W912PF-17-T-0060_Amendment_0003.pdf
PDF 798 KB Posted
- Attached to
- Vacuum Sewage Truck Federal contract opportunity
- Solicitation number
- W912PF-17-T-0060
About this file
Amendment 0003
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912PF-17-T-0060_Amendment_0003_Conformed.pdf | ||
| W912PF-17-T-0060_Amendment_0002.pdf | ||
| W912PF-17-T-0060_Amendment_0002_Conformed.pdf | ||
| W912PF-17-T-0060_Amendment_0001_Conformed.pdf | ||
| W912PF-17-T-0060_Amendment_0001.pdf | ||
| W912PF17T0060.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
0011051581
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to:
1. Extend the submission due date to no later than 5:00 p.m. (local time, Rome, Italy) on 26 September 2017.
2. Remove the requirement to include required registration documentation from CLIN 0001. The Vacuum Sew age Truck does not need to be registered w ith the Italian motorization.
3. Require offerors to indicate in their quote the date the truck w ill be delivered by; the required delivery date w ill be adjusted in the subsequent contract aw ard in accordance w ith FBO combined synopsis/solicitation update on 20 September 2017.
4. Update the Technical Data to include a requirement to provide a "Certificate of Origin." No other changes have been made to the Technical Data.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 18
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 22-Sep-2017
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912PF-17-T-0060
X 9B. DATED (SEE ITEM 11)
24-Aug-2017
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
22-Sep-2017
CODE
414TH CSB RCO ITALY SUBOFFICE LIVORNO
VIA AURELIA, EDIFICIO 5131
ZONA DEPOSITO
56128 TIRRENIA (PISA)
W912PF 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912PF-17-T-0060
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SUPPLIES OR SERVICES AND PRICES
CLIN 0001
The CLIN extended description has changed from:
The contractor shall furnish a Vacuum Sewage Truck in accordance with the technical specifications. All transportation costs and required registration documentation in order to transport the truck to the delivery location shall be included in the price.
To:
The contractor shall furnish a Vacuum Sewage Truck in accordance with the technical specifications. All transportation costs to the delivery location shall be included in the price..
The following have been modified:
TECHNICAL SPECIFICATIONS
Vacuum Sewage Truck The Structural design shall be as follows:
Features of the chassis suitable for the below described equipment
Condition New Warranty Manufacturer warranty Cab type Short Wheelbase Minimum 3.690 mm GVW Minimum 1.800 Kg.
Type of gearbox 9-speed mechanical Type of engine power take-off MULTIPOWER or similar Bodybuilder interface Cruise control
In addition the truck shall be equipped with:
Air conditioning Cruise control Differential lock 90° alternator
Tank construction
Vacuum-resistant cylindrical tank made of stainless steel AISI 304.
Tank thickness: minimum 6 mm, 1,700 Ø, material 1.4301 Pressure resistant rounded front and back tank portions; front part: minimum 6 mm, rear part: minimum 8 mm U-shaped external reinforcement rings and internal breakwaters, in compliance with the existing Italian safety regulations as per D.M. 174/95 del 20.10.1995.
Calculation pressure +0,5/-1 bar, max working pressure +0.5 bar, max vacuum pressure -1 bar Overflow valve with pressure safety valve.
Rear door opening via minimum 2 double-acting hydraulic cylinders with safety devices to prevent accidental closure.
Rear door closure via adjustable hydraulic wedges.
Pneumatic valve to prevent waste leakage when the vehicle is in motion.
Tipping system with multi-stage hydraulic cylinder.
Safety catch to block tank overturning.
Tank capacity Sludge tank minimum 7,280 litres Total capacity minimum 7,280 litres
Fresh water polyethylene side reservoirs
The side reservoirs shall be polyethylene type, resistant and have an elegance line have a special curved shape.
The reservoirs capacity shall be defined by combining single modules.
The reservoir capacity shall be increased by combining multiple single units. The final finish panelling shall be in painted fibreglass maximizing the aesthetics of the side of the vehicle.
The shape of the top profile on the reservoir shall serves to ensure the equipment is less exposed to knocks and scrapes.
Technical data:
Minimum total capacity 1,350 + 1,350 = minimum 2,700 litres (3 + 3 units).
Loading by UNI 45 hydrant joint.
Reservoir shall have a vent system.
Digital level gauge on the control panel with low-level warning light shall be present.
Connections between the reservoirs and the pump shall be present.
Rear door
Rear door, shall have minimum of 8 mm thick, in circle-polished stainless steel AISI 304 Rear door opening shall be via minimum 2 double-acting hydraulic cylinders fitted with a safety valve which prevents the accidentally rear door closure in case of a fault in the hydraulic system.
Rear door closure shall be via adjustable hydraulic wedges.
Porthole liquid level gauge
Liquid level gauge with portholes, shall be installed on the rear door of the tank
– Stainless steel tank 4” pneumatic inlet valve
The Pneumatic inlet gate valve shall be 4" (Ø 100) in cast iron/stainless steel, with internal gooseneck and with breakwater.
Cast iron body, stainless steel gate Shall be dedicated for tanks in stainless steel Complete with spherical quick coupling and stopper.
Pneumatic outlet valve
The pneumatic outlet gate valve shall be 6" (Ø 150) in cast iron/stainless steel, complete with spherical quick coupling and stopper.
Shall be dedicated for tanksin stainless steel In addition shall have a manual valve for waste sampling.
Tank tipping system
Tank tipping system with multi-stage hydraulic cylinder, with electro-hydraulic control valve, safety valve and tip warning light in the driver cab This tank tipping system shall facilitates the tank discharge and permits an easier maintenance.
Shall be equipped with rear chute that shall be in stainless steel, bolted to the tank, to facilitate the unloading and keep the area at the back of the vehicle cleaned.
Subframe
The subframe acts shall have a support for the upper structure, without having to make any changes to the chassis
The subframe shall be composed of two high-quality steel profiles, held by crossbars and devices to guarantee maximum stability, in compliance with the guidelines from the chassis manufacturer
It shall be fixed to the vehicle chassis using appropriate devices (screws, shelves, easy-to-dismantle supports), so as to guarantee maximum stability of the entire vehicle in all equipment loading conditions
The equipment subframe shall be anchored to the vehicle chassis using threaded joints with suitable resistant nuts.
The pipes shall be laid tidily inside the frame profiles, to make them easier to maintain.
Power kit covers