W912DR18Q0028_Solicitation_032918.pdf
PDF 972 KB Posted
- Attached to
- WAD PHOSPHORIC ACID-75% Federal contract opportunity
- Solicitation number
- W912DR18Q0028
About this file
Furnish all of the Washington Aqueducts Phosphoric Acid (Orthophosphate) 75% (H3PO4) in accordance with these specifications. This will be an IDIQ type of contract.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| DR18Q0028_Amendment_One_042018.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE ADDENDUM
(No Collect Calls)
W912DR18Q0028 29-Mar-2018
b. TELEPHONE NUMBER
410-962-5626
8. OFFER DUE DATE/LOCAL TIME
12:00 PM 28 Apr 2018
5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV. 2/2012)
Prescribed by GSA – FAR (48 CFR) 53.212
(TYPE OR PRINT)
(SIGNATURE OF CONTRACTING OFFICER)
ADDENDA ARE
26. TOTAL AWARD AMOUNT (For Gov t. Use Only )
23.
CODE 10. THIS ACQUISITION IS
SUCH ADDRESS IN OFFER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT
BELOW IS CHECKED
TELEPHONE NO.
W912DR9. ISSUED BY
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME
LA SHURA M JOHNSON
2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER
(TYPE OR PRINT)
30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER
30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA
27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.
25. ACCOUNTING AND APPROPRIATION DATA
1. REQUISITION NUMBER
20.
ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.
OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
. YOUR OFFER ON SOLICITATION
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
% FOR:SET ASIDE:UNRESTRICTED OR X
SMALL BUSINESSX
17a.CONTRACTOR/ CODE FACILITY
OFFEROR CODE
USACE, BALTIMORE DISTRICT
2 HOPKINS PLAZA
ROOM 03-G-01
BALTIMORE MD 21201
18a. PAYMENT WILL BE MADE BY CODE
RATED ORDER UNDER
DPAS (15 CFR 700)
13a. THIS CONTRACT IS A
13b. RATING
CODE15. DELIVER TO CODE 16. ADMINISTERED BY
SEE SCHEDULE
12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-
TION UNLESS BLOCK IS
MARKED
SEE SCHEDULE
14. METHOD OF SOLICITATION
RFQ IFB RFPX
FAX:
TEL: 410-962-2196
SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
8(A)
HUBZONE SMALL
BUSINESS
SIZE STANDARD:
1,000
NAICS:
325180
X
OFFER DATED
29. AWARD OF CONTRACT: REF.
DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND
EMAIL:
TEL:
31c. DATE SIGNED
SEE SCHEDULE
SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT
24.22.21.19.
WOMEN-OWNED SMALL BUSINESS (WOSB)
ELIGIBLE UNDER THE WOMEN-OWNED
SMALL BUSINESS PROGRAM
EDWOSB
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
(CONTINUED)
PAGE 2 OF47
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
32b. SIGNATURE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
37. CHECK NUMBER
FINALPARTIALCOMPLETE
36. PAYMENT35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER
FINAL
33. SHIP NUMBER
PARTIAL
38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE
42a. RECEIVED BY (Print)
42b. RECEIVED AT (Location)
42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS
STANDARD FORM 1449 (REV. 2/2012) BACK
Prescribed by GSA – FAR (48 CFR) 53.212
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
SEE SCHEDULE
20.
SCHEDULE OF SUPPLIES/ SERVICES
21.
QUANTITY UNIT
22. 23.
UNIT PRICE
24.
AMOUNT
19.
ITEM NO.
Section SF 30 - BLOCK 14 CONTINUATION PAGE
INSTRUCTIONS TO OFFERORS
PROPOSAL PREPARATION INSTRUCTIONS
The Offerors shall submit technical and price quotes in two volumes. Technical proposal shall not contain any pricing information.
In both volume, the Offeror shall identify primary and alternate points of contact for this effort. The information shall include: the name of the POC, office telephone numbers, email and email addresses. Both volumes shall easily identify the Offerors CAGE Code, DUNS and Federal Tax Identification Number.
Volume I – Technical Proposal
Volume I shall include all technical information in response to evaluation factor I as stated in the Evaluation
Criteria document. This volume shall not exceed 10 pages excluding tables of contents, charts, tables, figures, schedules or cover page. Text shall be no smaller than 11 font, single spaces on 8.5 x 11 size paper. Past
Performance Questionnaire documentation is excluded from the page count.
Volume II – Price Proposal
Volume II shall include the price schedule included in this solicitation. Supporting documentation may be submitted for price and costs elements. There is no page limitation for this volume. Any assumptions made regarding price shall be included in this volume.
Organizational Conflict of Interest (OCI): Pursuant to Federal Acquisition Regulation (FAR) Subpart 9.5, all potential or real Organizational Conflicts of Interest (OCI)’s must be identified and evaluated as early in the acquisition. The offeror shall provide a certification that to the best of its knowledge and belief, that it is not aware of any existing potential organizational conflict of interest. If the offeror is aware of any existing potential organization conflict of interest, the contractor shall provide disclosure of the potential organization conflict of interest and a mitigation plan in its proposal for evaluation by the Government. If the Contracting Officer determines that a potential conflict exists, the offeror shall not receive award unless the OCI is resolved. All OCIs that may arise during the performance of this effort shall be disclosed to the Government as soon as identified.
REQUESTS FOR INFORMATION
The Government will honor Requests for Information regarding this procurement. Should the Offeror choose to submit questions, questions must be received by the Contract Specialist via email no later than 12:00 PM EST on
Tuesday, 10 April 2018.
PROPOSAL SUBMISSION INSTRUCTIONS
Reference the Bid Submittal information in section 4 a-b of the Statement of Work. Offers shall be prepared in accordance with these instructions, providing all required information in the specified format. If any exceptions or deviations to the solicitation requirements are taken, these exceptions shall be clearly noted in the offeror’s cover letter. Quotes shall be submitted via email ONLY to the Contract Specialist, Ms. Tolu Olojo, see block 8 of the
SF1449. The Offeror shall request and document timely submission of proposal from the Contract Specialist the time of submission. Official submission will be documented in accordance with the date and time stamp of the email submission.
EVALUATION CRITERIA
I. INTRODUCTION
The intent for this Request for Quote is to solicit quotes for a contract to fulfill the requirements of the Scope of
Work attached to this solicitation. The Washington Aqueduct Dalecarlia Water Treatment Plant has a requirement for Phosphoric Acid for use at the Washington Aqueduct’s water treatment plant (WTP), Dalecarlia WTP
Offeror’s are required to meet all solicitation requirements, including terms and conditions, representations and certifications, and technical requirements, in addition to those identified as evaluation factors.
Offerors shall submit in their proposal all requested information specified in this section of the solicitation at or before the exact time specified. If an Offeror believes that the requirements in these instructions contain and error, ambiguity, omission or are otherwise unsound, the Offeror shall immediately notify the Contracting Officer in writing with supporting rationale.
In accordance with FAR Subpart 4.8 (Government Contract Files), the Government will retain one copy of all unsuccessful quotes.
II. BASIS OF AWARD
The Government will award this contract on a Lowest Price Technically Acceptable (LPTA) basis. The Contract will be consist of a five (5) year ordering period. The contract type is Firm Fixed Price, Indefinite Delivery
Indefinite Quantity Contract.
The evaluation factors are as follows:
Factor I – Technical Capability: the Offeror must provide information as specified in the attached Scope of Work.
Each submittal will be evaluated to ensure requirements are met.
Factor II – Past Performance: An acceptable rating is required to be considered for award. The Offeror must provide information demonstrating that they have already successfully performed as a prime contractor within the last five (5) years of at least two (2) chemical contracts of equal or greater complexity to this solicitation in the minimum price range of $100,000 - $500,000. This information shall be submitted on the Past Performance Contacts
Questionnaire (attached) and information requested on this document must be submitted. The Offeror shall submit at least two references, including point of contact name, email address and phone number, that can verify past performance listed in this paragraph. This shall be submitted directly to the Contract Specialist via email at tolulope.o.olojo@usace.army.mil. Failure to do so will deem Offeror non-responsive.
The Past Performance Questionnaire included in this solicitation is provided for the Offeror or its team members to submit to the Contract Specialist for each project the Offeror includes in its proposal for Factor 2 – Past
Performance. Ensure correct phone numbers and email addresses are provided for the client point of contact.
Completed Past Performance Questionnaires (PPQ) should be submitted with your proposal. If the Offeror is unable to obtain a completed PPQ from a client for a project(s) before solicitation closing date, the Offeror should complete and submit with the quote the first page of the PPQ, which will provide contract and client information for the respective project(s). Offerors should follow-up with clients/references to ensure timely submittal of questionnaires.
Questionnaires may be submitted directly to the Contract Specialist (via email) at least 2 days prior to the solicitation closing date. Offerors shall not incorporate by reference into their proposal PPQs previously submitted for other RFQs. However, this does not preclude the Government’s from utilizing previously submitted PPQ information in the past performance evaluation.
Offerors may include performance recognition documents received within the last 5 years such as awards, award fee determinations, customer letters of commendation, and any other forms of performance recognition.
The Government may review any other sources available to retrieve past performance information. Other sources may include, but are not limited to, ast Performance Retrieval System (PPIRS), including Contractor Performance
Assessment Reporting System (CPARS), using all CAGE/DUNS numbers of team members (partnership, joint mailto:tolulope.o.olojo@usace.army.mil venture, teaming arrangement, or parent company/subsidiary/affiliate) identified in the Offeror’s proposal, inquiries of owner representative(s), Federal Awardee Performance and Integrity Information System (FAPIIS), Electronic
Subcontract Reporting System (eSRS), and any other known sources not provided by the Offeror.
While the Government may elect to consider data from other sources, the burden of providing detailed, current, accurate and complete past performance information rests with the Offeror.
Factor III – Offerors shall insert proposed pricing in the Price Schedule, proposing a price on all proposed items.
The unit prices shall include all markups for providing the specified Sodium Hypochlorite requirements. Markups are defined as all other direct and indirect costs, management, supervision, contractor furnished equipment, material, and supplies, travel, overhead and profit.
The absence of any information required to support the evaluation factors herein and as described below will result in disqualification from competition, as that offer will be found non-responsive and unacceptable. To receive consideration for award, a rating of no less than “Acceptable” must be achieved for the Factors I and II.
III. EVALUATION RATINGS
The following ratings, as defined, will be assessed to the evaluations factors as indicated below.
FACTOR I – Technical Capability
Rating Definition
Acceptable Proposal clearly meets the minimum requirements of the RFQ
Unacceptable Proposal does not clearly meet the minimum requirements of the RFQ
FACTOR II – Past Performance
Rating Definition
Acceptable
Based on the Offeror’s performance record, the
Government has a reasonable expectation that the
Offeror will successfully perform the required effort, or the Offeror’s performance record is unknown. *
Unacceptable
Based on the Offeror’s performance record, the
Government has no reasonable expectation that the
Offeror will be able to successfully perform the required effort.
* Note: In the case of an Offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the
Offeror may not be evaluated favorably or unfavorably on past performance. Therefore, the Offeror shall be determined to have unknown past performance. In the context of acceptability/unacceptability, “unknown” shall be considered “neutral.”
FACTOR III – Price
Price will be evaluated based on technical acceptability and price reasonableness.
ORDERING PROCEDURES
H.1 Indefinite Delivery Indefinite Quantity (IDIQ) Single Award Contracts
a. The contract type is an Indefinite Delivery, Indefinitely Quantity (IDIQ) Single Award Task Order
Contract (SATOC), pursuant to FAR Part 16. Task orders will be issued on a Firm Fixed Price.
b. The Government intends to evaluate proposals and award on IDIQ SATOC, as a small business set aside.
c. The minimum guarantee is $3,000. The Basis of Award for the SATOC is Lowest Price.
d. Contract Rates: The Contractor shall use the contract rates established on the Price schedule on all task orders under the base IDIQ. The Contractor may propose less than the contract rate on task orders, but must not exceed the rates established on the base IDIQ contract.
e. Performance shall be authorized only by issuance of task orders by the Government Contracting Office; the procedures are discussed in H.2 Ordering Procedures, in the Section titled “Special Contracting
Requirements” in the solicitation. No work will be performed before a written and signed (by a warranted
Contracting Officer) task order. Task orders may be issued by facsimile or electronic mail (e-mail).
f. Except for the limitations stated FAR 52.216-19, there is no limit on the number or size of task orders that may be issued except that a task order or (multiple task orders) may not be issued over the IDIQ contract capacity. This contract shall be used for work at the Washington Aqueducts sites only.
Task orders must be issued within the ordering period of the base IDIQ. The task order period may extend beyond the end of the ordering period. However, issuance of a new task order may not occur after the expiration of the base ordering period. The ordering period shall not exceed five (5) years.
h. The North American Industry Classification System (NAICS) code for the acquisition is 325180 – All other basic organic chemical manufacturing with a size standard of 1000 employees.
H.2 Ordering Procedures
a. The Government shall have the right to award task orders in the cumulative amount of up to 3300 dry tons during the life of this contract.
b. The Contracting Officer will notify the SATOC holder of an existing requirement by issuing a delivery order, specifying quantity of delivery and delivery date.
c. The time set for delivery will be set in each delivery order.
d. Task orders will be issued by a Contracting Officer using a Department of Defense form 1155. Each task order will include the following information at a minimum:
(1) Date of delivery order
(2) Contract and delivery order numbers
(3) Fixed price of the delivery order
(4) Delivery requirements
(5) Accounting and appropriation data
PRICE SCHEDULE
PHOSPHORIC ACID
Price Schedule
CLIN Description Annual
Quantity
Unit of measure Unit Price Total
Phosphoric Acid, Bulk
Dalecarlia
360 Dry Ton $ $
Phosphoric Acid, Bulk
McMillian
300 Dry Ton $ $
Dalecarlia
360 Dry Ton $ $
Phosphoric Acid, Bulk
Dalecarlia
360 Dry Ton $ $
Phosphoric Acid, Bulk
Dalecarlia
360 Dry Ton $ $
Phosphoric Acid, Bulk
Dalecarlia
360 Dry Ton $ $
Dalecarlia
360 Dry Ton $ $
TOTAL for Year Five (5)
3,300 Dry Ton Grand
Total
The contract capacity shall not exceed 3,300 dry tons for the five (5) year period of performance.
PAST PERFORMANCE PPQ
NAVFAC/USACE PAST PERFORMANCE QUESTIONNAIRE (Form PPQ-0)
CONTRACT INFORMATION (Contractor to complete Blocks 1-4)
1. Contractor Information
Firm Name: CAGE Code:
Address: DUNs Number:
Phone Number:
Email Address:
Point of Contact: Contact Phone Number:
2. Work Performed as: Prime Contractor Sub Contractor Joint Venture Other (Explain)
Percent of project work performed:
If subcontractor, who was the prime (Name/Phone #):
3. Contract Information Contract Number:
Delivery/Task Order Number (if applicable):
Contract Type: Firm Fixed Price Cost Reimbursement Other (Please specify):
Contract Title:
Contract Location:
Award Date (mm/dd/yy):
Contract Completion Date (mm/dd/yy):
Actual Completion Date (mm/dd/yy):
Explain Differences:
Original Contract Price (Award Amount):
Final Contract Price (to include all modifications, if applicable):
Explain Differences:
4. Project Description:
Complexity of Work High Med Routine
How is this project relevant to project of submission? (Please provide details such as similar equipment, requirements, conditions, etc.)
CLIENT INFORMATION (Client to complete Blocks 5-8)
5. Client Information
Name:
Title:
Phone Number:
Email Address:
6. Describe the client’s role in the project:
7. Date Questionnaire was completed (mm/dd/yy):
8. Client’s Signature:
ADJECTIVE RATINGS AND DEFINITIONS TO BE USED TO BEST REFLECT
YOUR EVALUATION OF THE CONTRACTOR’S PERFORMANCE
RATING DEFINITION NOTE
(E) Exceptional Performance meets contractual requirements and exceeds many to the Government/Owner’s benefit.
The contractual performance of the element or sub-element being assessed was accomplished with few minor problems for which corrective actions taken by the contractor was highly effective.
An Exceptional rating is appropriate when the Contractor successfully performed multiple significant events that were of benefit to the
Government/Owner. A singular benefit, however, could be of such magnitude that it alone constitutes an Exceptional rating.
Also, there should have been NO significant weaknesses identified.
(VG) Very Good Performance meets contractual requirements and exceeds some to the Government’s/Owner’s benefit. The contractual performance of the element or sub-element being assessed was accomplished with some minor problems for which corrective actions taken by the contractor were effective.
A Very Good rating is appropriate when the Contractor successfully performed a significant event that was a benefit to the
Government/Owner. There should have been no significant weaknesses identified.
(S) Satisfactory Performance meets minimum contractual requirements. The contractual performance of the element or sub-element contains some minor problems for which corrective actions taken by the contractor appear or were satisfactory.
A Satisfactory rating is appropriate when there were only minor problems, or major problems that the contractor recovered from without impact to the contract.
There should have been NO significant weaknesses identified. Per DOD policy, a fundamental principle of assigning ratings is that contractors will not be assessed a rating lower than Satisfactory solely for not performing beyond the requirements of the contract.
(M) Marginal Performance does not meet some contractual requirements. The contractual performance of the element or sub-element being assessed reflects a serious problem for which the contractor has not yet identified corrective actions. The contractor's proposed actions appear only marginally effective or were not fully implemented.
A Marginal is appropriate when a significant event occurred that the contractor had trouble overcoming which impacted the Government/Owner.
(U)
Unsatisfactory
Performance does not meet most contractual requirements and recovery is not likely in a timely manner. The contractual performance of the element or sub-element contains serious problem(s) for which the contractor's corrective actions appear or were ineffective.
An Unsatisfactory rating is appropriate when multiple significant events occurred that the contractor had trouble overcoming and which impacted the
Government/Owner. A singular problem, however, could be of such serious magnitude that it alone constitutes an unsatisfactory rating.
(N) Not
Applicable
No information or did not apply to your contract Rating will be neither positive nor negative.
TO BE COMPLETED BY CLIENT
PLEASE CIRCLE THE ADJECTIVE RATING WHICH BEST REFLECTS
YOUR EVALUATION OF THE CONTRACTOR’S PERFORMANCE.
1. QUALITY:
a) Quality of technical data/report preparation efforts E VG S M U N
b) Ability to meet quality standards specified for technical performance
E VG S M U N
c) Timeliness/effectiveness of contract problem resolution without extensive customer guidance
d) Adequacy/effectiveness of quality control program and adherence to contract quality assurance requirements (without adverse effect on performance)
2. SCHEDULE/TIMELINESS OF PERFORMANCE:
a) Compliance with contract delivery/completion schedules including any significant intermediate milestones. (If liquidated damages were assessed or the schedule was not met, please address below)
b) Rate the contractor’s use of available resources to accomplish tasks identified in the contract
3. CUSTOMER SATISFACTION:
a) To what extent were the end users satisfied with the project? E VG S M U N
b) Contractor was reasonable and cooperative in dealing with your staff
(including the ability to successfully resolve disagreements/disputes;
responsiveness to administrative reports, businesslike and communication)
c) To what extent was the contractor cooperative, businesslike, and concerned with the interests of the customer?
d) Overall customer satisfaction E VG S M U N
4. MANAGEMENT/ PERSONNEL/LABOR
a) Effectiveness of on-site management, including management of subcontractors, suppliers, materials, and/or labor force?
b) Ability to hire, apply, and retain a qualified workforce to this effort E VG S M U N
c) Government Property Control E VG S M U N
d) Knowledge/expertise demonstrated by contractor personnel E VG S M U N
e) Utilization of Small Business concerns E VG S M U N
f) Ability to simultaneously manage multiple projects with multiple disciplines E VG S M U N
g) Ability to assimilate and incorporate changes in requirements and/or priority, including planning, execution and response to Government changes
h) Effectiveness of overall management (including ability to effectively lead, manage and control the program)
5. COST/FINANCIAL MANAGEMENT
a) Ability to meet the terms and conditions within the contractually agreed price(s)?
b) Contractor proposed innovative alternative methods/processes that reduced E VG S M U N cost, improved maintainability or other factors that benefited the client
c) If this is/was a Government cost type contract, please rate the Contractor’s timeliness and accuracy in submitting monthly invoices with appropriate back-up documentation, monthly status reports/budget variance reports, compliance with established budgets and avoidance of significant and/or unexplained variances (under runs or overruns)
d) Is the Contractor’s accounting system adequate for management and tracking of costs? If no, please explain in Remarks section.
Yes No
e) If this is/was a Government contract, has/was this contract been partially or completely terminated for default or convenience or are there any pending terminations? Indicate if show cause or cure notices were issued, or any default action in comment section below.
f) Have there been any indications that the contractor has had any financial problems? If yes, please explain below.
6. SAFETY/SECURITY
a) To what extent was the contractor able to maintain an environment of safety, adhere to its approved safety plan, and respond to safety issues?
(Includes: following the users rules, regulations, and requirements regarding housekeeping, safety, correction of noted deficiencies, etc.)
b) Contractor complied with all security requirements for the project and personnel security requirements.
7. GENERAL
a) Ability to successfully respond to emergency and/or surge situations
(including notifying COR, PM or Contracting Officer in a timely manner regarding urgent contractual issues).
b) Compliance with contractual terms/provisions (explain if specific issues) E VG S M U N
c) Would you hire or work with this firm again? (If no, please explain below) Yes No
d) In summary, provide an overall rating for the work performed by this contractor.
Please provide responses to the questions above (if applicable) and/or additional remarks.
Furthermore, please provide a brief narrative addressing specific strengths, weaknesses, deficiencies, or other comments which may assist our office in evaluating performance risk (please attach additional pages if necessary):
SPECIFICATIONS - SOW
SPECIFICATIONS - SCOPE OF WORK
PHOSPHORIC ACID (ORTHOPHOSPHATE) – 75%
(H3PO4) (BULK LIQUID)
26 March 2018
Summary This is a requirements contract for the supplies specified and effective for the period stated, in the CLIN(s). The quantities of supplies specified in the CLIN(s) are estimates only and are not purchased by this contract. Except as this contract may otherwise provide, if the Government’s requirements do not result in orders in the quantities described as “estimated’’ or “maximum” in the CLIN(s), that fact shall not constitute the basis for an equitable price adjustment.
Delivery or performance shall be made only as authorized by orders issued in accordance with the Ordering clause. Subject to any limitations in the Order Limitations clause or elsewhere in this contract, the Contractor shall furnish to the Government all supplies specified in the CLIN(s) and called for by orders issued in accordance with the Ordering clause.
The summary table references the location of specific information within this Scope of Work. The Contractor must comply with all requirements listed herein, regardless of inclusion in the summary table.
Section(s)
Chemical name Phosphoric Acid 1, 6
Strength 75% as H3PO4 1, 6a
Projected annual quantity 660 Dry tons 3
Unit of measure for invoicing Dry tons 13a
Delivery form (tote vs. bulk) Bulk 8
Delivery load size 45,000 pounds (wet) 8b
NSF/ANSI Certification 60 7
Physical/chemical requirements Various 6
Bid submittal requirements See section 4
Contract award submittal requirements See section 5
Delivery requirements See sections 8-12
Delivery documentation See section 8g
1 Requirement – Furnish all of the Washington Aqueduct’s Phosphoric Acid (Orthophosphate) 75%
(H3PO4) in accordance with these specifications. This will be an IDIQ type of contract. Phosphoric Acid is used at Washington Aqueduct’s two water treatment plants (WTP’s), Dalecarlia WTP and McMillan
WTP. Phosphoric Acid shall conform to the requirements of NSF/ANSI Standard 60.
2 Period of Performance – IDIQ type contract, Five (5) calendar years
3 Government Projected Requirements:
Dalecarlia WTP: Approximately 360 dry tons per year. Estimated quantity of 1,800 dry tons during the entire period of performance.
McMillan WTP: Approximately 300 dry tons per year. Estimated quantity of 1,500 dry tons during the entire period of performance.
The total contract capacity shall not exceed 3,300 dry tons for the five (5) year period of performance.
4 Proposal Submittal -a Proposal Submittal shall include the following information:
Information to be Submitted with Proposal
1. A product information sheet (product bulletin) issued by the product manufacturer.
2. A certified laboratory report for a representative sample of product demonstrating compliance of the Contractor’s product with the requirements of Section 6 (Physical / Chemical
Requirements).
3. Certification by a certification organization accredited by the American National Standards
Institute stating that product meets the NSF/ANSI Standard 60 for addition to drinking water.
4. A safety data sheet (SDS) that complies with paragraph (g) of 29 CFR 1910.1200.
5. Offeror shall respond with written statement on company letterhead signed by company official that says, “Contractor is able to provide an uninterrupted supply of Phosphoric
Acid to Washington Aqueduct.”
6. Information demonstrating past performance as described in paragraph (c) of this section.
b. If the product of more than one facility or manufacturer may be supplied to fulfill this contract, the information described in Section 4a must be submitted for each separate facility and manufacturer.
Any request to change the product and/or manufacturer during the contract period must be submitted for approval to Contracting Officer’s Representative and no change shall be made without a modification to the contract executed by the contracting officer.
5 Information Required Upon Contract Award -a The following information is required to be provided to the individuals listed below no later than 14 days after contract award:
TO BE FILLED IN AT CONTRACT AWARD
Information Required Upon Contract Award
Sales Office Information Address
Email Address
Telephone number(s)
Normal working hours
Responsible personnel
Ordering Office
Information
Telephone number(s)
During working hours
During non-working hours
Email address
Normal working hours
Responsible personnel
Sales Office Address
Information Email Address
Telephone Number(s)
Normal Working Hours
Responsible Personnel
Ordering Office
Information
Telephone Number(s)
During Working Hours
During Non-Working Hours
Email Address
Normal Working Hours
Responsible Personnel
Technical Services
Department Information
Address
Email Address
Telephone number(s)
Normal working hours
Responsible personnel
Chemical-Emergency
Assistance (24 hours a day)
Telephone number(s)
Responsible personnel
Product Information for the
Chemical Supplied
Product information bulletin from product manufacturer
Certification from accredited certification organization of compliance with NSF/ANSI 60
Safety Data Sheet (SDS) that complies with paragraph (g) of 29
CFR 1910.1200
b The Contractor shall provide a completed, signed Accident Prevention Plan in accordance with Part
1910, Title 29 of the Code of Federal Regulations and EM 385-1-1, 15 Sep 08, for approval. A template is provided as Appendix A.
c Prior to the first chemical delivery and each time there is a change in dispatcher and/or delivery personnel the Contractor shall forward the following information to the individuals listed below in section 5d:
TO BE FILLED IN AT CONTRACT AWARD
Information Required Upon Change in Dispatcher and/or Delivery Personnel
Dispatcher Information Address
Email Address
Telephone number(s)
Normal working hours
Responsible personnel
Cargo Trailer Operator
Documentation
Names and photographs of the cargo trailer operators making deliveries d Prior to the first chemical delivery and each time there is a change in dispatcher and/or delivery personnel the Contractor shall forward the following information to the individuals listed below
Washington Aqueduct
Dalecarlia Water Treatment Plant
5900 MacArthur Blvd. NW
Washington, DC 20016-2514
Title Name Phone Email
COR Alexander Gorzalski 202 764-0037 Alexander.S.Gorzalski@usace.army.mil
Chief, Dalecarlia Section J. Woody Peterson 202 764-0009 John.W.Peterson@usace.army.mil
Foreman, Dalecarlia Sec. Ricky Davie 202 764-2729 Ricky.A.Davie@usace.army.mil
Plant Ops Engineer Anne Spiesman 202 764-2703 Anne.L.Spiesman@usace.army.mil
McMillan Water Treatment Plant
2500 First Street NW, Washington, DC 20001
Chief, McMillan Section L. Jay Nolan 202 764-0169 Leo.j.nolan@usace.army.mil
Foreman, McMillan Sec. Mark Aronhalt 202 764-0168 Mark.a.aronhalt@usace.army.mil
6 Physical / Chemical Requirements – a Phosphoric Acid supplied shall conform to the following requirements:
Physical / Chemical Characteristics
Parameter Minimum Required Maximum Allowed
Specific Gravity and Reference Temperature 1.574 at 25 degrees C 1.65
Density, lbs/gal 13.1 13.2
Equivalent H3PO4 Content, % (w/w) 75.0 --
Freezing Point, degrees C -17.5 4.6 b The Phosphoric Acid supplied shall be in liquid form.
c The Phosphoric Acid supplied shall contain no soluble material or organic substances in quantities capable of producing harmful health effects on those consuming water properly treated with the orthophosphate.
d Phosphoric Acid supplied shall be mixed prior to delivery. Mixing in the delivery truck is prohibited.
e Phosphoric Acid supplied shall not precipitate out during normal handling and storage.
7 Quality Assurance Requirements – a Certification of Suitability for Drinking Water – Phosphoric Acid supplied under this contract is a direct additive used in the treatment of potable water and shall be certified as suitable for treatment of drinking water by an accredited certifying organization in accordance with the requirements of the National
Sanitation Foundation / American National Standards Institute Standard 60 (NSF/ANSI Standard 60), Drinking Water Treatment Chemicals—Health Effects.
b Maximum Usage Level (MUL) for NSF/ANSI Standard 60 certification shall be greater than or equal to
12 mg/L.
c Certification shall be performed by a certification organization accredited by the American National
Standards Institute, and evaluation shall be accomplished in accordance with requirements that are no less restrictive than those listed in NSF/ANSI Standard 60.
d Contractor shall inform Washington Aqueduct that certification has been revoked or has lapsed within 7 days of the time the Contractor receives oral or written notification from the certification organization.
Loss of certification after Contract award shall constitute sufficient grounds for termination of the
Contract by the Government.
8 Ordering Procedures –
As the need exists for performance under the terms of this contract, the Contracting Officer will issue a delivery order. The authorized representative(s) of the Washington Aqueduct shall call in shipments against the delivery order not to exceed the required amount as reflected on the delivery order.
Delivery– Note: This is an IDIQ type of contract
a. The authorized representative(s) of the Washington Aqueduct will coordinate delivery date, time, and specific quantities required with the Contractor one (1) week in advance of the required delivery date.
b. Quantity - The Contractor shall make Phosphoric Acid deliveries upon request, in single-unit tank trucks, in quantities of 45,000 pounds (wet), plus or minus 10%. Tank trucks shall be weighed prior to each delivery and the net weight of delivered product, in pounds, shall be machine stamped on each delivery ticket.
c. Tote Bin Retrieval - Not applicable to deliveries of Phosphoric Acid.
d. Cargo Trailer Enclosure - Not applicable to deliveries of Phosphoric Acid.
e. All delivery drivers shall possess a valid commercial driver’s license with the proper Hazardous Material
(HAZMAT) endorsements accepted by District of Columbia. All delivery personnel must have company cell phones to facilitate deliveries.
f. Security Tags – Each tank truck unloading hose coupling, manway, and hatch shall be sealed and include a security tag number (see NSF/ANSI Standard 60 Section 3.9.3.1). The security tag numbers shall be e-mailed to Washington Aqueduct personnel below after each cargo trailer has been loaded and is ready for shipping.
Deliveries to the Dalecarlia WTP
Dalecarlia Water Treatment Plant
5900 MacArthur Blvd. NW, Washington, DC 20016
Chief, Dalecarlia Section J. Woody Peterson 202 764-0009 John.W.Peterson@usace.army.mil
Foreman, Dalecarlia Sec. Ricky Davie 202 764-2729 Ricky.A.Davie@usace.army.mil
Deliveries to the McMillan WTP
McMillan Water Treatment Plant
2500 First Street NW, Washington, D.C. 20001
Chief, McMillan Section L. Jay Nolan 202 762-0169 Leo.j.nolan@usace.army.mil
Foreman, McMillan Sec. Mark Aronhalt 202 762-0168 Mark.a.aronhalt@usace.army.mil
McMillan Filter Operators McMillan Operator 202 762 -0165 operator@usace.army.mil g Documentation Required for Each Delivery-
The Contractor shall email the personnel listed I (f) above the following information prior to each delivery leaving the manufacturing facility:
1. Chemical Product Name/Manufacturer Name
2. Bill of Lading Numbers
3. Departure Date & Time
4. Expected Delivery Date & Time
5. Hauler’s Company Name
6. Driver/Operator’s Name and Driver’s License State and Number
7. Truck License Number
8. Cargo Trailer License Number
9. Seal Numbers For All Hatches and Doors
Upon arrival at the facility, the cargo trailer operator shall present to on-site personnel the following items:
1. Bill of Lading including lot number or identification of the specific load of chemical delivered.
2. Machine stamped weight certificate
3. Certified manufacturer’s laboratory report for the specific load of chemical delivered. The report shall contain the following data.
a Date of Manufacture b Date of Shipment c Equivalent H3PO4 Content, % (w/w) d Specific Gravity and Reference temperature h The Contractor shall notify the control room (Dalecarlia telephone 202-764-2700 and the email recipients (as listed above in item 8F) of any changes in the driver, cargo trailer, and or delivery schedule.
i Routine Deliveries – The Phosphoric Acid delivery shall be between 0700 and 1400 hours Monday through
Friday except federal holidays. Any exception to this requirement must be approved by one of the individuals listed in Section 5d.
j Emergency Deliveries - Emergency deliveries may be required within 24 hours after notification and might include holiday and night hours.
k In the event that the load is rejected, the Contractor shall have 24 hours to supply another shipment. In the event that the Contractor is unable or unwilling to supply another shipment within this time period, Washington Aqueduct has the right to procure a shipment from another source.
l Holding time prior to delivery - Not applicable to delivery of Phosphoric Acid.
m The Contractor is responsible for assuring delivery quantities do not exceed the current funded purchase order.
n All deliveries of Phosphoric Acid shall be freight prepaid, F.O.B. to the following Government facilities:
Washington Aqueduct
Dalecarlia Water Treatment Plant 5900
MacArthur Blvd., N.W.
Washington, D.C. 20016-2514
And
Washington Aqueduct
McMillan Water Treatment Plant
2500 First Street NW, Washington, D.C. 20001
Directions to the Dalecarlia WTP:
From 495 take the River Road exit towards D.C. Take a right on to Goldsboro (614)
Take a left on to Massachusetts Avenue
At the Westmoreland Circle take the 2nd right on to Dalecarlia Parkway Merge right on to
Loughboro Road
Take a right on to MacArthur Blvd. Take a left at the Dalecarlia WTP gate
Directions to the McMillan WTP:
From 495 take the Georgia Ave. exit (South) towards Washington, D.C.
Turn left on to Harvard St.
Turn left on to 5th St. then keep to the right around the reservoir
Turn right on to 1st St.
Turn right at the McMillan WTP gate
9 Offloading Requirements a Removal of security tags - Upon arrival, security tags are to be removed from hose coupling, manways, and hatches in presence of Washington Aqueduct personnel after seal numbers are verified by
Washington Aqueduct personnel to assure the cargo has not been tampered with.
b Sampling and Testing Prior to Offloading. At the sole discretion of Washington Aqueduct, the
Contractor’s delivery personnel (driver) may occasionally be asked to provide a sample of the chemical from the delivery vehicle before unloading the cargo. Washington Aqueduct will supply the sample container and the driver shall collect the sample from the transportation equipment and turn it over to a
Washington Aqueduct representative. Alternatively, the Contractor shall allow Washington Aqueduct to collect a sample of the Contractor’s product from Washington Aqueduct’s transfer piping at the beginning of the offloading process, and the collected sample shall be considered representative of the
Contractor’s product. Washington Aqueduct reserves the right to subject samples of the chemical to quick tests to ensure that product meets basic conditions of these Specifications. The Contractor shall allow 60 minutes for this testing to be completed.
c Filling appropriate tanks - Washington Aqueduct’s representative will identify the proper storage tank(s) to fill for each delivery. Contractor shall be responsible for transferring chemical from the delivery vehicle into the storage tanks at the delivery site and shall observe the entire filling operation at each delivery site. Contractor shall be responsible for the accidental discharge of the product into the wrong storage tank(s).
d Air padding system - Contractor shall provide an air padding system (an air compressor and pumping system) to be used (at Washington Aqueduct’s sole discretion) as an alternative to Washington
Aqueduct’s transfer system. Contractor shall furnish a Washington Aqueduct- approved, leak-free connection device between the vehicle and Washington Aqueduct’s intake receptacle (a quick disconnect coupling compatible with the WTPs’ couplings). Contractor shall provide all necessary hoses, fittings, air-padding, etc. required to safely and efficiently offload the chemical into designated storage tanks.
e Contractor shall be reimbursed for industry-standard demurrage charges incurred as a result of delays caused by the Washington Aqueduct whenever unloading has not started within (2) two hours after arrival.
f Contractor shall ensure delivery personnel’s compliance with all OSHA requirements, including personal protective equipment for Contractor delivery personnel.
10 Rejection of Deliveries a Failure to provide required documentation upon delivery constitutes grounds for rejection of deliveries.
b Any load tested by Washington Aqueduct that fails to comply with these Specifications shall constitute grounds for rejection of that load.
c Washington Aqueduct reserves the right to reject any delivery that has been contaminated.
11 Condition of Delivery Vehicle a Chemical compatibility - The Phosphoric Acid shall be delivered in tank trucks dedicated only to transporting Phosphoric Acid.
b It is the Contractor’s responsibility to verify the cleanliness of the transporting equipment before loading.
The transporting equipment shall be clean and free of residue that may contaminate the product or impede the unloading process. All appurtenant valves, pumps, and discharge hoses used for the delivery of bulk chemicals shall be supplied by the Contractor and shall be clean and free from contaminating material.
c All delivery vehicles used for the chemical delivery, under this agreement, shall be in good mechanical order and shall be in full compliance with the applicable requirements of the Hazardous Materials
Regulations of the Department of Transportation, Code of Federal Regulations, as currently issued.
d Washington Aqueduct reserves the right to refuse any deliveries made with equipment that is poorly maintained and/or leaking chemical. Any cargo trailer found leaking chemicals is considered an emergency situation requiring immediate attention by the Contractor and shall not be allowed to depart until the Contractor or his designated representative makes appropriate repairs.
12 Spillage a The Contractor shall immediately report any spills caused during the filling operations to the operations control center of the Dalecarlia WTP 202-764-2700 or the McMillan WTP 202-762-0166 (as applicable).
b The Contractor shall take immediate and appropriate actions to clean up any spill. The Contractor shall be responsible for all clean-up of spillage and contaminated matter in accordance with all applicable laws and regulations. The Contractor shall be responsible for any spills or hazardous chemical releases resulting from the failure of its or its subcontractor’s delivery equipment or from failure of attendant delivery personnel in the proper performance of their duties.
c If a spill is not cleaned up, Washington Aqueduct may hire a certified hazardous material handling company to clean up the spill, and the cost of such service will be charged to the Contractor and deducted from the amount due to the Contractor.
13 Invoicing a Unit of measure for payment shall be: Dry tons of Phosphoric Acid delivered FOB destination. The
Contractor shall mail the original delivery invoices to:
USACE Finance Center 5722
Integrity Drive
Millington, TN 38054-5005
Attn: EFT/Disbursing
And a copy to:
5900 MacArthur Blvd., N.W.
Washington, D.C. 2 0016-2514
Attn: Support Management Services, COR (to be named at contract award)
W912DR18Q0028
APPENDIX A
OUTLINE FOR LIMITED-SCOPE CONTRACTS
ACCIDENT PREVENTION PLAN
An Accident Prevention Plan (APP) is a safety and health policy and program document. Contractor’s APP shall address the identified hazards involved and the control measures to be taken. The APP shall interface with the employer’s overall safety and health program, and a copy shall be available on the work site.
The Contractor’s site-specific APP shall include the following.
1. Title, signature, and phone number of the plan preparer.
2. Background Information to include: Contractor; Contract number; project name; brief project description, description of work to be performed, and location.
3. Statement of Safety and Health Policy detailing their commitment to providing a safe and healthful workplace for all employees.
4. Responsibilities and Lines of Authorities – to include a statement of the employer’s ultimate responsibility for the implementation of his SOH program and identification and accountability of personnel responsible for safety.
5. Training – All contract and sub-contract personnel shall have completed required safety training before coming on-site. Provide a list of required training and provide certification of training for employees prior to arriving on-site.
6. Procedures for job site inspections - assignment of responsibilities and frequency.
7. Procedures for reporting and investigating any accidents as soon as possible but not more than 24 hours afterwards to the Contracting Officer/Representative (CO/COR). An accident that results in a fatal injury, permanent partial or permanent total disability shall be immediately reported to the Contracting Officer.
8. Emergency Planning: Identify plan for contract and sub-contract employees working alone to be provided with an effective means of emergency communication. This may be cellular phone, two-way radio or other acceptable means. The selected means of communication must be readily available and must be in working condition.
9. Personal Protective Equipment: Identify personnel protective equipment to be provided.
(a) WORK CLOTHING - Minimum Requirements. Employees shall wear clothing suitable for the weather however minimum requirements for work shall be short-sleeve shirt, long pants (excessively long or baggy pants are prohibited) and leather work shoes. If analysis determines that safety-toed (or other protective) footwear is necessary they shall be worn.
(b) Eye and Face Protection. Eye and face protection shall be worn as determined by an analysis of the operations being performed.
(c) Hearing Protection. Hearing protection must be worn by all those exposed to high noise activities.
(d) Head Protection. Hard hats shall comply with ANSI Z89.1 and shall be worn by all workers when a head hazard exists.
(e) High Visibility Apparel shall comply with ANSI/ISEA 107, Class 2 requirements at a minimum and shall be worn by all workers exposed to vehicular or equipment traffic
(f) Gloves of the proper type shall be worn by persons involved in activities that expose the hands to cuts, abrasions, punctures, burns and chemical irritants.
10. Hazardous Substances: A hazard communication program must be provided and in effect. MSDSs shall be available at the worksite. Employees shall have received training in hazardous substances being used. When the eyes or body of any person may be exposed to corrosives, irritants or toxic chemicals, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within 10 seconds of the worksite.
PRIMARY CONTRACTING OFFICER
"The primary Contracting Officer for this action is La Shura Johnson, however, any Contracting Officer holding the appropriate warrant authority in the Baltimore District can serve as the Contracting Officer for this contract.
Also, please note that any time the primary KO changes, it will be incorporated into the contract via unilateral modification to the contract."
Section SF 1449 - CONTINUATION SHEET
DELIVERY INFORMATION
CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /
CAGE
CLAUSES INCORPORATED BY REFERENCE
52.202-1 Definitions NOV 2013
52.203-5 Covenant Against Contingent Fees MAY 2014
52.203-6 Restrictions On Subcontractor Sales To The Government SEP 2006
52.203-7 Anti-Kickback Procedures MAY 2014
52.203-11 Certification And Disclosure Regarding Payments To
Influence Certain Federal Transactions
SEP 2007
52.204-9 Personal Identity Verification of Contractor Personnel JAN 2011
52.204-16 Commercial and Government Entity Code Reporting JUL 2016
52.204-18 Commercial and Government Entity Code Maintenance JUL 2016
52.208-9 Contractor Use of Mandatory Sources of Supply or Services MAY 2014
52.209-6 Protecting the Government's Interest When Subcontracting
With Contractors Debarred, Suspended, or Proposed for
Debarment
OCT 2015
52.209-10 Prohibition on Contracting With Inverted Domestic
Corporations
NOV 2015
52.212-1 Instructions to Offerors--Commercial Items JAN 2017
52.219-6 Notice Of Total Small Business Set-Aside NOV 2011
52.219-14 Limitations On Subcontracting…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.