24Q0044 Amendment 1.pdf
PDF 570 KB Posted
- Attached to
- Wire Rope Federal contract opportunity
- Solicitation number
- W912ES24Q0044
About this file
This document is an amendment to a solicitation for the purchase of wire rope and line. The U.S. Army Corps of Engineers is seeking to award a contract to supply wire rope and line for its Dredge Goetz fleet, including over 60 items totaling over 15,000 feet of line and wire rope. Specifications include size, minimum breaking strength, finish, grade, and core requirements. The contractor must provide country of origin and breaking strength documentation. Delivery is required by April 1, 2024 to the Dredge Goetz in St. Louis, Missouri. The amendment adds a question and answer section and provides additional scope of work details such as equipment application and termination requirements for certain items.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 24Q0044 Solicitation.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W81G6740188077
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to add a Question and Answ er section and to add additional information to the scope of w ork.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 05-Feb-2024
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912ES24Q0044
X 9B. DATED (SEE ITEM 11)
31-Jan-2024
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
05-Feb-2024
CODE
CONTRACTING DIVISION
USACE, ST PAUL
332 MINNESOTA STREET
SUITE E1500
ST PAUL MN 55101-1323
W912ES 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912ES24Q0044
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
QUESTION AND ANSWER SECTION
Q1. What construction class is the John Deere 555 Winch & the Caterpillar D-76 Winch?
A1. John Deere 555: 6x19 class - 20.6t break force CAT D-7: 6x37 class - 51.7 break force
SECTION SF 1449 - CONTINUATION SHEET
The following have been modified:
SCOPE OF WORK
Project Description:
Physical Support Branch, Dredge Goetz, request the award of a contract for the purchase of wire rope and line for the Dredge Goetz’s fleet. This contract is to supply wire rope and line for the Dredge Goetz and its supporting equipment.
Scope of Work:
Purchase of the following for line:
Quantity Per Coil
Coil Line Length (Feet)
Size Minimum Break Force
(Pounds)
Application Specification
8 600’ ea. 1.1250 22,500 lbs. Deck Rope 1 – 1/8” - 3 Stranded Poly Dacron rope. The individual spool lengths will be 600 foot. The minimum required breaking strength is 22,500 lbs.
Purchase of the following for Wire Rope:
Quantity Per Coil
Coil Line
Length (Feet)
Size (Dia.)
Construction Class
Minimum Break Force (Tons)
Application Specification
4 600’ ea. 5/8” 6 x 19 20.6 Pipeline Winches & Grove LRT 530
The wire rope is used on sheaves, winches, and hoists. Also on our Grove LRT 530. All wire rope shall be tested and certified to meet and/or exceed the below minimum specified breaking force. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
4 600’ 3/4” 6 x 37 29.4 Spud Hoist The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the below minimum specified breaking force. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
2 600’ 1” 6 x 37 29.4 Spud Hoist The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the below minimum specified breaking force. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
1 300’ 7/8” 6 x 37 39.8 Goetz Ladder Cable
The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the below minimum specified breaking force. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
2 1200’ 1-1/4 6 x 37 79.9 Goetz Swing & Spud Winch Cables
The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the below minimum specified breaking force. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
2 100’ 5/8” 6 x 19 20.6 John Deere 555 Winch
Thimble on working end and Swage Eye (2 3/8” Long x 1 1/2” Diameter) for equipment winch drum
6 100’ 1” 6 x 37 51.7 Caterpillar D-7R Winch
Thimble on working end and Swage Eye (2 3/8” Long x 2 ¼” Diameter) for equipment winch drum
4 130’ 1’ 6x19 51.7 Taggatz Spud wire
The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the below minimum specified breaking force. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
OPEN SPELTER SOCKET ONE END
OTHER END PLAIN
To ensure compliance with the Buy American requirements, the Contractor shall list the country of manufacture for each of the products to be delivered under this contract.
Documentation verifying the product being delivered meets or exceeds the listed breaking strength shall be provided at or prior to delivery for ALL items specified.
Order must be delivered by 1 April 2024.
Delivery Location Information:
United States Army Corps of Engineers Attn: Dredge Goetz St Louis Service Base Arsenal St, St. Louis, MO 63118
Hours of Operation:
0700 – 1530: Monday – Friday Closed: Weekends & Holidays