W912DW19R0014_Drawings-.pdf

PDF 11 MB Posted

Attached to
Albeni Falls Dam Main Unit Transformer Replacement, Oldtown, ID Federal contract opportunity
Solicitation number
W912DW19R0014
Issued by
Department of the Army Corps of Engineers Engineering District Seattle

About this file

Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Albeni Falls Dam Main Unit Transformer Replacement, Oldtown, ID, newest first.
File Type Posted
W912DW19R0014_Amendment_0002.pdf PDF
W912DW19R0014_Amendment_0001.pdf PDF
W912DW19R0014_Reference_Drawings_file_2_of_3.pdf PDF
W912DW19R0014_Reference_Drawings_file_3_of_3.pdf PDF
W912DW19R0014_Reference_Drawings_file_1_of_3.pdf PDF
W912DW19R0014_AFD_Main_Unit_Transformer.pdf PDF
PPQ.DOCX DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

A F P -5 .0

-0 -0 /1

D F

IL

E R

K F

L O

R E

N C

E

V

IC

IN

IT

Y M

A P

S

P R

O J E

C T L

O C

A T

IO

N A

N D

C O

V E

R S

H E

E T

G-001

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

IC

T

B C

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E R

E V

E N R

M

IL

E S P .E

D

F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T

PROJECT VICINITY MAP

SOLICITATION NUMBER: ____________________

DATE: ____________

Seattle District of Engineers

US Army Corps

ALBENI FALLS DAM, TRANSFORMER YARD

PEND ORIELLE RIVER, IDAHO

LOCATION

SITE WORK

PROJECT LOCATION MAP

LOCATION

PROJECT

PROJECT PHOTO - TRANSFORMER YARD

15 / 20 MVA, 115 KV GSU TRANSFORMERS SUPPLY

A F P .0

G -0

.d g n

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

A F P -5 .0

-0 -0 /2

D F

IL

E R

K F

L O

R E

N

IN

E X O

F D

R A

W

IN

G S

G-002

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P

F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

INDEX OF DRAWINGS

CONTRACT DRAWINGS

GENERAL

ELECTRICAL

MECHANICAL

STRUCTURAL

REFERENCE DRAWINGS

G-004

G-003

G-002

G-001

E-52-36-4, SH 1

E-52-20-12. SH 12

E-52-20-15, SH 10

E-52-20-15, SH 4

E-52-20-15, SH 3

E-52-20-15, SH 2

E-52-20-15, SH 1

E-52-20-13, SH 13

E-52-20-13, SH 12

E-52-20-13, SH 11

E-52-20-2, SH 10

E-52-18-15, SH 11

E-52-18-1, SH 3

75218

68738

SITE DEVELOPMENT, GENERAL LAYOUT

TRANSFORMER YARD, CABLE TUNNEL - REINFORCEMENT AND MISCELLANEOUS DETAILS

TRANSFORMER YARD, CABLE TUNNEL AND TRANSFORMER DECK, PLAN AND SECTIONS

TRANSFORMER YARD, CONDUIT, GROUNDING & LIGHTING, SECTIONS & DETAILS

TRANSFORMER YARD, CONDUIT, GROUNDING & LIGHTING, PLAN & SECTION

TRANSFORMER YARD, ELECTRICAL EQUIPMENT - TRANSFORMER STRUCTURE, SECTIONS & DETAILS

TRANSFORMER YARD, 115 KV BUS STRUCTURE GENERAL ARRANGEMENT

GENERATOR 3 & TRANSFORMER 3 CONNECTION DIAGRAM

GENERATOR 2 & TRANSFORMER 2 CONNECTION DIAGRAM

GENERATOR 1 & TRANSFORMER 1 CONNECTION DIAGRAM

POWERHOUSE, GENERAL PLAN

TRANSFORMER YARD, CABLE TUNNEL AND TRANSFORMER DECK, CONCRETE REINFORCEMENT

ALBENI FALLS PROJECT SITE MAP

PENNSYLVANIA TRANSFORMER, NAMEPLATE

PENNSYLVANIA TRANSFORMER, OUTLINE OF 13,750 / 18,333 TRANSFORMER

S-101 CONCRETE PAD STEEL PLATES AND MOUNTING DETAILS

TITLETITLE

NUMBER

SHEET

FILE NUMBER DRAWING NUMBER

AFP-5.001-0/4

AFP-5.001-0/3

AFP-5.001-0/2

AFP-5.001-0/1

AFP-5.001-5-0/1

GSU TRANSFORMERS, REQUIREMENTS SUMMARY SHEET

TRANSFORMER YARD CONFIGURATION AND STAGING AREA

INDEX OF DRAWINGS

COVER SHEET, PROJECT LOCATION AND VICINITY MAPS

E-607

E-606

E-605

E-604

E-603

E-602

E-601

E-106

E-105

E-104

E-103

E-102

E-101

AFP-5.001-6-9A24/7

AFP-5.001-6-9A24/6

AFP-5.001-6-9A24/5

AFP-5.001-6-9A24/4

AFP-5.001-6-9A24/3

AFP-5.001-6-9A24/2

AFP-5.001-6-9A24/1

AFP-5.001-6-9A4/4

AFP-5.001-6-9A4/3

AFP-5.001-6-9A4/2

AFP-5.001-6-9A4/1

AFP-5.001-6-9A40/2

AFP-5.001-6-9A40/1

CONTROL AND POWER CABINETS, EXTERNAL CONNECTIONS

ANNUNCIATOR FUNCTIONAL REQUIREMENTS, SHEET 2

ANNUNCIATOR FUNCTIONAL REQUIREMENTS, SHEET 1

TRANSFORMER TEMPERATURE MONITOR, FUNCTIONAL REQUIREMENTS, SHEET 2

TRANSFORMER TEMPERATURE MONITOR, FUNCTIONAL REQUIREMENTS, SHEET 1

CONTROL CABINET, 125 VDC CONTROL SCHEMATIC

480 VAC COOLING SCHEMATIC, 120 VAC CONTROL SCHEMATIC

TRANSFORMER MOUNTED DEVICES, LAYOUT AND DETAILS

480 VAC POWER CABINET LAYOUT

CONTROL CABINET LAYOUT

POWER AND CONTROL CABINETS

GSU TRANSFORMERS, LAYOUT AND LIMITING DIMENSIONS, SHEET 2

GSU TRANSFORMERS, LAYOUT AND LIMITING DIMENSIONS, SHEET 1

A F P .0

G -0

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

A F P -5 .0

-0 -0 /3

D F

IL

E R

K F

L O

R E

N

A N

D S

T A

G

IN

G A

R E

A

T R

A N

S F

O R

M E

R Y

A R

D C

O N

F

IG

U R

A T

IO

N

G-003

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P

F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

PERIMETER SECURITY FENCE

LIGHT POLE (TYPICAL)

ROAD

TO ACCESS

NOTES:

PLAN VIEW

TRANSFORMER YARD CONFIGURATION

PHOTO OF EXISTING TRANSFORMERS IN VAULTS

NOT TO SCALE

INTAKE DECK

TO POWERHOUSE

D

O U

B L E G

A T

E

D

O U

B L E G

A T E

(SEE NOTE 4)

NITROGEN REGULATOR CABINET

(SEE NOTE 5)

FUTURE GAS-IN-OIL MONITOR

DETAILS.

SEE REFERENCE DRAWING E-52-20-15 FOR EMBEDDED CONDUIT7.

ON THE CONCRETE PAD.

SEE SHEET S-101 FOR DETAILS OF THE STEEL MOUNTING PLATES6.

INSTALLATIONS CONTRACTOR.

LOCATION, TO BE PROVIDED AND INSTALLED BY A SEPARATE

GAS-IN-OIL MONITORING SYSTEM (SERVERON TM8) MOUNTING5.

CONTRACTOR.

IN THE LOCATION AS INDICATED BY A SEPARATE INSTALLATIONS

PARAGRAPH 2.12.1, WILL BE REMOTE FROM THE TRANSFORMER

THE REQUIREMENTS OF SPECIFICATIONS SECTION 48 19 23.04 26

THE DUAL-TANK NITROGEN REGULATOR CABINET, AS PROVIDED PER4.

WITHIN THE TRANSFORMER YARD PERIMETER SECURITY FENCE.

CONTRACTOR EQUIPMENT AND PORTABLE TOILET SHALL BE

SHIPMENT CRATES, OIL PROCESSING TRAILER AND GENERATOR,

THE STAGING AREA FOR THE TRANSFORMER ACCESSORIES3.

DIMENSIONS ARE AS SHOWN ON SHEETS E-101 AND E-102.

TRANSFORMER #2 LOCATION, AND THE TRANSFORMER LIMITING

INDICATED ON SHEET S-101, ARE AS SHOWN FOR THE

TRANSFORMER VAULT DIMENSIONS AND LIMITING CLEARANCES,2.

STEEL MOUNTING PLATES AND EMBEDDED CONDUIT LOACTION.

PURPOSES OF CLARITY WHEN SHOWING THE CONCRETE PAD

THE TRANSFORMER HAS NOT BEEN SHOWN IN BANK T1 FOR THE1.

A F P .0

G -0

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

A F P -5 .0

-0 -0 /4

D F

IL

E R

K F

L O

R E

N

Q U

IR

E M

E N

T S S

U M

M A

R Y S

H E

E T

G S

U T

R A

N S

F O

R M

E R

S

G-004

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P

F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

NAMEPLATE DATA:

TANK AND CONSTRUCTION:

ACCESSORIES:

BUSHINGS:

INSULATING OIL:

∙ NAPTHENIC BASE - ASTM D 3487 TYPE II; 0.3% BY MASS OF OXIDATION INHIBITOR

SEPARATE CONTROL AND POWER CABINETS:

SPARE PARTS:

FACTORY ASSEMBLY AND PAINT:

FACTORY ACCEPTANCE TESTS (F.A.T.):

(4) COMPLETELY ASSEMBLED AND WITNESSING OF FACTORY ACCEPTANCE TESTS

(3) COMPLETED CORE/COIL ASSEMBLY, BUT PRIOR TO TANKING

(2) AFTER COMPLETION OF WINDINGS BUT PRIOR TO LANDING ON CORE

(1) DESIGN REVIEW MEETING

∙ INSPECTIONS: GOVERNMENT INSPECTIONS PERFORMED DURING

FOR ONE WEEK PRIOR TO OIL FILLING.

∙ INTERIOR PAINT: PRIMER COAT, OIL-RESISTANT FINISH COAT - WHITE. ALLOW TO CURE

SLIP COATING.

STAINLESS STEEL CABINETS, SHALL REMAIN UNPAINTED. COVER TO RECEIVE A NON-

(MUNSELL 5BG 7/0.4 HIGH-GLOSS). CORROSION RESISTANT SURFACES, AND

∙ EXTERIOR PAINT: PRIMER COAT, EPOXY BASE COAT, POLYURETHANE TOP COAT

MATCH-MARKED FOR EASE OF REASSEMBLY.

∙ ASSEMBLY: TRANSFORMER TO BE FULLY ASSEMBLED, WITH REMOVABLE COMPONENTS

REQUIREMENTS SUMMARY SHEET

ALBENI FALLS DAM 115 KV GSU TRANSFORMERS

(REFERENCE SPECIFICATION SECTION 48 19 23.04 26)

∙ ANALOG TEMPERATURE GAUGE FUNCTIONAL VERIFICATION

∙ BUSHING CURRENT TRANSFORMER ROUTINE TESTS

CAPACITANCE AND POWER FACTOR TESTS DURING TRANSFORMER F.A.T.

∙ EACH HIGH-VOLTAGE AND HIGH-VOLTAGE NEUTRAL BUSHING SHALL UNDERGO

∙ ALL ELECTRICAL AND ELECTO-MECHANICAL DEVICES SHALL BE FUNCTIONALLY TESTED

∙ DE-ENERGIZED TAP CHANGER MECHANICAL OPERATIONAL TEST (5 COMPLETE CYCLES)

CONFIGURATION

- ONE SFRA TEST TO BE PERFORMED WITH THE TRANSFORMER IN THE SHIPPING

AND OIL FILLED

- ONE SFRA TEST TO BE PERFORMED WITH THE TRANSFORMER FULLY ASSEMBLED

- CABLE INTEGRITY TEST REQUIRED

∙ SWEEP FREQUENCY RESPONSE ANALYSIS (WITH ELECTRONIC DATA FILES)

∙ LEAKAGE REACTANCE (WITH ELECTRONIC DATA FILES)

500 PC; ONE HOUR LEVEL: 300 PC

∙ INDUCED VOLTAGE TEST ACCEPTANCE CRITERIA: 7,200 CYCLE ENHANCEMENT LEVEL:

∙ AUDIBLE SOUND LEVEL TESTS SHALL BE PERFORMED ON ONE TRANSFORMER

∙ LIGHTNING IMPULSE TESTS

TRANSFORMER

∙ TEMPERATURE RISE TESTS SHALL BE PERFORMED AT EACH COOLING STAGE ON ONE

∙ ALL 'ROUTINE' TESTS (IEEE C57.12.00, TABLE 17)

VERTICAL DRAFT.COOLING FANS:∙

HOT-DIP GALVANIZED.RADIATORS:∙

CONSTRUCTION.

ORIENTED STEEL. MAXIMUM DESIGN FLUX DENSITY OF 1.75 TESLA. STEP-LAP

LAMINATIONS MAXIMUM THICKNESS OF 0.270MM, COLD-ROLLED, GRAIN-CORE:∙

COMPONENTS.

SEISMIC CALCULATIONS REQUIRED FOR MAIN TANK AND ALL MAJORSEISMIC:∙

DESIGN LOADS FOR EACH EYE SHALL BE TWO TIMES THE ACTUAL LOAD.LIFTING EYES:∙

DESIGNED FOR PAD MOUNTING WITH SEISMIC WELDING TO STEEL PLATES.BASE:∙

ANCHOR POST.

LUG, DBI-SALA MODEL 8517412, DESIGNED FOR USE WITH THE DBI-SALA FALL ARREST

UNI-ANCHOR PLATE ANDPORTABLE FALL ARREST ANCHOR POST MOUNTING PLATE:∙

STAINLESS STEEL BALL-TYPE (WITH THE EXCEPTION OF BUTTERFLY VALVES)VALVES:∙

SHALL NOT BE USED FOR GASKET GROOVES OF RECTANGULAR CROSS-SECTION.

NITRILE NBR (BUNA-N), DURO 50-60, 25% COMPRESSION. O-RING GASKETSGASKETS:∙

24-INCH DIAMETER (MINIMUM ONE)MAN-HOLE:∙

∙ PORTABLE FALL ARREST SYSTEM ANCHOR POST WITH DAVIT ARM (DBI-SALA MODEL 8516691)

∙ ELECTRONIC PRESSURE MONITOR, WITH THREE SENSORS ON MAIN TANK (QUALITROL 930)

WINDING TEMPERATURE MEASUREMENT (QUALITROL QTMS)

∙ TRANSFORMER TEMPERATURE MONITOR WITH COOLING CONTROLS AND FIBER-OPTIC

∙ DIRECTED-FLOW PRESSURE RELIEF DEVICE WITH DISCHARGE PIPING (QUALITROL XPRD)

PACKAGE (MOUNTED REMOTE FROM TRANSFORMER AT REAR OF VAULT)

∙ DUAL TANK NITROGEN REGULATOR CABINET WITH ELECTRICAL

∙ WTI AND OTI GAUGES

∙ OIL LEVEL INDICATOR

4,900 GALLONSMAXIMUM OIL VOLUME:∙

60 KWMAXIMUM LOAD LOSSES (ONAN):∙

25 KWMAXIMUM NO-LOAD LOSSES:∙

68 DBMAXIMUM SOUND LEVEL (ONAF):∙

NITROGEN GAS BLANKETEDOIL PRESERVATION SYSTEM:∙

65 ºCTEMPERATURE RISE:∙

5 TAPS; 2 @ +2.5%, 2 @ -2.5% OF NOMINAL 115 KV TAPSECONDARY WINDING (H) DETC:∙

8.5 % (H-X)IMPEDANCE:∙

60 HZFREQUENCY:∙

THREE-PHASEPHASING:∙

550 (H) / 110 (X) / 150 (H0)BIL LEVELS, KV:∙

115,000 GRDY (H) - 13,200 DELTA (X)VOLTAGE RATINGS:∙

15,000 / 20,000KVA RATING:∙

ONAN/ONAFCOOLING CLASS:∙

CLASS II GSU POWER TRANSFORMERTYPE:∙

ENGRAVED BLACK LETTERING.

CONTROL AND POWER CABINETS SHALL BE ANODIZED ALUMINUM OR STAINLESS STEEL WITH

BUSHINGS MADE OF STAINLESS STEEL WITH BLACK LETTERING. DEVICE NAMEPLATES WITHIN THE

NAMEPLATES SHALL BE PROVIDED FOR THE HIGH-VOLTAGE BUSHINGS AND LOW-VOLTAGE

NAMEPLATE FOR SLING LOCATIONS AND LIFT POSITIONS SHALL ALSO BE PROVIDED. EQUIPMENT

VACUUM THE TANK WILL WITHSTAND, AND CALCULATED X/R RATIO. AN ADDITIONAL DIAGRAM

MANUFACTURING DATE, PLANT LOCATION, GOVERNMENT CONTRACT NUMBER, PRESSURE AND

∙ NAMEPLATES: CAST BRONZE OR STAINLESS STEEL; IEEE C57.12.00, TABLE 7, INCLUDING

- FOLD-DOWN MAINTENANCE TRAY ON INSIDE OF CONTROL CABINET DOOR.

HUMIDISTAT-THERMOSTAT CONTROL.

- PTC RESISTOR DESIGN ENCLOSURE HEATERS WITH INTEGRAL FANS, AND INDUSTRIAL GRADE

- 120 V AC, 20 A HOSPITAL GRADE GFCI RECEPTACLE MOUNTED INSIDE THE CONTROL CABINET.

- 120 V AC, 1,000 LUMEN LED TYPE A19 LAMPS WITH DOOR-ACTUATED SWITCH.

POWER CABINET.

- ALL CIRCUITS, WIRING AND EQUIPMENT RATED GREATER THAN 120 V AC TO BE MOUNTED IN

CABINET DOOR FOR VIEWING.

ON SWING PANEL WITHIN CONTROL CABINET, WITH WEATHERPROOF WINDOW PROVIDED IN

- TRANSFORMER TEMPERATURE MONITOR (QUALITROL QTMS), WITH HMI MODULE MOUNTED

CABINET, WITH WEATHERPROOF WINDOW PROVIDED IN CABINET DOOR FOR VIEWING.

- TWO 10 PT. ANNUNCIATORS (SEL MODEL 2533) MOUNTED ON SWING PANEL WITHIN CONTROL

- LOCKOUT RELAY WITH TRIP COIL MONITORING AND INDICATORS (ELECTROSWITCH SERIES 24)

SPECIAL FEATURES:∙

- 125 AND 250 V DC CIRCUITS - RATED 125/250 OR 250 V DC, AND 10,000 A INTERRUPTING

- 120 V AC CIRCUITS - RATED 250 V DC AND 120/240 OR 240 V AC, AND 10,000 A INTERRUPTING

- 480 V AC CIRCUITS - RATED 600 V AC AND 35,000 A INTERRUPTING AT 480 VAC

MOLDED-CASE CIRCUIT BREAKERS:∙

120 V AC CIRCUITS - 10 A

- SINGLE-BREAK INDUCTIVE LOAD INTERRUPTING RATING: 125 V DC CIRCUITS - 1.5 A;

- RATED FOR 600 V AC OR 250 V DC

∙ SWITCHES:

120 V AC CIRCUITS - 6.0 A

- SINGLE-CONTACT INDUCTIVE LOAD INTERRUPTING CAPACITY: 125 V DC CIRCUITS - 1.0 A;

- RATED FOR 125 V DC OR 120 V AC; MEETS REQUIREMENTS OF NEMA ICS5; 10 A CONTACTS

AUXILIARY RELAYS:∙

600 V, 30 A MINIMUM, 90 ºC RATED TERMINATIONS.TERMINAL BLOCKS:∙

LIQUID-TIGHT HUBS.

APPLIED. OUTLET AND JUNCTION BOXES SHALL BE CAST ALUMINUM WITH CAST COVERS AND

NOT ALLOWED. ALL CONDUIT THREADED JOINTS SHALL HAVE A CONDUCTIVE JOINT COMPOUND

ALL WIRING TO BE RUN IN CONDUIT. WIRE RUNS THROUGH TANK REINFORCING CHANNELSCONDUIT:∙

PHASE C - YELLOW; GROUNDED NEUTRAL - WHITE; INSULATED GROUND - GREEN/YELLOW

XLPE; 3-PHASE POWER CONDUCTORS COLOR CODED: PHASE A - BROWN; PHASE B - ORANGE;WIRING:∙

COOLING FANS - 480 V AC, 3-WIRE, 3-PHASE, 60 HZ

CONTROL POWER - 125 V DC; ANNUNCIATION POWER - 125 V DC;GOVERNMENT-FURNISHED POWER:∙

SOLAR SHIELDING ON TOP, FRONT AND SIDE PANELS OF ENCLOSURES.

WINDOWS FOR VIEWING TEMPERATURE MONITOR AND ANNUNCIATOR IN CONTROL CABINET.

WEATHER-PROOF TYPE 304 STAINLESS STEEL WITH LOCKING PROVISIONS.CABINET MATERIAL:∙

A F P .0

G -0

.d g n

2.5 KV CLASS, 45 KV BIL, 100 AMPSFRA TEST SHIPPING BUSHING:∙

2.5 KV CLASS, 45 KV BIL, 100 AMPCORE GROUNDS:∙

TRANSFORMERS REQUIRED)

IMPREGNATED SYNTHETIC (RIS) CONDENSER CORE DESIGN (NO BUSHING CURRENT

25 KV CLASS, 150KV BIL, 400 AMP, COMPOSITE EXTERIOR WITH RESIN-NEUTRAL (H0):∙

0.3B-1.8 METERING ACCURACY, C400 RELAYING ACCURACY)

RESIN-IMPREGNATED SYNTHETIC (RIS) CONDENSER CORE DESIGN (ONE 1,200:5 MRCT,

25 KV CLASS, 150 KV BIL, 1,200 AMP, COMPOSITE EXTERIOR WITHPRIMARY WINDING (X):∙

0.3B-1.8 METERING ACCURACY, C400 RELAYING ACCURACY)

RESIN-IMPREGNATED SYNTHETIC (RIS) CONDENSER CORE DESIGN (TWO 600:5 MRCT,

138 KV CLASS, 650 KV BIL, 400 AMP, COMPOSITE EXTERIOR WITHSECONDARY WINDING (H):∙

∙ (QTY 1): VALVE OF EACH SIZE AND TYPE

∙ (QTY 1): PRESSURE REGULATOR FOR NITROGEN-GAS EQUIPMENT

∙ (QTY 1): FUSE OF EACH TYPE AND RATING

PLATE TO THE TRANSFORMER TEMPERATURE MONITOR FIBER-OPTIC MODULE

∙ (QTY 10): FIBER OPTIC EXTENSION CABLE THAT CONNECTS THE FEED-THROUGH WALL

∙ (QTY 3): COOLING FAN COMPLETE WITH MOTOR

∙ (QTY 1): BUSHING CURRENT TRANSFORMER OF EACH TYPE AND RATING

∙ (QTY 1): OIL TEMPERATURE INDICATOR

∙ (QTY 1): WINDING TEMPERATURE INDICATOR

∙ (QTY 1): LIQUID LEVEL INDICATOR

∙ (QTY 1): TRANSFORMER TEMPERATURE MONITOR MODULE OF EACH TYPE

∙ (QTY 1): ELECTRONIC PRESSURE MONITOR AND TWO PRESSURE TRANSDUCERS

∙ (QTY 1): PRESSURE RELIEF DEVICE

∙ (QTY 1): RELAY AND CONTACTOR OF EACH TYPE

∙ (QTY 1): COMPLETE GASKET SET

∙ (QTY 3): SET OF GASKETS FOR TRANSFORMER REASSEMBLY

∙ (QTY 1): 25 KV LOW-VOLTAGE WINDING BUSHING

∙ (QTY 1): 25 KV HIGH-VOLTAGE NEUTRAL BUSHING

∙ (QTY 1): 138 KV HIGH-VOLTAGE WINDING BUSHING

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N C

E

S H

E E

T

L A

Y O

U T A

N D L

IM

IT

IN

G D

IM

E N

S

IO

N S

G S

U T

R A

N S

F O

R M

E R

S

E-101

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /1

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

SEGMENT

3 HIGH-VOLTAGE (H) BUSHING

NOTES:

QTY

BILL OF MATERIALS

ITEM DESCRIPTION

1.5-INCH UPPER FILTER VALVE

JACK PAD (TYPICAL)

3-INCH VACUUM VALVE

RADIATOR (TYPICAL)

ANALOG TEMPERATURE GAUGES

RADIATOR ISOLATION VALVE

LIFTING EYE (TYPICAL)

SKID-TYPE STRUCTURAL BASE

HIGH-VOLTAGE NEUTRAL (H0) BUSHING

LOW-VOLTAGE (X) BUSHING

3 - COVER

2 - COVER

1 - COVER

OIL LEVEL INDICATOR

AS DES.

AS DES.

CONTROL CABINET

AS DES. THERMOWELLS

AS DES. TRANSFORMER NAMEPLATE LOCATION1

COVER

3-INCH MAIN OIL DRAIN VALVE

1.5-INCH LOWER FILTER VALVE

COVER

1.5-INCH ELECTRONIC PRESSURE MONITOR SENSORS VALVE

1,3

1,3

BUSHING SIDE)

(HIGH-VOLTAGE

SEGMENT 3

SEGMENT 2 SEGMENT 4

BUSHING SIDE)

(LOW-VOLTAGE

SEGMENT 1

FIGURE 1

IDENTIFICATION (TOP VIEW)

TRANSFORMER TANK SEGMENT

BRAND NAME OR EQUAL MODEL NUMBER

1 POWER CABINET

30 2-INCH GAS-IN-OIL MONITOR VALVE

33 1, COVER

ABB

ABB TYPE O-PLUS-DRY

ABB

QUALITROL XPRD

QUALITROL SERIES 104

930QUALITROLELECTRONIC PRESSURE MONITOR

PRESSURE RELIEF DEVICE WITH DISCHARGE PIPING

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

QUALITROL SERIES 042

NOT TO SCALE

ELEVATION - SEGMENT 1

NOT TO SCALE

PLAN - COVER

H1 H2 H3

X1 X2 X3

2 3

H1 H2 H3

X1 X2 X3H0

9 10

AS DES. 2,3,4

2,3,4

2,3,4

VERTICAL DRAFT COOLING FAN KRENZ-VENT SERIES F26

16 17

25 26

35 COVER MANHOLE ACCESS COVER

26" 18"18"

M A

X

IM

U M

M A

X

IM

U M

45 AS DES. COVER FALL ARREST SYSTEM MOUNTING BRACKET DBI-SALA 8517412

56"56"

1,3

STRUCTURAL BASE BRACKETS FOR WELDING BASE TO PAD (SHEET S-101)

PROTECTIVE COVER

CORE

(#4 AWG)

GROUNDING CABLE

BUSHING

CORE GROUND

GROUND BUSHING

CORE FRAME

TANK COVER

CORE FRAME

(#4 AWG)

GROUNDING CABLE

TANK COVER

CL

FIGURE 2

CORE AND CORE FRAME GROUNDING

H3

H2

X1

X2

X3

FIGURE 3

TERMINAL DESIGNATION

PHASE RELATION OF

H1

CORE & CORE FRAME GROUND BUSHINGS (SEE FIG. 2)

CL

12"CL

LC

LC

34-1/2"

69"

LOCATION AS INDICATED ON DRAWING G-003.

TRANSFORMER TANK BY A SEPARATE INSTALLATIONS CONTRACTOR, IN THE

THE NITROGEN REGULATOR CABINET WILL BE REMOTE MOUNTED FROM THE5.

DEVICE MANUFACTURER.

PORT TRANSDUCER MANIFOLD, IN A LOCATION AS RECOMMENDED BY THE

INSTALLED ON A FLANGED VALVE ON THE TANK UTILIZING A QUALTROL THREE-

A TOTAL OF THREE ELECTRONIC PRESSURE MONITOR TRANSDUCERS SHALL BE4.

QUANTITY OF RADIATORS OR FANS.

DIRECTION OF FAN AIR FLOW, AND ARE NOT INTENDED TO INDICATE THE ACTUAL

THE RADIATORS AS DEPICTED INDICATE THE PERMISSIBLE LOCATIONS AND THE3.

STRUCTURAL BASE REQUIREMENTS.

SEE DRAWING S-101 FOR THE MOUNTING PAD DETAILS AND TRANSFORMER2.

D. JACKING PADS AND STRUCTURAL BASE CHANNELS

C. ANCILLARY DEVICES

B. CONTROL AND POWER CABINETS

A. HIGH-VOLTAGE AND LOW-VOLTAGE BUSHINGS

PROPER INTERCONNECTION:

FOLLOWING ANCILLARY EQUIPMENT ARE CONSIDERED CRITICAL TO ASSURE

INTERCONNECTION TO THE EXISTING POWER PLANT. THE LOCATIONS OF THE

THE MANUFACTURER'S USE IN DESIGNING THE TRANSFORMERS FOR PROPER

THE TRANSFORMER LAYOUT AND LIMITING DIMENSIONS HAVE BEEN PROVIDED FOR1.

AS DES.

H0

NORMANDY MACHINE CO. 82-8001

TYPE O-PLUS-DRY

TYPE O-PLUS-DRY

A F P .0

E -1

.d g

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N C

E

S H

E E

T

L A

Y O

U T A

N D L

IM

IT

IN

G D

IM

E N

S

IO

N S

G S

U T

R A

N S

F O

R M

E R

S

E-102

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /2

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

NOTES:

FIGURE 1

IDENTIFICATION (TOP VIEW)

TRANSFORMER TANK SEGMENT

BUSHING SIDE)

(HIGH-VOLTAGE

SEGMENT 3

BUSHING SIDE)

(LOW-VOLTAGE

SEGMENT 1

SEGMENT 4 SEGMENT 2

ELEVATION - SEGMENT 3

NOT TO SCALE

NOT TO SCALE

ELEVATION - SEGMENT 4 ELEVATION - SEGMENT 2

NOT TO SCALE

SEGMENT

3 HIGH-VOLTAGE (H) BUSHING1

QTY

BILL OF MATERIALS

ITEM DESCRIPTION

1.5-INCH UPPER FILTER VALVE

JACK PAD (TYPICAL)

3-INCH VACUUM VALVE

RADIATOR (TYPICAL)

RADIATOR ISOLATION VALVE

LIFTING EYE (TYPICAL)

SKID-TYPE STRUCTURAL BASE

HIGH-VOLTAGE NEUTRAL (H0) BUSHING

LOW-VOLTAGE (X) BUSHING

3 - COVER

2 - COVER

1 - COVER

AS DES.

AS DES.

CONTROL CABINET

COVER

3-INCH MAIN OIL DRAIN VALVE

1.5-INCH LOWER FILTER VALVE

COVER

1,3

1,3

BRAND NAME OR EQUAL MODEL NUMBER

1 POWER CABINET

33 1, COVER

ABB

ABB TYPE O-PLUS-DRY

ABB

QUALITROL XPRDPRESSURE RELIEF DEVICE WITH DISCHARGE PIPING

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

AS DES. 2,3,4

2,3,4

2,3,4

VERTICAL DRAFT COOLING FAN KRENZ-VENT SERIES F26

1,3 STRUCTURAL BASE BRACKETS FOR WELDING BASE TO PAD (SHEET S-101)

2 3

16 17

26 25

CORE & CORE FRAME GROUND BUSHINGS AND ENCLOSURE

42 42

225" (MAXIMUM)

LOCATION AS INDICATED ON DRAWING G-003.

TRANSFORMER TANK BY A SEPARATE INSTALLATIONS CONTRACTOR, IN THE

THE NITROGEN REGULATOR CABINET WILL BE REMOTE MOUNTED FROM THE4.

QUANTITY OF RADIATORS OR FANS.

DIRECTION OF FAN AIR FLOW, AND ARE NOT INTENDED TO INDICATE THE ACTUAL

THE RADIATORS AS DEPICTED INDICATE THE PERMISSIBLE LOCATIONS AND THE3.

STRUCTURAL BASE REQUIREMENTS.

SEE DRAWING S-101 FOR THE MOUNTING PAD DETAILS AND TRANSFORMER2.

D. JACKING PADS AND STRUCTURAL BASE CHANNELS

C. ANCILLARY DEVICES

B. CONTROL AND POWER CABINETS

A. HIGH-VOLTAGE AND LOW-VOLTAGE BUSHINGS

PROPER INTERCONNECTION:

FOLLOWING ANCILLARY EQUIPMENT ARE CONSIDERED CRITICAL TO ASSURE

INTERCONNECTION TO THE EXISTING POWER PLANT. THE LOCATIONS OF THE

THE MANUFACTURER'S USE IN DESIGNING THE TRANSFORMERS FOR PROPER

THE TRANSFORMER LAYOUT AND LIMITING DIMENSIONS HAVE BEEN PROVIDED FOR1.

NORMANDY MACHINE CO. 82-8001

TYPE O-PLUS-DRY

TYPE O-PLUS-DRY

A F P .0

E -1

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N

P

W E

R A

N D C

O N

T R

O L C

A B

IN

E T S

E-103

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /1

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T

LEGEND:

NOTES:

SIDE VIEW

DETAIL OF VIBRATION ISOLATION MOUNTSPOWER AND CONTROL CABINETS

CABINET DOOR SEAL

DETAIL OF TYPICAL

CONNECTIONS AND GROUNDING

DETAIL OF ENCLOSURE CONDUIT

WINDOWS SEAL

TYPICAL CLAYTONRITE-TYPE

DETAIL "A"

CABINETS

POWER AND CONTROL

120 VAC & 125 VDC CONTROL CABINET480 VAC POWER CABINET

43TF 86T

TTM

TO POWER PLANT

CONNECTIONS

EXTERNAL CONDUIT

FUTURE

DOOR)

(INSIDE CABINET

DRAWING POCKET

O&M MANUAL

DOOR)

(INSIDE CABINET

COMPUTER TRAY

FOLD-DOWN

FRAMEWORK

CABINET MOUNTING

(SEE DETAIL 'A')

WINDOW SEAL

MOUNTS (TYPICAL)

VIBRATION ISOLATION

SIDEWALL

TRANSFORMER TANK

TEMPERED GLASS

RUBBER SEAL

ENCLOSURE PANEL

SECURING STRIP

DRIP SHIELD

RAIN AND

GASKET SEAL

DRIP CHANNEL

CABINET DOOR

SOLAR SHIELDING

GROUND WIRE

AND GROUNDING SCREW

WITH A CAPTIVE O-RING GASKET

SHALL BE A MYERS SCRU-TITE

ALL CONDUIT HUB FITTINGS

EQUIPMENT ENCLOSURE

TRANSFORMER TEMPERATURE MONITORTTM

LOCKOUT RELAY86T

COOLING GROUP ON-OFF-AUTO SELECTOR SWITCH43TF

TRANSFORMER TEMPERATURE MONITOR30

(BY SEPARATE INSTALLATION CONTRACTOR)

AND NITROGEN REGULATOR CABINET

CONNECTIONS TO GAS-IN-OIL MONITOR

TO HOLD THE O&M MANUAL DRAWINGS.

LATCHING THE TRAY WHEN STOWED. THE LEFT DOOR SHALL HAVE A POCKET SIZED

THE TRAY IN A HORIZONTAL POSITION WHEN LOWERED, AND A MEANS FOR

INSIDE OF THE DOOR. THE TRAY SHALL INCLUDE FOLDING HINGES WHICH SECURE

THE RIGHT DOOR SHALL HAVE A DROP DOWN LAPTOP TRAY MOUNTED ON THE7.

WHICH IS MOUNTED TO THE TRANSFORMER TANK USING VIBRATION ISOLATORS.

THE CONTROL AND POWER CABINETS SHALL BE MOUNTED TO A FRAME STRUCTURE6.

60 INCHES ABOVE THE BASE OF THE TRANSFORMER.

MOUNTED ON THE SWING PANELS SO THAT THE DEVICES ARE APPROXIMATELY

THE TRANSFORMER TEMPERATURE MONITOR AND ANNUNCIATOR SHALL BE5.

POWER CABINETS SHALL ONLY ENTER EACH CABINET THROUGH THE BASE.

ALL CONDUIT ROUTING FROM THE TRANSFORMER DEVICES TO THE CONTROL AND4.

PURPOSES OF FIELD FITTING OF CONDUIT.

THE BASE OF EACH CABINET SHALL HAVE GASKETED REMOVABLE PLATES FOR THE

REPRESENTATIVE PURPOSES ONLY. ACTUAL QUANTITIES AND SIZES WILL VARY.

EXTERNAL CONDUIT CONNECTIONS TO THE POWER PLANT ARE SHOWN FOR3.

SPACE FOR ARC FLASH LABEL (PROVIDED BY THE GOVERNMENT).2.

BUILT IN ACCORDANCE WITH UL 508A STANDARD.

THE TRANSFORMER CONTROL AND POWER CABINETS ARE TO BE DESIGNED AND1.

SEE NOTE 2

A F P .0

E -1

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N

L

Y O

U T

C O

N T

R O

L C

A B

IN

E T

E-104

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /2

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

CONTROL CABINET TOP VIEW

A F

B EC

G

D

DESCRIPTION BRAND NAME OR EQUAL MODEL NUMBER

QUALITROL QTMS

MOLDED-CASE CIRCUIT BREAKERS

AUXILIARY RELAYS

INTERPOSING RELAY FOR LOCKOUT RELAY GENERAL ELECTRIC

ELECTROSWITCH SERIES 24, MODEL 78PB02E

TERMINAL BLOCKS - CONTROL SIGNAL TYPE

TERMINAL BLOCKS - POWER DISTRIBUTION TYPE

FUSES

FUSE HOLDERS

CABINET HEATER

ELECTROSWITCH SERIES 24

UNDERVOLTAGE RELAY

RECEPTACLE WITH GROUND FAULT HUBBELL GFR8300SGW

MARATHON SERIES 142

TIME MARK

BUSSMAN

BUSSMAN

WAUKESHA PTC2

FAL

C26(XX)

HMA

LPJ

JTN600(XX)

TIME DELAY RELAY AGASTAT SERIES 7000

TRANSFORMER TEMPERATURE MONITOR

LOCAL ANNUNCIATOR PANELS (DEVICE 30) SEL 2533

ITEM

COOLING GROUP SELECTOR SW. (DEVICE 43TF)

TERMINAL BLOCKS - SHORT CIRCUIT

GROUND BUS BAR - -

QTY

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

BILL OF MATERIALS - CONTROL CABINET COMPONENTS

HUMIDISTAT / THERMOSTAT (DEVICE 23-1) HAMMOND MFG SKTH012009-C

STATES TYPE NT, CLASS 250

STATES TYPE NT, CLASS 251-G

SQUARE D

SQUARE D 8501, TYPE X

NOTES:

LH BACK PANEL RH BACK PANEL RH SIDE PANEL

(FRONT VIEW)

RIGHT SWING PANEL

BLOCKS

TERMINAL

RESISTORS

CALIBRATION

ANALOG WTI

BLOCKS

TERMINAL

BLOCKS

TERMINAL

BLOCKS

TERMINAL

TRANSFORMER

CURRENT

BLOCKS

TERMINAL

BREAKERS

CIRCUIT

DEVICES

RELAYS AND

AUXILIARY

BOTTOM PANEL

CONTROL CABINET LAYOUT

DEVICES

ASSOCIATED

TTM AND

QTMS

TRANSFORMER MONITORING SYSTEM

TEST

MENU

RESET

ENTER

B

A

C D E

F

G

HEATERHEATER

(FRONT VIEW)

LEFT SWING PANEL

LH SIDE PANEL

CABINET LIGHT

WIRING TO POWER CABINET

BUSHING FOR 120 VAC

WIREWAY HOLE WITH

5453 55 56

6352 64

59 62

(NOTE 3)

OUTLET

TRANSFORMER MOUNTED CONDUIT

AREA FOR INSTALLATION OF

INSTALLATION TO POWER PLANT

PLATE FOR CONDUIT

AND GASKETED BOTTOM

REMOVABLE BOLTED

58 57

65 67

59 62

59 62

LOCKOUT RELAY (DEVICE 86T)

LEGEND:

WINDING TEMPERATURE INDICATORWTI

59 62

THE REMOVABLE BOTTOM PLATE THICKNESS SHALL BE 10 GAUGE, MINIMUM.5.

CABINET.

THE GFCI OUTLET SHALL BE ACCESSIBLE ONLY FROM INSIDE THE CONTROL4.

PROOF VIEWING GLASS IN THE CONTROL CABINET DOOR.

ON THE SWING PANEL SO THAT THE FRONT IS VISIBLE THROUGH A WATER-

CHASSIS IN THE CONTROL CABINET, WITH HMI MODULES REMOTELY MOUNTED

THE TEMPERATURE MONITOR SHALL BE INSTALLED IN A REAR MOUNT3.

ONLY. THE ACTUAL LAYOUT MAY BE MODIFIED BY THE CONTRACTOR.

THE CONTROL CABINET LAYOUT AS SHOWN IS FOR ILLUSTRATIVE PURPOSES2.

AND BUILT IN ACCORDANCE WITH UL 508A STANDARD.

THE TRANSFORMER CONTROL AND POWER CABINETS ARE TO BE DESIGNED1.

A F P .0

E -1

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N

Y O

U T

V

A C P

O W

E R C

A B

IN

E T

E-105

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /3

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

DESCRIPTION BRAND NAME OR EQUAL MODEL NUMBER

MAGNETIC CONTACTORS

MOLDED-CASE CIRCUIT BREAKERS

TERMINAL BLOCKS - CONTROL SIGNAL TYPE

TERMINAL BLOCKS - POWER DISTRIBUTION TYPE

FUSES

FUSE HOLDERS

CABINET HEATER

MARATHON SERIES 142

BUSSMAN

BUSSMAN

WAUKESHA PTC2

KHL

LPJ

JTN600(XX)

QTYITEM

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

1 GROUND BUS BAR - -

AUXILIARY POWER TRANSFORMER - -

BILL OF MATERIALS - POWER CABINET COMPONENTS

HUMIDISTAT / THERMOSTAT (DEVICE 23-2) HAMMOND MFG SKTH012009-C

SQUARE D

STATES TYPE NT, CLASS 250

SQUARE D

NOTES:

BOTTOM PANEL

POWER CABINET LAYOUT

POWER CABINET - TOP VIEW

D

A C

B

D

AND FAN CONTROL)

LIGHTS, HEATER

(WIRING FOR

BLOCKS

TERMINAL

120 VAC

TRANSFORMER

POWER

AUXILIARY

52 71

CONTACTORS

FAN MOTOR

BREAKERS AND

CIRCUIT

BLOCKS

TERMINAL

BLOCKS

TERMINAL

LH SIDE PANEL RH SIDE PANELBACK PANELA B C

HEATER

CABINET LIGHT

INSTALLATION TO POWER PLANT

PLATE FOR CONDUIT

GASKETED BOTTOM

REMOVABLE BOLTED AND

TRANSFORMER MOUNTED CONDUIT

AREA FOR INSTALLATION OF

CABINET

WIRING TO CONTROL

BUSHING FOR 120 VAC

WIREWAY HOLE WITH

59 62

59 62

59 62

THE REMOVABLE BOTTOM PLATE THICKNESS SHALL BE 10 GAUGE, MINIMUM.3.

TERMINAL BLOCKS SHALL BE MOUNTED IN THE 480 VAC POWER CABINET.

INCLUDING THE MOLDED-CASE CIRCUIT BREAKERS, CONTACTORS AND POWER

ALL 480 VAC PROTECTIVE AND CONTROL EQUIPMENT FOR THE COOLING FANS,2.

MODIFIED BY THE CONTRACTOR.

THE LAYOUT SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY. THE LAYOUT MAY BE1.

A F P .0

E -1

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

L A

Y O

U T A

N D D

E T

A

IL

S

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N

A N

S F

O R

M E

R M

O U

N T

E D D

E V

IC

E S

E-106

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /4

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

(110 C)

SW. #2

(UNUSED)

SW. #1

(125 C)

SW. #3

PRESSURE

LOW

PRESSURE

HIGH

(UNUSED)

SW. #2

(UNUSED)

SW. #1

(< 200 PSI)

EMPTY CYLINDER

BULB

HEATER

WELL

BULB

HEATER

WELL

TB5:1 TB5:2 TB5:3 TB5:4 TB5:5 TB5:6

OUTPUT RELAY

GAS ALARM

T X

T X

R X

R X

S G

N D

LEGEND:

LOW VOLTAGE BUSHINGSX1,2,3

TRANSFORMER TEMPERATURE MONITORTTM

TEST SWITCHTS

TERMINAL BLOCKTB_

SWITCHSW

RESISTANCE TEMPERATURE DETECTORRTD

HIGH VOLTAGE BUSHINGSH1,2,3

HIGH VOLTAGE NEUTRAL BUSHINGH0

FAN CURRENT TRANSFORMERFCT

CURRENT TRANSFORMERCT

MULTI-RATIO BUSHING CURRENT TRANSFORMERBCT

GAS-IN-OIL MONITOR95Q

TRIP AUXILIARY RELAY94X

TRANSFORMER LOCKOUT RELAY86T

OIL LEVEL INDICATOR71Q

ELECTRONIC PRESSURE MONITOR63PM

PRESSURE RELIEF DEVICE63PR

NITROGEN PRESSURE REGULATOR63NR

ANALOG WINDING TEMPERATURE INDICATOR49WTI

CALIBRATION RESISTOR49R

HEATED THERMOWELLS49Q1,2

ANNUNCIATOR30

THERMOWELL26Q1,2,3

ANALOG OIL TEMPERATURE INDICATOR26Q

AMBIENT AIR TEMPERATURE26A

NOTES:

(BELOW)

DIAGRAM

SEE CT

(DEVICE 49Q1)

THERMOWELL

HEATED

TOP OIL THERMOWELLS

(DEVICE 49Q2)

WITH NPT PLUG

THERMOWELL

SPARE HEATED

(DEVICE 26Q1)

THERMOWELL

(DEVICE 26Q2)

THERMOWELL

(WITH NPT PLUG)

THERMOWELL

SPARE

(DEVICE 49WTI)

WINDING TEMPERATURE INDICATOR

(DEVICE 26Q)

OIL TEMPERATURE INDICATOR

BOTTOM OIL THERMOWELL

(DEVICE 26Q3)

THERMOWELL

(DEVICE 26A)

AMBIENT TEMPERATURE RTD

MODULE

INPUT

ANALOG

TTM

MODULE

INPUT

ANALOG

TTM

MODULE

INPUT

ANALOG

TTM

(DEVICE 30)

ANNUNCIATION

(DEVICE 94X)

TRANS. TRIP

(DEVICE 63PR)

PRESSURE RELIEF DEVICE

(DEVICE 95Q)

GAS-IN-OIL MONITOR

(DEVICE 30)

ANNUNCIATION

(DEVICE 30)

ANNUNCIATION

(DEVICE 94X)

TRANSFORMER TRIP

SENSOR #1

PRESSURE

SENSOR #2

PRESSURE

SENSOR #3

PRESSURE

(DEVICE 63PM)

ELECTRONIC PRESSURE MONITOR

RISE

FAST PRESSURE

RISE

SLOW PRESSURE

(DEVICE 30)

ANNUNCIATION

TO TTM (TB2)

COMMUNICATIONS

RS-485

(49WTI)

HEATER

THERMOWELL

(SPARE)

HEATER

THERMOWELL

(SEE NOTE 1)

ANALOG INPUT MODULE

TTM

HEATED THERMOWELLS

CURRENT TRANSFORMERS AND

WINDINGS ASSEMBLY

TRANSFORMER CORE AND

(TYPICAL)

SEE NOTE 2

BCT-H1

BCT-H4

BCT-H2

BCT-H5

BCT-H3

BCT-H6

BCT-H0

CT-X2 49R

49Q1

49Q2

(BELOW)

DIAGRAM

SEE CT

H1 H2 H3

H0 X1 X2 X3

H1

H0

H3

H2

X1

X3

X2

INPUT 4

INPUT 3INPUT 2INPUT 1

RTD3RTD2RTD1

2 31 4 5 6 7 8 9

95Q-CT

TTM-CT

TERMINALS

LOADGUIDE

(DEVICE 63NR) (SEE NOTE 3)

NITROGEN PRESSURE REGULATOR

BCT-X1 BCT-X2 BCT-X3

INSTALLATIONS CONTRACTOR, IN THE LOCATION AS INDICATED ON DRAWING G-003.

BUT WILL BE REMOTE MOUNTED FROM THE TRANSFORMER TANK BY A SEPARATE

THE NITROGEN REGULATOR CABINET IS TO BE PROVIDED UNDER THIS CONTRACT,3.

ON SHORTING TERMINAL BLOCKS.

SECONDARY WIRING IS TO BE ROUTED TO THE CONTROL CABINET AND TERMINATED

ALL BUSHING CURRENT TRANSFORMERS AND CURRENT TRANSFORMER2.

CONNECTION DETAILS.

SEE DRAWINGS E-603 AND E-604 FOR TRANSFORMER TEMPERATURE MONITOR1.

(ALARM)

SW. #1

(DEVICE 94X)

TRANS. TRIP

(TRIP)

SW. #2

(DEVICE 30)

ANNUNCIATION

(DEVICE 71Q)

OIL LEVEL INDICATOR

(LOW LEVEL)

SW. #1

(CRITICAL LOW LEVEL)

SW. #2

(DEVICE 30)

ANNUNCIATION

B C

O E D

E S

IG

N

TS

3 12 6 4 5 8 9 7

(DEVICE 30)

ANNUNCIATION

A F P .0

E -1

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N

V

A C C

O N

T R

O L S

C H

E M

A T

IC

V

A C C

O O

L

IN

G S

C H

E M

A T

IC

E-601

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /1

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T

52-1

PDB1

DS-1

H T

R

1 2

LT1 LT2

43TF

23-1

NC NO

DS-2

NC NO

H T

R

LT3

23-2

DS-3

NC NO

LIGHTS

CABINET

CONTROL

52-6

HEATER

CABINET

CONTROL

52-7

27-1

27-1

FUSES

LIGHT

CABINET

POWER

52-3

HEATER

CABINET

POWER

52-4

52-2

480 VAC, 3-PHASE, 60 HZ

GOVERNMENT SUPPLIED POWER

FUSE 86T

3X

TTM

TB1:2

TB1:3

3X

3X

49-1

L

FCT

POWER CABINET

LOCATED IN 480 VAC

480 VAC POWER CABINET

LOCATED IN

POWER CABINET

LOCATED IN 480 VAC

480 VAC COOLING SCHEMATIC

TO TTM

FAN CURRENT

(RLY 1)

ROM

49T1

H T

SEE NOTE 8

OFF POSITION

O F F

X

X

CONTACTS

(O N

(A U

T O

ON AUTO

20A

GFCI

OUTLET

P D

B

RECEPTACLE

CABINET

CONTROL

52-8

P D

B

(DEV. 95Q)

POWER

MONITOR

GAS-IN-OIL

43TF - SWITCH DEVELOPMENT

LINE

NEUTRAL

V

A C -P

H A

S E H

Z

G O

V E

R N

M E

N T S

U P

P L

IE

D C

O N

T R

O L P

O W

E R

MONITOR

PRESSURE

ELECTRONIC

52-10

120 VAC CONTROL SCHEMATIC

(DEV. 63NR)

POWER

REGULATOR

PRESSURE

NITROGEN

REGULATOR

PRESSURE

NITROGEN

52-11

(DEV. 63PM)

HEATER

MONITOR

PRESSURE

ELECTRONIC

LEGEND:

NOTES:

TRANSFORMER TEMPERATURE MONITORTTM

TERMINAL BLOCK CONNECTIONTB

POWER DISTRIBUTION BLOCKPDB

TRANSFORMER TEMPERATURE MONITOR RELAY OUTPUT MODULEROM

CABINET LIGHTLT

CABINET HEATERHTR

GROUND FAULT CIRCUIT INTERRUPTERGFCI

FAN CURRENT TRANSFORMERFCT

CABINET DOOR SWITCHDS

GAS-IN-OIL MONITOR95Q

FAN MOTOR88

TRANSFORMER LOCKOUT RELAY86T

ELECTRONIC PRESSURE MONITOR63PM

NITROGEN PRESSURE REGULATOR63NR

AC MOLDED-CASE CIRCUIT BREAKER52-

WINDING TEMPERATURE49T1

COOLING GROUP ON-OFF-AUTO SELECTOR SWITCH43TF

COOLING GROUP MOTOR CONTACTOR42

ANNUNCIATOR30

COOLING CONTROL AUXILIARY RELAY3X

INDUSTRIAL GRADE HUMIDISTAT / THERMOSTAT23

(SEE NOTE 9)

MONITOR

GAS-IN-OIL

52-9

(SEE NOTE 6)

GROUP

COOLING

A F P .0

E -6

.d g n

X1

V

V

H4

H1 X3

SHEILD

ELECTROSTATIC

SPECIFICATIONS SECTION 48 29 23.04 26, PARAGRAPH 2.14.4.

THE AUXILIARY POWER TRANSFORMER SHALL MEET THE REQUIREMENTS OF10.

MONITOR.

IN THE TRANSFORMER CONTROL CABINET AS A SOURCE OF POWER TO THIS

BY A SEPARATE INSTALLATIONS CONTRACTOR. PROVIDE A BREAKER

THE GAS-IN-OIL MONITOR (SERVERON TM8) WILL BE PROVIDED AND INSTALLED9.

OF THE CABINET PROVIDED.

THE ACTUAL QUANTITY OF HEATERS MAY VARY DEPENDING UPON THE SIZE8.

IN THE ENERGIZED STATE.

THE TTM RELAY CONTACT 1 IS A FAILSAFE CONTACT SHOWN WITH THE TTM7.

PROTECTION.

ALL FANS SHALL HAVE BUILT-IN AUTOMATIC-RESET THERMAL OVERLOAD6.

AUXILIARY POWER TRANSFORMER.

120 VAC POWER TO REDUCE THE REQUIRED RATING AND SIZE OF THE

THE GFCI RECEPTACLE IS SOURCED FROM THE GOVERNMENT FURNISHED5.

EACH COOLING GROUP.

MANUFACTURER. ONE FAN CURRENT TRANSFORMER SHALL BE PROVIDED FOR

THE FAN CURRENT TRANSFORMER SHOWN SHALL BE PROVIDED BY THE TTM4.

GOVERNMENT FURNISHED.

AND 120 VAC POWER SOURCES INDICATED IN THE DASHED BOXES ARE

THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AS INDICATED. THE 480 VAC3.

THE ACTUAL CONFIGURATION PROVIDED.

ARE FOR SCHEMATIC REPRESENTATION ONLY AND MAY NOT BE INDICATIVE OF

THE QUANTITY AND GROUPING OF COOLING FANS AND CONTACTORS AS SHOWN2.

OR ROUTED THROUGH THE MAIN CONTROL CABINET.

NO 480 VAC EQUIPMENT OR ASSOCIATED WIRING SHALL BE INSTALLED INSIDE1.

(SEE NOTE 10)

480VAC - 120VAC

POWER TRANSFORMER

AUXILIARY

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N

V

D C C

O N

T R

O L S

C H

E M

A T

IC

C O

N T

R O

L C

A B

IN

E T

E-602

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

F P -5 .0

-6 -9

A /2

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

LEGEND:

NOTES:

RATING OF THESE DEVICE CONTACTS.

CONTACTS, AS THE BURDEN OF THE LOCKOUT RELAY SOLENOID EXCEEDS THE

86T LOCKOUT RELAY WITHOUT OVERLOADING THE 63PM AND TTM OUTPUT RELAY

THE PURPOSE OF THE 94X AUXILIARY RELAY IS TO ALLOW FOR TRIPPING OF THE2.

THE TTM WINDING OVER-TEMPERATURE TRIP, SET AT A 5C HIGHER TEMPERATURE.

THE ANALOG WINDING TEMPERATURE INDICATOR SHALL BE USED AS A BACKUP TO1.

72-1

D

B

P D

B

94X

PR

86T

NOTE 2)

(SEE

TRIP COIL MONITORING

LOCKOUT RELAY WITH

86T

HR

R

G

86T

86T

G TB4

B

94X

94X

RESET

TRIP (TO POWER PLANT)

63PM

POWER

125 VDC

HEATER

120 VAC

TB3

(63PM1)

TRIP

PRESSURE

FAST

(63PM2)

ALARM

PRESSURE

SLOW

TB5

SENSOR #1

PRESSURE

SENSOR #2

PRESSURE

SENSOR #3

PRESSURE

CONTROL

COOLING

TTM

72-3

125VDC

POWER

TTM

TB1-14

TB1-15

V D

C G

O V

E R

N M

E N

T F

U R

N

IS

H E

D C

O N

T R

O L P

O W

E R

63PM 94X 86T

30 (LOCKOUT COIL TROUBLE)

30 (XFMR LOCKOUT)

125 VDC CONTROL SCHEMATIC

120C

TTM

TB1:11

TB1:12

(RLY 4)

ROM

49T3

52-10

E-601

SEE SHEET

125C

WTI

TRANSFORMER TEMPERATURE MONITORTTM

RELAY OUTPUT MODULE (TTM)ROM

POWER DISTRIBUTION BLOCKPDB

HAND RESET (DEVICE 86T)HR

TRIP AUXILIARY RELAY94X

LOCKOUT RELAY (HAND RESET)86T

DC MOLDED-CASE CIRCUIT BREAKER72

PRESSURE RELIEF DEVICE63PR

ELECTRONIC PRESSURE MONITOR63PM

ANALOG WINDING TEMPERATURE INDICATOR49WTI

WINDING TEMPERATURE49T

COOLING GROUP MOTOR CONTACTOR42

ANNUNCIATOR30

A F P .0

E -6

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N C

E

S H

E E

T

F U

N C

T

IO

N A

L R

E Q

U

IR

E M

E N

T S

T R

A N

S F

O R

M E

R T

E M

P E

R A

T U

R E M

O N

IT

O R

E-603

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /3

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

(NEOPTIX T2)

WINDINGS

SENSORS TO

FIBER OPTIC

TB1

RS 485

TB2

REMOTE DISPLAY

TB3

ETHERNET

MAIN

TB4

RS 485

TB5

FX

ETHERNET

TB6

COMMUNICATIONS BOARD

CPU MODULE

TEMPERATURE MODULES

DIRECT FIBER OPTIC

MODE

FAILSAFE

RELAY SETPOINT

105C3

95C

FAILSAFE

___ A

COOLING FANS ON

WINDING OVERTEMP

(SEE NOTE 2)

TOP OIL OVERTEMP

COOLING TROUBLE

INPUT

WTI-F/O

WTI-F/O

OTI-RTD

FCT

NON-FAILSAFE

NON-FAILSAFE

AND WALL PLATE

TANK WALL OPTICAL FEEDTHROUGH

WINDING TEMP TRIPNON-FAILSAFEWTI-F/O120C

TEMPERATURE MONITOR RELAY SETTINGS

ANALOG DIGITAL RELAY

TB1

TB2

TB1 TB1

TB2 TB2

FIBER FIBERCPU

5TX+

TX1

RX+

RX-

SGND

TX+

TX1

RX+

RX-

SGND

RELAY

STATUS

TB7 1

NC

C

NO

24 VDC

POWER

MAIN

TB8

TO TTM MODULES

SENSOR CONNECTORS

FIBER OPTIC

MODULE

INPUT

ANALOG

MODULE

INPUT

DIGITAL

MODULE

OUTPUT

RELAY

(LV WINDINGS) (HV WINDINGS)(SEE NOTE 1)

(SEE NOTE 1)

HMI MODULE

QTMS

TRANSFORMER MONITORING SYSTEM

ENTER

TEST

MENU

RESET

TRANSFORMER TEMPERATURE MONITORING SYSTEM

NOTES:

LEGEND:

PLATE (QUALITROL PLT-201)

WELD-ON TANK STAINLESS STEEL

(QUALITROL COV-121-1)

JUNCTION BOX

(QUALITROL CON-159-1)

TERMINATIONS (QTY. 12)

OPTICAL FEEDTHROUGH

TANK WALL

(QUALITROL CAB-700)

CABLES (QTY. 12)

FIBER OPTIC EXTENSION

TEMPERATURE MONITOR HOT-SPOT MODULES.

CABLES SHALL CONNECT FROM THIS TANK WALL PLATE DOWN TO THE

JUNCTION BOX LOCATED ON THE OUTSIDE TANK WALL. FIBER OPTIC EXTENSION

DESIGNED FOR 12 OPTICAL FEEDTHROUGHS, WHICH IS PROTECTED BY A

TANK SHALL CONNECT TO AN OPTICAL FEED-THROUGH TANK WALL PLATE

SECTION 48 19 23.04 26, PARAGRAPH 2.15.2.3. THE FIBER OPTIC PROBES IN THE

INSTALLED, IN THE WINDING LOCATIONS AS REQUIRED IN SPECIFICATIONS

A TOTAL OF 12 FIBER OPTIC WINDING TEMPERATURE PROBES SHALL BE3.

RISE AS DETERMINED DURING THE FACTORY ACCEPTANCE TESTS.

(CONTACT 49T1) SHALL CORRESPOND TO THE 100% RATED LOAD TEMPERATURE

THE TEMPERATURE SETPOINT FOR ENERGIZING THE COOLING FANS2.

CABINET DOOR.

IS VISIBLE THROUGH A WATERPROOF VIEWING GLASS IN THE CONTROL

MOUNTED ON THE SWING PANEL DOOR (SEE DRAWING E-103), SO THAT IT

CHASSIS IN THE CONTROL CABINET. THE HMI MODULE SHALL BE REMOTELY

THE TEMPERATURE MONITOR SHALL BE INSTALLED IN A REAR MOUNT1.

DESCRIPTION

WINDING TEMPERATURE INDICATORWTI

TRANSFORMER TEMPERATURE MONITORTTM

TERMINAL BLOCKTB

OIL TEMPERATURE INDICATOROTI

FIBER OPTICF/O

FAN CURRENT SENSING TRANSFORMERFCT

GAS-IN-OIL MONITOR95Q

TRANSFORMER LOCKOUT RELAY86T

WINDING TEMPERATURE CONTACT49T

CONTACTOR42

ANNUNCIATOR30

OIL OVERTEMPERATURE26Q

A F P .0

E -6

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N C

E

S H

E E

T

F U

N C

T

IO

N A

L R

E Q

U

IR

E M

E N

T S

T R

A N

S F

O R

M E

R T

E M

P E

R A

T U

R E M

O N

IT

O R

E-604

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /4

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

TB1

MODULE TERMINAL BLOCK FUNCTION

CPU MODULE - COMMUNICATIONS BOARD

TB2

TB3

TB4

TB5

TB6

TB7

TB8

ANALOG INPUT MODULE

24 VDC POWER SUPPLY

INPUT 1 (TERM. 1,2,3)

INPUT 2 (TERM. 4,5,6)

INPUT 3 (TERM. 7,8,9)

INPUT 4 (TERM. 10,11,12)

INPUT 5 (TERM. 13,14,15)

INPUT 6 (TERM. 16,17,18)

INPUT 7 (TERM. 19,20,21)

INPUT 8 (TERM. 22,23,24)

DIGITAL INPUT MODULE

INPUT 1 (TERM. 1,2)

INPUT 2 (TERM. 3,4)

INPUT 3 (TERM. 5,6)

INPUT 4 (TERM. 7,8)

INPUT 5 (TERM. 9,10)

INPUT 6 (TERM. 11,12)

INPUT 7 (TERM. 13,14)

INPUT 8 (TERM. 15,16)

INPUT 9 (TERM. 17,18)

INPUT 10 (TERM. 19,20)

INPUT 11 (TERM. 21,22)

INPUT 12 (TERM. 23,24)

INPUT 13 (TERM. 25,26)

INPUT 14 (TERM. 27,28)

RELAY OUTPUT MODULE

OUTPUT 1 (TERM. 1,2,3)

OUTPUT 2 (TERM. 4,5,6)

OUTPUT 3 (TERM. 7,8,9)

OUTPUT 4 (TERM. 10,11,12)

OUTPUT 5 (TERM. 13,14,15)

OUTPUT 6 (TERM. 11,17,18)

OUTPUT 8 (TERM. 22,23,24)

OUTPUT 7 (TERM. 19,20,21)

ST CONNECTOR 1

ST CONNECTOR 2

ST CONNECTOR 3

ST CONNECTOR 4

ST CONNECTOR 5

ST CONNECTOR 6

ST CONNECTOR 7

ST CONNECTOR 8

ST CONNECTOR 1

ST CONNECTOR 2

ST CONNECTOR 3

ST CONNECTOR 4

ST CONNECTOR 5

ST CONNECTOR 6

ST CONNECTOR 7

ST CONNECTOR 8

49T1 - FAN CONTACTOR (DEVICE 42)

49T3 - WINDING OVERTEMPERATURE TRIP (DEVICE 94X)

TOP OIL TEMPERATURE SENSOR (RTD)

LOW VOLTAGE BUSHING CURRENT TRANSFORMER SENSING

LV WINDING, A-PHASE (FIBER F01)

LV WINDING, A-PHASE (FIBER F02)

LV WINDING, B-PHASE (FIBER F03)

LV WINDING, B-PHASE (FIBER F04)

LV WINDING, C-PHASE (FIBER F05)

LV WINDING, C-PHASE (FIBER F06)

HV WINDING, A-PHASE (FIBER F07)

HV WINDING, A-PHASE (FIBER F08)

HV WINDING, B-PHASE (FIBER F09)

HV WINDING, B-PHASE (FIBER F10)

HV WINDING, C-PHASE (FIBER F11)

HV WINDING, C-PHASE (FIBER F12)

CURRENT LP 1 (TERM. 25,26)

CURRENT LP 2 (TERM. 27,28)

BOTTOM OIL TEMPERATURE SENSOR (RTD)

26Q - OIL HIGH TEMPERATURE (DEVICE 30)

49T2 - WINDING HIGH TEMPERATURE (DEVICE 30)

COOLING GROUP TROUBLE (DEVICE 30)

TTM TROUBLE (DEVICE 30)

LOW VOLTAGE WINDINGS

DIRECT FIBER OPTIC TEMPERATURE MODULE

HIGH VOLTAGE WINDINGS

DIRECT FIBER OPTIC TEMPERATURE MODULE

MODBUS INTERCONNECTION WITH GAS-IN-OIL MONITOR (DEVICE 95Q)(NOTE 2)

CONNECTION TO REMOTE MOUNTED HMI MODULE

FCT - COOLING FAN CURRENT SENSING (CT)

AMBIENT AIR TEMPERATURE SENSOR (RTD)

TRANSFORMER TEMPERATURE MONITOR FUNCTIONAL REQUIREMENTS

LEGEND:

NOTES:

WINDING TEMPERATURE INDICATORWTI

TRANSFORMER TEMPERATURE MONITORTTM

TERMINAL BLOCKTB

OIL TEMPERATURE INDICATOROTI

FAN CURRENT SENSING TRANSFORMERFCT

GAS-IN-OIL MONITOR95Q

TRANSFORMER LOCKOUT RELAY86T

WINDING TEMPERATURE CONTACT49T

CONTACTOR42

ANNUNCIATOR30

OIL OVERTEMPERATURE26Q

A SEPARATE INSTALLATIONS CONTRACT.

INTERCONNECTIONS, WILL BE PROVIDED AND INSTALLED BY OTHERS UNDER

THE GAS-IN-OIL MONITOR (SERVERON TM8), AND ANY REQUIRED2.

LAYOUT.

SEE SHEET E-603 FOR THE TRANSFORMER TEMPERATURE MONITOR FUNCTIONAL1.

A F P .0

E -6

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N

E E

T

A N

N U

N C

IA

T O

R F

U N

C T

IO

N A

L R

E Q

U

IR

E M

E N

T S

E-605

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /5

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

G1

IN

G2

IN

A1

IN

A2

IN

B1

IN

B2

IN

C1

IN

C2

IN

D1

IN

D2

IN

E1

IN

E2

IN

F1

IN

F2

IN

+1

-2 INPUT

IRIG-B

P R

O G

R A

M M

A B

L E O

P T

O

IS

O L

A T

E D I

N P

U T S

1 2

FRONT PANEL ALARM LED

A

B

C

D

E

CONTROLS

FRONT PANEL OPERATOR

SIL ACK RESET TEST

OUT 01

OUT 02

ALARM

OUT 03

OUT 04

OUT 05

OUT 06

OUT 07

OUT 15

THROUGH

OUT 08

P R

O G

R A

M M

A B

L E O

U T P

U T C

O N

T A

C T S

1 2 3 4 5

EIA-485

PORT 4A

EIA-232

PORT 4C

T

X

T

X

R

X

R

X

S H

L D

OPTIONAL CARD

EIA-485 OR EIA-232

GND

SUPPLY

POWER

+/H

-/N

GROUND

CHASSIS

PORTS

STANDARD EIA-232

EIA-232

EIA-232

IRIG-B

EIA-232

PORT F (FRONT)

PORT 2 (REAR)

PORT 3 (REAR)

P D

B

72-2

P D

B

A N

N U

N C

IA

T

IO

N P

O W

E R

V D

C G

O V

E R

N M

E N

T F

U R

N

IS

H

TRANSFORMER LOCKOUT

86T

86T COIL MON

LOCKOUT COIL TROUBLE

95C

OIL HIGH TEMPERATURE

LOCKOUT

TRANSFORMER

TROUBLE

LOCKOUT COIL

TEMPERATURE

OIL HIGH

TEMP - FIBER

WINDING HIGH

105C

WINDING HIGH TEMP - FIBER

110C

X WINDING HIGH TEMP - GAUGE

TEMP - GAUGE

X WINDING HIGH

71Q

LOW OIL LEVEL

LOW OIL LEVEL

71Q

LOW OIL LEVEL - CRITICAL

CRITICAL

LOW OIL LEVEL

63PR

PRESSURE RELIEF DEVICE

RELIEF DEVICE

PRESSURE

49T WTI

49T2 (TTM ROM RELAY 3)

(SEE SHEET E-606)

TO DEVICE 30-2

(SEE SHEET E-606)

TO DEVICE 30-2

LEGEND:

26Q (TTM ROM RELAY 2)

63NR

NITROGEN LOW PRESSURE

63NR

NITROGEN EMPTY CYLINDER

EMPTY CYLINDER

NITROGEN

LOW PRESSURE

NITROGEN

DEVICE 30-1, 125 VDC ANNUNCIATOR SCHEMATIC

TRANSFORMER TEMPERATURE MONITORTTM

TROUBLETRBL

RELAY OUTPUT MODULE (TTM)ROM

POWER DISTRIBUTION BLOCKPDB

MONITORMON

TRANSFORMER GAS-IN-OIL MONITOR95Q

LOCKOUT RELAY (HAND RESET)86T

DC MOLDED-CASE CIRCUIT BREAKER72

OIL LEVEL INDICATOR71Q

PRESSURE RELIEF DEVICE63PR

ELECTRONIC PRESSURE MONITOR63PM

NITROGEN PRESSURE REGULATOR63NR

ANALOG WINDING TEMPERATURE INDICATOR49WTI

WINDING TEMPERATURE49T

COOLING GROUP MOTOR CONTACTOR42

ANNUNCIATOR30

COOLING CONTROL UNDERVOLTAGE RELAY27-1

OIL HIGH TEMPERATURE (TTM)26Q

A F P .0

E -6

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N

E E

T

A N

N U

N C

IA

T O

R F

U N

C T

IO

N A

L R

E Q

U

IR

E M

E N

T S

E-606

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /6

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

G1

IN

G2

IN

A1

IN

A2

IN

B1

IN

B2

IN

C1

IN

C2

IN

D1

IN

D2

IN

E1

IN

E2

IN

F1

IN

F2

IN

+1

-2 INPUT

IRIG-B

P R

O G

R A

M M

A B

L E O

P T

O

IS

O L

A T

E D I

N P

U T S

1 2

FRONT PANEL ALARM LED

A

B

C

D

E

CONTROLS

FRONT PANEL OPERATOR

SIL ACK RESET TEST

OUT 01

OUT 02

ALARM

OUT 03

OUT 04

OUT 05

OUT 06

OUT 07

OUT 15

THROUGH

OUT 08

P R

O G

R A

M M

A B

L E O

U T P

U T C

O N

T A

C T S

1 2 3 4 5

EIA-485

PORT 4A

EIA-232

PORT 4C

T

X

T

X

R

X

R

X

S H

L D

OPTIONAL CARD

EIA-485 OR EIA-232

GND

SUPPLY

POWER

+/H

-/N

GROUND

CHASSIS

PORTS

STANDARD EIA-232

EIA-232

EIA-232

IRIG-B

EIA-232

PORT F (FRONT)

PORT 2 (REAR)

PORT 3 (REAR)

GAS MONITOR TROUBLE

95Q

TROUBLE

GAS MONITOR

LOSS OF CONTROL POWER

52-2

27-1

C0NTROL POWER

LOSS OF

TTM STATUS ALARM

TTM CPU TB7

ALARM

TTM STATUS

LEGEND:

(SEE SHEET E-605)

TO DEVICE 30-1

(SEE SHEET E-605)

TO DEVICE 30-1

COOLING GROUP TROUBLE

TTM ROM RELAY 5

GROUP TROUBLE

COOLING

TRANSFORMER TEMPERATURE MONITORTTM

RELAY OUTPUT MODULE (TTM)ROM

POWER DISTRIBUTION BLOCKPDB

TRANSFORMER GAS-IN-OIL MONITOR95Q

AC MOLDED-CASE CIRCUIT BREAKER52

ANNUNCIATOR30

COOLING CONTROL UNDERVOLTAGE RELAY27-1

NOTE:

A SEPARATE INSTALLATIONS CONTRACT.

INTERCONNECTIONS, WILL BE PROVIDED AND INSTALLED BY OTHERS UNDER

THE GAS-IN-OIL MONITOR (SERVERON TM8), AND ANY REQUIRED1.

DEVICE 30-2, 125 VDC ANNUNCIATOR SCHEMATIC

FAN POWER

LOSS OF 480V

LOSS OF 480V FAN POWER

A F P .0

E -6

.d

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

M A

IN

U

N

IT

T

R A

N S

F O

R M

E R

A L

B E

N I F

A L L S P

R O J E

C T

A N

S I

D

D F

IL

E R

K F

L O

R E

N

X

T E

R N

A L C

O N

N E

C T

IO

N S

C O

N T

R O

L A

N D P

O W

E R C

A B

IN

E T S

E-607

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

S E

A T

T L E

W A

S H

IN

G T

O N

S E

A T

T L E D

IS

T R

O E D

E S

IG

N

P O

W E

R H

O U

S E

K O

O T

E N

A I

R

IV

E V

E N R

M

IL

E S P .E

A F P -5 .0

-6 -9

A /7

D F

IL

E R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

TERMINAL BLOCKS - CONTROL SIGNAL TYPE

TERMINAL BLOCKS - POWER DISTRIBUTION TYPE MARATHON SERIES 142

AS REQ'D

AS REQ'D

AS REQ'D

TERMINAL BLOCKS - SHORT CIRCUIT

DESCRIPTION BRAND NAME OR EQUAL MODEL NUMBERQTYITEM

STATES TYPE NT, CLASS 250

STATES TYPE NT, CLASS 251-G

TERMINAL BLOCKS FOR EXTERNAL CONNECTIONS TO POWER PLANT

BILL OF MATERIALS

PDB1

FAN POWER

POWER

ANNUNCIATION

PDB4

ANNUNCIATION

CTB2

TRANS LOCKOUT

OIL HIGH TEMPERATURE

CONTROL

CTB1

TRANS LOCKOUT TRIPP67B

POWER

DC CONTROL

PDB3

POWER

120 VAC

PDB2

GROUND

GROUND

GROUND

STB1

STB2

STB3

H11X1

H11X2

H11X3

H11X4

H11X5

H21X1

H21X2

H21X3

H21X4

H21X5

H31X1

H31X2

H31X3

H31X4

H31X5

GROUND

GROUND

GROUND

STB4

STB5

STB6

H12X1

H12X2

H12X3

H12X4

H12X5

H22X1

H22X2

H22X3

H22X4

H22X5

H32X1

H32X2

H32X3

H32X4

H32X5

(L)

(N)

125 VDC CONTROL POWER

120 VAC CONTROL POWER

A

B

C

3-WIRE

480 VAC, 3-PHASE,

FAN POWER SUPPLY

FOR EXTERNAL CONNECTIONS

TERMINAL BLOCKS

POWER CABINET

125 VDC ANN. POWER

LEGEND:

SHORTING TERMINAL BLOCK (CT WIRING)

POWER DISTRIBUTION BLOCK

CONTROL TERMINAL BLOCK

BUSHING CURRENT TRANSFORMER

NOTES:

STB

PDB

CTB

BCT

GROUND

GROUND

GROUND

STB7

STB8

STB9

X11X1

X11X2

X11X3

X11X4

X11X5

X21X1

X21X2

X21X3

X21X4

X21X5

X31X1

X31X2

X31X3

X31X4

X31X5

MULTI-RATIO

600:5 BCT #1

TO H1

MULTI-RATIO

600:5 BCT #1

TO H2

MULTI-RATIO

600:5 BCT #1

TO H3

MULTI-RATIO

600:5 BCT #2

TO H1

MULTI-RATIO

600:5 BCT #2

TO H2

MULTI-RATIO

600:5 BCT #2

TO H3

MULTI-RATIO

1,200:5 BCT #1

TO X1

MULTI-RATIO

1,200:5 BCT #1

TO X3

MULTI-RATIO

1,200:5 BCT #1

TO X2

CONTRACT…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.