Am_0004.pdf

PDF 622 KB Posted

Attached to
Design and Construct 144 Person Domitory Complex Federal contract opportunity
Solicitation number
W9128F-16-R-0076
Issued by
Department of the Army Corps of Engineers Engineering District Omaha

About this file

Amendment 0004

View the file

Other files for this federal contract opportunity

Other files attached to Design and Construct 144 Person Domitory Complex, newest first.
File Type Posted
CAD_BIM_Files-01to04plus.zip ZIP file
CAD_BIM_Files-06to20.zip ZIP file
Am_0004-Drawing.pdf PDF
05_Civil-Part1of2.zip ZIP file
05_Civil-Part2of2.zip ZIP file
KO_Am_0003_(002).pdf PDF
Am_0002.pdf PDF
Am_0001-Drawings.pdf PDF
KO_Am_0001.pdf PDF
W9128F-16-R-0076-Specs.pdf PDF
W9128F-16-R-0076-PlansVol.2.PDF PDF
W9128F-16-R-0076-PlansVol.1.PDF PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICAITON NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicble)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICIATION NO.

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a)By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPIRATION DATA (If required)

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc. ) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION ( Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

Amendment No. 0004 6-OCT-2016

U.S ARMY CORPS OF ENGINEERS, OMAHA DISTRICT

CONTRACTING OFFICE

1616 CAPITOL AVE.

OMAHA, NE 68102-4901

See Item 6

W9128F-16-R-0076

8-SEP-2016

FY16 DORMITORY (FXBM063002)

ELLSWORTH AIR FORCE BASE, SOUTH DAKOTA

See attached documentation for content of the amendment revisions

Date for receipt of Proposals is 19 OCT 2016 at 1400 hours

Government Point of Contact: Dawn Barnett (402) 995-2091

6-OCT-2016

Am #0004 - 2 (Continuation SF 30)

DEPARTMENT OF THE ARMY

Omaha District, Corps of Engineers 1616 Capitol Avenue Omaha, Nebraska 68102-4901

:NOTICE: Failure to acknowledge : Solicitation No. W9128F 16 R 0076 :all amendments may cause rejec- :

:tion of the offer. See FAR : Date of Issue: 8 SEP 2016 :52.215-1 of Section 00 21 01 : NEW Date of Receiving Proposals:

19 OCT 2016

Amendment No. 0004

6 OCT 2016

SUBJECT: Amendment No. 0004 to Request for Proposal Solicitation Package for Construction of

FY16 DORMITORY AT ELLSWORTH AIR FORCE BASE, SOUTH DAKOTA

Solicitation No. W9128F 16 R 0076

TO: Prospective Offerors and Others Concerned

1. The specifications and drawings for subject project are hereby modified as follows (revise all specification indices, attachment lists, and drawing indices accordingly).

a. Specifications (New and/or Revised and Reissued). Delete and substitute or add specification pages or sections as noted below. The substituted pages or sections are revised and reissued with this amendment.

For convenience, on the revised specification pages, changed language has been identified by highlighting. (All portions of reissued specification pages shall apply whether or not changes thereon have been indicated by highlighting.)

Pages or Sections Deleted Pages or Sections Substituted or Added 00 10 00 00 10 00 01 82 00 01 82 00 01 86 13 01 86 13

b. Drawings (Reissued). The following drawings are revised with latest revision date of 03 OCT 2016, and reissued with this amendment.

(1) Sheet EL85CU101, WATER AND SANITARY SEWER PLAN

2. This amendment is a part of the proposing papers and its receipt shall be acknowledged on the new Standard Form 1442. All other conditions and requirements of the request for proposal remain unchanged. If the proposals have been mailed prior to receiving this amendment, you will notify the office where proposals are received, in the specified manner, immediately of its receipt and of any changes in your proposal occasioned thereby.

a. Hand-Carried Proposals shall be delivered to the U.S. Army Corps of Engineers, Omaha District, Contracting Division, 1616 Capitol Avenue, Omaha, Nebraska 68102-4901.

b. Mailed Proposals shall be addressed as noted in Item 8 on

Am #0004 - 3 (Continuation SF 30)

Page 00 10 00-1 of Standard Form 1442.

3. Offers will be received until 2:00 p.m., local time at place of receiving proposals, 19 OCT 2016.

Attachments:

Specification pages listed in 1.a. above Drawing listed in 1.b. above Bridging Documents CAD/BIM files, provided under separate cover (Disclaimer:

The files contained herein were used to compile bridging documents for the subject RFP. The subject files are being provided by request for review by prospective bidders. Files are provided in either .dgn, .dwg, or .RVT format, depending upon the nature of the work communicated.

Please note that the subject files are provided for information only and the Government does not warrant consistency or accuracy of the files in relation to the electronic .PDF files that serve as the basis for bidding the work. The files developed for the RFP were not developed or coordinated in compliance with the BIM development requirements listed in the RFP. Use of the concept model shall not limit compliance with BIM or As-Built requirements in this contract. Utilization of these files shall not limit compliance with any portions or requirements of the

RFP.)

U.S. Army Corps of Engineers, Omaha District 1616 Capitol Avenue Omaha, Nebraska 68102-4901

6 OCT 2016

jlb/2099

00 10 00 - 1

SOLICITATION, OFFER

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

W9128F-16-R-0076

2. TYPE OF SOLICITATION

SEALED BID (IFB)

NEGOTIATED (RFP)

3. DATE ISSUED

8 SEP 2016

PAGES OF PAGES

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO. 5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

7. ISSUED BY CODE CT 8. ADDRESS OFFER TO

U.S.ARMY CORPS OF ENGINEERS, OMAHA

Contracting Division (CENWO-CT) 1616 Capitol Ave Omaha, Nebraska 68102-4901

U.S.ARMY CORPS OF ENGINEERS, OMAHA

Attn: CONTRACTING DIVISION (CENWO-CT) 1616 Capitol Ave Omaha, Nebraska 68102-4901

9. FOR INFORMATION

CALL:

A. NAME

Dawn Barnett

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

(402) 995-2091

SOLICITATION

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS (Title, identifying no., date):

The offeror hereby agrees to do all work described in the documents entitled:

FY16 DORMITORY (FXBM063002)

ELLSWORTH AFB, SOUTH DAKOTA

RETURN WITH OFFER: INFORMATION REQUIRED BY SECTION 00 10 00 (SF1442), SUBMISSION REQUIREMENTS PER FAR PROVISION 52.215-20(b), AND

SECTION 00 45 00.

THIS SOLICITATION IS RESTRICTED TO SMALL BUSINESS PARTICIPATION ONLY.

11. The Contractor shall begin performance within 10 calendar days and complete it within 730 calendar days after receiving award, notice to proceed. This performance period is mandatory, negotiable.

12A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

YES NO

12B. CALENDAR DAYS

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and 0 copies to perform the work required are due at the place specified in Item 8 by 1400 (hour) local time 19 OCT 2016. If this is a sealed bid solicitation, offers must be publicly opened at that time. Sealed envelopes containing offers shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee is is not required.

C. All offers are subject to the (1) work requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than 60 calendar days for Government acceptance after the date offers are due will not be considered and will be rejected.

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442(REV. 4-85)

Prescribed by GSA FAR(48 CFR) 53.236-1(e)

Am_0004

00 10 00 - 2

14. NAME AND ADDRESS OF OFFEROR (Include ZIP Code) 15. TELEPHONE NO. (Include area code)

DUNS Number:

16. REMITTANCE ADDRESS (Include only if different than Item 14)

CODE FACILITY CODE

17. The offeror agrees to perform the work required at the prices specified below in strict accordance with the terms of this solicitation, if this offer is accepted by the Government in writing within 60 calendar days after the date offers are due.

AMOUNTS

SEE ATTACHED CLIN PRICING SCHEDULE

Contractor’s Fax No. CAGE CODE Contractor’s E-Mail address

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation - give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN OFFER

(Type or print)

20B. SIGNATURE 20C. OFFER DATE

AWARD (To be completed by Government)

21. ITEMS ACCEPTED:

22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA

24. SUBMIT INVOICES TO ADDRESS SHOWN IN

(4 copies unless otherwise specified)

ITEM 25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) ( ) 41 U.S.C. 253(c) ( )

26. ADMINISTERED BY CODE 27. PAYMENT WILL BE MADE BY

U.S. Army Engineer District, Omaha 1616 Capitol Ave.

Omaha, Nebraska 68102-4901

USAED Omaha c/o USACE Finance Center 5722 Integrity Drive Millington, TN 38054-5005

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

28. NEGOTIATED AGREEMENT (contractor is required to sign this document and return _______ copies to issuing office.) Contractor agrees to furnish and deliver all items or perform all work, requisitions identified on this form and any continuation sheets for the consideration stated in this contract. The rights and obligations of the parties to this contract shall be governed by (a) this contract award,

(b) the solicitation, and (c) the clauses, representations, certifications, and specifications incorporated by reference in or attached to this contract.

29. AWARD (Contractor is not required to sign this document.) Your offer on this solicitation, is hereby accepted as to the items listed. This award consummates the contract, which consists of (a) the Government solicitation and your offer, and (b) this contract award. No further contractual document is necessary.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED

TO SIGN (Type or print)

31A. NAME OF CONTRACTING OFFICER (Type or print)

30B. SIGNATURE 30C. DATE 31B. UNITED STATES OF AMERICA

BY

31C. AWARD DATE

STANDARD FORM 1442 BACK (REV. 4-85)

CLIN SCHEDULE 00 10 00 - 3 W9128F-16-R-0076

CONTRACT LINE ITEM PRICING SCHEDULE

ITEM NO. DESCRIPTION QUANTITY UNIT AMOUNT

BASIC ITEMS

Entire work complete to Design Dormitory and Related Site Work, FY16 FXBM063002, Ellsworth AFB, South Dakota, excluding options listed below.

1 Job $_____________________

0002 Entire work complete to Construct Dormitory, FY16 FXBM063002, Ellsworth AFB, South Dakota, up to the five foot line, excluding Item 0007 listed below.

1 Job $_____________________

0003 Entire work complete to Construct Site Work beyond the 5 foot line of the New Dormitory, excluding Item 0004 and Option Items listed below.

1 Job $_____________________

0004 Entire work complete for Demolition and Site Work associated with Demolition of Building 4207 (Jefferson Hall), excluding Item 0010 below.

1 Job $_____________________

TOTAL BASIC AMOUNT $_____________________________

OPTION ITEMS

[Option]

Entire work complete for Design and Installation of Landscape plan and associated Permanent Irrigation system excluding Seeding and Temporary Irrigation system associated with Seeding.

1 Job $______________________ m 0010

CLIN SCHEDULE 00 10 00 - 4 W9128F-16-R-0076

[Option]

Entire work complete for Design and Installation of Site Furnishings, Basketball Court, and Associated Sidewalk and Paving, with the exception of Bicycle Racks.

1 Job $______________________

[Option]

Entire work complete to Procure and Install Furniture, Fixtures, and Equipment in accordance with the plans and specifications (notably Sections 01 84 00 and 12 50

00.13 10).

1 Job $______________________

[Option]

Entire work complete to Design and Construct Parking Lot including Associated Lighting and Storm Drainage.

1 Job $______________________

[Option]

Entire work complete to Procure and Install Security (CCTV) Cameras and Associated Equipment.

1 Job $______________________

[Option]

Entire work complete to Remove and Relocate Existing Dormitory Furnishings to DLADS per Inventory provided in Appendix.

1 Job $______________________

TOTAL AMOUNT (BASIC PLUS OPTIONS) $_________________________________

NOTES:

1. See SECTION 00 21 01, INSTRUCTIONS, CONDITIONS, & NOTICES TO BIDDERS for evaluation of options. The Government reserves the right to exercise options: 0007, 0009, and 0010 within 540 days; and all other options within 90 days after issuance of Notice to Proceed.

2. Prices must be entered for all items of the schedule. Total amounts submitted without prices being entered on individual items will be rejected. Additions will be subject to verification by the Government. In case of variation between the Job (lump-sum) prices and the total amount, the lump-sum prices will be considered the price submitted.

FY16 Dormitories (FXBM063002) - Ellsworth AFB, SD EL85

SECTION TABLE OF CONTENTS

DIVISION 01 - GENERAL REQUIREMENTS

SECTION 01 82 00

ARCHITECTURAL REQUIREMENTS

PART 1 GENERAL

1.1 REFERENCES

1.2 PURPOSE OF THE FACILITIES

1.2.1 Dormitory (144 Person)

1.3 FUNCTIONAL PLAN REQUIREMENTS

1.3.1 General

1.3.2 Facility Design

1.3.3 Handicap Accessibility

1.3.4 Elevator

1.3.5 Antiterrorism/Force Protection

1.3.6 Desired Exterior Image and Architectural Compatibility

1.3.7 Sustainable Design

1.3.8 Air Barrier

1.4 TECHNICAL SPECIFICATIONS

1.5 TYPE AND METHOD OF CONSTRUCTION

1.5.1 Facility Construction

1.5.1.1 Prefabricated Unit Construction Prohibited

PART 2 PRODUCTS

2.1 ROOF

2.1.1 Standing Seam Metal Roof

2.1.1.1 Design Requirements

2.1.1.2 Design Conditions

2.1.1.2.1 Wind Uplift

2.1.1.2.2 Roof Live Loads

2.1.1.2.3 Thermal Movement

2.1.1.2.4 Deflection

2.1.1.3 Structural Performance

2.1.1.4 Snow Rail

2.1.1.5 Warranty Requirements

2.2 ROOF ACCESSORIES

2.3 FALL PROTECTION ANCHORS

2.4 WINDOWS

2.5 CURTAINWALL/STOREFRONTS

2.6 EXTERIOR CLOSURE AND WALL FRAMING

2.7 MASONRY

2.7.1 Split-Face Concrete Masonry Units (CMU)

2.7.1.1 Aggregates

2.7.1.2 Kinds and Shapes

2.7.2 Oversized Clay or Shale Brick (Light and Dark)

2.7.3 Precast Stone Trim, Edging, Coping, Headers, Sills, etc.

2.7.3.1 Physical Properties

2.7.3.2 Fine Aggregates

2.7.3.3 Coarse Aggregates

2.7.3.4 Portland Cement

2.7.3.5 Colors

SECTION 01 82 00 Page 1

2.7.3.6 Admixtures

2.7.3.7 Water

2.7.3.8 Reinforcing

2.7.3.9 Anchoring Devices

2.7.4 Mortar

2.7.4.1 Masonry Cement

2.7.4.2 Admixtures

2.7.5 Masonry Accessories

2.8 FIBER CEMENT SIDING

2.8.1 Material and Workmanship Warranty

2.8.2 Factory Finish Warranty

2.8.3 Compatibility

2.8.4 Fiber Cement Siding

2.8.4.1 Horizontal Lap Siding

2.8.4.2 Battens, Trim, and Edging

2.8.5 Factory-Applied Finish

2.9 Accessories

2.8.6 Mechanical Fasteners

2.8.7 2.9 Accessories

2.8.8 Weather Barrier

2.8.8.1 Joint Tape

2.8.9 Fenestration Flashing

2.8.10 Joint Sealant

2.9 DOORS

2.9.1 Exterior Doors

2.9.1.1 Doors for Egress

2.9.1.2 Exterior Hollow Metal Doors

2.9.1.3 Doors in Curtainwall/Storefronts

2.9.1.4 Glazing

2.9.1.5 Thresholds

2.9.2 Interior Doors

2.9.3 Fire Doors

2.9.4 Hardware

2.9.4.1 Door Closers

2.9.4.2 Keyed Access Entry Control System

2.9.4.2.1 Module Keying Strategy

2.9.4.3 Basic Keyless Access Rough-In

2.10 INTERIOR CONSTRUCTION

2.10.1 Wall Framing

2.10.2 Gypsum Wall Board

2.10.3 Insulation

2.10.3.1 Sound Insulation/Isolation

2.7 Ceilings

2.10.4 Gypsum Board

2.10.5 Acoustical Ceiling Tile

2.11 FLOWABLE GYPSUM/CEMENT SUBFLOOR TOPPING

2.12 STEEL PAN STAIRS

2.12.1 General

2.12.2 Steel Stairs

2.12.2.1 Design Loads

2.12.2.2 Materials

2.12.3 Hardware/Accessories

2.12.4 Concrete Treads

2.12.5 Field Welding

2.12.6 Touchup Painting

2.13 INTERIOR SEALANT

2.14 FINISHES

2.15 WINDOW HEAD/JAMB/STOOLS

2.16 CABINETRY

SECTION 01 82 00 Page 2

2.17 ABOVE-THE-RANGE MICROWAVE OVEN

2.18 BULLETIN BOARDS/TACKBOARDS (BB)

2.19 MAILBOXES

2.20 2.18 WALL-MOUNT TELVISION BRACKET (TVM)

2.21 CORNER GUARDS

2.22 EXTERIOR BUILDING NUMBER AND NAME SIGNAGE

2.23 TOILET ACCESSORIES

2.24 BATHROOM VANITIES

2.25 WIRE SHELVING

2.25.1 Shelving Accessories

2.26 BATHTUBS AND BATHTUB SURROUNDS

2.27 VENDING MACHINE ACCOMODATIONS

PART 3 EXECUTION

3.1 Not Used

-- End of Section Table of Contents --

SECTION 01 82 00 Page 3

SECTION 01 82 00

ARCHITECTURAL REQUIREMENTS

PART 1 GENERAL

1.1 REFERENCES

The design publications listed below shall be used as sources of criteria for the architectural design. The most current edition of the code or standard shall be used as criteria for the design. The criteria from these sources may be supplemented but not supplanted, by applicable criteria contained in nationally recognized codes and standards.

United States Air Force (USAF)

DORMS-4-AIRMEN Unaccompanied Housing Design Guide, dated January 2006.

ETL 04-3 Design Criteria for Prevention of Mold in Air Force Facilities (Change 1), dated April 2004.

AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

AAMA 2605 (2005) Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI A 108.1 (2013) Installation of Ceramic Tile

ANSI A 137.1 (2008) American National Standard Specifications For Ceramic Tile

ANSI A 250.8 Standard Steel Doors and Frames

ASTM INTERNATIONAL (ASTM)

ASTM A 82 (2007) Standard Specification for Steel Wire, Plain, for Concrete Reinforcement

ASTM A 167 (1999; R 2009) Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip

ASTM A 666 (2010) Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar

ASTM A 755/A 755M (2011) Standard Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process and Prepainted by the Coil-Coating

SECTION 01 82 00 Page 4

Process for Exterior Exposed Building Products

ASTM B 370 (2009) Standard Specification for Copper Sheet and Strip for Building Construction

ASTM C 36/C 36M (2003e1) Gypsum Wallboard

ASTM C 216 (2007a) Facing Brick (Solid Masonry Units Made from Clay or Shale)

ASTM C 270 (2008a) Standard Specification for Mortar for Unit Masonry

ASTM C 616 (2008) Standard Specification for Quartz-Based Dimension Stone

ASTM C 734 (2006) Low-Temperature Flexibility of Latex Sealants After Artificial Weathering

ASTM C 834 (2005) Latex Sealants

ASTM C 840 (2008) Application and Finishing of Gypsum Board

ASTM C 919 (2008) Use of Sealants in Acoustical Applications

ASTM C 920 (2008) Standard Specification for Elastomeric Joint Sealants

ASTM C 1036 (2006) Standard Specification for Flat Glass

ASTM C 1172 (2009) Standard Specification for Laminated Architectural Flat Glass

ASTM C 1184 (2005) Standard Specification for Structural Silicone Sealants

ASTM C 1325 (2008) Standard Specification for Non-Asbestos Fiber-Mat Reinforced Cement Substrate Sheets

ASTM C 1396/C 1396M (2009) Standard Specification for Gypsum Board

ASTM D2244 (2011) Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates

ASTM D2247 (2011) Testing Water Resistance of Coatings in 100% Relative Humidity

ASTM D 3273 (2000; R 2005) Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber

ASTM D4214 (2007) Standard Test Method for Evaluating

SECTION 01 82 00 Page 5 the Degree of Chalking of Exterior Paint Films

ASTM D522 (1993a; R 2008) Mandrel Bend Test of Attached Organic Coatings

ASTM D968 (2005; R 2010) Abrasion Resistance of Organic Coatings by Falling Abrasive

ASTM E 84 (2009c) Standard Test Method for Surface Burning Characteristics of Building Materials

ASTM E 136 (2009) Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C

ASTM E 1264 (2008) Acoustical Ceiling Products

ASTM E 1514 (2011) Standard Specification for Structural Standing Seam Steel Roof Panel Systems

ASTM E1592 (2005; R 2012) Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E 1745 (2004) Standard Specification for Water Vapor Retarders Used in Contact with Soil or Granular Fill Under Concrete Slabs

ASTM G 152 (2013) Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials

ARCHITECTURAL WOODWORK INSTITUTE (AWI)

AWI Qual Stds (8th Edition) AWI Quality Standards

GYPSUM ASSOCIATION (GA)

GA 214-10 (2007) Recommended Levels of Gypsum Board Finish

GA 216-13 (2007) Application and Finishing of Gypsum Board

GA 600 (2009) Fire Resistance Design Manual

INTERNATIONAL CODE COUNCIL (ICC)

ICC IBC (2015) International Building Code

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 10 (2013) Standard for Portable Fire Extinguishers

SECTION 01 82 00 Page 6

NFPA 101 (2015) Life Safety Code

NFPA 252 (2012) Standard Methods of Fire Tests of Door Assemblies

NFPA 80 (2013) Standard for Fire Doors and Other Opening Protectives

NATIONAL WOOD WINDOW AND DOOR ASSOCIATION (NWWDA)

AAMA/NWWDA 101/I.S.2 (1997) Voluntary Guide Specifications for Aluminum, Poly(Vinyl Chloride)(PVC) and Wood Windows and Glass Doors

ALUMINUM ASSOCIATION (AA)

AA DAF-45 (2003) Designation System for Aluminum Finishes

AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)

ASCE 7 (2013) Minimum Design Loads for Buildings and Other Structures

SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION

(SMACNA)

SMACNA 1793 (2012) Architectural Sheet Metal Manual, 7th Edition

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames

U.S. ACCESS BOARD

ABA (1968) Architectural Barriers Act

ADAAG (2010) Americans with Disabilities Act (ADA) Accessibility Guidelines

U.S. DEPARTMENT OF DEFENSE (DOD)

UFC 1-200-01 General Building Requirements, dated 20 June 2016

UFC 1-200-02 High Performance and Sustainable Building Requirements, with Change 3, date 2013

UFC 3-101-01 Architecture, dated 28 November 2011

UFC 3-210-10 (15 Nov 2010) Low Impact Development

UFC 3-600-01 Design: Fire Protection Engineering for Facilities (08-08-2016)

UFC 4-010-01 (2012; Change 1 2013) DoD Minimum Antiterrorism Standards for Buildings

SECTION 01 82 00 Page 7

UFC 1-200-02 (2013) High Performance and Sustainable Building Requirements, with Change 3

MIL HDBK 1013/1A Design Guidelines for Physical Security of Facilities, DEC 1993

MIL HDBK 1013/1A Design Guidelines for Physical Security of Facilities, DEC 1993

MIL HDBK 1190 Facility Planning and Design Guide, 1987

U.S.GREEN BUILDING COUNCIL (USGBC)

LEED (2009) Leadership in Energy and Environmental Design™ Rating System for Building Design and Construction (LEED

BD+C)

LEED Reference Guide (2009) LEED Reference Guide for Building Design and Construction

UNDERWRITERS LABORATORIES (UL)

UL 10B (2008; Reprint Apr 2009) Fire Tests of Door Assemblies

WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)

WDMA I.S. 1-A (2011) Architectural Wood Flush Doors

1.2 PURPOSE OF THE FACILITIES

1.2.1 Dormitory (144 Person)

This project consists of the design and construction of new four-story Dormitory buildings with 144 single-occupant bedrooms with associated, infrastructure, support spaces and facilities. Total allowable square footage shall not exceed 59,675 SF as defined by UFC 3-101-01 and its references.

1.3 FUNCTIONAL PLAN REQUIREMENTS

1.3.1 General

The facility, as described herein consists ofone Dormitory consisting of three buildings to house a total of 144 personnel to be located at Ellsworth Air Force Base, SD. The facility shall conform to the requirements of UFC 1-200-01 General Building Requirements and DORMS-4-AIRMEN design standard. In the event of a conflict, Designer of Record shall comply with requirements in this Contract (including bridging documents), the DORMS-4-AIRMEN standard, and UFC requirements - in that order of precedence. If a conflict between other reference documents or criteria occurs, the more stringent requirement shall govern.

Drawings have been provided in the appendices as bridging documents. The floor plans for this project are to be the basis of design for the intended floor plan layout as required under this RFP.

SECTION 01 82 00 Page 8

The overall building design and configuration has been developed by the Government and approved by the users. It was determined by the Government that this was the best solution to meet the users' needs for the design development of this project. However, other design solutions which slightly modify the furnished solution may be acceptable, and will be reviewed on their design merits against the furnished criteria, subject to Government approval.

Design alterations will only be allowed as required for the following:

a. Code compliance.

b. Material modular sizing considerations.

c. Economy of detail connections.

d. Access to/for building systems and utilities.

e. Accommodation of required structural, mechanical, plumbing, fire protection, electrical, and communication systems.

f. Handicap accessibility provisions.

The architectural drawings, specifications, design analysis and calculations to accurately show the extent of work, are to be provided as required for this proposal, for the charrette, 60 percent design, and the Final design submittals, and shall be in accordance Sections 01 33 00.32

DESIGN AND CONSTRUCTION DELIVERABLES/PROCEDURES 01 33 00.36 - 60 PERCENT

DESIGN REQUIREMENTS, and 01 33 00.38 - 100 PERCENT DESIGN REQUIREMENTS.

The project is based upon English measuring units, and all dimensioning shown on drawings shall be indicated in English units.

1.3.2 Facility Design

Approximate 35% design architectural drawings have been included in the appendices of this Contract as bridging documents. The Dormitory facility shall be designed to accommodate 144 bedrooms total and meet LEED Silver (v2009) certification requirements. Each building will be substantially identical and shall have two dorm modules (8 beds) on the first floor followed by four modules (32 beds) on the second and third floors, followed by two modules (8 beds) on the fourth floor. The facility shall conform to the requirements below and as listed in this Contract.

Fire separation walls and egress from the facility shall meet or exceed the requirements of NFPA 101 Life Safety Code. The facility shall be protected by an automatic fire sprinkler system throughout the building. See Section 01 86 13 FIRE PROTECTION REQUIREMENTS as well as UFC 3-600-01 Design: Fire Protection Engineering for Facilities.

1.3.3 Handicap Accessibility

These facilities are primarily intented for able-bodied, military personnel, but shall be designed in compliance with the Architectural Barriers Act (ABA) to the greatest extent practical within the requirements and limits dictated herein. Other accessible Dormitories are available elsewhere on Ellsworth AFB, so the dorm modules in this facility need not be fully-accessible. All public spaces, corrdiors and features outside of the dorm units shall be fully accessible. Requirements for vertical connection of accessible routes need not be met.

SECTION 01 82 00 Page 9

1.3.4 Elevator

Provide an elevator and all supporting features and infrastructure in each dormitory building. Accomodations shall be made in the design to accomodate the elevator and all associated systems. Accomodations include - but are not limited to - a pit, chase, overhead hoist beam, and mechanical and electrical systems. Elevator capacity shall not be less than 2,500 lb and shall be of a plan size/dimension sufficient to accomodate a standard dormitory bed as identified in the plans. Elevator shall be "holed" or "hole-less" hydraulic type of configuration adquate for the height and configuration of the proposed dormitory buildings.

1.3.5 Antiterrorism/Force Protection

This building shall include design provisions meeting the requirements of UFC 4-010-01, DOD Minimum Antiterrorism Standards for Buildings. This includes, but is not limited to, minimum setbacks from parking areas and vehicle access drives, glazing and blast resistance requirements, progressive-collapse, visual screening, HVAC intake louvers location requirements, and other protective features as outlined in the UFC.

1.3.6 Desired Exterior Image and Architectural Compatibility

This project represents the first phase of a new dormitory master plan at Ellsworth AFB. While this project will be the first-constructed application of that master plan, Ellsworth AFB has studied the desired aesthetic. The bridging documents in the appendices identify some of the essential aesthetic components that shall be into this project. Also note that Ellsworth AFB has many buildings that reference a "Prairie-Style" set of aesthetic queues. The buildings in this Project shall emphasize horizontal lines, large roof overhangs, and emply other "Prairie-School" techniques to create visual continuity between the buildings in this Project and existing "Prairie-Style" buildings on base. Required materials have been selected for the project to achieve the shared values of low operating and maintenance costs, energy efficiency, durability, and compatibility with other new construction on Base. Any materials not specifically identified shall also be selected with those shared values in mind.

1.3.7 Sustainable Design

The architectural design of this building shall include design features which incorporate and promote sustainable design principles for the built environment and shall be certified for LEED silver, as outlined in the U.S.

Green Building Council's USGBC LEED (Leadership in Energy and Environmental Design) Rating System, and the Air Force Sustainable Facilities Guide.

Refer to 01 11 00 SUMMARY OF WORK and LEED-BD+C Version 2009, Registered Project Checklist, for more information on LEED and sustainable design requirements.

1.3.8 Air Barrier

An air barrier shall be designed, installed, and tested as applicable following requirements in UFC 1-200-02 and UFC 3-101-01. The design drawings shall indicate air barrier limits and provide detail drawings and specifications for construction installation, inspection, and testing.

The building air leakage rate shall be determined by testing to 0.2 in.

water (50 Pa) and extrapolating the test results to 0.3 in. water (75 Pa).

SECTION 01 82 00 Page 10

The building air leakage rate must not exceed 0.4 cfm/ft2 (2.00 L/s-m2) when test results are extrapolated to 0.3 inches water (75 Pa). Use of 0.2 inches water (50 Pa) test pressure allows for the use of the building HVAC system to provide test pressure.

Use UFGS Section 07 05 23 Pressure Testing an Air Barrier System for Air Tightness in the project specifications.

1.4 TECHNICAL SPECIFICATIONS

Technical specifications shall be developed and coordinated with the drawings to accurately and clearly identify the selected products and installation requirements proposed for this facility.

Certain specifications and performance requirements, deemed critical to the project, have been included herein. Where requirements are not covered in the guide specifications, specification sections shall be prepared to cover those subjects and shall be in the same format as the RFP specifications.

1.5 TYPE AND METHOD OF CONSTRUCTION

1.5.1 Facility Construction

The facility shall be designed as permanent construction. The definition of permanent construction per MIL HDBK 1190 is, "Buildings and facilities designed and constructed to serve a life expectancy of more than 50 years, should be energy efficient, and must have finishes, materials, and systems selected for low maintenance and low life-cycle cost." Reference UFC 1-200-02 High Performance and Sustainable Building Requirements.

The overall building occupancy classification for the Dormitory (144 Room) project is Group R-2 per IBC 2015. Construction "Type V" shall be used for the facility. Provide fire protection, separation, and life safety features as necessary for the occupancy and type of construction listed.

1.5.1.1 Prefabricated Unit Construction Prohibited

Unitized construction where entire dorm units or modules are prefabricated off-site and then assembled or "stacked" on-site is prohibited on this project.

Panelized construction (Structural Insulated Panels "SIPs," panelized wall systems, etc) and other types of prefabricated assemblies are acceptable.

PART 2 PRODUCTS

2.1 ROOF

2.1.1 Standing Seam Metal Roof

2.1.1.1 Design Requirements

a. Panels shall be continuous lengths, not less than 22 GA, up to manufacturer's standard longest lengths, with no joints or seams, except where indicated or specified. Provide panels with intermediate ribs or striations to minimize oil-canning. Ribs of adjoining sheets shall be in continuous contact from eave to ridge. Individual panels of snap together type systems shall be removable for replacement of damaged material.

SECTION 01 82 00 Page 11

b. There shall be no exposed or penetrating fasteners except where shown on approved shop drawings. Fasteners into steel shall be stainless steel, zinc cast head, or cadmium plated steel screws inserted into predrilled holes. There shall be a minimum of two fasteners per clip. Single fasteners will be allowed when supporting structural members are prepunched or predrilled.

c. Snap together type systems shall have a capillary break and a positive side lap locking device. Field-formed seam type systems shall be mechanically locked closed by the manufacturer's locking tool. The seam shall include a continuous factory applied sealant when required by the manufacturer to withstand the wind loads specified.

d. Roof panel anchor clips shall be concealed and designed to allow for longitudinal thermal movement of the panels, except where specific fixed points are indicated. Provide for lateral thermal movement in panel configuration or with clips designed for lateral and longitudinal movement.

2.1.1.2 Design Conditions

The system shall be designed to resist positive and negative loads specified herein in accordance with the AISI SG03-3. Panels shall support walking loads without permanent distortion or telegraphing of the structural supports.

2.1.1.2.1 Wind Uplift

The design uplift pressures for the roof system shall be computed and applied using the components and cladding wind loads shown on the contract drawings.

The design uplift force for each connection assembly shall be that pressure given for the area under consideration, multiplied by the tributary load area of the connection assembly, and multiplied by the appropriate factor of safety, as follows:

a. Single fastener in a connection: 3.0

b. Two or more fasteners in each connection: 2.25

2.1.1.2.2 Roof Live Loads

Loads shall be applied on the horizontal projection of the roof structure.

The design roof live load and snow load shall be as given on the contract drawings.

2.1.1.2.3 Thermal Movement

System shall be capable of withstanding thermal movement based on a temperature range of 30 degrees F below zero and 160 degrees F.

2.1.1.2.4 Deflection

Panels shall be capable of supporting design loads between unsupported spans with deflection of not greater than L/180 of the span.

SECTION 01 82 00 Page 12

2.1.1.3 Structural Performance

The structural performance test methods and requirements of the Standing Seam Roofing Systems (SSRS) shall be in accordance with ASTM E 1592.

2.1.1.4 Snow Rail

A snow retention/rail system is required at locations indicated on Roof Plan. Snow rail system shall be designed to resist the vector forces resulting from the design roof snow loads. Calculate frequency of devices by using tested ultimate holding values for the device and a factor of safety of 2.0.

Contractor submittals are to include snow rail system frequency calculations specific to the product being submitted and documentation from an independent laboratory indicating holding strength of the device. Snow loads and loads imposed on the SSSMR by the snow guards shall be coordinated between the snow guard manufacturer and the standing seam metal roof manufacturer. Standing seam metal roofing, retention clips, subpurlins, and connections to structure shall be designed for the loads imposed on the roofing system by the snow rails.

2.1.1.5 Warranty Requirements

Furnish manufacturer's materials and workmanship warranty for the roofing system. The warranty period shall be not less than 20 years from the date of Government acceptance of the work. The warranty shall be issued directly to the Government.

The warranty shall include coverage for sustained wind speed and/or peak wind gusts up to 100 mph and shall provide that if within the warranty period the metal roofing system becomes non-watertight or shows evidence of corrosion, perforation, rupture or excess weathering due to deterioration of the roofing system resulting from defective materials or installed workmanship the repair or replacement of the defective materials and correction of the defective workmanship shall be the responsibility of the roofing system manufacturer.

This includes roof penetration items such as vents and curbs; interior or exterior gutters and downspouts; eaves, ventilating ridge cap, hip, valley, rake, gable, wall, or other roof system flashings installed and any other components specified within this contract to provide a weathertight roof system; and items specified in other sections of these specifications that are part of the SSSMR system.

Repairs that become necessary because of defective materials and workmanship while roofing is under warranty shall be performed within 7 days after notification, unless additional time is approved by the Contracting Officer. Failure to perform repairs within the specified period of time will constitute grounds for having the repairs performed by others and the cost billed to the manufacturer. The Contractor shall also provide a 2 year contractor installation warranty.

2.2 ROOF ACCESSORIES

Sheet metal flashings, boots, curbs, trim, moldings, closure strips, caps, snow guards, and other similar sheet metal accessories used in conjunction with primary roofing materials shall be of the same material compatible with the roof system provided.

SECTION 01 82 00 Page 13

Provide gutters only in areas required to divert water away from pedestrian access to the building and main entrances. Size in accordance with SMACNA 1793. Gutters shall drain at grade (via downspouts) to the subgrade site stormwater management system.

Fasteners shall be zinc-coated steel, corrosion resisting steel, zinc cast head, or nylon capped steel, type and size specified below or as otherwise approved for the applicable requirements.

A snow retention/guard system is required at all roof conditions that slope and terminate in the direction of an exterior door below. Snow guards shall be the metal bar or pipe type, compatible with the roof system provided. Snow guards shall be a product from a manufacturer regularly engaged in the production of such products and approved by the roofing material manufacturer for use on this project. Method of attachment must not void roofing material and roofing system warranties.

2.3 FALL PROTECTION ANCHORS

Provide roof-mounted fall protection anchor points to allow access to any roof-mounted mechanical equipment. Anchor points shall be compatible with the furnished roof system and meet all applicable OSHA loading and access requirements.

2.4 WINDOWS

Windows shall be tinted, laminated, low-E, insulated units. Window units shall have an R-value (Winter nighttime) of 3.5 or higher. Window frames shall be thermally broken aluminum. Windows in dorm modules shall be operable and meet ICC IBC emergency egress window size and clear opening requirements, regardless of what code exemptions may apply. Finish shall meet AAMA 2605. All operable windows provided shall have locks and insect screens. Fenestration flashing for window, louver, door, and other wall penetrations shall be a self-adhering sheet product conforming to AAMA 711 designed for use at wall fenestration openings to bridge the interface between the rough opening and the building envelope. An example of an acceptable product is DuPont's "FlexWrap NF", or an approved equal. The fenestration flashing shall be compatible with the exterior sheathing, weather barrier, and adjoining materials. Windows shall comply with applicable portions of UFC 4-010-01, DOD Minimum Antiterrorism Standards for Buildings.

2.5 CURTAINWALL/STOREFRONTS

Curtainwall and storefronts shall be provided in the general size and configuration indicated in the bridging documents. Glazing units shall be tinted, laminated, low-E, and insulated. Curtainwall units shall have an R-value (Winter nighttime) of 3.5 or higher. Spandrel glazing, as required, shall also be installed as a glazing unit. Frames shall be thermally broken aluminum. Finish shall meet AAMA 2605. Fenestration flashing shall be a self-adhering sheet product conforming to AAMA 711 designed for use at wall fenestration openings to bridge the interface between the rough opening and the building envelope. An example of an acceptable product is DuPont's "FlexWrap NF", or an approved equal. The fenestration flashing shall be compatible with the exterior sheathing, weather barrier, and adjoining materials. Curtainwalls and storefronts shall comply with applicable portions of UFC 4-010-01, DOD Minimum Antiterrorism Standards for Buildings.

SECTION 01 82 00 Page 14

2.6 EXTERIOR CLOSURE AND WALL FRAMING

Exterior construction and detailing shall follow "cavity wall" with masonry veneer best practices and industry standards. Exterior envelope shall be comprised of the items identified below:

a. Exterior Cladding (see bridging documents)

b. Air space (at masonry veneer)

c. Weather/air barrier

d. Continuous rigid insulation (at masonry veneer)

e. Exterior sheathing

f. Exterior wall framing with batt or spray foam insulation in stud cavity

g. Vapor or air barrier as required

h. Gypsum wall board

i. Finish as required

Alternative framing (such as Structural Insulated Panels (SIPS)) and cladding systems may be acceptable, and will be reviewed on their design merits against the furnished criteria, subject to Government approval. All selections and detailing will be evaluated for their conformance to the established aesthetic preferences, durability, maintenance and the intended design life of the facility.

Exterior wall framing shall be Type V whenever possible. Protect construction in accordance with NFPA 101, ICC IBC and UFC 03-600-01, as applicable. Other types of construction be allowed if deemed necessary to meet ATFP, progressive collapse, or life safety criteria. Wood framing shall conform to the requirements identified in UFGS 06 10 00 ROUGH

CARPENTRY.

The building envelope shall meet all applicable UFC, ASHRAE, and LEED criteria applicable to this type of facility.

2.7 MASONRY

Provide exterior cladding and closure with the materials described below:

2.7.1 Split-Face Concrete Masonry Units (CMU)

Provide CMUs of a size, type, and texture compatible with existing materials found on base and that mimicks the aesthetic reference images found in the bridging documents.

Cement shall have a low alkali content and be of one brand. Units may contain post-consumer or post-industrial recycled content. Units shall be of modular dimensions and air, water, or steam cured. Minimum compressive strength (average of 3 units) shall be 1900 psi as per ASTM C 90.

a. Hollow Load-Bearing Units: ASTM C 90, made with lightweight, or medium weight,or normal weight aggregate.

b. Solid Load-Bearing Units: ASTM C 90, lightweight, medium weight, or normal weight units.

2.7.1.1 Aggregates

Lightweight aggregates and blends of lightweight and heavier aggregates in

SECTION 01 82 00 Page 15 proportions used in producing the units, shall comply with the following requirements when tested for stain-producing iron compounds in accordance with ASTM C 641: by visual classification method, the iron stain deposited on the filter paper shall not exceed the "light stain" classification.

Use industrial waste by-products (air-cooled slag, cinders, or bottom ash), ground waste glass and concrete, granulated slag, and expanded slag in aggregates. Slag shall comply with ASTM C 989; Grade 80, 100, or 120.

2.7.1.2 Kinds and Shapes

Units shall be modular in size and shall include closer, jamb, header, lintel, and bond beam units and special shapes and sizes to complete the work as indicated. In exposed interior masonry surfaces, units having a bullnose shall be used for vertical external corners except at door, window, and louver jambs. Radius of the bullnose shall be 1 inch. Units used in exposed masonry surfaces in any one building shall have a uniform fine to medium texture and a uniform color.

2.7.2 Oversized Clay or Shale Brick (Light and Dark)

Brick size, type, color, and coursing shall mimick the aesthetic precedences found in the bridging documents. Clay or shale brick veneer shall be masonry units conforming to ASTM C 216, Type FBS. Color range and texture shall be selected to match adjacent existing construction. Brick units shall be delivered factory-blended to provide a uniform appearance and color range in the completed wall. Grade SW shall be used for all brickwork.

2.7.3 Precast Stone Trim, Edging, Coping, Headers, Sills, etc.

Provide precast concrete stone shapes in sizes, colors, and configurations necessary to mimic the aesthetic illustrated in the bridging documents.

2.7.3.1 Physical Properties

ASTM C 1364. Provide the following:

1. Compressive Strength - ASTM C 1194: 6,500 psi minimum for products at 28 days.

2. Absorption - ASTM C 1195: 6% maximum by the cold water method, or 10% maximum by the boiling method for products at 28 days.

3. Air Content – ASTM C 173 or ASTM C 231, for wet cast product shall be 4-8% for units exposed to freeze-thaw environments. Air entrainment is not required for VDT products.

2.7.3.2 Fine Aggregates

ASTM C 33, except for gradation. Manufactured or natural sand.

2.7.3.3 Coarse Aggregates

ASTM C 33, except for gradation. Aggregates shall be quartz, limestone, marble and / or other materials required to produce the referenced color and texture finish.

SECTION 01 82 00 Page 16

2.7.3.4 Portland Cement

Portland cement shall comply with ASTM C 150 Type I and be a combination of white cement and buff cement proportioned to achieve the referenced color and texture. The portland cement blend shall not consist of fly ash, pozzolan and/or ground slag.

2.7.3.5 Colors

Inorganic iron oxide pigments, ASTM C 979 except that carbon black pigments shall not be used.

2.7.3.6 Admixtures

ASTM C 260 for air-entraining admixtures. Other admixtures: ASTM C 494 for water reducing, retarding or accelerating. Certify that admixtures are free of chlorides.

2.7.3.7 Water

Fresh, clean, and potable.

2.7.3.8 Reinforcing

ASTM A 615/A 615M. Reinforcing steel shall be galvanized or epoxy coated when clearance to an exterior face is 1-1/2 inches or less. Reinforce the units as recommended by the Cast Stone Institute Technical Manual and for safe handling and structural stress.

a. Minimum reinforcing shall be 0.25 percent of the cross section area.

b. Panels and similar stones greater than 24 inches in one direction shall be reinforced in that direction. Units less than 24 inches in both their length and width dimension shall be non-reinforced unless otherwise specified.

c. Welded wire fabric shall be ASTM A 82 where applicable for wet cast units. Welded wire fabric reinforcing shall not be used in dry cast products.

2.7.3.9 Anchoring Devices

All anchors, dowels and other anchoring devices and shims shall be standard building stone anchors commercially available in non-corrosive brass or Type 304 stainless steel.

2.7.4 Mortar

Provide masonry mortar of type and mix applicable to the install condition.

Color shall mimic the selections found on the adjacent FY2000 Dormitory -for the corresponding location of placement.

Mortar shall conform to ASTM C 270, Type S. Mortar mix shall be based on proportion specifications. Laboratory testing of mortar shall be in accordance with the preconstruction evaluation of mortar section of ASTM C 780. Cement shall have a low alkali content and be of one brand.

Aggregates shall be from one source.

SECTION 01 82 00 Page 17

2.7.4.1 Masonry Cement

Masonry cement in conformance with ASTM C 91 may be used in the mortar.

When using a masonry cement a comparative test shall be performed between a Portland cement-lime mortar and the masonry cement mortar proposed for the project to evaluate the ASTM C 1072 bond and the ASTM C 780 compressive strength of the two mixes. The test shall be conducted with the proposed masonry units for the project.

This is the start of the file's text. The full file is on GovTribe.