CU101_amd0001.pdf
PDF 819 KB Posted
- Attached to
- W912PM18B0014 ATF Storage Building Federal contract opportunity
- Solicitation number
- W912PM18B0014
About this file
Revised Sheet CU101
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| ATF_Storage_Sign_in_sheet.pdf | ||
| ATF_Storage_bid_abstract.pdf | ||
| W912PM18B00140001.pdf | ||
| E-202_amd001.pdf | ||
| E-102_amd001.pdf | ||
| SC10-17_Pre-Bid_Attendance_Sheet.pdf | ||
| SC_000010_17_RTA_SPECS.pdf | ||
| SC_000010_17_RTA_PLANS.pdf | ||
| DGN_Files.zip | ZIP file |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELECTRIC SERVICES TO BE
CONSTRUCTED BY SUS,
TRANSFORMER LOCATION
SHOWN IS APPROXIMATE.
T
EL= 509.04'
EL= 504.45'
RIPRAP
CONTROL POINT
PK NAIL
N= 497829.53'
E=1889291.09'
CONTROL POINT
12" SPIKE
N= 498193.96'
E=1888765.76'
C H
A I N
L I N
K
F
E N
C E
G
R A
V E
L
R
O
A D
G
R
A
V
E
L
R
O
A
D
H
B
L
U
E
P
A
I N
T
D
I N
E
SPIGOT
C
H A
I N
L I N
K
F
E N
C
A
O
N G
G
E
O
F
R
O A
D
S
W
A
N
C
R
E
T
P
R
O
N
S
W
A
L
E
FFE=510.91'
BUILDING O-9158
ELECTRIC JUNCTION BOX
6 BOLLARD MOUNTS
IN CONCRETE PAD
A
S
P
H
A
A
D
C
O
N
C
R
E
P
R
O
N
TRANSFORMER
R
I P
R
A
P
GATE
POST
D I T
C H
BOLLARD (TYP)
5002 CONTROL POINT
PK NAIL
N= 497772.84'
E=1888996.37'
EL= 511.90'
REBAR
N= 497920.00'
E=1888993.21'
EL= 508.62'
CONTROL POINT
12" SPIKE
N= 498036.68'
E=1888900.54'
EL= 500.90'
FUTURE BUILDING
UNDER SEPARATE
CONTRACT
W
W
W
PROPOSED
BUILDING
FFE=505.0'
G
R
A
V
E
L
10" CONC
HEADWALL
15" CMP
INV=502.3'
REBAR
N= 497975.80'
E= 1889267.63'
EL= 509.77'
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
SEE ELECTRICAL DRAWINGS
FOR COMM. DETAILS,
BUILDING CONNECTIONS,
AND GROUNDING PLAN
P
B
ELECTRIC SERVICES TO BE CONSTRUCTED
BY SUS, LOCATION SHOWN IS
APPROXIMATE; SEE ELECTRICAL
DRAWINGS FOR BUILDING CONNECTION
M
I N
M
I N
684.0' ± LF OF 1-1/4"
PE SDR21 WATER LINE
BID OPTION 1
C
O
M
M
E
E
E
E
E
E
TOP=503.92'
COMMUNICATION MH
PATCH AND REPAIR
GRAVEL ROAD IN
KIND AND TYPE
TRENCH FOR
WATER PIPE
BID OPTION 1
C-503CU101
C-503CU101
1 1/4" WATER
SERVICE
BID OPTION 1
SEE PLUMBING PLANS FOR
BUILDING CONNECTION
BID OPTION 1
CONTRACTOR IS RESPONSIBLE FOR
INSTALLATION OF ALL UNDERGROUND
CONDUIT AND PULL WIRES FROM EXISTING
COMMUNICATIONS MANHOLE TO BUILDING.
SEE ELECTRICAL DRAWINGS FOR MORE
INFORMATION.
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C A
T E
G O
Y
D
E
D E
S
P
T I O
N
J O
N E
S
F
R A
N K
L
S
R A
L E
I G
H
N
C
F
A X
L I C
E N
S
F
ISSUED FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
N J
R D
D S
C O
N S
T R
U C
T
S
T O
R A
C
I L
I T
Y
J S
O C
A
T F
F O
B
A
G G
N
O R
H
R
O L
I N
A
D
D E
P A
R T
M E
T
M
Y
F O
B
A
G G
N
O R
R
O L
I N
A
D I R
E C
T O
R A
P
U B
L
W
R
K S
D S
U T
I L I T
Y
P
L A
N
C U d g n
CU101
N
UTILITY PLAN
SCALE: 1"=30'
CU101
30'
30' 90'
1"=30'
LEGEND
LIMITS OF DISTURBANCE/LIMITS OF
CONSTRUCTION
EXISTING WATER LINE
EXISTING TREE LINE
EXISTING TREES
EXISTING GRAVEL
NEW GRAVEL
CONCRETE
WATER LINE
UNDERGROUND COMM. LINE
UNDERGROUND ELECTRICAL
LOD LOD
W W
PINE OAK
W W
COMM
E E E
R E
V I S
C
O R
D A
N C
E
W
I T
H
A
M E
N D
M E
A
U
8/21/2018
AutoCAD SHX Text
PUBLIC
AutoCAD SHX Text
WORKS
AutoCAD SHX Text
BRAGG
| Sheets and Views |
| CU101 |
File details come from the government source that posted it.