL TERMINATE AT UNDERSIDE OF DECK AT FIRE PARTITIONS UNLESS
OTHERWISE DETAILED.
5. STAGGER ALL ELECTRICAL DEVICES IN FIRE BARRIERS & FIRE PARTITIONS.
6. INSTALL APPROVED FIRE STOP MATERIAL AT ALL PENETRATIONS THROUGH
FIRE RATED WALLS & FLOORS.
7. ALL WIRE PENETRATIONS THROUGH FIRE RATED WALLS PLATES & FLOORS
SHALL BE SEALED WITH FIRE STOP SEALANT.
8. METALLIC PIPE PENETRATIONS SHALL BE SEALED AROUND PENETRATIONS
WITH FIRE STOP SEALANT AT FIRE RATED WALLS, FLOORS & CEILINGS.
9. NON-METALLIC PIPE PENETRATIONS SHALL BE SEALED WITH FIRE STOP
COLLAR AROUND PENETRATION WITH FIRE STOP SEALANT.
10. CONTRACTOR SHALL REVIEW PRIOR TO INSTALLATION ANY CONFLICT OF
ENGINEERING TRADE DEVICES (I.E. FIRE ALARM STROBES) WITH
ARCHITECTURAL DETAILS AND BRING THOSE DISCREPANCIES TO THE
ARCHITECT FOR REVIEW.
CONSTRUCTION LEGEND
- NEW PARTITIONS
- CONSTRUCTION NOTE. SEE
LEGEND BELOW
CONSTRUCTION NOTE LEGEND
1 NEW 2 HR FIRE RATED COUNTER
SHUTTER
SURFACE MOUNTED FIRE
EXTINGUISHER CABINET W/ 10LBS ABC
EXTINGUISHER
3 NEW WATER ENTRANCE LOCATION, SEE
PLUMB.
- EXISTING TO REMAIN
1 HR. FIRE RATED MASONRY/BRICK
WALL INFILL TO MATCH EXISTING.
TOOTH BRICK & BLOCK
5 SKYLIGHT ABOVE
6 6'-0" x 6'-0" FOOT GRILLE
N.I.C.
ADD ALTERNATE #1
PROJECT AREA
ADD ALTERNATE #2
CORRIDOR
x1 x1 x2 x2 x3 x3 xA xB xC xD xE xF
IT ROOM
2A
OFFICE 3
OFFICE 2
OFFICE 1
KITCHEN
VESTIBULE
41.2
33.2
16 17
1B
1B
1A
2B
2A10
0" 8'
- 8
9'
- 4
8"
1'
- 0
8'
- 2 "1'
- 0
1'
- 9
3"
0" 0'
- 8
1'
- 4
0"
77' - 6"
4' - 2" 23' - 8" 22' - 8" 1' - 0" 16' - 5" 8' - 7" 1' - 0"
7C
4"
C
A4.1
A4.1
A4.1
A4.1
A4.1
A4.1
A4.1
A4.1
RADAR BAY
OFFICE 4
43 OPEN OFFICE
44 SERVICE
CORRIDOR
BOILER ROOM
BREAK
CUSTODIAN
CLASSROOM 1
CLASSROOM 2
WOMEN'S
LOCKER ROOM
KITCHENETTE
CONF.
CUST.
CORRIDOR
42.242.3
44.2
37.3
2"
A1.4
A1.4
15.2
A6.1 3
37.2
37.1
41.1
5'
- 8
A6.11
A6.1 2
6' - 8" 16' - 0" 10' - 0"
44.1
6'
- 4
0'
- 8
6' - 0"
M.O.
12' - 0" 2' - 0"
M.O.
3' - 4" 6' - 0"
M.O.
4' - 0" 6' - 0"
M.O.
3' - 4" 3' - 4"
M.O.
4' - 0" 4' - 8"
M.O.
4' - 0" 6' - 0"
M.O.
3' - 4"
9'
- 2
5'
- 0
M.
O.
4'
- 0
5'
- 4
M.
O.
4'
- 0
5'
- 8
M.
O.
4'
- 0
4"
M.
O.
4'
- 0
3'
- 8
M.
O.
4'
- 0
4'
- 0
4'
- 1
7' - 6"
8 5 /8"
9'
- 0
8'
- 4 3/
4"
M.O.
5' - 4" 4' - 0"
D
1.5
B
A
FITNESS ROOM
B.9
3.7
3.7
A.1
2.7
4' - 2" 10' - 0" 13' - 8" 16' - 0" 6' - 8" 1' - 0" 16' - 5" 8' - 7" 1' - 0"
7C
2A
1B
2A
7B
2A
2A 2A
1A
1A
7C7C
A6.1
M.
O.
6' -4
A
A
A
A
A
A A
33.1
15.1
4 4
7C
2A
8"
23' - 8"
8' - 8" 3' - 4" 4' - 4" 3' - 4" 4' - 0"
V1
V2
A2.2 5
42.1
CORRIDOR
DRILL HALL
3' - 0"
11' - 8 3/8" 8' - 4"
A5.2
ADD ALTERNATE #1
ADD ALTERNATE #2
4' - 0"
3' - 0"
CS-1
1/4 xA xB
A4.1
A4.1
A4.1
A4.1
RADAR BAY
B
A
A.1
27' - 0"
1' -2
1/4
F.O. BRICK
27' - 0"
F.
O.
BR
IC
K
0"
B
C
D
1' -8
311 Great Road Littleton, MA 01460 t: 978.486.4301 e-mail: info@blwengineers.com
ELECTRICAL * PLUMBING * FIRE PROTECTION
TTG PROJECT No:
REVISIONS
DRAWN BY: SCALE: DATE:
STAMP
803 McGEE DRIVE
PORTSMOUTH, NEW HAMPSHIRE
NEW HAMPSHIRE ARMY NATIONAL GUARD
PORTSMOUTH READINESS CENTER
27 Locke Rd.
Concord, New Hampshire 03301 t:603.228.1122 hlturner.com
ARCHITECTS ENGINEERS
The H.L. Turner Group Inc.
BUILDING SCIENTISTS
COPYRIGHT: THE H.L. TURNER GROUP INC.
C 2015
"Electronic images of these documents may be used for the purpose of expediting shop drawings and coordination drawings for this project only -except as excluded by individual specifications (e.g.
Structural steel). It shall be unlawful to use them for any other purpose. The Architect's or Engineer's seals shall not appear on any documents that are modified by others. The Architect shall bear no responsibility for any modifications to the original documents by others." As indicated
FLOOR PLAN
A1.206/19/2015EJD
4181-2
CONSTRUCTION DOCUMENTS
NScale:A1.2 1/8" = 1'-0"
1 LEVEL 1 PLAN
Scale:A1.2 1/8" = 1'-0"
3 UPPER LEVEL 1 - RADAR BAY
N
NO. DESRIPTION DATE