Solicitation_for_FBO.pdf
PDF 380 KB Posted
- Attached to
- Oahe Exciter Replacement Federal contract opportunity
- Solicitation number
- W9128F-16-T-0045
About this file
Solicitation
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_9_-_W9128F-16-T-0045.pdf | ||
| Amendment_8_-_W9128F-16-T-0045.pdf | ||
| OAHE_Contractor_Question-8_Feb_2017.pdf | ||
| Additional_Specs.pdf | ||
| FIO_CT_bus_Photos.pdf | ||
| Oahe_Exciters_Reference_Drawings.pdf | ||
| Oahe_Exciter_Contract_Drawings.pdf | ||
| Amendment__7_W9128F-16-T-0045.pdf | ||
| Amendment_6_-_W9128F-16-T-0045.pdf | ||
| Amendment_0005_-_W9128F-16-T-0045_.pdf | ||
| Past_Performance_Questionnaire.pdf | ||
| Amendment_4.-_W9128F-16-T-0045.pdf | ||
| Amendment_3_-_W9128F-16-T-0045.pdf | ||
| Amendment_2_-_W9218F-16-T-0045.pdf | ||
| Amendment_1_-_W9218F-16-T-0045.pdf | ||
| Oahe_Exciters_ref_Dwgs.pdf | ||
| Oahe_Exciter_Specs.pdf | ||
| Oahe_Supply_and_Install_Exciters_Dwgs.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE ADDENDUM
(No Collect Calls)
W9128F-16-T-0045 14-Sep-2016
b. TELEPHONE NUMBER
402-995-2045
8. OFFER DUE DATE/LOCAL TIME
02:00 PM 25 Oct 2016
5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV. 2/2012)
Prescribed by GSA – FAR (48 CFR) 53.212
(TYPE OR PRINT)
(SIGNATURE OF CONTRACTING OFFICER)
ADDENDA ARE
26. TOTAL AWARD AMOUNT (For Gov t. Use Only )
23.
CODE 10. THIS ACQUISITION IS
SUCH ADDRESS IN OFFER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT
BELOW IS CHECKED
TELEPHONE NO.
W9128F9. ISSUED BY
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME
ALEXANDER MUELLER
2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER
(TYPE OR PRINT)
30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER
30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA
0 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.
25. ACCOUNTING AND APPROPRIATION DATA
1. REQUISITION NUMBER
20.
ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.
OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
W59XQG61116584
ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
. YOUR OFFER ON SOLICITATION
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
% FOR:SET ASIDE:UNRESTRICTED ORX
SMALL BUSINESS
WOMEN-OWNED SMALL
BUSINESS (WOSB)
17a.CONTRACTOR/ CODE FACILITY
OFFEROR CODE
U.S. ARMY CORPS OF ENGINEERS, OMAHA DIST
CONTRACTING OFFICE
1616 CAPITOL AVENUE
OMAHA NE 68102-4901
18a. PAYMENT WILL BE MADE BY CODE
RATED ORDER UNDER
DPAS (15 CFR 700)
13a. THIS CONTRACT IS A
13b. RATING
CODE15. DELIVER TO CODE 966704 16. ADMINISTERED BY
12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-
TION UNLESS BLOCK IS
MARKED
SEE SCHEDULE
14. METHOD OF SOLICITATION
RFQ IFB RFPX
US ARMY CORPS OF ENGINEERS-OAHE
PHIL SHEFFIELD
28563 POWERHOUSE ROAD
PIERRE SD 57501-6174
TEL: (605)224-5862 X3005 FAX:
FAX:
TEL: SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
8(A)
HUBZONE SMALL
BUSINESS
ECONOMICALLY DISADVANTAGED
WOMEN-OWNED SMALL BUSINESS
(EDWOSB)
SIZE STANDARD:
1000 Employees
NAICS:
335312
X
OFFER DATED
29. AWARD OF CONTRACT: REF.
DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND
EMAIL:
TEL:
31c. DATE SIGNED
SEE SCHEDULE
SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT
24.22.21.19.
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
(CONTINUED)
PAGE 2 OF82
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
32b. SIGNATURE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
37. CHECK NUMBER
FINALPARTIALCOMPLETE
36. PAYMENT35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER
FINAL
33. SHIP NUMBER
PARTIAL
38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE
42a. RECEIVED BY (Print)
42b. RECEIVED AT (Location)
42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS
STANDARD FORM 1449 (REV. 2/2012) BACK
Prescribed by GSA – FAR (48 CFR) 53.212
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
SEE SCHEDULE
20.
SCHEDULE OF SUPPLIES/ SERVICES
21.
QUANTITY UNIT
22. 23.
UNIT PRICE
24.
AMOUNT
19.
ITEM NO.
W9128F-16-T-0045
Section SF 1449 - CONTINUATION SHEET
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 7 Each Design, Manufacture, Test & Deliver
FFP
Excitation System and Appurtenances FOB: Destination
MILSTRIP: W59XQG61116584
PURCHASE REQUEST NUMBER: W59XQG61116584
NET AMT
0002 7 Each Disassemble and Remove Existing
FFP
Excitation System FOB: Destination
0003 7 Each Install Excitation Systems
FFP
and Appurtenances FOB: Destination
0004 1 Job Mobilization and Demobilization for
FFP
Installation Work FOB: Destination
0005 7 Each Modify Existing Control Panels
FFP
FOB: Destination
0006 7 Each Deliver and Install External Wiring, FFP
Cabling, Conduit and Cable Tray Additions FOB: Destination
0007 1 Job Perform Field Testing
FFP
FOB: Destination
0008 1 Job Wrenches, Tools, and Special Equipment
FFP
FOB: Destination
0009 1 Job Spare Parts
FFP
FOB: Destination
0010 7 Job Commissioning Engineers
FFP
FOB: Destination
0011 7 Job OPTION Collector Ring Refurbishment
FFP
FOB: Destination
0012 7 Job OPTION Collector Ring Replacement
FFP
INSPECTION AND ACCEPTANCE TERMS
Supplies/services will be inspected/accepted at:
CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY
0001 N/A N/A N/A Government 0002 N/A N/A N/A Government 0003 N/A N/A N/A Government 0004 N/A N/A N/A Government 0005 N/A N/A N/A Government 0006 N/A N/A N/A Government 0007 N/A N/A N/A Government 0008 N/A N/A N/A Government 0009 N/A N/A N/A Government 0010 N/A N/A N/A Government 0011 N/A N/A N/A Government 0012 N/A N/A N/A Government
DELIVERY INFORMATION
CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS UIC
0001 540 dys. ADC 7 US ARMY CORPS OF ENGINEERS-OAHE
PHIL SHEFFIELD
28563 POWERHOUSE ROAD
PIERRE SD 57501-6174
(605)224-5862 X3005
966704
0002 540 dys. ADC 7 (SAME AS PREVIOUS LOCATION)
0003 540 dys. ADC 7 (SAME AS PREVIOUS LOCATION)
0004 540 dys. ADC 1 (SAME AS PREVIOUS LOCATION)
0005 540 dys. ADC 7 (SAME AS PREVIOUS LOCATION)
0006 540 dys. ADC 7 (SAME AS PREVIOUS LOCATION)
0007 540 dys. ADC 1 (SAME AS PREVIOUS LOCATION)
0008 540 dys. ADC 1 (SAME AS PREVIOUS LOCATION)
0009 540 dys. ADC 1 (SAME AS PREVIOUS LOCATION)
0010 540 dys. ADC 7 (SAME AS PREVIOUS LOCATION)
0011 540 dys. ADC 7 (SAME AS PREVIOUS LOCATION)
0012 540 dys. ADC 7 (SAME AS PREVIOUS LOCATION)
SOLICITATION INSTRUCTIONS
Antiterrorism (AT)/Operations Security (OPSEC)
This solicitation has AT/OPSEC provisions that were not in prior contracts for similar requiremetns before 2014.
Please reference AT/OPSEC Provisions in this solicitation.
SOLICITATION INSTRUCTIONS:
This solicitation is being advertised based on best value. Please reference FAR 52.212-2 for evaluation criteria and information required to be submitted with your quote.
Please complete and return the following:
1. The Standard Form (SF) 1449 pages where it was necessary to fill in information/price(s) and/or signature.
2. Offeror Representations and Certifications -- Commercial Items (FAR Clause 52.212-3) or verify registration on SAM (see paragraph later in this document); FAR 52.225-18 and DFARS 252.209-7992
3. Please enter your CAGE Code in Block 17a of the SF 1449 within the smaller block next to the word “CODE.” The company name and street address entered on the SF 1449 should match the System for Award Management (SAM) entry for that CAGE Code.
4. Submit a cover letter stating that the proposal/quote complies completely with all terms, conditions, and specifications contained in the solicitation. A proposal/quote that does not comply with all terms, conditions, and specifications in the solicitation will be automatically rejected and not considered for award.
Due date/time:
Return completed solicitation package by the date and time specified in Block 8 of the SF1449. Send your completed quotation package to the attention of Timothy Boyte via email to: Timothy.B.Boyte@usace.army.mil.
Electronic responses are preferred over paper responses.
Please reference Solicitation Number W9128F-16-T-0045 on all correspondence.
Points of Contact (POC):
For contractual questions, contact Timothy Boyte at (402) 995-2589 or Timothy.B.Boyte@usace.army.mil.
INFORMATION PERTAINING TO MANDATORY REGISTRATIONS, CODES, NUMBERS &
REPRESENTATIONS & CERTIFICATIONS:
System for Award Management (SAM):
What is SAM?
The System for Award Management (SAM) is combining federal procurement systems and the Catalog of Federal Domestic Assistance into one new system. This consolidation is being done in phases. The first phase of SAM includes the functionality from the following systems:
* Central Contractor Registry (SAM)
* Federal Agency Registration (FedReg)
* Online Representations and Certifications Application (ORCA)
* Excluded Parties List System (EPLS)
How will SAM benefit me?
The overarching benefits of SAM include streamlined and integrated processes, elimination of data redundancies, and reduced costs while providing improved capability.
SAM registration is required prior to receiving contract award. If you are not currently registered in SAM, refer to the website for information and instructions on how to register. You may link to the SAM website through the aforementioned BPN website or you may go directly to the SAM website at https://www.sam.gov. Clicking on “Help” on the top ribbon of the SAM Home Page will give you access to the following information:
About SAM News User Help Agency Information Interface and Data Access Contact Us External Resources
SAM Service Desk:
URL: http://www.FSD.gov (8am - 8pm Eastern Time) US Calls: 866-606-8220 International Calls: 334-206-7828
DSN: 809-463-3376
Do not delay returning a quote while processing your SAM entry.
Electronic Funds Transfer (EFT):
EFT is a mandatory requirement for the U.S. Army Corps of Engineers. The successful offeror will be required to complete and return EFT forms that will be provided by our agency upon contract award, unless the offeror is currently entered as an active vendor in the Omaha District Corps of Engineers Financial Management System (CEFMS). Offerors with an active vendor entry in the Omaha District CEFMS will be asked to verify the existing EFT information. Please note the CEFMS EFT entry is in addition to the EFT information entered into the offeror’s SAM registration.
NAICS Code:
This solicitation is being advertised under the North American Industrial Classification Systems (NAICS) Code listed in Box 10 on Page 1 of the SF 1449. You must ensure this NAICS Code is incorporated into your current SAM Profile if your company can provide the type of product or service applicable to this NAICS Code. Failure to have this NAICS Code in your current SAM Profile may result in not being considered for award. NAICS Codes may be viewed at the U.S. Census Bureau website at http://www.census.gov/eos/www/naics
Dun and Bradstreet Number (DUNS Number):
A DUNS Number is required for SAM registration. If you do not currently have a DUNS number, you may acquire one by linking to the Dun & Bradstreet (D&B) website at http://fedgov.dnb.com/webform. D&B’s Government Customer Response Center (GCRC) phone number is 866-705-5711.
Dun & Bradstreet (D&B) provides a DUNS Number, a unique nine digit identification number, for each physical location of your business.
DUNS Number assignment is free for all businesses required to register with the US Federal Government for contracts or grants.
If a DUNS Number does not exist for your business location, it can be created within 1 business day via the D&B website.
OFFEROR’S INFORMATION REQUIRED TO PROCESS AN AWARD:
CAGE Code______________________
DUNS Number ___________________
Tax Identification Number (TIN)______________________________
Company Name and Address:
(Also REQUIRED to match SAM Profile and Block 17a on SF 1449!
Point of Contact:
Name_______________________________________
Title________________________________________
Business Phone ______________________________
Cell Phone (if applicable)______________________
E-Mail______________________________________
Is your Company (please circle each line individually):
Small Business concern Yes No Small Disadvantaged Business concern Yes No Veteran-Owned Small Business concern Yes No Service-Disabled Veteran-Owned Small Business concern Yes No Women-owned business concern Yes No Sole Proprietorship Yes No Partnership Yes No Corporation Yes No Registered with SAM Yes No
State and Local Taxes:
The U.S. Army Corps of Engineers is exempt from paying state and local taxes per Title 4 United States Code 104-
107. The U.S. Army Corps of Engineers Tax ID Number is 62-1642142.
Contractors performing services for the U.S. Army Corps of Engineers are not exempt from state and local taxes in transactions with vendors, suppliers or subcontractors.
In the State of South Dakota, there is an excise tax on the total gross receipts of all prime contractors and subcontractors engaged in realty improvement. Contractors shall include the excise tax in its quotation. For information concerning the taxes contact: Sales and Use Tax Division, Capital Lake Plaza, Pierre, South Dakota. Telephone 605-773-3311.
Payments:
Payments will be made after receipt of a proper invoice or receipt of acceptable supplies or services, whichever is later. The contractor is required to include the contract number on all invoices so that receipt and payment for the item or service may be expeditiously processed.
Federal Legal Holidays:
The following Federal legal holidays are observed by this installation:
New Year's Day 1 January Martin Luther King's Birthday Third Monday in January President's Day Third Monday in February Memorial Day Last Monday in May Independence Day 4 July Labor Day First Monday in September Columbus Day Second Monday in October Veterans Day 11 November Thanksgiving Day Fourth Thursday in November
Christmas Day 25 December
If a wage determination applies, the number of holidays specified on it has priority over this clause.
Insurance Required (Local Provision):
In accordance with FAR 28.307-2, “Liability,” the contractor shall procure the following minimum insurance:
Type Amount Workman’s Compensation and Employer’s Liability Insurance $100,000 General Liability Insurance $1,000,000 per occurrence
And, when automobiles are used in connection with performing the contract:
Type Amount Automobile Liability Insurance $200,000 per person Bodily Injury $500,000 per occurrence Property Damage $ 20,000 per occurrence
And, when aircraft is used in connection with performing the contract:
Type Amount Aircraft Public and Passenger Liability Insurance $200,000 per person Bodily Injury (other than passenger injury) $500,000 per occurrence Property Damage $200,000 per occurrence Passenger Liability Bodily Injury $200,000 multiplied by the number of seats or passengers, whichever is greater
And, when contract performance involves use of vessels, the Contracting Officer shall require, as determined by the agency, vessel collision liability and protection and indemnity insurance. The contractor is responsible for contacting the state for compliance with its workman’s compensation laws
52.212-1 AND 52.212-2 ADDENDUM
52.212-1 and 5212-2 ADDENDUM
OFFER INSTRUCTIONS,
SUBMISSION REQUIREMENTS AND EVALUATION
1. WHO MAY SUBMIT
This solicitation is for Unrestricted competition.
All proposers, including joint ventures, must be registered in the System for Award Management (SAM.gov). See paragraph 15.6 Joint Ventures/SAM Registration.
There will be no public opening. All offers submitted will become, upon receipt, the property of the U.S.
Government and will not be returned. After evaluation of offers, the original will be retained for the official contract file. Extra copies of the awardees’ offer will be submitted to the Field and Area Offices in support of their contract administration functions. Any extra copies of the offers deemed unnecessary by the government will be destroyed.
2. GENERAL REQUIREMENTS
In order to effectively and equitably evaluate all offers, the Contracting Officer must receive information sufficiently detailed to clearly indicate compliance with the offer submission requirements.
3. SIZE OF PRINTED MATTER SUBMISSIONS
All written portions (other than an organization chart (if provided)) shall be in 8-1/2" x 11" format.
4. WHERE TO SUBMIT
Offerors shall submit their offer packages to the USACE Contracting Activity at the address shown in Block 9 of Standard Form 1449.
5. SUBMISSION DEADLINE
Offers shall be received by the USACE Contracting Activity no later than the time and date specified in Block 8 of Standard Form 1449.
Due to heightened security at Government installations, those Offerors who have their offers hand-delivered shall contact Timothy B. Boyte, Contract Specialist, at (402) 995-2589 prior to delivering to:
U.S. Army Corps of Engineers, Omaha District ATTN: CENWO-CT-C (Boyte) 1616 Capitol Avenue Omaha, NE 68102-4901
On the date specified and for the thirty minutes prior to the time specified on the Standard Form SF 1449, Block 8, a Contracting Representative will be in the lobby to accept offers. Official time will be established by the clock located in the area where offers are received.
6. OFFERS
Offerors shall submit an offer that meets or exceeds the minimum requirements of these specifications through the replacement, modification or refurbishment of components identified in this solicitation.
7. EVALUATION OF OFFERS
a. All offers and documentation which have been properly submitted will be evaluated. Offers will be evaluated on the basis of the factors stated in the solicitation to select the responsible offeror whose offer is most advantageous to the Government. Because of the number of offers anticipated, uniformity of all offers is essential to assure fair and accurate evaluation. All offers must comply with the instructions in the solicitation. Offers that do not generally conform to the RFP requirements may be considered to have a deficiency, i.e. a defect that cannot be remedied by exchanges and/or permitted offer revisions. If an offer is suspected of having a deficiency, it will be brought to the immediate attention of the appropriate authority who will determine if there is a deficiency. If the determination is made that a deficiency exists, the offer will not be evaluated further and will be eliminated from further consideration. The affected offeror shall be promptly notified of the decision. Properly conforming offers will be forwarded to the Technical Evaluation Board for evaluation. If, after award, the key personnel or sub-contractors identified in the offer are replaced, replacement personnel or sub-contractors with similar skills and experience equal to those presented in the offer shall be presented to the Contracting Officer for approval. The Contractor shall obtain the Contracting Officer’s written consent before making any substitutions for these designated personnel or sub-contractors.
b. Information obtained from Government sources and databases or other points of contact provided by the offeror may affect the past performance evaluation rating given.
c. Evaluations will be conducted in accordance with the Tradeoff Process, FAR 15.101-1. Factors 1, 3 and 4 will be rated using a color/adjectival methodology with a narrative assessment, Factor 2 will be evaluated in accordance with paragraph 7(f), and Factor 5 (Price) will be evaluated after consensus scoring Factors 1-4. Offer evaluation is an assessment of the offer and the offeror's ability to perform the resultant contract successfully. Offers will be evaluated to determine ratings supported by narratives, and to identify strengths, weaknesses, and deficiencies of the proposed approach in each offer.
d. Evaluation Definitions.
Strength. A substantive aspect, attribute, or specific item in the offer that exceeds the solicitation requirements and enhances the probability of successful contract performance.
Weakness. A flaw in the offer that increases the risk of unsuccessful contract performance. A significant weakness in the offer is a flaw that appreciably increases the risk.
Deficiency. A material failure of an offer to meet a Government requirement or a combination of significant weaknesses in an offer that increases the risk of unsuccessful contract performance to an unacceptable level.
Clarification. Clarifications are limited exchanges between the Government and Offerors that may occur when award without discussions is contemplated. If award without discussions is anticipated, Offerors may be given the opportunity to clarify certain aspects of their offers or to resolve minor or clerical errors.
Communications. Communications are exchanges between the Government and Offerors after receipt of offers, leading to establishment of the competitive range.
Discussions. Discussions are negotiations conducted in a competitive acquisition and take place after establishment of the competitive range. Discussions are tailored to each Offeror’s offer, and shall be conducted by the Contracting Officer with each Offeror within the competitive range.
e. Combined Technical/Risk Rating. The application of a scale of colors and adjectival description will be used in conjunction with narrative to denote the degree to which the offer has met the standard for a non-cost factor.
Ratings will be applied at the factor and subfactor level (if any). If, at any subfactor level, an offeror’s offer is evaluated as not meeting a minimum requirement (that is, below the rating of Marginal), this fact must be included in the rating and narrative assessment at that level and at the factor. Therefore, an Unacceptable rating at any subfactor level may be carried to the factor level. The ratings provided in table below will be used to evaluate Factors 1, 3, and 4.
Combined Technical/Risk Ratings
Color Rating Description Blue Outstanding Offer meets requirements and indicates an exceptional approach and understanding of the requirements. Strengths far outweigh any weaknesses. Risk of unsuccessful performance is very low.
Purple Good Offer meets requirements and indicates a thorough approach and understanding of the requirements.
Offer contains strengths which outweigh any weaknesses. Risk of unsuccessful performance is low.
Green Acceptable Offer meets requirements and indicates an adequate approach and understanding of the requirements.
Strengths and weaknesses are offsetting or will have little or no impact on contract performance.
Risk of unsuccessful performance is no worse than moderate.
Yellow Marginal Offer does not clearly meet requirements and has not demonstrated an adequate approach and understanding of the requirements. The offer has one or more weaknesses which are not offset by strengths. Risk of unsuccessful performance is high.
Red Unacceptable Offer does not meet requirements and contains one or more deficiencies. Offer is unawardable.
f. Past Performance Evaluation. The past performance evaluation results in an assessment of the Offeror’s probability of meeting the solicitation requirements. There are two aspects of the past performance evaluation. The first aspect is relevancy. The past performance evaluation considers each Offeror's demonstrated recent and relevant record of performance in supplying products and services that meet the contract’s requirements. The Offeror’s past performance will be evaluated to determine how relevant a recent effort accomplished by the Offeror is to the effort to be acquired through the source selection. Consideration shall be given to those aspects of an Offeror’s contract history that would give the greatest ability to measure whether the Offeror will satisfy the current procurement. Common aspects of relevancy include similarity of service/support, complexity; dollar value, contract type, and degree of subcontract/teaming. There are four levels of relevancy as shown below. With respect to relevancy, more relevant past performance will typically be a stronger predictor of future success and have more influence on the past performance confidence assessment than past performance of lesser relevance.
Relevancy Rating
Rating Definition Very Relevant Present/past performance effort involved essentially the same scope and magnitude of effort and complexities this solicitation requires.
Relevant Present/past performance effort involved similar scope and magnitude of effort and complexities this solicitation requires.
Somewhat Relevant Present/past performance effort involved some of the scope and magnitude of effort and complexities this solicitation requires.
Not Relevant Present/past performance effort involved little or none of the scope and magnitude of effort and complexities this solicitation requires.
The second aspect of the past performance evaluation is to determine how well the contractor performed on the contracts and give a performance confidence assessment. The past performance evaluation process gathers information from customers on how well the Offeror performed those past contracts. Past performance information may be provided by the Offeror, as solicited. Past performance information may also be obtained from questionnaires. Past performance information shall be obtained from any other sources available to the Government, to include, but not limited to the Contractors Performance Assessment Reporting System (CPARS), the Past Performance Information Retrieval System (PPIRS), Federal Awardee Performance and Integrity Information System (FAPIIS), Electronic Subcontract Reporting System (eSRS), or other databases; interviews with Program Managers, Contracting Officers, and Fee Determining Officials; and the Defense Contract Management Agency. In conducting a performance confidence assessment, each Offeror shall be assigned one of the ratings as indicated below.
Confidence Rating
Rating Description Substantial Confidence Based on the Offeror’s recent/relevant performance record, the
Government has a high expectation that the Offeror will successfully perform the required effort.
Satisfactory Confidence Based on the Offeror’s recent/relevant performance record, the Government has a reasonable expectation that the Offeror will successfully perform the required effort.
Limited Confidence Based on the Offeror’s recent/relevant performance record, the Government has a low expectation that the Offeror will successfully perform the required effort.
No Confidence Based on the Offeror’s recent/relevant performance record, the Government has no expectation that the Offeror will be able to successfully perform the required effort.
Unknown Confidence (Neutral)
No recent/relevant performance record is available or the Offeror’s performance record is so sparse that no meaningful confidence assessment rating can be reasonably assigned.
Note that ratings will be applied at the factor and subfactor level (on an Individual and Consensus basis; see discussion of Individual and Consensus rating procedures in paragraph 10 below). The Factor 1, 3 and 4 rating will be expressed as: FACTOR-LEVEL COMBINED TECHNICAL/RISK RATING of _____(insert color-word adjectival rating)____. Factor 2 (Past Performance) receives a “Past Performance Relevancy and Past Performance Confidence Assessment Rating.” Factor 5 will not be rated or scored but will be evaluated for fairness and reasonableness through the use of price analysis.
For Factor 2, Past Performance, an Unknown Confidence (Neutral) rating will be awarded when no past performance records are otherwise unavailable. Per Federal Acquisition Regulation (FAR) 15.305(a)(2)(iv), “In the case of an Offeror without a record of relevant past performance or for whom information on past performance is not available, the Offeror may not be evaluated either favorably or unfavorably on past performance."
8. EVALUATION FACTORS FOR AWARD
The areas to be evaluated include Evaluation Factors which will be evaluated based on the adjectival method of evaluation. The requirements specified in the solicitation are considered to be minimum requirements. A more favorable evaluation rating may be given for exceeding the minimum requirements. Note: Factors 1-3 are equal in importance to each other, and Factor 4 is significantly less important than Factors 1, 2, or 3. Factor 5 (Price) is significantly less important to the combined Factors 1-4.
Binder No. 1
Factor 1 –Experience/Schedule
Factor 2 – Past Performance
Factor 3 –Technical Data
Factor 4 - Utilization of Small Business Concerns (Large Businesses Only)
Binder No. 2 Factor 5 – Price (significantly less important to the combined factor elements in Binder 1)
Note: An “Unacceptable” evaluation rating for any factor, or combination of different factors, shall cause the overall offer to be evaluated as “Unacceptable”. Price will be evaluated in accordance the requirements listed in paragraph 14.2, Evaluation of Price.
9. OFFER REQUIREMENTS AND SUBMISSION FORMAT
Offerors shall submit the original and four (4) copies of their Binder 1 (containing Factors1-4). Only the original of Binder 2 – Price, shall be submitted (copies of this binder are not required). Binder 1 shall consist of a 3-ring binder with Factors, with tabs (dividers) separating Tabs 1 – 4. Binder 2 shall be a separate binder. All offerors are required to submit an electronic copy of Binder 1 and 2 on a CD. The binders shall be divided as follows.
Binder No. 1
Tab 1 –Experience/ Schedule Tab 2 – Past Performance Tab 3 – Technical Data Tab 4 – Utilization of Small Business Concerns (Large Business Only)
Offerors shall submit only the original of their price offer, along with the other information requested below, in a 3-ring binder designated as “Binder No. 2”.
Binder No. 2 Tab 1 - Cover Letter Tab 2 – Completed SF 1449, Solicitation/Contract/Order For Commercial Items Tab 3 - Representations, Certifications and Other Statements of Offerors Tab 4 - Pre-Award Survey Information, Small Business Information, and Evidence of Bondability
Both Binder 1 and Binder 2 shall contain all submission requirement information. Offer clarity, organization (as defined in this solicitation) and cross reference is mandatory. No material (information not part of the offer) shall be incorporated by reference.
Binder 2 shall include a cover letter stating that the offer complies completely with all terms, conditions, and specifications contained in the solicitation. An offer that does not comply with all terms, conditions, and specifications in the solicitation will be automatically rejected and not considered for award. Furthermore, Binder 2 shall include evidence of the contractor’s ability to meet the bonding requirements. Any proposers that do not provide evidence of bondability shall not be eligible for award.
Factor/Sub
Factor Location Description Relative Importance
FACTOR 1
Binder 1, TAB 1
Experience/ Schedule Equivalent importance to Factors 2 & 3
FACTOR 2
Binder 1. TAB 2 Past Performance
Factors 1 & 3
FACTOR 3
Binder 1. TAB 3 Technical Data
Factors 1 & 2
FACTOR 4
Binder 1. TAB 4 Utilization of Small Business Concerns (Large Business Only)
Significantly less important than Factors 1, 2 & 3
FACTOR 5
Binder 2. TAB 2 Price Significantly less important than the combined Factors of 1thru 4
10. FACTOR 1 – EXPERIENCE/SCHEDULE
In this factor, the contractor shall submit information on company experience, supervisor(s) experience, commissioning engineer’s experience, and the proposed project schedule.
10.1 Submission Requirements
The offeror shall submit up to five (5) examples of excitation projects which best illustrate the experience of the contractor on projects of similar function and scope. The Offeror shall identify themselves as regularly engaged in the fabrication, manufacture, installation and commissioning of excitation systems for hydroelectric generators of 10,000 kVA or larger for a period of time of approximately ten (10) years or greater or identify partnering or subcontracting agreements with firms other than the Offeror providing this experience. The Offeror shall provide a list of at least approximately three (3) excitation installation contracts held approximately within the last five (5) years on the eastern or western grids. The projects selected should represent work similar to that proposed, whereby they have removed, fabricated, manufactured, installed and commissioned a complete excitation system for generators of similar capacities.
Project examples should be completed (or are substantially complete at the time of this offer), have the same or similar system as the proposed to be supplied under this solicitation, be of separate design and/or location (i.e. not three (3) contracts in one powerhouse). Project examples shall identify the firms providing this experience and their relationship to the Offeror during said project, e.g. prime contractor (same as Offeror), subcontractor, material supplier, not associated with the Offeror, etc. Project example shall provide a short narrative discussing the project and shall include: Name and location of the plant, rating of the equipment, contract award amount (estimate or actual); project start date and completion date (if finished). All examples should include the name, address, and telephone number of a representative of the customer. The Government may choose to contact the customer representative to verify all major and minor problems resulting from the operation of the winding have been corrected.
The Offeror shall provide a resume on the installation supervisor (or supervisors) who will work on this project.
Information provided should include education, experience, professional certification/licenses, applicable technical training, and references. The Government may choose to contact the references to verify supervisory experience and customer satisfaction. Provided documentation demonstrates that the installation supervisor has been engaged in installation and testing of similar excitation systems on hydroelectric generators at a minimum for a period of approximately three (3) years or greater. Resumes shall include a list of projects in which the individual has filled a role of installation supervisor for removal, installation and testing of excitation systems on hydroelectric generators of 10 MVA and larger for approximately the last three (3) years and longer. Resumes should be complete and demonstrate the supervisors experience and qualifications. If the offer identifies multiple possible candidates for site supervisor, the evaluation will be based on the individual considered by the source selection team to be the least qualified of the candidates.
The Offeror shall provide a resume on the commissioning engineer(s) who will work on this project. Information provided should include education, experience, professional certification/licenses, applicable technical training, and references. The Government may choose to contact the references to verify supervisory experience and customer satisfaction. Provided documentation demonstrates that the commissioning engineer has been engaged in commissioning and testing of similar excitation systems on hydroelectric generators for a period of three (3) years or greater. Resumes shall include a list of projects in which the individual has filled a role of programming, commissioning and testing of excitation systems and PSS on hydroelectric generators of 10 MVA and larger for approximately the last three (3) years and longer. Resumes should be complete and demonstrate the engineer’s relevant experience and qualifications. If multiple people are to be used then their roles are to be clearly defined. For example there may be a senior engineer excitation engineer, a PSS engineer etc. If the offer identifies multiple possible candidates for commissioning engineer, the evaluation will be based on the individual considered by the source selection team to be the least qualified of the candidates. If it is the intent to use multiple people in different roles then this must be clearly defined.
The Offeror shall provide an outline schedule for fabrication, installation and commissioning work required by this contract. The schedule should be prepared in the form of major milestones and days to completion including design (inherent to fabrication) and design reviews. Milestones shall include (by generator where applicable) transformer and excitation design (inherent to fabrication), transformer and excitation manufacturing and delivery completion, site installation, unit outage time, testing and commissioning. The proposed project schedule should clearly indicate the total number of calendar days from Notice to Proceed proposed for contract performance. The Offeror shall provide supporting documentation to substantiate project schedule claims (e.g. similar previous work accomplished in same time frame). The Offeror’s manufacturing and testing facilities will be considered in determining whether the Offeror is qualified to perform the work. The Offeror shall declare and demonstrate that they have the necessary capital and own, or control by firm option, or able to procure the necessary plant to commerce the work according to project schedule and have the capability to perform multiple, simultaneous projects.
10.2 Evaluation
The following information will be used in consideration for favorable ratings of offers:
Greater amounts of recent and relevant experience to the scope of work in this solicitation will receive favorable rating.
Years of manufacturing, testing, commissioning and installing exciters of similar type and size will receive favorable ratings. The number of excitation contracts held within the last five (5) years, and contracts on the Eastern or Western grids will receive favorable ratings. Number of projects worked on in recent years as installation supervisor will be considered. Consideration will be given to the commissioning engineer’s areas of expertise and their experience in solving problems associated therewith. Experience with US Army Corps or the Bureau of Reclamation will receive favorable ratings. The areas of expertise and experience the supervisor has in solving problems associated therewith will be considered. Aggressive but realistic schedules demonstrating a shorter completion time than the maximum allowable and minimized outage times receive favorable ratings. Schedules that replace exciters in an order and/or plan that is favorable to plant operations and/or plant stability will receive favorable ratings. Schedules and outages that are not realistic or create problems will receive less favorable ratings. All the information required for the offer must be submitted and the lack of requested information or an area of weakness may result in less than favorable ratings.
11. FACTOR 2 –PAST PERFORMANCE
11.1 Submission Requirements
The Offeror shall submit at a minimum description of five (5) excitation design, supply and installation contracts for generators performed as a prime contractor in recent years. The Offeror shall complete this information on the attached Past Performance Information, and include in Volume I for Past Performance. The Offeror shall complete Part I of the attached Contractor Performance Questionnaire, and forward to the five (5) references and have them returned as specified on the form. The references used for Past Performance must be among those listed in Factor 1- Experience/Schedule
The following information is required for each example:
a. Customer organization or company name, primary point of contact (POC), position of POC, and customer address and phone number.
b. Contract number, if applicable
c. Powerhouse name and location (state or country)
d. Date contract and/or work began
e. Date item of equipment was delivered and installation was completed (per definition of “completed” above).
f. Indicate if prime or subcontractor on project
g. Type of exciter that was installed
h. Number of units installed
i. A customer provided narrative, description, or rating of how the Offeror performed on performance indicators, including, but not limited to:
(1) Site Workmanship –
(a) Did the work performed by the Offeror meet, exceed, or fail to meet the Customer’s expectations and specifications?
(b) Was rework required? If rework was required, were issues remedied, or was additional rework required? Were punch list items addressed quickly and completely?
(2) Customer Satisfaction –
(a) Was the Customer satisfied with the overall work provided by the Offeror? Would you choose to do business with the Offeror again if given the choice?
(b) Were there any specific actions that the Offeror performed that made the Customer more than satisfied or less than satisfied with the work performed? If so, what were the specific actions?
(c) Was the Offeror responsive to the Customer’s needs?
(d) Was there any instance of conflict between the Customer and the Offeror? How was the conflict resolved?
(3) Did the Offeror clearly communicate with the Customer about the ongoing status of the contract?
Schedule –
(a) Did the Offeror meet all major milestones and delivery dates?
(b) If a delivery date or milestone was missed, how did the Offeror respond and recover? Did the
Offeror communicate that the milestone or delivery date in advance of missing the milestone or delivery date?
(4) Did the Offeror stay within set price of the contract? (Budget)
11.2. Evaluation
The Government seeks a contractor who maintains a strong commitment to customer satisfaction and superior performance. It is the Offeror’s responsibility to affirmatively document these qualities in the technical offer. In doing so, be mindful that “past performance” and “past experience” are not identical. Past experience measures what the Offeror has done and how many times, or for how long, they have done it. Past performance, however, measures how well the Offeror performed.
Offers will be rated on the past performance indicators of site workmanship, customer satisfaction, schedule, and budget. A good offer would demonstrate that the Offeror receives consistent satisfactory or better ratings across all of the above indicators. Higher ratings will be assigned for those offers that demonstrate superior past performance with work that is relevant in scope and size to this solicitation.
Past performance will be evaluated within the scope of assembling, factory testing, delivery, commissioning, and installing activities of generator excitation systems. The Government may consider Government evaluation data bases for additional past performance information which may be rated.
The offer will be rated for past performance of the prime contractor. Past performance will be rated on the basis of returned Contractor Performance Questionnaires from previous customers. Greater levels of customer satisfaction in the following areas will receive a better rating. Past performance questionnaires from projects in recent years and/or similar type exciters will receive higher consideration (i.e. last five years):
(a) Site Workmanship
(b) Customer Satisfaction
(c) Schedule
(d) Budget
Since the Government may not necessarily interview all the sources provided by the Offerors, it is incumbent upon the Offerors to explain the relevance of the data provided. The Government does not assume the duty to search for data to cure problems it finds in the offer. The burden of providing thorough and complete past performance information remains with the Offerors.
In addition the information submitted by the Offeror, the Government may consider other sources for past performance information including, but not limited to the Contractors Performance Assessment Reporting System (CPARS), the Past Performance Information Retrieval System (PPIRS), Federal Awardee Performance and Integrity Information System (FAPIIS), Electronic Subcontract Reporting System (eSRS), or other databases; interviews with Program Managers, Contracting Officers, Fee Determining Officials; and the Defense Contract Management Agency and personal knowledge.
12. FACTOR 3 - TECHNICAL DATA
In this factor drawings, sketches, processes, and descriptive literature shall be submitted on the products be proposed and on the maintainability of the proposed product. Submit the information as described below.
12.1 Submission Requirements
Sketches or drawings shall be submitted on 8 1/2" x 11" pages or 11"x17" pages folded to fit into 8 1/2" x 11" so that they may be viewed without removal from the three-ring binder. Sketches or drawings shall include as a minimum:
(1) A plan of the excitation system showing its arrangement in the powerhouse, including outline dimensions and dimensions to fixed powerhouse equipment or structures. Clearly demonstrate equipment location and how it will be installed, interconnected and connected to plant structures.
(2) An elevation or plan sketch identifying the contents of each cubicle within the excitation cabinet.
"Descriptive Literature" means information (e.g., cuts, illustrations, drawings, and brochures) that is submitted as part of a bid. Descriptive literature is required to establish, for the purpose of evaluation and award, details of the excitation system offered that are specified elsewhere in the solicitation and pertain to significant elements. Information not related to the major excitation system to be supplied will not be used for evaluating the offer. Where cut-sheets are provided with multiple models, the proposed model number or information shall be circled with all unnecessary models crossed out.
As a minimum, the information below shall be contained in the descriptive literature:
(1) Salient Design Information
(a) Nominal field voltage
(b) No-load ceiling voltage
(c) PPT Specifications (kW, voltage, sound dB, manufacture and any other relevant info)
(d) Provide basis/calculations for PPT rating
(d) Expected maximum DC field current (Amperes)
(e) DC field lead ampacity
(2) Major Components
(a) AC Rectifier supply breaker ratings
(b) Bridge assembly ratings
(c) Identify redundant components (i.e. redundant bridges, controls etc.)
(c) Non-load break disconnect ratings
(3) Methods of assembly, construction, operation and certification/performance (a). A complete description of the HMI, including operation and interfacing.
(b). Cabinet construction, materials, access etc (c). Provide functional block diagram/information which demonstrates that the provided excitation system performs according to the High Initial Response requirements of IEEE 421.1. Additionally provide information on the exciter algorithm model and information on what criteria in IEEE 421.5 that it meets.
(d). Description of Excitation and PSS operation and certification of type-testing for use on the North American grid and demonstration of successful operation on either the Eastern or Western grids.
Certification shall be performed by an independent 3rd party and an official letter signed by the 3rd party describing the compliance and certifying the type testing shall be submitted with the certifiers contact information.
(3) Maintainability The offeror shall provide photos or drawings to demonstrate maintenance accessibility, a write-up of self- diagnostic capabilities, and catalog cuts describing the communication interface of the proposed exciter. The offeror shall submit a series of screen shots or sequential drawings equivalent to displayed information to demonstrate the user-definable parameters which can be changed through the HMI mounted on the excitation cubicle.
12.1.2 Evaluation
The following information will be used in consideration for favorable ratings of offers: Favorable ratings will be given to Offerors who provide complete and well thought-out drawings, which indicate a sound product design and solid understanding of the contract requirements. Noted betterments will receive favorable ratings. Offerors should clearly identify all items considered to be betterments. For each betterment, offerors should explain why the proposed item was considered to be a betterment and what benefit it provides to the Government. Finally, the offerors should quantify the value of each betterment. Equipment with footprints that fit or take up less space than required by the specs will receive favorable ratings. Footprints that exceed the space allowed may either receive less than favorable ratings or deemed deficient. Offers and plans that demonstrate a solid understanding and consideration of the power plants needs and contract requirements will receive favorable ratings. Additionally, sound product designs in excitation and PSS systems and sound operation on the North American grid will be examined. Information demonstrating a solidly built-proven PSS and exciter system/ algorithm will receive favorable ratings. Type testing information showing a robust high level of performance will receive favorable ratings. Technical information which clearly defines the capabilities, performance characteristics and ratings for the equipment is desired and equipment which exceeds requirements and is solidly built will receive favorable ratings. Favorable ratings will be given to Offerors who provide complete and thought-out maintenance requirements and highly useful troubleshooting tools. Additionally ease of access and user-friendly maintenance features will be considered. All the information required for the offer must be submitted and the lack of requested information or an area of weakness may result in less than favorable ratings.
13. FACTOR 4 – UTILIZATION OF SMALL BUSINESS CONCERNS (Large Business Only)
13.1 Submission Requirements
In Factor 4, the Offeror should either: 1) Identify itself as a small business under the NAICS classification and size standard, or 2) If a large business, submit the required information listed below:
(a) Definitions:
(1) Small Business Concerns. For the purpose of this section, small business concerns refer to Small Business, Small Disadvantaged Business, Women-Owned Small Business, HUBZone Small Business, Service Disabled Veteran Owned Small Businesses and Historically Black College and University and Minority Institutions.
(2) Prime Contractor. For the purpose of this section, a prime contractor refers to both large and small contractors.
(3) Offeror: For the purpose of this section, Offeror refers to both large and small contractors.
(4) Floor: "Floor" is the term the U.S. Army Corps of Engineers uses to replace goal.
This is the start of the file's text. The full file is on GovTribe.