Amendment_0001.pdf
PDF 171 KB Posted
- Attached to
- Water Quality Sondes Federal contract opportunity
- Solicitation number
- W912PP18Q0150
About this file
Amendment 0001
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQW912PP18Q0150.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
This amendement is being issued to modify the scope of requirements. See attached changes.
1. CONTRACT ID CODE PAGE OF PAGES
1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 17-Sep-2018
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912PP18Q0150
X 9B. DATED (SEE ITEM 11)
11-Sep-2018
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
17-Sep-2018
CODE
US ARMY ENGINEER DISTRICT, ALBUQUERQUE
4101 JEFFERSON PLAZA NE
ALBUQUERQUE NM 87109-3435
W912PP 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
erica.m.talley@usace.army.milEMAIL:505-342-3223TEL:
ERICA M TALLEY / CONTRACTING OFFICER
W912PP18Q0150
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
SCOPE OF REQUIREMENT
STATEMENT OF REQUIREMENT
WATER QUALITY SONDES
US ARMY CORPS OF ENGINEERS
ALBUQUERQUE DISTRICT
1. SPECIFICATIONS
A. Water quality sonde: The Contractor shall provide thirteen (13) multi-parameter sondes compatible with YSI EXO sondes, sensors, field cable, and handheld computer. Each sonde shall accommodate a payload of four (4) sensor ports and one (1) central wiper port. Features and specification are as follows:
i. The sonde shall be capable of operating in water depths up to 820 feet (250m) and temperatures ranging from 23° to 122°F ( -5- 50°C).
ii. The sonde shall not exceed 3.00 inches (7.62 cm) in diameter, 23.1 in. (58.67 cm) in length, and 4.41 lbs. (2.0 kg) in weight, with a full payload of 4 probes, 1 wiper, and a probe guard installed.
iii. The sonde shall be a platform with universal ports that can accommodate a variety of sensors, which can be used or reconfigured at any time by the end user in the field. Similarly, the sensors shall have hermaphroditic wet-mateable connectors, allowing them to be plugged interchangeably into any sensor port.
iv. The sonde shall be designed to withstand the harsh conditions of field use by using rugged materials, including Titanium, laser-welded probe housings to resist leaks; wet-mateable connectors that resist corrosion; impact-resistant and chemical-resistant Xenoy polymer reinforced housing; and sapphire glass on optical sensor windows.
v. The sonde shall be equipped with built-in Bluetooth wireless technology for cable-free communications when calibrating, communicating and downloading data (512 MB total memory). An internal magnetic switch and external activation key for wireless control of the Bluetooth radio shall be included. The sonde shall be capable of connecting to field-replaceable sensors that measure dissolved oxygen (DO), conductivity, temperature, pH, ORP, turbidity, chlorophyll/blue-green total algae, fluorescent dissolved organic matter (fDOM) and central wiper. The sensors shall be capable of being removed without opening the sonde or exposing the internal electronics to the environment.
vi. The sonde shall provide low-power consumption for extended deployments and must be able to measure Temperature, conductivity, depth, pH or Turbidity and Optical DO for duration of 90 days at a 15-minute sampling interval.
vii. The sonde shall have an internal depth sensor, non-vented, 0-10 meter depth.
viii. The sonde shall include a central wiper port that is capable of wiping all sensors listed in
Section 1B.
B. Sonde Sensors and central wiper: Continuous water quality sensors compatible with YSI EXO sondes currently being used by the Albuquerque District. The sensors shall measure the parameters below. All sensors must be “smart” and store all calibration data internally to the sensor. Sensors shall be able to be swapped from one sonde to another or from one sonde port to another without recalibration. The Contractor shall provide sensors (see quantities below) for each of the following parameters that meet or exceed the features and specification below:
i. Optical DO sensor: The Contractor shall provide thirteen (13) sensors that employs the Luminescent “Life Time” DO measurement technique. The sensor membrane must be field replaceable component that does not require the use of tools. The sensor shall be able to be calibrated with a one-point (saturated air or water) or a two-point (zero DO and saturated air or water) oxygen calibration.
ii. Turbidity sensor: The Contractor shall provide thirteen (13) sensors capable of measuring turbidity with a Nephlometric type sensor capable of measuring turbidity from 0-4000 NTU.
The sensor will have an accuracy of +/- 2% of reading or 0.3 NTUs (whichever is greater) in AMCO-AEPA Polymer standards from 0-999 NTU and an accuracy of +/- 5% of reading from 1000-4000 NTU.
iii. Wiped Conductivity and temperature sensor: The Contractor shall provide fifteen (15) sensors capable of measuring temperature using a NIST-traceable calibrated thermistor in the range of -5 to 50 degrees C with an accuracy of +/- 0.2 degrees C and a resolution of 0.001 degrees C from -5 to 50 degrees C. Each temperature sensor must include a factory calibration/NIST reference sheet. The instrument shall be capable of measuring conductivity using a four-electrode cell in the range of 0-100 mS/cm with an accuracy of +/- 1% or 0.002 mS/cm and a resolution of 0.0001 to 0.01 mS/cm. The instrument shall be capable of measuring salinity in the range of 0 to 70 ppt with an accuracy of +/- 2% or 0.2ppt with a resolution of 0.01 ppt.
Additionally, the cell design should prevent bubbles from settling on electrodes and interfering with measurements. The conductivity sensor must be a linear device requiring only a single-point calibration. It shall be compatible with a central wiper system and spacer kit to prevent biofouling.
iv. Ungarded pH sensor: The Contractor shall provide thirteen (13) sensors that are able to measure to spec across all ionic strength waters. The pH sensor will be equipped with an internal amplifier to improve signal response and stability and utilize a replaceable sensor head that can be field replaced at minimal cost.
v. Central wiper: The Contractor shall provide thirteen (13) central wipers that keep the payload sensor faces clean during long-term deployments.
C. Sonde Accessories:
i. Six (6) 15-meter EXO compatible flying lead cables.
ii. Six (6) 20-meter EXO compatible flying lead cables.
iii. One (1) 2-meter EXO compatible field cables.
iv. One (1) handheld display that interfaces with EXO sondes. Rechargeable lithium-ion battery that provides a minimum of 40 hours if powering the handheld only, and 20 hours if powering the handheld, sonde and 4 sensors.
v. Fifteen (15) unguarded pH probe replacement modules.
vi. Six (6) guarded pH probe replacement modules.
vii. Two (2) Turbidity Standard. - 100 NTU (6136), 124 FNU (EXO & ProDSS);
(SKU:607300) - 1 Gallon
viii. Two (2) Turbidity Standard. - 1000 NTU (6136), 1010 NFNU (EXO & ProDSS);
(SKU:607400) - 1Gallon
ix. Twelve (12) pH Buffer – pH 7 Buffer (SKU: 003822) – 1 pint.
x. Twelve (12) pH Buffer – pH 10 Buffer (SKU: 003823) - 1 pint.
xi. Two (2) Conductivity calibrator solution – 1,000 umhos/cm (3161); fresh water (SKU:
065270) - 1 quart.
D. Telemetry and photovoltaic equipment
i. Twelve (12) 10 amp 12 Volt Solar Charge Controllers with low voltage disconnect, series regulation, and series configuration.
ii. Twelve (12) data loggers with integrated modem
Data logger shall: have an operating temperature range of -40 C; 5 single-ended analog inputs; 8 pulse counter; two voltage excitation terminals; USB and RS-232 communication ports; 1 switched 12 volt terminal; input limits -100 mV to +2500 mV; power requirements 10 to 18 Vdc; 30 MB serial flash data storage; 1.5 mA idle current drain at 12 Vdc; 5 mA active current drain at 12 Vdc for 1 Hz scan with 1 analog measurement;
Modem shall: be 4G LTE category 1; 700, 850, 1700, 1900, and 21100 4G frequency bands; no data provisioning Verizon US Static IP address.
iii. Twelve (12) coaxial antenna cables: shall consist of RG8/U, low-loss coaxial cable fitted with a Type N Male connector on each end. It can support any 50 ohm transmission line application. Each cable shall be 6 feet in length.
iv. Twelve (12) 2 dBd 4G/3G multi-band omnidirectional antennas with mounting hardware.
v. Twelve (12) surge protection kits: shall include bi-directional coaxial RF protector with hardware, suitable for 700 to 2700 MHz; flange mounting bracket; 18 in. Type N to SMA coaxial jumper; 24 in. ground wire assembly
vi. Twelve (12) 20 Watt solar panels: each panel shall have a 15-foot cable; tinned cable terminal wires; standard mounting kit for a mast.
vii. Twelve (12) null modem cables: 9-pin male to 9-pin male connects to RS-232 ports.
2. DELIVERY LOCATION
U.S. ARMY CORPS OF ENGINEERS
Attention: Justin Reale 4101 Jefferson Plaza Albuquerque, NM 87109
3. REQUEST DELIVERY BY: 20-OCT-2018
(End of Summary of Changes)