DRAWINGS_4.pdf

PDF 7 MB Posted

Attached to
2989 Floating Crane Barge Federal contract opportunity
Solicitation number
W912BU19B0005
Issued by
Department of the Army Corps of Engineers Engineering District Philadeplhia

About this file

drawing package #4

View the file

Other files for this federal contract opportunity

Other files attached to 2989 Floating Crane Barge, newest first.
File Type Posted
DRAWING_2.pdf PDF
DRAWINGS_3.pdf PDF
DRAWINGS_5.pdf PDF
DRAWINGS_1.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Spud Weight Calculations

ITEMS DESCRIPTION MATERIAL

UNIT

WEIGHT

(lb/ft

QUANTITY

(ft /ft/Number)

WEIGHT (lbs)

Side Plates x 2 1" plate ASTM A514 (T1 STEEL) 40.84 289.3 11816.37 ia wire rope IWRC (6 x 19 SEALE)

Back Plate 1" plate ASTM A514 (T1 STEEL) 40.84 135.0 5514.31 12 -

Front plate 1" plate ASTM A514 (T1 STEEL) 40.84 135.0 5514.31 694.4 in

WT baffle plate 1-1/2" plate ASTM A514 (T1 STEEL) 61.26 16.3 999.76 30

NT baffle plate 1" plate ABS Grade A 40.84 21.1 861.11 nt 28

Point web plate 3/4" plate ABS Grade A 30.63 22.1 678.27 1 in

Latch notch side plate 3/4" plate ABS Grade A 30.63 0.7 20.37 1 40.84 lb/ft2

Point Tip 6.5" x 6.5" square bar ABS Grade A 265.20 0.1 33.15 argin 2.00% in

Cap Bracket 3/4" plate ABS Grade A 30.63 9.9 301.71

Cap Plate 3/4" plate ABS Grade A 30.63 14.8 453.94

Latch notch 4" plate ABS Grade A 163.36 0.9 138.86

Latch Hinge 1" plate ABS Grade A 40.84 0.9 35.12

Latch Bolt 2-1/2"×9" with Hex nut & 2 WashersABS Grade A 3.00 1.0 3.00

Half-coupling 3/4"' - 3000 pound threaded ASTM A-105 0.42 8.0 3.36

Pipe Plug threaded 3/4" flush socket ASTM A-105 0.06 8.0 0.48

Sheave side pl 3/4" plate ASTM Grade A 30.63 18.1 554.40

Sheave pin cap ring 12" STD pipe, 1-1/2" long ASTM A-53 49.56 0.1 6.44

Sheave pin cap plate 1/2" plate ABS Grade A 20.42 0.8 17.15

Sheave pin housing 12" STD pipe ABS Grade A 49.56 0.7 34.20

Sheave pin guide bar FB 1/2" x 2" ABS Grade A 3.40 2.1 7.00

Sheave pin inner close plate 3/4" plate ABS Grade A 30.63 0.6 19.60

Sheave pin gasket 1/4" Neporene Commercial 0.25 1.0 0.25

Sheave pin outer close plate 1" plate ABS Grade A 40.84 0.9 35.53

Sheave pin housing insert 1" plate ABS Grade A 40.84 0.1 2.04

Sheave pin close pl screw est. ABS Grade A 0.10 4.0 0.40

Sheave pin body 8" OD x 5" ID x 6-1/4" long ASTM A-108 104.10 0.5 54.13

Sheave pin face 3/4" plate ABS Grade A 30.63 0.4 13.48

Sheave pin grease plate 1/2" plate ABS Grade A 20.42 0.1 2.86

Sheave pin handle 3/4" bar ABS Grade A 1.50 2.2 3.32

Grease recess tube 3" SCH 80 pipe ABS Grade A 10.26 0.2 2.14

Grease recess plate 3/4" plate ABS Grade A 30.63 0.1 2.76

Grease zerk 1/4" NPT male AISI-316 SSTL 0.20 6.0 1.20

Grease tubing 3/8" SCH 80 pipe ABS Grade A 0.40 6.0 2.40

Grease tube fitting 3/8" socket weld ABS Grade A 0.15 6.0 0.90

Sheave 36" OD x 32.25" TD For 1-1/4" Wire Rope 379.00 1.0 379.00

Keeper bolts 1/2" - 13" x 6" long AISI-316 SSTL 0.35 2.0 0.70

Lower Latch Notch side PL 3/4" plate ABS Grade A 30.63 0.2 6.13

Lower Latch Notch PL 4" plate ABS Grade A 163.36 0.1 15.36

SUBTOTAL 27535.49

2% Weld MARGIN 550.71

Calculated weight of a spud (lbs) 28,086.20

MDC PROJECT 2989 DRAWING NO: 850-B554-02

TAI 1208 1

WIRE ROPE

GENERAL PURPOSE

BRIGHT 6X19 CLASS (6x19, 6X21, 6X25, 6X26)

6 x 25 FILLER WIRE

FIBER CORE

6 X 19 SEALE

IWRC

6 X 25 FILLER WIRE

IWRC

6 X 26 IWRC

WARRINGTON SEALE

Approx.

weight per foot in pounds

Breaking strength in

Tons*

Approx.

weight per foot in pounds

Breaking strength in

Tons *

1/4 0.105 3.02 0.116 3.4 5/16 0.164 4.69 0.18 5.27 3/8 0.236 6.71 0.26 7.55 7/16 0.32 9.09 0.35 10.2 1/2 0.42 11.8 0.46 13.3 9/16 0.53 14.09 0.59 16.8 5/8 0.66 18.3 0.72 20.6 3/4 0.95 26.2 1.04 29.4 7/8 1.29 35.4 1.42 39.8

1 1.68 46 1.85 51.7 1 1/8 2.13 57.9 2.34 65 1 1/4 2.63 71 2.89 79.9 1 3/8 3.18 85.4 3.5 96 1 1/2 3.78 101 4.16 114 1 5/8 4.44 118 4.88 132 1 3/4 5.15 136 5.67 153 2 6.72 176 7.39 198 2 1/4 8.51 220 9.36 247 2 1/2 10.5 269 11.6 302 2 3/4 - - 14 361 3 - - 16.6 425 3 1/2 - - 22.6 564

FIBER CORE (EIPS)

Diameter In Inches

IWRC (EIPS)

(IWRC: INDEPENDENT WIRE ROPE CORE OR CENTER)

According to Federal Specifications RR-W-410D, preformed, right regular lay, light to heavy lubrication.

Read important warnings and information on pages 6 - 7 and 12 preceding wire rope section.

NOTE: Lang Lay, left lay, alternate lay, seale available in some sizes.

Heavy lubrication on request.

*Listed for comparison only. Actual operating loads may vary, but should never exceed the recommended design factor or 20% of catalog Breaking Strength. 22

TAI 1208 2

Spud Winch Sizing Calculations

Design load for spud handling system 56,172 lbs

Wire Rope size 1 1/4 in

Breaking strength of 1-1/4" IWRC cable 159,800.00 lbs

A. Spud Sheave Sizing Calculations

(Crosby - McKissick Finished Bore Sheave #36-3)

Angle between the lines at Spud Sheave (Block A) 17.92 deg

Factor Angle @ 20 deg (See Reference 1) 1.97 -

Line pull at Block - A including 5% friction 29,940 lbs

Block-A : Spud sheave size 36 in

Bore size 8.873 in

Shaft size 8 in

Hub width 3.625 in

Tread diameter 32.25 in

Check for Bronze Bushing:

Bearing Pressure (See Reference 1) 2,033.83 psi < 4500 PSI

Bearing velocity (See Reference 1) 27.04 fpm < 1200 FPM

Maximum allowable line speed 113.24 fpm

Required line speed at full line pull 80.00 fpm

Bearing check PASS

Strength efficiency check:

Sheave pitch diameter 33.50 in

Diameter Ratio 26.80 -

Strength efficiency (See Reference 1) 92%

B. Deck Sheave Sizing Calculations

(Crosby - McKissick Bronze Bush Sheave Stock No.

4105471 )

Block-B : Deck sheave size 30 in

Line pull Block-B 29,940 lbs

Angle between the lines at deck sheave (Block B) 107.21 deg

Factor Angle @ 110 deg (See Reference 1) 1.15 -

Total load on the Block B 34,431 lbs

Shaft size 7 in

Hub width 3.5 in

Tread diameter 26.375 in

Check for Bronze Bushing:

Bearing Pressure (See Reference 1) 1,405.33 psi < 4500 PSI

Bearing velocity (See Reference 1) 39.14 fpm < 1200 FPM Maximum allowable line speed 154.45 fpm

Required line speed at full line pull 80.00 fpm

Bearing check PASS

Strength efficiency check:

Sheave pitch diameter 27.63 in

Diameter Ratio 22.10 -

Strength efficiency (See Reference 1) 91%

TAI 1208 3

C. Winch Line Pull Calculations

Design load for winch 56,172 lbs

Angle between the lines at Spud Sheave (Block A) 17.92 deg

Factor Angle @ 20 deg (See Reference 1) 1.97 -

Minimum required line pull (Line tension at Block-A including 3% friction) 29,369 lbs

Line pull increase due to sheave and wire rope inefficiency

31,923.19 lbs

Calculated factor of safety in the wire rope 5.006 -

Spud travel distance 44 ft

No. of line parts to lift the spud 2 -

Spud hoist cable take-up 88 ft

Check for fleeting angle:

Type of drum on winch Grooved

Width of Drum 12.00 in

Minimum distance from lifting cable deck sheave (Block B) to drum centerline 11.5 ft

Maximum fleet angle 2.49 deg

Check: Max. fleet angle < 2.5 deg Pass

Winch model: CME Model 1S50-175*7-16-40 Single Drum

Spud Winch Specifications (See Reference 2)

TAI 1208 4

Copyright © 2017 The Crosby Group LLC All Rights Reserved 495

R ig g in g

In fo495

Rigging InformationRigging Information

MDC PROJECT 2989 DRAWING NO: 850-B554-02

TAI 1208 5

Tech 08 Text Box

REFERENCE 1

TAI 1208 6

TECH14

Typewritten Text

REFERENCE 2

Hull 850 2989 CELRB MCCAULEY CRANE BARGE

1 Net Positive Suction Head (NPSH)

NPSH = HS-HV ft

Suction Head-HS = (Ps/γ)+(Vs /2g) ft Static Head+Velocity Head

HS = 42.02 ft

Liquid Vapor Head-HV = Pv/γ ft Liquid Vapor Head

HV = 0.4151 ft

NPSH = 41.60 ft

1a Suction Head-HS

Suction Lift-HS = (Ps/γ)+(Vs /2g) ft

Ps = 2116.80 lb/ft 2 Atmospheric pressure (14.7 psi) γ = 52.04 lb/ft

Specific Weight of Diesel at 59 o F

Vs = 2.83 m/s

= 9.28 ft/s

Acceleration Due to Gravity-g = 32.20 ft/s

Suction Head-HS = 42.02 ft

1b Liquid Vapor Pressure-HV

Liquid Vapor Pressure-HV = Pv/γ ft

PV = 0.15 psi (See Ref 2) Vapor Pressure of Diesel at 68 o F

= 21.6 lb/ft γ = 52.04 lb/ft

Specific Weight of Diesel at 59 o F

Liquid Vapor Pressure-HV = 0.4151 ft

2 Net Positive Suction Head Available (NPSHA)

NPSHA = NPSH-HF-HZ ft

NPSH = 41.60 ft

HF = 0.6524 ft Friction Losses in Suction Pipe

HZ = 7 ft Suction Lift

NPSHA = 33.95 ft

NPSHR = 15.00 ft (See Ref 1)

Approved By

TAI

Project Title:

TAI-1208 FLOATING CRANE

Proj. no:

TAI 1208

Subject:

FUEL PUMP NPSH CALCULATIONS

Ref: 1. Portable Gear Pump, 25 GPM - Goldstream Pumps -http://www.goldstreampumps.com/portable-gear-pump-25gpm.html

2. http://www.online.petro-canada.ca/datasheets/en_CA/w104.pdf

Prepared By MB

Checked By NK

Date:

10-24-18

850-B630-02 2 of 5

1 Fuel Oil System Pressure Drop Calculations:

Pump Outlet Flow = 25 gpm

= 5.68 m /hr

Pipe Sizes Used = 1"

Outer Dia. (in) = 1.315

Thickness (in) = 0.133

Inside Dia. (in) = 1.049

Inside Dia. (m) = 0.0266

1a Pressure Drop in Pipes

Hp = f*(L/D)*(V /2g) m Pressure drop in pipes

Hp = Head loss (m) f = Friction Factor

L = Length of Pipe (m)

D = Diameter of Pipe (m)

V = Velocity of Fluid (m/s) g = Acceleration Due to Gravity (m/s g DIA. (D) Hp

(m/s ) (m) (m)

0.023 9.81 0.0266 0.05

0.18 9.81 0.0266

0.023 9.81 0.0266 0.05

2.3 9.81 0.0266

0.023 9.81 0.0266 0.05

7.5 9.81 0.0266

0.023 9.81 0.0266 0.05

0.37 9.81 0.0266

0.023 9.81 0.0266 0.05

0.376 9.81 0.0266

0.023 9.81 0.0266 0.48

0.37 9.81 0.0266

0.023 9.81 0.0266 0.39

0.376 9.81 0.0266

0.023 9.81 0.0266 2.15

0.37 9.81 0.0266

0.023 9.81 0.0266 0.39

0.376 9.81 0.0266

0.023 9.81 0.0266 1.87

2.83 5.68

2.83

2.83

2.83

2.83

5.68

5.68

5.68

5.68

2.83

2.83

2.83

2.83

5.68

T-Joint (TF) 5.68

1.37

1.10

Bend 90 Deg 2.83 5.68

0.15

T-Joint (TF)

5.68

5.68

0.15

Flow Meter

Project Title:

TAI-1208 FLOATING CRANE

Subject:

FUEL OIL SYSTEM PRESSURE DROP CALCULATIONS

6.10

Bend 90 Deg

1.10

T-Joint (TF)

5.30

5.68

Bend 90 Deg

5.68

5.68

5.68

5.68

2.83

2.83

2.83

2.83

2.83 5.68

2.83 5.68

2.83

Proj. no:

TAI 1208

Date:

10-25-18

TAI

0.15

Check Valve 2.83 5.68

0.15 2.83 5.68

FLOW RATE (Q)

(m /hr)

VELOCITY (V)

(m/s)

SEGMENT

LENGTH (L)

(m)

0.15

FRICT.

COEFF

(f)

Gate Valve

PUMP TO

ENGINE BUILT

FO TANKS

850-B630-01 3 of 5

Project Title:

TAI-1208 FLOATING CRANE

Subject:

FUEL OIL SYSTEM PRESSURE DROP CALCULATIONS

Proj. no:

TAI 1208

Date:

10-25-18

TAI

0.37 9.81 0.0266

0.023 9.81 0.0266 1.58

0.2 9.81 0.0266

0.023 9.81 0.0266 0.05

1 9.81 0.0266

0.023 9.81 0.0266 0.08

0.37 9.81 0.0266

0.023 9.81 0.0266 0.77

0.2 9.81 0.0266

0.023 9.81 0.0266 0.05

1 9.81 0.0266

0.023 9.81 0.0266 0.08

0.37 9.81 0.0266

0.023 9.81 0.0266 0.77

0.2 9.81 0.0266

0.023 9.81 0.0266 0.05

1 9.81 0.0266

0.023 9.81 0.0266 0.08

0.37 9.81 0.0266

0.023 9.81 0.0266 0.77

0.2 9.81 0.0266

0.023 9.81 0.0266 0.05

1 9.81 0.0266

9.90

PUMP TO

ENGINE BUILT

FO TANKS

5.68

Gate Valve

0.15

Flex Hose

5.68

5.68

5.68

5.68

5.68

Bend 90 Deg

2.20

5.68

5.68

5.68

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

5.68

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

5.68

5.68

5.68

5.68

5.68

5.68

0.15

Flex Hose

0.23

5.68

5.68

2.83

Gate Valve

0.15

Flex Hose

0.23

Bend 90 Deg

2.20

Gate Valve

0.15

5.68

5.68

5.68

5.68

5.68

2.83

2.83

Total Head Loss in Pipes

Bend 90 Deg

4.50

Flex Hose

0.23

Bend 90 Deg

2.20

Gate Valve

850-B630-01 4 of 5

Project Title:

TAI-1208 FLOATING CRANE

Subject:

FUEL OIL SYSTEM PRESSURE DROP CALCULATIONS

Proj. no:

TAI 1208

Date:

10-25-18

TAI

1b Pressure Drop in Fittings

Hf = kv /2g k = Friction Factor g Hf

(m/s

2) (m)

9.81 0.07

9.81 0.94

9.81 3.06

9.81 0.15

9.81 0.15

9.81 0.15

9.81 0.15

9.81 0.15

9.81 0.15

9.81 0.15

9.81 0.08

9.81 0.41

9.81 0.15

9.81 0.08

9.81 0.41

9.81 0.15

9.81 0.08

9.81 0.41

9.81 0.15

9.81 0.08

9.81 0.41

7.54

1c Geostatic Height (Z)

Geostatic Height - Z = 6.7 m

Total Pressure Drop in Piping System = 24.14 m H2O

= 79.21 ft H2O

Selected Pump Discharge Head = 90 ft

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

2.83

0.37

0.2

0.37

0.2

0.37

0.2

Flex Hose

Bend 90 Deg

Gate Valve

0.376

0.37

0.376

0.37

0.2

Gate Valve

Flex Hose

Bend 90 Deg

Gate Valve

T-Joint (TF)

Bend 90 Deg

T-Joint (TF)

Bend 90 Deg

T-Joint (TF)

Bend 90 Deg

RESISTANCE COEFF

(K)

Gate Valve

Ref: 1. Portable Gear Pump, 25 GPM - Goldstream Pumps -http://www.goldstreampumps.com/portable-gear-pump-25gpm.html Checked By NK

MBPrepared By

Approved By

Total Head Loss in Fittings

1 2.83

PUMP TO

ENGINE BUILT

FO TANKS

0.376

0.37

2.83

2.83

2.83

2.83

SEGMENT DESCRIPTION

VELOCITY

(m/s)

Gate Valve 0.18

Check Valve 2.832.3

7.5

0.37

Flex Hose

Flex Hose

Flow Meter

Bend 90 Deg

Bend 90 Deg

2.83

850-B630-01 5 of 5

10/30/2018 Portable Gear Pump, 25gpm http://www.goldstreampumps.com/portable-gear-pump-25gpm.html 1/2

Home Portable Gear Pump, 25gpm

- 1 + ADD TO CART

Availability: In stock

For Medium to Light Oils, Diesel, Vegetable Oil

Product code : GSM25

0 Review(s) | Add Your Review

Share

Product Description Tags Reviews Add Review

Powerful, Fast and PortablePowerful, Fast and Portable This pump package is the ideal pump for portable oil transfer. Close Coupled to a power 3/4hp 3450rpm Baldor Motor will easily tranfer lighter oils such as vegetable oil or diesel fuel (<50cSt)

Additional Specs:

*Dimensions: 17" long x 11" wide x 7" tall (43 cm x 28 cm x 18 cm)

*Weight: 45lbs

*Self Priming

*Suction Height: 15ft

*Push Lift Height: 90ft

*Reversible - Rewire or add a switch to allow dual directional flow!

*Viton Seals

*B100 compatible

*Temperature Rating of 400*F

*Duty Cycle: Continuous

*Priming: Self priming

*25gpm(95 liters/min): 1" threaded ports, 1.25" hose barbs

*Not for Motor Oil. Find a Motor Oil Pump here.

*Pump needs oil to lubricate the gears. Will not work with water.

Motor Specs

*Commercial Duty Power Switch With 2.5 Foot Power Cord

*Thermal Overload Protection

*Output: 3/4 HP

*Speed: 3450 RPM

*Volts: 120 or 220 (comes prewired for 120)

*Amps: 8.7 @ 120 volts, 4.4 @ 220 volts

Portable Gear Pump, 25gpmPortable Gear Pump, 25gpm http://www.goldstreampumps.com/ http://www.wvodesigns.com/shop/wvo-pumps/portable-12gpm-goldstream-hd-oil-transfer-pump.html http://www.goldstreampumps.com/catalog/product_compare/add/product/1/uenc/aHR0cDovL3d3dy5nb2xkc3RyZWFtcHVtcHMuY29tL3BvcnRhYmxlLWdlYXItcHVtcC0yNWdwbS5odG1s/form_key/k3fn3TQYOFn4o0UZ/

TECH07

APPENDIX-A

10/30/2018 Portable Gear Pump, 25gpm http://www.goldstreampumps.com/portable-gear-pump-25gpm.html 2/2

*Hertz: 60

*Shaft Size: 14 mm

*Shaft Woodruff Key: 5 mm width x 5 mm deep x 16 mm length

*Motor Base Mount: 4.5" Long x 6.56" Wide

Pumphead Specs

*Bolt Pattern: 7 mm holes on a 85 mm circle

*Shaft Size: 14 mm keyed shaft

*Shaft Woodruff Key: 5 mm width x 5 mm deep x 12 mm length

*Viton Seals

*Self Priming

*Cast Iron

*1" NPT Ports

*Stainless Steel 1.25" Hose Barbs Included (fits 1.25" hose kit)

*No Pressure Regulator

Coupling Specs

*Pump Coupling: 14 mm

*Motor Coupling: 14 mm

*Size: C

*Overall Length: 1 63/64"

*Hub Diameter: 1 23/64"

*Bore Depth: 1 3/4"

*Screw Size: 1/4"-20

*Spider Element: Buna-N 27/64" n.koyyapu@taiengineers.com

From: Mary Munoz <mary@wvodesigns.com> Sent: Friday, October 26, 2018 7:35 AM To: n.koyyapu@taiengineers.com Cc: Leon Griffin Subject: Re: TAI 1208 - 25gpm gear pump

Hi Naresh, About that, I think I've answered that yesterday that we don't have it.

Thanks Mary

On Fri, Oct 26, 2018 at 8:34 PM <n.koyyapu@taiengineers.com> wrote:

Hello Leon, I am looking for pump curves for portable gear pump 25 GPM. Would you please provide.

Thanks, Naresh

From: Mary Munoz <mary@wvodesigns.com> Sent: Friday, October 26, 2018 7:17 AM To: n.koyyapu@taiengineers.com; Leon Griffin <leon@wvodesigns.com> Subject: Re: TAI 1208 ‐ 25gpm gear pump

Hi Naresh, Copied on the email is my boss, Leon. You can send him questions and information you want to know about portable 25gpm.

Thanks

Mary

TECH07

Rectangle

SAFETY DATA SHEET

DIESEL FUEL

000003000395

Version 4.2 Revision Date 2018/09/12 Print Date 2018/09/12

Internet: www.petro-canada.ca/msds Page: 1 / 12 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence.

SECTION 1. IDENTIFICATION

Product name : DIESEL FUEL

Synonyms : Seasonal Diesel, #1 Diesel, #2 Heating Oil, #1 Heating Oil, D50, Arctic Diesel, Farm Diesel, Marine Diesel, Low Sulphur Diesel, LSD, Ultra Low Sulphur Diesel, ULSD, Mining Diesel, Naval Distillate, Dyed Diesel, Marked Diesel, Coloured Die-sel, Furnace special, Biodiesel blend, B1, B2, B5, Diesel Low Cloud (LC), Marine Gas Oil, Marine Gas Oil Dyed.

Product code : 102907, 102762, 102763, 102755, 102302, 102744, 101801, 100678, 100677, 101802, 100107, 100668, 100658, 100911, 100663, 100652, 100460, 100065, 101796, 101793, 101795, 101792, 101794, 101791, 100768, 100643, 100642, 100103, 101798, 101800, 101797, 101788, 101789, 101787, 102531, 100734, 100733, 100640, 100997, 100995, 100732, 100731, 100994

Manufacturer or supplier's details Petro-Canada P.O. Box 2844, 150 - 6th Avenue South-West

Calgary Alberta T2P 3E3 Canada

Emergency telephone num-ber

Suncor Energy: +1 403-296-3000;

Canutec Transportation: 1-888-226-8832 (toll-free) or 613- 996-6666;

Poison Control Centre: Consult local telephone directory for emergency number(s).

Recommended use of the chemical and restrictions on use

Recommended use

: Diesel fuels are distillate fuels suitable for use in high and medium speed internal combustion engines of the compres-sion ignition type. Mining diesels, marine diesels, MDO and naval distillates may have a higher flash point requirement.

Prepared by : Product Safety: +1 905-804-4752

SECTION 2. HAZARDS IDENTIFICATION

Emergency Overview

Appearance

Bright oily liquid.

Colour

Clear to yellow (This product may be dyed red for taxation pur-poses)

Odour

Mild petroleum oil like.

GHS Classification

APPENDIX-B

Internet: www.petro-canada.ca/msds Page: 2 / 12

Flammable liquids

: Category 3

Acute toxicity (Inhalation)

: Category 4

Skin irritation

: Category 2

Carcinogenicity

: Category 2

Specific target organ toxicity

- single exposure

: Category 3 (Central nervous system)

Specific target organ toxicity

- repeated exposure

: Category 2 (Liver, thymus, Bone)

Aspiration hazard

: Category 1

GHS label elements

Hazard pictograms

Signal word

: Danger

Hazard statements

: Flammable liquid and vapour.

May be fatal if swallowed and enters airways.

Causes skin irritation.

Harmful if inhaled.

May cause drowsiness or dizziness.

Suspected of causing cancer.

May cause damage to organs (Liver, thymus, Bone) through prolonged or repeated exposure.

Precautionary statements

: Prevention:

Obtain special instructions before use.

Do not handle until all safety precautions have been read and understood.

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Keep container tightly closed.

Ground and bond container and receiving equipment.

Use explosion-proof electrical/ ventilating/ lighting equipment.

Use non-sparking tools.

Take action to prevent static discharges.

Do not breathe dust/ fume/ gas/ mist/ vapours/ spray.

Wash skin thoroughly after handling.

Use only outdoors or in a well-ventilated area.

Wear protective gloves/ protective clothing/ eye protection/ face protection.

Response:

IF SWALLOWED: Immediately call a POISON CENTER/doctor.

IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.

IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell.

Internet: www.petro-canada.ca/msds Page: 3 / 12

IF exposed or concerned: Get medical advice/ attention.

Do NOT induce vomiting.

If skin irritation occurs: Get medical advice/ attention.

Take off contaminated clothing and wash it before reuse.

In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.

Storage:

Store in a well-ventilated place. Keep container tightly closed.

Store in a well-ventilated place. Keep cool.

Store locked up.

Disposal:

Dispose of contents/ container to an approved waste disposal plant.

Potential Health Effects

Primary Routes of Entry

: Eye contact Ingestion Inhalation Skin contact Skin Absorption

Target Organs

: Skin Eyes Respiratory Tract

Inhalation

: May cause respiratory tract irritation.

Inhalation may cause central nervous system effects.

Symptoms and signs include headache, dizziness, fatigue, muscular weakness, drowsiness and in extreme cases, loss of consciousness.

Skin

: Causes skin irritation.

Eyes

: Causes eye irritation.

Ingestion

: Ingestion may cause gastrointestinal irritation, nausea, vomit-ing and diarrhoea.

Aspiration hazard if swallowed - can enter lungs and cause damage.

Aggravated Medical Condi-tion

: None known.

Other hazards

None known.

IARC

No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.

ACGIH

Confirmed animal carcinogen with unknown relevance to hu-mans

Fuel Oil No. 1 8008-20-6

Internet: www.petro-canada.ca/msds Page: 4 / 12

SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS

Substance / Mixture

: Mixture

Hazardous components

Chemical name

CAS-No. Concentration fuels, diesel 68334-30-5 70 - 100 % kerosine (petroleum) 8008-20-6 kerosine (petroleum), hydrodesulfurized 64742-81-0 Alkanes, C10-20-branched and linear 928771-01-1 0 - 25 % Soybean oil, Methyl ester 67784-80-9 0 - 5 % Rape oil, Methyl ester 73891-99-3 Fatty acids, tallow, Methyl esters 61788-61-2

SECTION 4. FIRST AID MEASURES

If inhaled

: Move to fresh air.

Artificial respiration and/or oxygen may be necessary.

Seek medical advice.

In case of skin contact

: In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes.

Wash skin thoroughly with soap and water or use recognized skin cleanser.

Wash clothing before reuse.

In case of eye contact

: Remove contact lenses.

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

Obtain medical attention.

If swallowed

: Rinse mouth with water.

DO NOT induce vomiting unless directed to do so by a physi-cian or poison control center.

Never give anything by mouth to an unconscious person.

Most important symptoms and effects, both acute and delayed

: None known.

Protection of first-aiders

: First Aid responders should pay attention to self-protection and use the recommended protective clothing It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation.

Internet: www.petro-canada.ca/msds Page: 5 / 12

SECTION 5. FIREFIGHTING MEASURES

Suitable extinguishing media

: Dry chemical Carbon dioxide (CO2) Water fog.

Foam

Unsuitable extinguishing media

: Do NOT use water jet.

Specific hazards during fire-fighting

: Cool closed containers exposed to fire with water spray.

Hazardous combustion prod-ucts

: Carbon oxides (CO, CO2), nitrogen oxides (NOx), sulphur oxides (SOx), sulphur compounds (H2S), smoke and irritating vapours as products of incomplete combustion.

Further information : Prevent fire extinguishing water from contaminating surface water or the ground water system.

Special protective equipment for firefighters

: Wear self-contained breathing apparatus for firefighting if nec-essary.

SECTION 6. ACCIDENTAL RELEASE MEASURES

Personal precautions, protec-tive equipment and emer-gency procedures

: Use personal protective equipment.

Ensure adequate ventilation.

Evacuate personnel to safe areas.

Material can create slippery conditions.

Environmental precautions

: If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and materials for containment and cleaning up

: Prevent further leakage or spillage if safe to do so.

Remove all sources of ignition.

Soak up with inert absorbent material.

Non-sparking tools should be used.

Ensure adequate ventilation.

Contact the proper local authorities.

SECTION 7. HANDLING AND STORAGE

Advice on safe handling

: For personal protection see section 8.

Smoking, eating and drinking should be prohibited in the ap-plication area.

Use only with adequate ventilation.

In case of insufficient ventilation, wear suitable respiratory equipment.

Avoid spark promoters. Ground/bond container and equip-ment. These alone may be insufficient to remove static elec-tricity.

Avoid contact with skin, eyes and clothing.

Do not ingest.

Internet: www.petro-canada.ca/msds Page: 6 / 12

Keep away from heat and sources of ignition.

Keep container closed when not in use.

Conditions for safe storage

: Store in original container.

Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Keep in a dry, cool and well-ventilated place.

Keep in properly labelled containers.

To maintain product quality, do not store in heat or direct sun-light.

SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Components with workplace control parameters Components CAS-No. Value type

(Form of exposure)

Control parame-ters / Permissible concentration

Basis kerosine (petroleum), hy-drodesulfurized

64742-81-0 TWA 200 mg/m3 (As total hydro-carbon vapour)

ACGIH

TWA 200 mg/m3 (As total hydro-carbon vapour)

ACGIH

kerosine (petroleum) 8008-20-6 TWA 200 mg/m3 (total hydrocarbon vapor)

CA BC OEL

TWA 200 mg/m3 (total hydrocarbon vapor)

CA AB OEL

TWA 200 mg/m3 (total hydrocarbon vapor)

ACGIH

Engineering measures : Use only in well-ventilated areas.

Ensure that eyewash station and safety shower are proximal to the work-station location.

Personal protective equipment

Respiratory protection

: Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines.

Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Filter type

: organic vapour cartridge or canister may be permissible un-der certain circumstances where airborne concentrations are expected to exceed exposure limits. Protection provided by air-purifying respirators is limited. Use a positive-pressure, air-supplied respirator if there is any potential for uncontrolled release, exposure levels are unknown, or any other circum-stances where air-purifying respirators may not provide ade-quate protection.

Internet: www.petro-canada.ca/msds Page: 7 / 12

Hand protection Material : neoprene, nitrile, polyvinyl alcohol (PVA), Viton(R). Consult your PPE provider for breakthrough times and the specific glove that is best for you based on your use patterns. It should be realized that eventually any material regardless of their imperviousness, will get permeated by chemicals.

Therefore, protective gloves should be regularly checked for wear and tear. At the first signs of hardening and cracks, they should be changed.

Remarks

: Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is nec-essary.

Eye protection

: Wear face-shield and protective suit for abnormal processing problems.

Skin and body protection

: Choose body protection in relation to its type, to the concen-tration and amount of dangerous substances, and to the spe-cific work-place.

Protective measures

: Wash contaminated clothing before re-use.

Hygiene measures

: Remove and wash contaminated clothing and gloves, includ-ing the inside, before re-use.

Wash face, hands and any exposed skin thoroughly after handling.

SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES

Appearance : Bright oily liquid.

Colour : Clear to yellow (This product may be dyed red for taxation purposes)

Odour : Mild petroleum oil like.

Odour Threshold : No data available pH : No data available

Pour point : No data available

Boiling point/boiling range : 150 - 371 °C (302 - 700 °F)

Flash point : > 40 °C (104 °F) Method: closed cup

Auto-Ignition Temperature : 225 °C (437 °F)

Evaporation rate : No data available

Flammability : Flammable in presence of open flames, sparks and heat. Va-

Internet: www.petro-canada.ca/msds Page: 8 / 12 pours are heavier than air and may travel considerable dis-tance to sources of ignition and flash back. This product can accumulate static charge and ignite.

Upper explosion limit : 6 %(V)

Lower explosion limit : 0.7 %(V)

Vapour pressure : 7.5 mmHg (20 °C / 68 °F)

Relative vapour density : 4.5

Relative density : 0.8 - 0.88

Solubility(ies)

Water solubility : insoluble

Partition coefficient: n-octanol/water

: No data available

Viscosity

Viscosity, kinematic : 1.3 - 4.1 cSt (40 °C / 104 °F)

Explosive properties : Do not pressurise, cut, weld, braze, solder, drill, grind or ex-pose containers to heat or sources of ignition. Runoff to sewer may create fire or explosion hazard.

SECTION 10. STABILITY AND REACTIVITY

Possibility of hazardous reac-tions

: Hazardous polymerisation does not occur.

Stable under normal conditions.

Conditions to avoid

: Extremes of temperature and direct sunlight.

Incompatible materials

: Reactive with oxidising agents and acids.

Hazardous decomposition products

: May release COx, NOx, SOx, H2S, smoke and irritating va-pours when heated to decomposition.

SECTION 11. TOXICOLOGICAL INFORMATION

Information on likely routes of exposure Eye contact Ingestion Inhalation Skin contact Skin Absorption

Acute toxicity

Tech 08

Internet: www.petro-canada.ca/msds Page: 9 / 12

Product:

Acute oral toxicity

: Remarks: No data available

Acute inhalation toxicity

Acute dermal toxicity

: Assessment: The substance or mixture has no acute dermal toxicity Remarks: No data available

Components:

fuels, diesel:

: LD50 (Rat): 7,500 mg/kg, : LD50 (Mouse): 24,500 mg/kg, kerosine (petroleum):

: LD50 (Rat): > 5,000 mg/kg, : LC50 (Rat): > 5 mg/l Exposure time: 4 h Test atmosphere: dust/mist

: LD50 (Rabbit): > 2,000 mg/kg, kerosine (petroleum), hydrodesulfurized:

: LD50 (Rat): > 5,000 mg/kg, : LC50 (Rat): > 5.2 mg/l Exposure time: 4 hrs Test atmosphere: dust/mist

: LD50 (Rabbit): > 2,000 mg/kg, Skin corrosion/irritation

Serious eye damage/eye irritation

Remarks: No data available

Respiratory or skin sensitisation

No data available

Germ cell mutagenicity

No data available

Carcinogenicity

Internet: www.petro-canada.ca/msds Page: 10 / 12

Reproductive toxicity

No data available

STOT - single exposure

No data available

STOT - repeated exposure

No data available

SECTION 12. ECOLOGICAL INFORMATION

Ecotoxicity

Toxicity to fish

Toxicity to daphnia and other aquatic invertebrates

Toxicity to algae

Toxicity to bacteria

Persistence and degradability

Biodegradability

Bioaccumulative potential

Mobility in soil

No data available

Other adverse effects

No data available

SECTION 13. DISPOSAL CONSIDERATIONS

Disposal methods Waste from residues : The product should not be allowed to enter drains, water courses or the soil.

Offer surplus and non-recyclable solutions to a licensed dis-posal company.

Waste must be classified and labelled prior to recycling or disposal.

Send to a licensed waste management company.

Internet: www.petro-canada.ca/msds Page: 11 / 12

Dispose of as hazardous waste in compliance with local and national regulations.

Dispose of product residue in accordance with the instructions of the person responsible for waste disposal.

Contaminated packaging : Do not re-use empty containers.

SECTION 14. TRANSPORT INFORMATION

International Regulations

IATA-DGR

UN/ID No. : UN 1202 Proper shipping name : Diesel fuel Class : 3 Packing group : III Labels : Class 3 - Flammable Liquid Packing instruction (cargo aircraft)

: 366

IMDG-Code UN number : UN 1202 Proper shipping name : DIESEL FUEL

Class : 3 Packing group : III Labels : 3 EmS Code : F-E, S-E Marine pollutant : no

Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

National Regulations

TDG

UN number : UN 1202 Proper shipping name : DIESEL FUEL

Class : 3 Packing group : III Labels : 3 ERG Code : 128 Marine pollutant : no

SECTION 15. REGULATORY INFORMATION

This product has been classified according to the hazard criteria of the Hazardous Products Reg-ulations (HPR) and the SDS contains all of the information required by the HPR.

The components of this product are reported in the following inventories:

DSL On the inventory, or in compliance with the inventory

Internet: www.petro-canada.ca/msds Page: 12 / 12

TSCA All chemical substances in this product are either listed on the TSCA Inventory or are in compliance with a TSCA Inventory exemption.

EINECS On the inventory, or in compliance with the inventory

SECTION 16. OTHER INFORMATION

For Copy of SDS : Internet: www.petro-canada.ca/msds

Canada-wide: telephone: 1-800-668-0220; fax: 1-800-837- For Product Safety Information: 1 905-804-4752

Prepared by : Product Safety: +1 905-804-4752

Revision Date

: 2018/09/12

The information provided in this Safety Data Sheet is correct to the best of our knowledge, infor-mation and belief at the date of its publication. The information given is designed only as a guid-ance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text.

TAI 1208 USACE

LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW

1 Diesel Tank Heater 1 480V 18.00 0.00 0.00 0.90 16.20 0.00 0.00 0.90 16.20 0.00 0.00 0.90 16.20 0.00 0.00 0.90 16.20 2 Air Conditioner 1 208V 3.00 0.70 2.10 0.00 0.00 0.70 2.10 0.00 0.00 0.70 2.10 0.00 0.00 0.70 2.10 0.00 0.00 3 Cab Heaters 1 208V 2.25 0.00 0.00 0.90 2.03 0.00 0.00 0.90 2.03 0.00 0.00 0.90 2.03 0.00 0.00 0.90 2.03 4 Cab Defrosters 1 208V 2.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 1.13 0.50 1.13 0.00 0.00 0.00 0.00 5 Camera System 1 120V 0.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 0.14 0.50 0.14 0.00 0.00 0.00 0.00 6 Cab Light 1 120V 0.03 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02 7 Gantry Lights 1 120V 0.31 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19 8 Eng. H. Lights 1 120V 0.18 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11 9 Cab Enclsure Light 1 120V 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 10 Gps System 1 120V 0.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.90 0.19 0.90 0.19 0.00 0.00 0.00 0.00 11 24VDC Power Supply 1 208V 0.96 0.80 0.77 0.80 0.77 0.80 0.77 0.80 0.77 0.90 0.86 0.90 0.86 0.80 0.77 0.80 0.77 12 12VDC Power Supply 1 120V 0.29 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23 13 Boom Lights 1 208V 0.67 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40 14 Cab GFCI Receptacle 2 120V 1.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 1.92 0.50 1.92 0.00 0.00 0.00 0.00 15 Hydraulic Oil Heaters 1 208V 4.00 0.00 0.00 0.50 2.00 0.00 0.00 0.50 2.00 0.00 0.00 0.50 2.00 0.00 0.00 0.50 2.00 16 Water Jacket Heater 1 208V 3.00 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 17 Engine House Heater 2 208V 3.10 0.00 0.00 0.50 3.10 0.00 0.00 0.50 3.10 0.00 0.00 0.50 3.10 0.00 0.00 0.50 3.10 18 Engine Oil Heater 1 208V 0.30 0.00 0.00 0.25 0.08 0.00 0.00 0.25 0.08 0.00 0.00 0.25 0.08 0.00 0.00 0.25 0.08 19 Battery Charger 1 208V 1.70 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68 20 Electrical Cabinet Light 1 120V 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 21 Engine House GFCI Receptacle 1 120V 1.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.90 1.73 0.90 1.73 0.00 0.00 0.00 0.00 22 Slip Ring Heater 1 120V 0.06 0.00 0.00 0.90 0.05 0.00 0.00 0.90 0.05 0.00 0.00 0.90 0.05 0.00 0.00 0.90 0.05 23 GFD Test 1 120V 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19

Total Crane Slip Ring Load 4.70 27.55 4.70 27.55 9.90 32.75 4.70 27.55

24 Welder 1 240VAC, 3Phase 18.00 0.20 3.60 0.20 3.60 0.10 1.80 0.10 1.80 0.20 3.60 0.20 3.60 0.10 1.80 0.10 1.80 25 Plasma Cutter (Center) 1 240VAC, 3Phase 3.00 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 26 Welding Invertor 1 240VAC, 3Phase 2.25 0.10 0.23 0.10 0.23 0.00 0.00 0.00 0.00 0.10 0.23 0.10 0.23 0.00 0.00 0.00 0.00 27 240VAC Deck Receptacle # 1 ‐ 75Amps 1 240VAC, 3Phase 13.20 0.20 2.64 0.20 2.64 0.10 1.32 0.10 1.32 0.20 2.64 0.20 2.64 0.10 1.32 0.10 1.32 28 240VAC Deck Receptacle # 2 ‐ 75Amps 1 240VAC, 3Phase 13.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 29 240VAC Deck Receptacle # 3 ‐ 75 Amps 1 240VAC, 3Phase 13.20 0.20 2.64 0.20 2.64 0.00 0.00 0.00 0.00 0.20 2.64 0.20 2.64 0.00 0.00 0.00 0.00 30 240VAC Deck Receptacle # 4 ‐ 75 Amps 1 240VAC, 3Phase 13.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 31 240VAC Deck Receptacle # 5 ‐ 25 Amps 1 240VAC, 3Phase 4.40 0.20 0.88 0.20 0.88 0.10 0.44 0.10 0.44 0.20 0.88 0.20 0.88 0.13 0.55 0.13 0.55 32 240VAC Deck Receptacle # 6 ‐ 25 Amps 1 240VAC, 3Phase 4.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 33 240VAC Deck Receptacle # 7 ‐ 25 Amps 1 240VAC, 3Phase 4.40 0.20 0.88 0.20 0.88 0.00 0.00 0.00 0.00 0.20 0.88 0.20 0.88 0.00 0.00 0.00 0.00 34 240VAC Deck Receptacle # 8 ‐ 25 Amps 1 240VAC, 3Phase 4.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Total Load on 480 to 240 VAC Tx - This load is reflected as a load factor on the 480 to 240VAC Tx 11.17 11.17 3.86 3.86 11.17 11.17 3.97 3.97

35 Fuel Transfer Pump (2hp/1.5 KW) 1 120V, 1 Phase 1.50 0.10 0.15 0.10 0.15 0.10 0.15 0.10 0.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 36 Auxiliary Bilge Pump, Portable (2 HP/1.5kw) 1 120V, 1 Phase 1.50 0.10 0.15 0.10 0.15 0.10 0.15 0.10 0.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 37 Ship Receptacle circuit #1 5 120V, 1 Phase 1.80 0.10 0.90 0.10 0.90 0.30 2.70 0.30 2.70 0.10 0.90 0.10 0.90 0.30 2.70 0.30 2.70 38 Ship Receptacle circuit #2 5 120V, 1 Phase 1.80 0.10 0.90 0.10 0.90 0.30 2.70 0.30 2.70 0.10 0.90 0.10 0.90 0.30 2.70 0.30 2.70 39 Deck Lights (LED) 20 120V, 1 Phase 0.25 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 40 Flood Lights (LED) 10 120V, 1 Phase 0.50 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 0.60 3.00 41 Module Bucket 1 120V, 1 Phase 2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.75 1.50 0.75 1.50 0.00 0.00 0.00 0.00 42 SwitchBoard Heater 1 120V, 1 Phase 0.96 0.00 0.00 0.90 0.86 0.00 0.00 0.90 0.86 0.00 0.00 0.90 0.86 0.00 0.00 0.90 0.86 43 Spud Winch Heater 4 120V, 1 Phase 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.25 1.00 44 Deck Winch Heater 2 120V, 1 Phase 0.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 45 Genset Engine Block Heater 2 120V, 1 Phase 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.25 0.50 0.00 0.00 0.25 0.50 0.00 0.00 0.25 0.50 46 Standalone Genset Engine Block Heater 1 120V, 1 Phase 1.00 0.00 0.00 0.25 0.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 47 DC Battery Charger 1 120V, 1 Phase 1.44 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58 48 Genset Battery Charger 1 120V, 1 Phase 1.08 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43

TOTAL 208/240/120VAC LOAD - This load is reflected as a load factor on the 480 to 208/120VAC Tx 9.1 10.2 12.7 16.1 10.3 11.7 12.4 14.8

Loads on 480 to 240VAC Transformer

208/240/120V LOADS

MDC 2989 Floating Crane - Electrical Plant Load Analysis- Rev P2

OPERATING CONDITIONS

KW

SUMMER WINTER

OPERATING CONDITION - 01 OPERATING CONDITION - 02

SUMMER WINTER

OPERATING CONDITION - 03

SUMMER WINTER

OPERATING CONDITION - 04

SUMMER WINTERITEM NO. VOLTAGE LOAD DESCRIPTION QTY

CONNECTED

LOAD

PER ITEM

Crane Slip Ring Loads

TAI 1208 USACE

LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW LOAD

FACTOR KW

MDC 2989 Floating Crane - Electrical Plant Load Analysis- Rev P2

OPERATING CONDITIONS

KW

SUMMER WINTER

OPERATING CONDITION - 01 OPERATING CONDITION - 02

SUMMER WINTER

OPERATING CONDITION - 03

SUMMER WINTER

OPERATING CONDITION - 04

SUMMER WINTERITEM NO. VOLTAGE LOAD DESCRIPTION QTY

CONNECTED

LOAD

PER ITEM

49 Spud Winch #1 1 480V, 3 PHASE 44.8 0.00 0.00 0.00 0.00 0.90 40.28 0.90 40.28 0.00 0.00 0.00 0.00 0.90 40.28 0.90 40.28 50 Spud Winch #2 1 480V, 3 PHASE 44.8 0.00 0.00 0.00 0.00 0.90 40.28 0.90 40.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 51 Spud Winch #3 1 480V, 3 PHASE 44.8 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 52 Spud Winch #4 1 480V, 3 PHASE 44.8 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 53 Deck Winch Port ‐ 40 ton 1 480V, 3 PHASE 3.7 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 54 Deck Winch Stbd ‐ 40 ton 1 480V, 3 PHASE 3.7 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 55 480V to 240VAC ‐ 45 KVA Transormer 1 480V, 3 PHASE 36.00 0.31 11.17 0.31 11.17 0.11 3.86 0.11 3.86 0.31 11.17 0.31 11.17 0.11 3.97 0.11 3.97 56 480V to 208/120VAC ‐ 45 KVA Transormer 1 480V, 3 PHASE 36.00 0.25 9.11 0.28 10.22 0.35 12.71 0.45 16.07 0.29 10.31 0.32 11.67 0.34 12.41 0.41 14.77 57 Crane Slip Ring Service Load per Seatrax (200A @ 480V) 1 480V, 3 PHASE 56.2 0.08 4.70 0.49 27.55 0.08 4.70 0.49 27.55 0.75 42.15 0.75 42.15 0.08 4.70 0.49 27.55

TOTAL 480VAC LOAD 25.0 48.9 101.8 128.1 63.6 65.0 61.4 86.6

ITEM NO. Gensets eKW

GENSET # 1 80 0 0.00 0 0.00 1 80.00 1 80.00 1 80.00 1 80.00 1 80.00 1 80.00

GENSET # 2 80 0 0.00 0 0.00 1 80.00 1 80.00 0 0.00 0 0.00 0 0.00 1 80.00

Shore Power 100 0 0.00 1 100.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 Standlaone Generator 40 1 40.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00

ELECTRIC LOAD PER GENSET % 0.62 0.49 0.64 0.80 0.80 0.81 0.77 0.54

NO OF GENSET ON LOAD - 1 1 2 2 1 1 1 2

**Note: Higher load factors were considered in operating condition 3, that the loads listed above (Crane Slip Ring Loads); to be conservative.

480V MAIN SWITCHBOARD

OPERATING

CONDITION - 04

WINTER

Operating Condition 2: Lifting two spuds simultaneously, crane general service loads except barge service loads Operating Condition 3: Crane general service, crane heating and barge service loads

OPERATING

CONDITION - 03

SUMMER

OPERATING

CONDITION - 04

SUMMER

OPERATING

CONDITION - 01

WINTER

OPERATING

CONDITION - 02

WINTER

OPERATING

CONDITION - 03

WINTER

Operating Condition 4: Lifting one spud, crane general service loads except barge service loads

Operating Condition 1: Barge service loads and crane general service loads

LEGEND:

OPERATING

CONDITION - 01

SUMMER

OPERATING

CONDITION - 02

SUMMER

MDC MCCAULEY FLOATING CRANE

160'x160'x12"

AC VOLT DROP CALCULATIONS

MDC PROJECT: 2989

DWG NO: 850-B725-01

REV-P1

9-Nov-2018

TECHNOLOGY ASSOCIATES, INC.

NAVAL ARCHITECTS, MARINE ENGINEERS, MARITIME SOLUTIONS

2045 LAKESHORE DRIVE, SUITE 526

NEW ORLEANS, LA 70122

WWW.NAVALARCHITECTS.US

Tel: (504)-282-6166 Fax: (504)-280-3311

This Document design, concept, and specification are the intellectual property of

TECHNOLOGY ASSOCIATES INC. and contain information which is proprietary to

Technology Associates, Inc. This information is furnished with the express understanding that the recipient recognizes the proprietary nature of this information and will not copy or alter it in any manner, nor transfer it, use it for manufacture, sell it, or use it in any way to the detriment of Technology Associates, Inc. without the express written consent of this firm. The recipient further agrees not to disclose the information herein to any other party except for the purpose contracted for with Technology Associates, Inc.

Load Volts Connected Wire AWG Amps in Cable Phase Length Circular Mil Area of the Conductor Voltage Drop Voltage Drop %

Units [V] - I [A] L [ft] Circular Mils [V] [%]

Generator Set 1 to Switchboard 480 2/0 173 3 15 133000 0.4 0.1%

Generator Set 2 to Switchboard 480 2/0 173 3 15 133000 0.4 0.1%

Stand-By Generator to Switchboard 480 4 83 3 10 41700 0.4 0.1% Shore Power Disconnect to Shore Power Interlock 480 3/0 201 3 100 168000 2.7 0.6% Shore Power Interlock to Shore Power Circuit Breaker 480 3/0 201 3 15 168000 0.4 0.1% Shore Power Circuit Breaker to Shore Power Isolation Transformer 480 3/0 201 3 15 168000 0.4 0.1% Shore Power Isolation Transformer to Switchboard 480 3/0 201 3 15 168000 0.4 0.1%

Switchboard to Spud Winch #1 VFD 480 2/0 173 3 100 133000 2.9 0.6%

Spud Winch #1 VFD to Spud Winch #1 480 2/0 173 3 20 133000 0.6 0.1%

Switchboard to Spud Winch #2 VFD 480 2/0 173 3 100 133000 2.9 0.6%

Spud Winch #2 VFD to Spud Winch #2 480 2/0 173 3 20 133000 0.6 0.1%

Switchboard to Spud Winch #3 VFD 480 2/0 173 3 45 133000 1.3 0.3%

Spud Winch #3 VFD to Spud Winch #3 480 2/0 173 3 20 133000 0.6 0.1%

Switchboard to Spud Winch #4 VFD 480 2/0 173 3 45 133000 1.3 0.3%

Spud Winch #4 VFD to Spud Winch #4 480 2/0 173 3 20 133000 0.6 0.1%

Switchboard to Deck Winch Port - 40 ton 480 14 24 3 80 4110 10.4 2.2%

Switchboard to Deck Winch Stbd - 40 ton 480 14 24 3 80 4110 10.4 2.2% Switchboard to Crane Slip Ring Service Load (Heating & Lighting) 480 1 131 3 57 83700 2.0 0.4%

Switchboard to 45KVA Transformer 1 480 1/0 150 3 20 106000 0.6 0.1%

Switchboard to 45KVA Transformer 2 480 1/0 150 3 20 106000 0.6 0.1% 45KVA Transformer 1 to Distribution Panel P201 208 1/0 150 3 20 106000 0.6 0.3% 45KVA Transformer 2 to Distribution Panel P202 240 1/0 150 3 20 106000 0.6 0.3%

DP P201 to Fuel Transfer Pump 208 12 29 3 24 6530 2.4 1.1%

DP P201 to Deck Lighting Circuit #1 120 4/0 232 1 125 212000 3.5 2.9%

DP P201 to Portable Aux. Bilge Pump 120 8 48 3 70 16500 4.5 3.8%

DP P201 to Deck Winch Heater 1 & 2 120 4 83 1 61 41700 3.1 2.6%

DP P201 to Genset Battery Charger 120 14 24 1 15 4110 2.3 1.9%

DP P201 to Spud Winch Heater # 1& 2 120 1/0 150 1 100 106000 3.7 3.0%

DP P201 to DC Battery Charger 120 6 65 1 57 26300 3.6 3.0%

DP P201 to Spud Winch Heater # 3 & 4 120 8 48 1 45 16500 3.4 2.8%

MDC 2989 FLOATING CRANE - VOLTAGE DROP CALCULATIONS

850-B725-01 MDC 2989 MCCAULEY REPLACEMENT

TAI 1208 1

Load Volts Connected Wire AWG Amps in Cable Phase Length Circular Mil Area of the Conductor Voltage Drop Voltage Drop %

Units [V] - I [A] L [ft] Circular Mils [V] [%]

MDC 2989 FLOATING CRANE - VOLTAGE DROP CALCULATIONS

DP P201 to Deck Lighting Circuit #2 120 4/0 232 1 125 212000 3.5 2.9%

DP P201 to Deck Lighting Circuit #3 120 4/0 232 1 125 212000 3.5 2.9%

DP P201 to Flood Lighting Circuit #1 120 4/0 232 1 125 212000 3.5 2.9%

DP P201 to Deck Lighting Circuit #4 120 4/0 232 1 125 212000 3.5 2.9%

DP P201 to Module Bucket 120 2 111 1 80 66400 3.5 2.9%

DP P201 to Flood Lighting Circuit #2 120 4/0 232 1 125 212000 3.5 2.9%

DP P201 to Genset Block Heater 120 10 38 1 15 10400 1.4 1.2%

DP P201 to Ship Receptacle # 1 120 4/0 232 2 200 212000 5.6 4.7%

DP P201 to StandBy Genset Block Heater 120 14 24 1 15 4110 2.3 1.9%

DP P201 to Switchboard Heater 120 14 24 1 5 4110 0.8 0.6%

DP P201 to Ship Receptacle # 2 120 4/0 232 2 200 212000 5.6 4.7%

DP P201 to Flood Lighting Circuit #3 120 4/0 232 1 125 212000 3.5 2.9%

DP P201 to Flood Lighting Circuit #4 120 4/0 232 1 125 212000 3.5 2.9%

DP P202 to Welder 220 4 83 3 100 41700 4.4 2.0%

DP P202 to Plasma Cutter 220 6 65 3 115 26300 6.4 2.9%

DP P202 to Welding Invertor 220 10 38 3 80 10400 6.5 3.0%

DP P202 to Deck Receptacles 13.2kw #1 220 6 65 3 65 26300 3.6 1.6%

DP P202 to Deck Receptacles 13.2kw #2 220 6 65 3 115 26300 6.4 2.9%

DP P202 to Deck Receptacles 13.2kw #3 220 6 65 3 65 26300 3.6 1.6%

DP P202 to Deck Receptacles 13.2kw #4 220 6 65 3 115 26300 6.4 2.9%

DP P202 to Deck Receptacles 4.4 kw #5 220 10 38 3 65 10400 5.3 2.4%

DP P202 to Deck Receptacles 4.4 kw #6 220 6 65 3 115 26300 6.4 2.9%

DP P202 to Deck Receptacles 4.4 kw #7 220 10 38 3 65 10400 5.3 2.4%

DP P202 to Deck Receptacles 4.4 kw #8 220 6 65 3 115 26300 6.4 2.9%

Single Phase: (2xKxLxI)/CM

Three Phase: (1.732xKxLxI)/CM

Note: K value (12.9 ohms-cmil/ft) is considered for copper cables

Voltage Drop Equations

850-B725-01 MDC 2989 MCCAULEY REPLACEMENT

TAI 1208 2

Amps Circular

Mils S/Y Std. AWG (kcmil) (mm2) Ω/m Ω/ft

24 4110 T4 14 4.11 2.08 7.69

29 6530 T6 12 6.53 3.31 5.08

38 10400 T10 10 10.4 5.26 3.35

48 16500 T16 8 16.5 8.37 0.7 2.3

59 20800 T20 7 20.8 10.5 0.58 1.9

65 26300 T26 6 26.3 13.3 0.46 1.5

75 33100 T33 5 33.1 16.8 0.33 1.1

83 41700 T41 4 41.7 21.2 0.29 1

99 52600 T52 3 52.6 26.7 0.23 0.8

111 66400 T66 2 66.4 33.6 0.18 0.6

131 83700 T83 1 83.7 42.4 0.14 0.5

150 106000 T106 1/0 106 53.5 0.12 0.4

173 133000 T133 2/0 133 67.4 0.09 0.3

201 168000 T168 3/0 168 85 0.08 0.3

232 212000 T212 4/0 212 107 0.07 0.2

259 250000 T250 250 126.7 0.065 0.2

273 262000 T262 262 133.1 0.06 0.2

290 300000 T300 300 152 0.055 0.2

298 313000 T313 313 158.7 0.05 0.2

317 350000 T350 350 177.3 0.045 0.15

332 373000 T373 373 189.4 0.04 0.1

342 400000 T400 400 203 0.04 0.1

382 444000 T444 444 225.2 0.04 0.1

393 500000 T500 500 253.3 0.04 0.1

407 535000 T535 535 271.3 0.04 0.1

440 600000 T600 600 304 0.04 0.1

474 646000 T646 646 327.6 0.04 0.1

494 750000 T750 750 380 0.04 0.1

516 777000 T777 777 394.2 0.04 0.1

592 1000000 T1000 1000 506.7 0.04 0.1

644 1111000 T1111 1111 563.1 0.04 0.1

Area BOSTRIG P Cable y = 14.815x-0.895 R² = 0.9836

0.5

1.5

2.5

0 20 40 60 80 100 120 140 160 180 200

Chart Title

850-B725-01 MDC 2989 MCCAULEY REPLACEMENT

TAI 1208 3

https://en.wikipedia.org/wiki/Circular_mil

EM1

850-B554-02_REV P1_SPUD WINCH SIZING CALCULATIONS_11-19-18
TAI 1208 SPUD WEIGHT AND WINCH SIZING CALCULATIONS_FINAL
850-B630-01_REV P1_FUEL OIL SYSTEM ARRANGEMENT_11-8-18
850-B630-02 REV P1 FUEL OIL SYSTEM CALCULATIONS_11-8-18
850-B660-01_Rev P1_Bilge System Schematic Arrangements_11-8-18
850-B670-01_Rev P1_VENTS, SOUNDS, OVERFLOWS, AND FILLS_11-06-18
850-B710-01_REV P2_AC LOAD ANALYSIS_11-09-18
850-B720-01_REV P1_AC ONE LINE_11-09-18
850-B725-01_REV P1_AC VOLTAGE DROP CALCULATIONS_11-09-18
850-B730-01_REV P1_LIGHTING ARRANGEMENTS_11-09-18
850-B730-02_REV P1_RECEPTACLE PLAN_11-09-18
850-B730-03_REV P1_NAVIGATION LIGHTING ARRANGEMENTS_11-02-18
4836A_R1 - General Arrangement, General Assembly
4836B_R1 - General Arrangement, Kingpost
4836C_R1 - Weights & CG
4836D_R1 - General Arrangement, 140ft Boom

File details come from the government source that posted it.