W912BU-16-R-0058.pdf

PDF 291 KB Posted

Attached to
Irvington Replacement 2016 Federal contract opportunity
Solicitation number
W912BU-16-R-0058
Issued by
Department of the Army Corps of Engineers Engineering District Philadeplhia

About this file

Solicitation

View the file

Other files for this federal contract opportunity

Other files attached to Irvington Replacement 2016, newest first.
File Type Posted
APPENDIX_D_PPEVal.pdf PDF
boat_cabin_arrangement_060616.pdf PDF
Past_Performance_Letter_Attachment.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CODE

(Hour)

PAGE(S)

until 02:00 PM local time 18 Aug 2016

X

A X B X C

D

EX

X G F 67 - 72

73 - 76 X H 77 - 80 megan.m.mcmullen@usace.army.mil

RATING PAGE OF PAGES

7. ISSUED BY

(Date)

IMPORTANT - Award will be made on this Form, or on Standard Form 26, or by other authorized official written notice.

Previous Edition is Unusable 33-134 STANDARD FORM 33 (REV. 9-97)

Prescribed by GSA FAR (48 CFR) 53.214(c)

1 80

(If other than Item 7)

15A. NAME 16. NAME AND TITLE OF PERSON AUTHORIZED TO

AND

ADDRESS

SIGN OFFER (Type or print)

OF

OFFEROR

AMENDMENT NO. DATE

15B. TELEPHONE NO (Include area code) 17. SIGNATURE15C. CHECK IF REMITTANCE ADDRESS

IS DIFFERENT FROM ABOVE - ENTER

SUCH ADDRESS IN SCHEDULE.

18. OFFER DATE

1. THIS CONTRACT IS A RATED ORDER

UNDER DPAS (15 CFR 700)

2. CONTRACT NO.

W912BU 8. ADDRESS OFFER TO

See Item 7

9. Sealed offers in original and 3 copies for furnishing the supplies or services in the Schedule will be received at the place specified in Item 8, or if handcarried, in the depository located in

CAUTION - LATE Submissions, Modifications, and Withdrawals: See Section L, Provision No. 52.214-7 or 52.215-1. All offers are subject to all terms and

See Instructions to Offerors conditions contained in this solicitation.

10. FOR INFORMATION

CALL:

A. NAME (NO COLLECT CALLS)

MEGAN M MCMULLEN 215-656-6765

11. TABLE OF CONTENTS

SOLICITATION/ CONTRACT FORM

SUPPLIES OR SERVICES AND PRICES/ COSTS

2 - 3

X I CONTRACT CLAUSES

DESCRIPTION/ SPECS./ WORK STATEMENT X

PACKAGING AND MARKING

4 - 41 J LIST OF ATTACHMENTS

INSPECTION AND ACCEPTANCE

DELIVERIES OR PERFORMANCE

43 - 44

X K

REPRESENTATIONS, CERTIFICATIONS AND

OTHER STATEMENTS OF OFFERORS

CONTRACT ADMINISTRATION DATA 45 - 46 X

SPECIAL CONTRACT REQUIREMENTS

OFFER (Must be fully completed by offeror) 47 - 50 X M

L INSTRS., CONDS., AND NOTICES TO OFFERORS

EVALUATION FACTORS FOR AWARD

NOTE: Item 12 does not apply if the solicitation includes the provisions at 52.214-16, Minimum Bid Acceptance Period.

is inserted by the offeror) from the date for receipt of offers specified above, to furnish any or all items upon which prices are offered at the price set opposite each item, delivered at the designated point(s), within the time specified in the schedule.

13. DISCOUNT FOR PROMPT PAYMENT

(See Section I, Clause No. 52.232-8)

14. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments

AMENDMENT NO. DATE

to the SOLICITATION for offerors and related documents numbered and dated):

FACILITY

12. In compliance with the above, the undersigned agrees, if this offer is accepted within calendar days (60 calendar days unless a different period

SOLICITATION, OFFER AND AWARD

X

(X) SEC. DESCRIPTION (X) SEC. DESCRIPTION PAGE(S)

PART I - THE SCHEDULE

26. NAME OF CONTRACTING OFFICER (Type or print) 27. UNITED STATES OF AMERICA 28. AWARD DATE

EMAIL:TEL: (Signature of Contracting Officer)

CODE CODE

B. TELEPHONE (Include area code) C. E-MAIL ADDRESS

AWARD (To be completed by Government)

19. ACCEPTED AS TO ITEMS NUMBERED 20. AMOUNT 21. ACCOUNTING AND APPROPRIATION

22. AUTHORITY FOR USING OTHER THAN FULL AND OPEN COMPETITION:

10 U.S.C. 2304(c)( ) 41 U.S.C. 253(c)( ) (4 copies unless otherwise specified)

23. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM

24. ADMINISTERED BY (If other than Item 7) CODE 25. PAYMENT WILL BE MADE BY CODE

PART IV - REPRESENTATIONS AND INSTRUCTIONS

PART III - LIST OF DOCUMENTS, EXHIBITS AND OTHER ATTACHMENTS

51 - 65

PART II - CONTRACT CLAUSES

US ARMY ENGINEER DISTRICT, PHILADELPHIA

CONTRACTING DIVISION

WANAMAKER BUILDING

100 PENN SQUARE EAST

PHILADELPHIA PA 19107-3390

FAX:

TEL:

FAX:

TEL:

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

SOLICITATION

6. REQUISITION/PURCHASE NO.5. DATE ISSUED

19 Jul 2016

4. TYPE OF SOLICITATION

SEALED BID (IFB)

NEGOTIATED (RFP)

[ X ]

3. SOLICITATION NO.

W912BU-16-R-0058

Section B - Supplies or Services and Prices

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 1 Job Irvington Replacement

FFP

The U.S. Army Corps of Engineers, Philadelphia District has a requirement for one

(1) foil supported aluminum catamaran, including delivery to Mobile, Alabama.

Vessel shall be arranged with a single level house, waterjet propulsion, twin generators, and a survey transducer moon pool with retractable strut.

This line item is for the construction, testing, and deliver of the vessel.

Period of performance including delivery is twenty (20) months after notice to proceed.

ALL LINE ITEMS MUST BE FILLED OUT OR THE OFFEROR WILL BE

DEEMED NONRESPONSIVE.

Please see the attached scope of work.

FOB: Destination

NET AMT

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0002 1 Job Data Rights

FFP

This line item is in accordance with Section H, Special Contract Requirements, Data Rights: Table 1. Please enter the total cost amount for data rights in this line item.

All offerors are required to fill in this line item. Offerors are instructed to enter a dollar amount or the offeror must enter a "NO CHARGE (N/C)" notation on this line item.

ALL LINE ITEMS MUST BE FILLED OUT OR THE OFFEROR WILL BE

DEEMED NONRESPONSIVE.

NET AMT

Section C - Descriptions and Specifications

SCOPE OF WORK

Specifications for One Foil Supported Catamaran Hydrographic Surveyboat

1. Overall:

Vessel shall be a foil supported aluminum catamaran. Vessel shall be arranged with a single level house, waterjet propulsion, twin generators, and a survey transducer moon pool with retractable strut. Particulars are delineated below.

2. Operation Hours Profile and Operational Area:

Operational profile is as follows: 1,500 hours per year. 30% time at cruise speed (85% power), 60% time at survey speed (20% power), and 10% time at max speed (100% power). Maximum duration at max power 1 hour.

Vessel operational area is open ocean around Mobile, AL and the northern Gulf Coast, within 20 miles of shoreline.

3. Hull:

a. Hull Characteristics – Hull to be Foil Supported Catamaran with freeboard and tunnel height sufficient for open water operation. The hull shall be flush (non-stepped) deck. A wave breaker section shall be provided in the tunnel in the bow.

The hull dimensions shall meet the following:

Length, Bow to Transom - 62 to 64 feet.

Maximum Beam - 24 to 26 feet.

Min. freeboard at bow and stern - 6.5 Ft. and 3.5 Ft. respectively, at rest at full load.

Min. tunnel height above. WL. at bow and stern - 6.5 Ft. and 2.0 Ft. respectively, at rest at full load.

b. Boarding over Bow – The hull deck shall provide a path and rail gate for boarding over bow.

The main deck shall extend to the forward extent of each demi-hull.

4. Support Foils:

Foils shall be integrated into the hull structure. Foils shall be fully machined aluminum. The foils may be welded or bolted to the hull.

Foil construction and mounting system shall anticipate collision and damage from floating debris.

If bolting is used, watertight cofferdams shall be provided around the bolts where they enter hull watertight areas.

5. Intact and Damaged Stability:

The vessel must satisfy:

Intact Stability requirements of 46 CFR 170.173, for open ocean operation, and Damaged stability subdivision requirements of 46 CFR 171.070, Type II.

6. Structure and Structural Design Standards:

a. Structure – All aluminum (plate and stiffeners) in the hull shall be 5000 series aluminum material.

No welded 6000 series aluminum shall be used.

6000 series aluminum may be used if required welding is accomplished by the Friction Stir Welding process.

b. Design Standards - Structure and systems shall be in accordance with high speed craft rules from one of the IACS classification societies. Design shall be adequate for between 25 and 30 knot speed in 6 foot significant wave height. The Contractor shall identify both the classification standard and the design speed in their proposal.

7. Coast Guard Subchapter T and USACE Safety Manual:

The vessel shall be designed and constructed in accordance with US Coast Guard Subchapter "T" requirements for 25 passengers as well as in accordance with the latest revision of the USACE EM 385-1-1 Safety and Health Requirements Manual.

8. Deckhouse Arrangements:

a. Arrangements

Deckhouse shall be single level with centerline control station, and dual survey stations.

Useable floor space shall not be less than 300 sq. Ft. Headroom from the lowest point shall not be less than 6 feet 8 inches.

The deckhouse configuration shall provide best practical 360 degree visibility from the operator’s station. Windows shall be provided all around the house. Doors shall have windows.

No impediments to unobstructed 360 degree visibility may be installed above desk top height.

Stairs shall be provided down into each hull. Access shall also be provided from within the deckhouse into the engine spaces. Access into the engine space shall be via inclined ladder.

Side Doors shall be provided P&S in line with the pilot station. Side decks outside of the deckhouse shall be minimum 30 inches wide but can be up to 36 inches wide.

A 36” wide door shall be provided in house after bulkhead.

Two Survey stations shall be provided, one each port and starboard in the house.

A settee shall be provided and shall include storage for 35 life jackets. A standing height survey plot table shall be provided near the operator’s station. The plot table shall include two full size sliding drawers for chart and plot storage along with a minimum of two sliding cabinets configured for hanging files, and two additional sliding cabinets for general storage.

A vertical ladder shall be provided on the house aft bulkhead to access the house roof.

b. House Arrangements Sketch

A house Arrangements Sketch is included with this RFP, to provide guidance pertaining to a workable house arrangement.

The Arrangement Sketch is not binding, and proposers may provide alternative arrangements, so long as the requirements delineated in paragraph 8.a above are satisfied.

9. Windows and Visibility:

Windows shall be suitable for open ocean operation. Forward house windows shall rake forward at the top.

Spacing and mullions between windows shall be minimized for best all around visibility. Less obstructed vision is better. The number of windows across the front of the house shall be limited to preserve visibility.

The windows on the aft of the house shall be as tall as possible. Visibility shall be maximized

Window frames shall be configured for clamp-in installation, with no fasteners through the external frame surface.

Forward house windows shall be electrically heated for defrosting.

Two windows on each house side shall be slide opening. All doors shall be provided with windows of equal height to the house windows, and shall be aligned with the windows.

Forward and Aft windows shall not be tinted. Side windows shall be tinted to the maximum allowed by regulatory authority. Tinted Mylar shades shall be provided for all forward and aft windows. The mylar shades shall be on chain rollers. Additionally, blackout shades on rollers shall be provided for all side windows.

The forward windows shall each be fitted with heavy duty Linear Marine Wipers. The wipers shall sweep clear a minimum of 80% of the clear glass window area and be equipped with variable speed options. The wipers shall be equipped with an automatic glass cleaning function with its own window washing fluid reservoir with accessible filling station.

There shall be no windows in the hull.

10. Hull Arrangements:

a. Head and Galley – A head and a galley shall be located in the hulls. The head shall consist of vanity with sink, and toilet. The head shall also incorporate a handheld shower and deck drain.

The galley shall consist of cabinet with counter, sink, microwave, and 12 cu.ft. refrigerator.

Appliances shall be stainless steel type finish. All appliance and cabinet doors shall have an unobstructed swing.

Both head and galley shall be fitted with exhaust fans routed outdoors above the main deck.

b. Bunk Room – A two person bunk room shall be provided in one hull. Bunks and lockers for two persons shall be provided.

c. Engine Spaces – An engine space shall be located in each hull. Access shall be provided into the engine space directly from within deckhouse. Access into the engine space from the deckhouse shall be via inclined or vertical ladder.

Propulsion engines and generators shall be located in the engine spaces. Propulsion engines and generators shall be located aft clear of the deckhouse and all of its structure.

Engines and gensets shall be accessible and removable vertically aft of the deckhouse via a gas-assisted opening deck hatch.

Note that main engine silencers are not located in the hull. They are incorporated into the waterjet transom platforms.

d. Work Benches - Each engine space shall be provided with a work bench and a lockable tool rack or box.

e. Watertight Bulkheads - Watertight bulkheads shall be provided as required to meet damaged stability requirements. Watertight bulkheads shall be welded double continuous both sides at the hull & deck plating.

11. Machinery Clearances and Headroom:

A minimum of 18 inches clear space shall be provided all around propulsion engines, gears and waterjets.

A minimum of 18 inches shall also be provided all around gensets, except that gensets configured for one side access may be mounted against bulkheads.

A minimum clear headroom of 6 feet shall be provided in the Engine Space.

12. Fire Protection and Ventilation:

Engine spaces shall be provided with fixed USCG approved gas fire extinguishing systems. The systems shall be fitted with both automatic actuation and remote actuation from the operator's station and on the exterior of the house after bulkhead.

The engine spaces shall be fitted with power ventilation blowers.

All spaces below the main deck shall be provided with forced air ventilation of at least 80 CFM.

Engine space air intakes shall be equipped with mist separators.

All engines shall be equipped with remote fuel shut offs operated by pull handles located at the Operator’s Station and on the exterior of the house after bulkhead.

13. Bilge Pump and Alarm Systems:

Each hull compartment shall be provided with:

A 120 VAC self priming diaphragm or vane bilge pump, capacity 23 GPM.

An automatic 24 VDC bilge pump, minimum 1000 GPH, rated at the discharge head.

Each bilge pump shall have a separate discharge line and dedicated overboard discharge through hull penetration. The discharge line shall be routed from the pump up to close under the hull overhead. From there, the discharge line shall run down to a through hull discharge located at 12 inches above the waterline.

Each hull compartment shall be provided with an individual bilge level alarm. Bilge alarms shall be AC powered with DC backup.

Each bilge pump shall have an ON/OFF/AUTO switch at the operator’s station. The ON position shall be spring loaded.

A bilge panel shall be provided at the operator’s station with light indicators for each bilge pump and bilge alarm, together with the switches for each bilge pump.

Each hull and cross deck compartment shall also be provided with the Arid Bilge System (www.aridbilge.com). The Arid Bilge System shall be equipped with a compatible oily water separator to treat the bilge water prior to overboard discharge.

14. Transom Platform (Silencers):

Transom platforms shall be provided over the waterjets.

The platforms shall serve as:

Protection for the waterjets Divers' platforms & ladder.

Main Engine Silencers

a. Protection for the Waterjets

The platforms shall extend 3 inches beyond the aftermost projection of the waterjets. The platforms shall be edged with 2 inch or larger round pipe. The platform outboard surface shall be flush with the hull side shell. The platform inboard surface shall be flush with the inboard side of the hull.

b. Diver Platform

To provide diver access, the transom of each hull shall be provided with 45 degree incline built in stairs extending down from the hull deck to the diving platforms. Stair width shall be 24 inches minimum. Hinged aluminum deck plates shall be provided over the steps at the deck level.

The two divers platforms shall be equipped for and fitted with one removable divers ladder with mounting points on both the starboard and port platforms. The ladder shall be hinged off the stern or the inboard edge of each platform. In the stowed position the ladder shall rest on top of the platform. There shall be a vibration isolation device provided for the ladder in the stowed position. In the deployed position, the ladder shall extend from the platform deck to 4 feet below water level.

The ladder shall be “T” configuration with a center spine support and steps on either side of the spine support. The ladder shall be adequate for 350 pound total diver’s weight.

c. Main Engine Silencer

The platforms shall be built in box configuration with internal baffles and piping to serve as main engine wet exhaust silencers. The silencer shall be designed specifically for the propulsion engine selected by the Contractor.

The Contractor shall retain the services of Dr. Joseph Sullivan, Sullivan Consulting Services (e-mail scs.joe1@comcast.net, phone 765 409 0927) to design the platform silencer.

Silencer acoustic performance shall be matched to equal the performance of the Centex Marine Dual Stage MKII Vernatone muffler, for the firing frequency of the diesel engine at maximum RPM and power.

One of the transom platforms to be determined by the government shall be tested to validate the silencer acoustic performance. The Contractor shall retain the services of Dr. Sullivan on site during trials for the acoustic performance test of the silencer.

15. Outfit:

a. Flooring & Sheathing - Deckhouse floors shall be covered with light weight single piece foam anti-fatigue matting. Tiled anti-fatigue matting is not acceptable. Head, galley, and bunk room area floors shall be covered with an epoxy poured floor. House overhead shall be white, except in way of the operator’s station, where it shall be black. House, hull stateroom, head, and galley sheathing shall be light gray.

b. Counters, Cabinets & Joinery - All counter tops shall be high pressure laminate. All cabinetry shall be wood veneer finish with positive door and drawer closures. Cabinet and trim joinery shall be light wood grain finish

c. Insulation – Thermal and acoustic insulation shall be provided as required to meet the noise and temperature requirements in this specification. Insulation in machinery spaces shall be faced with oil resistant and tear resistant material.

c. Navigation Lights – Navigation lights shall be provided in accordance with USCG Requirements for International Waters. The lights shall include lighting for limited maneuverability (for the survey operation). All navigation lights shall be USCG approved LED lights.

d. Mast – A mast shall be provided as required for: navigation lights, limited maneuverability day shapes, US Flag, and Corps of Engineers Flag. The mast shall incorporate a mounting for the navigation GPS receiver, at the top end of the mast. The mast shall be hinged above the level of the Radar Arch to swing down to allow for servicing.

e. Radar Arch– A radar arch shall be provided, minimum 6 feet wide with a flat 2 foot surface for antenna mounting. The radar scanner shall be provided and installed. The arch shall be configured so the radar scanner is on centerline, and has no obstructions ahead or to either side.

f. Survey Antenna Arch – A GPS mounting arch shall be provided in immediate proximity to the survey strut. The arch shall be aluminum tube construction and shall be isolated from vibration and free from all measurable motion. The arch shall be a minimum of 8 feet from end to end and shall be suitable for mounting of survey GPS sensors.

g. Seating - The operator's station shall be fitted with one helm chair to be located on centerline, similar to Llebroc Bandera Series 2 Helm Chair. Both survey stations shall also be fitted with marine shock mitigation seats, similar to Stidd model 500 V5, with high back.

h. Trash Pump – The Contractor shall supply a 120V powered trash pump. The pump shall be rated for a minimum of 185 gal/min and have a solids handling capability of 13/16 of an inch.

The pump shall have a quick clean out port. The pump shall be equipped with two 25’ lengths of hose suitable for operation in conjunction with that pump.

i. Dock Box – The Contractor shall supply a fiberglass dock box of sufficient size to permanently store the trash pump and its hose. The dock box shall be permanently mounted on the back deck of the vessel on the port side.

j Canopy – The Contractor shall fabricate and install an aluminum canopy over the deck aft of the deckhouse. The canopy shall extend for 5-7 ft aft of the deckhouse structure and shall span the width of the deckhouse. The canopy shall be removable to allow for the removal of the engines and generators out of their respective hatches.

k. Air Compressor – The Contractor shall supply a 2 horsepower, 4 gallon, 135 PSI, 120 volt air compressor similar to Hitachi. This shall be a portable air compressor, but a suitable and secure spot for its permanent stowage shall be designed by the Contractor.

16. Anchor & Mooring Equipment:

a. Anchor Equipment:

An anchor & windlass system shall be provided with a rope locker. The anchor windlass shall be Lewmar V series, model V-5 Gypsy/Drum or equal, DC powered. The following specifics shall be provided:

Sized for 5/8 nylon rope and 3/8 inch anchor chain.

Maximum pull not less than 3,500 pounds.

Line take up speed at nominal (300 pound) pull at least 56 FPM.

Operation shall be provided local to the windlass as well as remotely from the operator’s station.

A 70 pound danforth pattern anchor shall be provided. The anchor shall be mounted on a self launching stowage bracket fabricated into the hull on centerline. A line chock shall be provided as part of the anchor stowage bracket. A permanent anchor hold back shall be provided.

An anchor line shall be provided. The line shall consist of 300 feet of 5/8, three strand nylon anchor line, and 12 feet of 3/8 inch stainless steel chain anchor lead.

A rope locker shall be provided in the hull such that the anchor line will feed from the anchor windlass into the locker. The locker shall be watertight with an overboard drain. A watertight hatch, minimum 18 inch clear diameter, shall be provided into the rope locker.

b. Mooring Equipment

Sampson Posts shall be provided for mooring. No cleats shall be used. The Sampson Posts shall be designed for line pull equal to 10% of the vessel loaded displacement.

Four Sampson posts shall be provided along each side of the hull. One additional Sampson post shall be provided forward for the anchor line.

An open line chock shall be provided at each Sampson post.

The Sampson Posts and chocks shall be sized to accept 1 inch line.

A Sampson Post tie off of for the sidescan sonar tow line shall be provided on centerline aft at the transom.

17. Fendering

a. Hull Fendering - Two tiers of fendering shall be provided.

The fendering shall be either non-marking white rubber or aluminum flat profile, faced with minimum 1/2” thick UV Resistant UHMWPE .

The upper tier fendering shall run around the perimeter of the hull approximately 6 inches below the main deck. The lower tier shall run around the hull and transom platforms at the level of the transom platform.

The fendering attachment to the hull shall not penetrate the hull, and shall not require access from the hull interior for replacement of the fendering. All nuts shall be easily accessible for removal or maintenance. Fendering attachment using threads into aluminum is not acceptable.

b. Docking Fenders – Six round cylindrical 18 inch diameter white fenders, similar to Jim Buoy shall be provided. Each fender shall be provided with 8 feet of double braid ¼ inch nylon line, spliced onto the fender eye.

18. Bow Push Knees

A Push Knee shall be provided at each bow to provide bow-on landing surface.

The push knees shall be vertical, and shall extend 12 inches above the deck, and 24 inches below the deck. Each push knee shall be faced with two vertical lengths of the UHMWPE hull fendering material to make an effective width of at least 8 inches.

19. Railings, Grab Bars & Boarding Ramp:

a. Railings - Deck edge railing and toe boards shall be provided around the entire deck perimeter. The railing shall be three tier, with maximum spacing between the tiers of 9 inches, 15 inches and 15 inches. The deck edge railing shall incorporate three entrance swing sections, 36 inches in clear width, one each port and starboard near the stern, and a third section for over bow entry. The toe board shall be a minimum of 1 in high and shall be provided with suitable drainage holes to allow water to completely drain off of the main deck.

Railings and a 3 inch minimum height toe boards shall also be provided on the deck house top on the port, starboard, and after sides.

3 tier removable railing shall be provided around the moon pool and attaching to the house after bulkhead.

The stern railing in way of the A-frame shall be removable to allow use of the sonar tow fish.

b. Overhead Grab Bars - Three rows of longitudinal overhead Grab Bars shall be provided on the deckhouse ceiling. The rows shall be located on the house centerline, and port & starboard 3 feet in from the house sides. The grab bars shall be of sufficient strength to support a person weighing 300 pounds.

Rails and mounting brackets shall be polished 316 stainless steel. Rail fasteners shall attach to structure in the overhead behind the ceiling, not to the ceiling material.

21. Doors & Hatches:

All exterior doors shall be weathertight dogged aluminum, similar to Freeman. Watertight aluminum hatches, similar to Freeman, shall be provided flush with the deck for entry into all hull compartments. All hatches shall be minimum size of 18”x24” and shall lock via a removable handle. Four (4) of these removable handles shall be provided. Watertight doors in bulkheads, where provided, shall be quick acting single lever type.

Purpose sized and built flush watertight hatches or flush watertight bolted plates shall be provided in the decks over the engines, gears and gensets. Engine hatches shall be large enough to allow removal of the engines with gears attached. Genset hatches shall be large enough to allow removal of the gensets complete, diesel and alternator end. The engine and genset access hatches shall be provided flush with the deck with lift assist gas struts.

22. Tanks:

The following capacities shall be provided. All amounts are minimums.

Fuel - 1,400 gallons Water – 100 to 150 gallons Black Water - 50 gallons Gray Water - 50 gallons

Fuel tanks shall be completely independent of the hull bottoms, and the hull inboard and outboard sides.

Fuel tanks shall be fitted for tape sounding. All tanks shall be fitted with remote digital read out tank level indication, with the level display at the operator's station.

Tank capacity tables shall be provided for the fuel tanks.

Fuel tanks shall have low point drains.

Fuel tank fills and vents shall be located at the house after bulkhead. Containment with rain proof closure shall be provided around the fill and vent station.

Black and Gray water tanks shall incorporate standard marina pump off connection systems, routed to the deckhouse side or after bulkheads.

Black and gray water tanks shall be fitted with an Ozone odor control system, Hughes Marine Environmental Technologies (940 627 7879) or equal.

23. Water Systems:

Hot and cold fresh water system and pressure set shall be provided for the head and galley. The cold water system shall also incorporate deck wash down hose bib stations, one each at the forward and after deckhouse bulkheads.

A two filter water filtration system shall be provided for potable water. Each filter shall be an identical filter similar to a 20 inch Pentek Big Blue, for 20 inch by 4 ½ inch filter elements.

The filters shall be plumbed in series. The first filter shall be provided with a 5 micron particle filter, and the second filter shall be provided with a carbon filter.

Galley and head sink drains shall be plumbed to an overboard discharge as well as the gray water tank. There shall be a valve that allows the flow to be directed either to the tank or overboard.

This valve shall be located local to the grey water tank.

The head shall be equipped with a vacuum assist flush macerating toilet. The toilet shall be plumbed to the black water tank and to a Type II Marine Sanitation Device (MSD) similar to

Ahead (www.aheadtank.com). There shall be a valve to direct waste flow to either the black water tank or the MSD. This valve shall be local to the MSD. The MSD shall be equipped to discharge overboard via a gravity discharge connection that will be capable of discharge at all vessel speeds.

24. Cruise Load Condition:

Cruise Load Condition is defined as lightship plus: 90% fuel, full water, 10% Gray and Black water, and the following on board loads:

Crew - 3 persons @ 225 pounds each.

Crew Stores & effects - 500 pounds Boat maintenance stores & equipment – 1,250 pounds Survey Gear & UPS Power Supplies – 1,000 pounds.

25. Minimum Cruise Speed:

Minimum cruise speed shall be 32 to 35 Knots, at the Cruise Load Condition, and 85% engine rated power.

The minimum cruise speed (at the cruise load condition) identified by the proposer shall be a contractual requirement.

26. Propulsion & Extended Warranty:

a. Propulsion:

Propulsion shall consist of twin diesels that meet the current EPA emission tier requirements with reverse gears, driving waterjets, with single lever 360 degree thrust vector controls.

Clutched neutral and reverse rotation back flush shall be provided.

The engine power and rating shall be adequate for the required cruise speed, and the operational profile. All other running gear shall be matched to the engine rating.

Engines shall have the following features:

Duplex aluminum or bronze cooling water strainers.

10 Micron duplex water separating fuel pre-filters (note filter flow rate to be sized for fuel burn plus fuel return).

2 micron duplex fuel final filters (note filter flow rate to be sized for fuel burn plus fuel return).

Wet exhaust.

24 VDC battery start

120/240 VAC block heaters Flex hose section at engine piping connections.

Portable lube oil change out pump shall be provided with hose and quick connections to engine and gear oil sumps.

Separate Shaft Tachometers shall be provided and installed for each propulsion shaft. The shaft tachometers shall display both shaft RPM, and shaft ahead/astern rotation direction. The Shaft Tachometer display shall be located at the Operator’s station.

Main Engines shall not have engine driven battery charging alternators. Starting batteries shall be charged by AC powered battery chargers.

Main Engines shall be provide with isolated starters.

Propulsion engine hull cooling water inlets shall be fitted with removable strainer plates. The cooling water overboard discharge shall be visible to the operator while standing on the main deck.

Each propulsion engine & gear shall have a separate dedicated cooling water intake system solely for that engine & gear. The propulsion engine & gear cooling water intake system may not be used to provide water to any other components or systems. Shutoff valves shall be easily accessible.

The manufacturer’s colored multi-function displays shall be provided both local to the engine and at the operator’s station for each engine. At a minimum these shall show:

RPM

Operating Temperature Oil Pressure Operational Alarms

b. Extended Warranty

Extended warranty shall be provided for the engines, gears, and waterjets.

The combination of standard warranty and extended warranty for the engines and gears shall provide warranty coverage for a total of 5 years after delivery of the vessel to the Government at Mobile.

The combination of standard warranty and extended warranty for the waterjets shall provide warranty coverage for a total of between 3 and 5 years after delivery of the vessel to the Government at Mobile. Longer warranty within this range is better.

27. Fuel Flow Metering:

A Floscan 7500/7600 fuel flow system shall be provided and installed for each propulsion engine. The system flow capacity shall be matched to the max rated flow of the engines. The flow sensors for the two engines shall be matched within 2%.

The Floscan displays shall be located at the operator’s station.

28. Generators and AC Electrical:

a. Generators:

Two 120/240 single phase diesel gensets shall be provided. The gensets shall be sized for the vessel electrical loads. Each genset shall be sized for the total vessel load.

Gensets shall have the following features:

Duplex aluminum or bronze cooling water strainers.

10 Micron duplex water separating fuel pre-filters (note filter flow rate to be sized for fuel burn plus fuel return).

2 Micron duplex fuel final filters (note filter flow rate to be sized for fuel burn plus fuel return).

120/240 VAC block heaters.

Wet exhaust with water-lift silencers.

24 VDC battery start Flex hose section at engine piping connections.

Automatic (operator selected) paralleling and load sharing.

Gensets shall not have engine driven battery charging alternators. Genset starting batteries shall be charged by AC powered battery chargers.

Gensets shall be provided with isolated starters.

The combination of standard warranty and extended warranty for the gensets shall provide warranty coverage for a total of 5 years after delivery of the vessel to the Government at Mobile.

Generator engine hull cooling water inlets shall be fitted with removable strainer plates. The generator cooling water inlet shall be a flush penetration on the hull and shall meet all manufacturer’s recommendations and guidelines for installation.

Each generator engine shall have a separate dedicated cooling water intake system solely for the engine. The generator engine water intake system may not be used to provide water to any other components or systems. Shutoff valves shall be easily accessible.

The cooling water overboard discharge shall be visible to an operator while standing on the main deck.

The manufacturer’s colored multi-function displays shall be provided both local to the generators and at the operator’s station for each generator. At a minimum these shall show:

RPM

Operating Temperature Oil Pressure Operational Alarms

b. AC Electrical

The AC electrical distribution system shall be configured with automatic electronic paralleling and load sharing gensets. The AC system shall also be provided with a split bus to allow the use of two non-synchronized shore power lines simultaneously.

The AC electrical system shall be in accordance with USCG Subchapter J, and with ABYC Section E, and with the NEC.

A single point ground shall be provided. All AC and DC cables shall be provided with a grounding conductor to provide a path for all equipment grounds back to the isolation ground bus in the switchboard and to the engine terminal (single point grounding).

Isolation of galvanic currents is required.

A ground fault detection system, (with ammeter and test switch) shall be provided.

No AC currents shall flow through the hull.

Duplex 120VAC 20 amp outlets shall be provided as follows:

Deckhouse interior - 5 Deckhouse interior – 5 (each with duplex AC outlets and duplex USB ports) Operator’s Console – 2 (each with duplex AC outlets and duplex USB ports) Head and galley spaces - 2 each Bunk room - 2 Engine spaces - 2 each (watertight) House exterior - 3 each (watertight) one on each end and one on top of the house.

Tank spaces/Lazzarette – 1 each (watertight)

Each AC panelboard shall be supplied with a minimum of (4) four spare breakers.

c. AC Equipment with Case Grounds

Case grounded equipment can provide alternative ground paths (to the single ground required in paragraph 28.b above).

In order to prevent alternative grounds, all case grounded equipment shall:

Be electrically isolated from the hull and house, or The case ground shall be removed and replaced with a ground conductor to the single ground point, such that there is no alternative ground path.

29. AC Lighting:

The AC lighting system shall consist of white LED fixtures for interior spaces, watertight white LED lights for the house exterior, and LED deck floodlights. Fixtures shall be provided as follows:

Deckhouse interior - 10, switched in pairs.

Head and Galley Spaces - 2 each space, one switch each space.

Bunk room - 2, one switch.

Engine and Jet Spaces - 2 each space, splash tight, one switch each space.

House exterior sides - 3 each side, one switch each side.

House exterior ends - 2 weathertight LED floods each end, 1 switch each end.

Tank/Mechanical spaces – 1 each space, splash tight

All gauges, controls , switches and indicators on the operators console shall be dimmable.

30. Air Conditioning System - Heating and Cooling

Heating and cooling shall be provided for the crew spaces. Each of the following spaces shall have their own heating/air conditioning system:

Pilothouse Head/Crew Accommodation Space Galley Space

The heating system shall be capable of maintaining 70 deg. F temperature in all crew spaces with outside temperatures at 0 deg. F.

The air conditioning system shall be water source, suitable for salt water. The cooling system shall be capable of maintaining 70 deg. F temperature in all crew spaces with outside temperatures at 100 deg. F. The cooling system shall be equipped with soft start for the cooling compressors, to prevent overload on the gensets.

The Contractor shall provide calculations showing the heating and cooling loads to be met by the HVAC system.

The Contractor shall also provide calculations to identify duct sizing and airflow for each duct discharge and each heating/cooling unit.

In order to ensure even cooling and heating, duct discharges shall be distributed, with some discharges in the house overhead.

All ducting shall be sheet metal with smooth interior. Flexible ducting shall not be used.

Each air conditioner shall have a separate dedicated cooling water intake system solely for the engine. The air conditioner water intake system may not be used to provide water to any other components. Shutoff valves shall be easily accessible.

HVAC shall be provided by a vendor with service facility local to the Mobile area.

31. Shore Power:

Two separate 120/240 VAC 50 amp shore power (240 VAC input power) systems shall be provided, supplied with split bus. The shore power system(s) shall be designed and installed to allow operation of the vessel electrical system from two non-synchronized shore power sources simultaneously.

Two 75 foot shore power cables shall be provided. Each of the shore power cables shall be stored on a reel mounted on the after bulkhead near the shore power receptacle.

The shore power shall comply with ABYC Section E.

The shore power systems shall each have a UL approved Isolation Transformer.

One shore power system shall provide power to the following:

AC receptacles AC lighting Battery Chargers Engine Room Fans Engine Block Heaters Generator Block Heaters AC Bilge Pumps

The other shore power system shall provide power to the HVAC system.

32. DC Electrical, Batteries and Chargers:

a. DC Electrical - The DC Electrical system shall meet the requirements of ABYC Section E and NEC.

In addition to the ABYC requirements, the following features shall be provided:

b. System Grounding - System shall be grounded type. Grounding and bonding shall be provided. All AC/DC cables shall be provided with a grounding conductor to provide a path for all equipment grounds back to the isolation ground bus in the switchboard and to the engine terminal (single point grounding). No DC currents shall flow through the hull.

c. Ground Fault Detection - A ground fault detection system (with ammeter) shall be provided for the DC system.

d. DC Equipment with Case Grounds

Case grounded equipment can provide alternative ground paths (to the single ground required in paragraph 32.b above).

In order to prevent alternative grounds, all case grounded equipment shall:

Be electrically isolated from the hull and house, or The case ground shall be removed and replaced with a ground conductor to the single ground point, such that there is no alternative ground path.

e. Batteries – Each main and genset engine shall be provided with sealed AGM marine starting batteries. The batteries shall be sized per the engine manufacturers’ requirements for starting above 32 deg. F.

A fifth battery bank for the “house” battery system shall be provided with four group 31 size AGM marine deep cycle batteries. The house batteries shall be sized to provide power for the total vessel DC load for a minimum of (3) three hours.

The “house” system shall provide power for:

navigation lights navigation gear, engines, gensets, waterjets, transducer strut system, DC lighting,

(3) 24V DC power supply (e.g. “cigarette lighter outlet) at helm station and each survey station computer rack DC power supply bilge pumps bilge alarms

All batteries shall be charged with AC chargers.

f. Battery Management – The vessel shall be provided with manual cross-over switches to allow each DC system to be powered by a separate battery bank in the event of a loss of power on any of the systems. Cross-over switches shall be provided between the following battery banks:

Port and Starboard main engines Port and Starboard gensets One main engine and the “house”

g. Battery Chargers - Each battery bank shall be charged by a separate AC powered marine battery charger, similar to Charles HQ series chargers. Each charger shall have a separate dedicated 120 VAC circuit.

The “house” battery charger shall be sized to provide power for the total vessel DC load plus the power required to recharge the batteries from a completely discharged state. Each charger shall be capable of recharging the batteries banks from a completely discharged state to 100% capacity in not more than (10) ten hours.

Chargers shall have the following features:

Settings for flooded, gel, AGM or lead-calcium batteries

Selectable two or three stage charging.

Battery Equalization

Auto-ranging input voltage compatible with generator power source

Temperature-compensated charging

Power factor corrected charging

Battery temperature sensor

Drip Proof housing.

UL Approved

33. Propulsion & Steering Control System

a. Propulsion & Steering Control System

The Contractor shall provide and install an integrated Propulsion & Steering Control System.

The system shall provide combined control of engines, gears and waterjet steering & reverse bucket.

The Propulsion Control System shall be powered by 24 VDC.

The Propulsion Control System shall be provided, warranted and serviced by the waterjet manufacturer.

b. Propulsion & Steering Control System Operating Modes

The system shall provide four modes of control as follows:

Wheel and throttle lever control.

Joy Stick Control (direction and speed).

Non-Follow-Up back up emergency control of engines, clutch, gear, and jet steering and reverse bucket.

Portable Engine Control to include full steering and throttle range control of waterjets/propulsion engines.

The propulsion & steering system components, software and hardware shall be provided and installed as required to be fully operable in the four modes of control.

The operator control components for:

Wheel and throttle lever control.

Joy Stick Control, and Non-Follow-Up back up emergency control of engines, clutch, gear, and jet steering and reverse bucket.

Shall all be located at the pilot’s station.

The portable engine control device shall be stored in a receptacle at the pilot’s station so that the boat can be operated using this device while seated in the helm chair. The engine control device shall operate anywhere on the deck of the vessel, in the house, or outside the house.

c. Operating Mode Selection

The selector for the operating mode shall be located at the pilot’s station.

The mode selector shall provide acknowledgement indication showing that mode switch has occurred and the selected mode system has taken control from the de-selected mode.

34. Propulsion & Steering Control Power Source System

a. Power Source System

The Contractor shall provide and install a power source system for the propulsion & steering control system.

The power source system shall provide two independent sources of battery power for the propulsion control system.

The system shall provide automatic switchover between power sources in the event of failure of one power source, as well as an indicator to show which source is currently providing the power.

This indicator shall be on the operator’s console. The system shall provide user selectable switching of power sources in addition to the automatic switching capability.

The propulsion control power source system may be provided by either the engine manufacturer or the waterjet manufacturer. The provider of the power source system shall warranty the power source system in addition to the other components provided by the provider, for the same duration as the other components.

b. Common Bonding and Common Potential

Propulsion system malfunctions can arise if controls and sensors operate at different voltages.

To prevent the possibility of propulsion system malfunctions, the power source system shall be configured so that engine, gear and waterjet controls and sensors shall always be powered by the same battery bank source.

Switching between alternative power battery banks shall provide complete switch over of all power to engines, gears, and waterjets.

The power source system shall provide bonding to a common ground point, such that all, control system and control power system components are at the same potential.

c. Propulsion & Steering Control System & Propulsion Control Power Source System On Board Survey

The Contractor shall retain the services of Ockerman Automation Consulting, Inc. (Anacortes WA, (360) 293 0206) to come on board the vessel after completion, to conduct a survey of the propulsion & steering control system, and the propulsion control power source system.

The survey shall be conducted to verify the proper installation of the systems in the following areas:

wiring installation, bonding, signal protection, potential levels, power supply cleanliness signal noise drawing accuracy and completeness (paragraph 35)

The Contractor shall coordinate the survey time with Ockerman Automation, to ensure the vessel is ready at the time of the survey.

The Contractor shall provide a report from Ockerman Associates documenting the proper installation and function of the systems in the areas above, and also documenting the accuracy and completeness of the drawings.

35. Drawings for Propulsion & Steering Control System, and Power Source System

The Contractor shall provide drawings for the propulsion & steering control system, and for the propulsion & steering control power source system.

The drawings shall provide the following:

a. Propulsion & Steering Control:

Propulsion & Steering Control System Diagrammatic Propulsion & Steering Control System Wiring Diagram, (including all terminal blocks, and wiring sizes & types).

Propulsion & Steering Control Block Diagram, showing all components.

b. Propulsion & Steering Control Power Supply System

Power Supply System Diagrammatic Power Supply System Wiring Diagram, (including all terminal blocks, and wiring sizes

& types).

Power Supply System Block Diagram, showing all components.

c. Control System & Power Supply System Interface

System Interface Diagrammatic, showing all components of both systems.

System Interface Wiring Diagram, (including all terminal blocks, and wiring sizes & types).

System Interface Block Diagram, showing all components.

36. DC Lighting:

The DC Lighting System shall consist of red LED dimmable fixtures for night operation.

Fixtures shall be provided as follows:

Deckhouse - 8 fixtures, each individually switched & dimmed.

Head and galley spaces - 2 fixtures each space, one switch & dimmer each space.

All gauges, controls , switches and indicators on the operators console shall be dimmable.

37. Noise:

Deckhouse interior noise levels shall not exceed the following criteria:

Top Speed - 75db, with maximum propulsion engine power and one genset.

Surveying - 72db, with 20% propulsion engine power and one genset.

Dockside - 69db, with no propulsion and one genset.

The Contractor shall provide and install acoustic treatments and engine silencing treatments as required to meet the above noise levels.

The Contractor shall retain an Acoustic Consultant, experienced in marine applications to develop acoustic treatments required to attain the noise levels above.

All acoustic treatments installed shall be suitable for marine use on high speed vessels with high levels of vessel acceleration and vibration.

38. Coatings, Signage & Draft Marks:

a. Coatings

A foul release antifouling coating, equal to Intersleek 900, shall be provided on hulls and foils, up to 6 inches above the full load waterline.

Waterjets shall be provided with manufacturer approved antifouling coatings on their interiors and submerged exteriors. All antifouling shall be black.

For exterior decks (including deckhouse roof), exterior steps, and the diver platforms the following coatings shall be used:

Two-Part Polyurethane shall be applied as a base coat with non-skid garnet additive size #24 aluminum oxide grit. The amount of non-skid additive applied shall not be less than 0.3 lb per square foot. One-Part Polyurethane shall be applied as a top coat. Coatings shall be Teflon Kingston Gray color. All potential tripping hazards shall be top coated in a yellow color.

b. Signage

Corps of Engineers Signage and labeling shall be provided on hulls. The Corps Castle logo shall be aluminum and shall be 3D. The red background for the signage shall be 3M Diamond Grade DG3 Reflective Sheeting Series 4000. One of these signs shall be located on the side of the pilot house top. Name boards shall be provided in close proximity to the Corps Castle 3D logos.

These shall be aluminum backing with 6” black vinyl lettering. In addition, a Corps Castle communication mark shall be painted on the top of the house top roof in the Deck Red color.

This mark shall be at least 5’ x 3.55’.

c. Draft Marks

Draft marks shall be…