AM01 DRAWINGS for W9127821R0028.pdf

PDF 3 MB Posted

Attached to
ERCIP 7. 5MW RICE Generator and Micro Grid Controls Federal contract opportunity
Solicitation number
W9127821R0028
Issued by
Department of the Army Corps of Engineers Engineering District Mobile

About this file

This document package includes drawings and specifications for a federal contract solicitation. The solicitation is for the installation of a 7.5MW rice generator and microgrid controls at Anniston Army Depot in Alabama. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Mobile and is identified by number W9127821R0028. The drawings depict the site plans, equipment details, and specifications for the generator, load bank, switchgear, and associated electrical infrastructure. Products and services required include installation of reclosers in the existing distribution system, a 2,875kVA transformer, 2,500kW load bank, switchgear, and all associated conduits and wiring. The response due date and award date are not provided.

View the file

Other files for this federal contract opportunity

Other files attached to ERCIP 7. 5MW RICE Generator and Micro Grid Controls, newest first.
File Type Posted
AM01 for W9127821R0028.pdf PDF
ERCIP_Sign In Sheet_Site Visit_30 Mar 2021.pdf PDF
VOL1.PDF PDF
VOL2.PDF PDF
EM 385-1-1.pdf PDF
RTA DRAWINGS.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers®

MOBILE DISTRICT

109 SAINT JOSEPH STREET

MOBILE, AL 36602

7.5MW RICE GENERATOR AND

MICRO GRID CONTROLS

ANNISTON ARMY DEPOT, ALABAMA

CALHOUN

MARCH 20 1

BY20001

SOLICITATION W9127821R0028

AMENDMENT NO. 0001

M B

Y

1C

-0

.D W

G

C-001

G E

N E

R A

L N

O

TE

S

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

US Army Corps of Engineers

SHEET ID

S O

LI

C

IT

A

TI

O

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

TE

D B

Y

C O

N

TR

A C

T N

O

A N

S I D

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

TE

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9

P R

O

JE

C T

N U

M B

E R

FI

LE

N A

M E

A U

G U

S T

- - M B

Y

R . W

E E

D

J.

J

O H

N S

O N

D . W

Y A

TT

K

LH

A N

N

IS

TO

N

A R

M Y

D E

P O

T, A

LA

B

A M

A 7.

M

W G

E N

E R

A

TI

O N

P

LA

N T

FY

E R

C

IP

A T

A N

N

IS

TO

N

A R

M Y

D E

P O

T gr ou p E ng in ee ri ng a nd T ec hn ic al

S ol ut io ns

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

M O

B

IL

E D

IS

TR

IC

T

M O

B

IL

E, A

LA

B

A

A

D E

S C

R

IP

TI

O

N M

A R

K D

A

TE

US Army Corps of Engineers

SHEET ID

S O

LI

C

IT

A

TI

O

N N

O

D E

S

IG

N E

D B

Y

S

IZ

E

S U

B M

IT

TE

D B

Y

C O

N

TR

A C

T N

O

A N

S I D

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

TE

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9

P R

O

JE

C T

N U

M B

E R

FI

LE

N A

M E

A U

G U

S T

- - M B

Y

R . W

E E

D

J.

J

O H

N S

O N

D . W

Y A

TT

K

LH

A N

N

IS

TO

N

A R

M Y

D E

P O

T, A

LA

B

A M

A 7.

M

W G

E N

E R

A

TI

O N

P

LA

N T

FY

E R

C

IP

A T

A N

N

IS

TO

N

A R

M Y

D E

P O

T gr ou p E ng in ee ri ng a nd T ec hn ic al

S ol ut io ns

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

M O

B

IL

E D

IS

TR

IC

T

M O

B

IL

E, A

LA

B

A M

A

U

TI

LI

TY

P

LA

N

M B

Y

1C

U

1.

D

W G

CU101

M-301

E

C H

A N

I C

L

T

A I L

S

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D E

S C

R I P

T I O

N M

A R

K D

A T

E

US Army Corps of Engineers

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

S I Z

E

S U

B M

I T

T E

D

B

Y

C O

N T

R A

C T

N

O

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

P R

O J E

C

U M

B E

R

F I L

M

E

U S

R M

Y

C

O R

P

O

F

E

N G

I N

E E

R S

M O

B I L

E

D

I S

T R

I C

T

M O

B I L

E

A

L A

B A

M A

SHEET ID

A N

S I

D

K L H

J P

G

J P

G

J P

G

A N

N I S

T O

N

A

R M

Y

D

E P

O T

A

L A

B A

M A

W

G

E N

E R

A T

I O

N

P

L A

N T

F Y

C

I

A

N N

I S

T O

N

A

R M

Y

D

E P

O T gr ou p E ng in ee ri ng a nd T ec hn ic al

S ol ut io ns

A U

G U

M B

Y

M B

Y M d w g

FLORIDA LICENSE NUMBER 05371

P: 850-438-0050 F: 850-432-8631

SCG project: 2019-127

SCHMIDT

CONSULTING GROUP,INC.

901 W. Garden St. Pensacola, FL 32502

JOHN PAUL GIBBS P.E.

FLORIDA LICENSE NUMBER 60089

A M

E N

D

R

E V

I S

T

A I L

M

A

AutoCAD SHX Text

4"X4"X1/4" ANGLE ANCHORED TO STRUCTURE WITH 3/8"X3" EXPANSION BOLTS

AutoCAD SHX Text

WELD BOTH SIDES (TYPICAL)

AutoCAD SHX Text

1-5/8" P-3300 GALVANIZED "UNISTRUT" OR EQUAL

AutoCAD SHX Text

RUN INSULATION OF SUCTION LINE THRU CLAMP ASSEMBLY

AutoCAD SHX Text

SECURE REFRIGERANT PIPING TO SUPPORTS WITH "UNISTRUT" PIPE CLAMP OR EQUAL

AutoCAD SHX Text

SEAL AROUND ALL OPENINGS WITH SILICONE SEALANT. COLOR TO MATCH BUILDING.

AutoCAD SHX Text

16 GAUGE GALV. SLEEVE

AutoCAD SHX Text

SUCTION LINE

AutoCAD SHX Text

NOTE: LIQUID LINE SIMILAR.

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

REFRIGERANT PIPE

AutoCAD SHX Text

SUPPORT AT WALL DETAIL

AutoCAD SHX Text

1-5/8" P-1000 "UNISTRUT" CHANNEL OR EQUAL (TYPICAL)

AutoCAD SHX Text

INSULATE AROUND ALL SUCTION LINES BENEATH CLAMP ASSEMBLY (TYPICAL)

AutoCAD SHX Text SECURE REFRIGERANT PIPING TO CHANNEL WITH "UNISTRUT" PIPE CLAMP OR EQUAL (TYPICAL)

AutoCAD SHX Text NOTES: 1. PREP AND PAINT CHANNEL AFTER CUTTING AND BEFORE INSTALLATION PREP AND PAINT CHANNEL AFTER CUTTING AND BEFORE INSTALLATION 2. SUPPORT CHANNEL FROM STRUCTURE ABOVE SUPPORT CHANNEL FROM STRUCTURE ABOVE 3. PROVIDE SUPPORT PER PROJECT SPECIFICATIONS AND WITHIN 6" OF ANY ELBOWPROVIDE SUPPORT PER PROJECT SPECIFICATIONS AND WITHIN 6" OF ANY ELBOW

AutoCAD SHX Text

3/8" THREADED ROD (TYPICAL)

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

OVERHEAD INTERIOR REFRIGERANT

AutoCAD SHX Text

PIPE SUPPORT DETAIL

AutoCAD SHX Text

LOCKNUT AND WASHER (TYPICAL)

AutoCAD SHX Text

PIPE FULL SIZE OF UNIT DRAIN CONNECTION

AutoCAD SHX Text

DRAIN PAN

AutoCAD SHX Text

SLOPE TOWARD HUB DRAIN

AutoCAD SHX Text

NOTE 2

AutoCAD SHX Text 2"

AutoCAD SHX Text NOTE: 1. LOCATE TRAPS AND DRAIN SO AS TO BE ACCESSIBLE FOR CLEANING. LOCATE TRAPS AND DRAIN SO AS TO BE ACCESSIBLE FOR CLEANING. 2. HEIGHT SHALL BE EQUAL TO AIR UNIT TOTAL STATIC PRESSURE IN INCHES HEIGHT SHALL BE EQUAL TO AIR UNIT TOTAL STATIC PRESSURE IN INCHES WATER COLUMN PLUS ONE INCH. (TSP+1 IN W.G.) 3. PROVIDE AIR GAP BETWEEN HUB DRAIN AND CONDENSATE DRAIN EQUAL TO PROVIDE AIR GAP BETWEEN HUB DRAIN AND CONDENSATE DRAIN EQUAL TO TWO TIMES THE DRAIN DIAMETER.

AutoCAD SHX Text

HAND-TIGHT PLUG

AutoCAD SHX Text

NOTE 3

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

CONDENSATE DRAIN TRAP DETAIL

AutoCAD SHX Text

4'-0" MINIMUM

AutoCAD SHX Text 12"

AutoCAD SHX Text 12"

AutoCAD SHX Text

CAST IRON COVER WITH 1" DIAMETER LIFT HOLE

AutoCAD SHX Text

DRAIN PIPE

AutoCAD SHX Text

24" INSIDE DIAMETER CONCRETE, BELL AND SPIGOT JOINT

AutoCAD SHX Text

FILL WELL WITH 2" TO 3" GRAVEL OR CRUSHED STONE WITH NO FINES

AutoCAD SHX Text

GRADE

AutoCAD SHX Text 34640

AutoCAD SHX Text

AutoCAD SHX Text

DRY WELL DETAIL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text NOTES: 1. MOUNT UNIT PER MANUFACTURER SPECIFICATIONS AND MINIMUM INSTALLATION MOUNT UNIT PER MANUFACTURER SPECIFICATIONS AND MINIMUM INSTALLATION CLEARANCES. 2. INSTALL ACCORDING TO ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL, INSTALL ACCORDING TO ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL, MECHANICAL AND BUILDING CODES. 3. CONDENSATE LINE AND POWER LINE SHOWN OFFSET FOR CLARITY.CONDENSATE LINE AND POWER LINE SHOWN OFFSET FOR CLARITY.

AutoCAD SHX Text

WALL MOUNTED UNIT

AutoCAD SHX Text

REFRIGERANT LINE FLARED CONNECTION

AutoCAD SHX Text

CONDENSATE DRAIN LINE. INSULATE PER SPECIFICATIONS.

AutoCAD SHX Text

POWER AND CONTROL WIRING (HIGH VOLTAGE)

AutoCAD SHX Text

SERVICE VALVES

AutoCAD SHX Text

INSULATION

AutoCAD SHX Text

WEATHERPROOF FUSED DISCONNECT PER NEC. COORDINATE WITH ELECTRICAL.

AutoCAD SHX Text

OUTDOOR UNIT

AutoCAD SHX Text

REFER TO MANUFACTURER FOR MAXIMUM REFRIGERANT LINE LENGTH

AutoCAD SHX Text

INDOOR UNIT

AutoCAD SHX Text

WALL PIPE HOLE SLEEVE. SEAL WATER TIGHT.

AutoCAD SHX Text

EXTERIOR WALL

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

DUCTLESS HPU - INDOOR (WALL MOUNT)

AutoCAD SHX Text

AND OUTDOOR UNIT DETAIL

AutoCAD SHX Text

TYP.

AutoCAD SHX Text L3x3x 14

AutoCAD SHX Text (2)PL x4'-4"x8"12x4'-4"x8"

AutoCAD SHX Text

(2) PL x4'-0"x8"12x4'-0"x8"

AutoCAD SHX Text

(4) 5/8" A307 STAINLESS 5/8" A307 STAINLESSSTEEL BOLT AND GASKETED WASHER.

AutoCAD SHX Text

6'-0" AFF

AutoCAD SHX Text

COMPOSITE METAL WALL

AutoCAD SHX Text

GIRT

AutoCAD SHX Text

36" CLEARANCE

AutoCAD SHX Text 14"

AutoCAD SHX Text

REFRIGERANT SUCTION AND LIQUID LINES W/ ALUMINUM JACKET

AutoCAD SHX Text

OUTDOOR CONDENSING UNIT

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

WALL MOUNTED CONDENSING UNIT DETAIL

AutoCAD SHX Text

CLEARANCE

AutoCAD SHX Text SCHEDULE 40 STEEL PIPE SLEEVE OF SUFFICIENT DIAMETER TO FIT REFRIGERANT LINES. SEAL SPACE AROUND PIPING W/ EXPANDING POLYURETHANE FOAM SEALANT.

AutoCAD SHX Text 3/16

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BOLT TO ANGLE IRON WITH 1/2" BOLT,NUT, AND WASHERS.

AutoCAD SHX Text

A602

A503

A403

A304

A701

A601

A502

A402

A303

A501

A401

A302

A202 244 246

A301

A201

A102

443B

243A101

419G

248 500 499 135

162L

162AF

162M 162T

162P 162F 162U 162C

162AD

162AB 162

154A

153C

100 123

488 102

104 105

153A

153G 153D

138A

506A

107 413 428

114 145

402B 116 402A

421 431

458 401 401A

121 122

456 459

430 247 170

410AF

141 423

462 463 457 448 455

410E

133 134

265M

149 129A 226 229 234

505A

524A

524 192 466A

447B 447A

522 142 137

419 519

265P

414A

AREA 8 AREA 7

AREA 9

AREA 6 AREA 5

AREA 1 AREA 4AREA 3AREA 2

AREA 10

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

M

AR

K D

AT

E

US Army Corps of Engineers

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

SI

ZE

SU

BM

IT

TE

D B

Y:

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

U M

BE

R

FI

LE

N

AM

E:

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

M O

B

IL

E D

IS

TR

IC

T

M O

B

IL

E, A

LA

B

A M

A

SHEET ID

AN

SI

D

KL

H

KL

H

, J W

, T B

EW

H

KL

H

AN

N

IS

TO

N A

R M

Y D

EP

O

T, A

LA

BA

M A

7.

M W

G

EN

ER

AT

IO

N

P

LA

N T

FY

E R

C

IP

A T

AN

N

IS

TO

N A

R M

Y D

EP

O

T gr ou p E ng in ee ri ng a nd T ec hn ic al

S ol ut io ns

AU

G

U

ST

M

BY

O

VE

R

VI

EW

M

BY

1E -1

.D

W G

E-150

EQ

U

IP

M

EN

T

LO

C

AT

IO

N S

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text

RECLOSER R203-B

AutoCAD SHX Text

RECLOSER R203-A

AutoCAD SHX Text

RECLOSER R202-2B

AutoCAD SHX Text

RECLOSER R202-1A

AutoCAD SHX Text

RECLOSER R202-1B

AutoCAD SHX Text

RECLOSER R202-2A

AutoCAD SHX Text

%%U OVERALL SITE PLAN - EQUIPMENT LOCATIONS

AutoCAD SHX Text

APPROX SCALE: 1"=200'-0"

AutoCAD SHX Text

1. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING SITE CONDITIONS. ANY EXISTING BURIED OR OVERHEAD UTILITY SYSTEMS IN DIRECT CONFLICT WITH PROPOSED SITE IMPROVEMENTS SHALL BE RELOCATED BY THE CONTRACTOR. 2. PROPER CARE SHALL BE TAKEN TO ENSURE PROPER CARE SHALL BE TAKEN TO ENSURE CONTINUOUS CONTINUITY OF ALL UTILITY SYSTEMS. ALL SYSTEM DISRUPTIONS SHALL BE SCHEDULED AND APPROVED IN WRITING PRIOR TO DISCONNECTING. ANY DAMAGED UTILITY SYSTEMS SHALL BE REPAIRED AND/OR REPLACED IMMEDIATELY AT THE CONTRACTORS EXPENSE. 3. SEE GENERAL ELECTRICAL NOTE 14, SHEET E-003. SEE GENERAL ELECTRICAL NOTE 14, SHEET E-003. 4. FEEDERS ARE EXISTING. INSTALL RECLOSERS IN-LINE FEEDERS ARE EXISTING. INSTALL RECLOSERS IN-LINE WITH EXISTING DISTRIBUTION. * SEE SHEET E-902 SEE SHEET E-902 * SEE SHEET E-903 SEE SHEET E-903 5. THE BASE DISTRIBUTION LINES (FEEDER 202 AND 203) THE BASE DISTRIBUTION LINES (FEEDER 202 AND 203) AS SHOWN ON SHEETS E-151 THRU E-160 ARE EXISTING AND AS INDICATED ON SHEETS E-902 AND E-903. ALL TRANSFORMERS AND SECONDARY SERVICES ARE EXISTING TO REMAIN. INSTALL NEW RECLOSERS IN THE EXISTING DISTRIBUTION SYSTEM AS INDICATED ON SHEETS E-151 THRU E-160, E-902 AND E-903. 6. EXISTING POLE MOUNTED TRANSFORMERS MAY BE EXISTING POLE MOUNTED TRANSFORMERS MAY BE NOTED FOR TOTAL kVA CAPACITY AT THAT LOCATION. FOR EXAMPLE, 3-50kVA UNITS MAY BE NOTED 150kVA. THIS IS FOR INFORMATION ONLY.

AutoCAD SHX Text

SHEET NOTES

AutoCAD SHX Text 200'

AutoCAD SHX Text 100'

AutoCAD SHX Text 0'

AutoCAD SHX Text 200'

AutoCAD SHX Text

SCALE: 1" = 200'

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AMEND 0001, ADDED SHEET NOTES

APR 2021

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

M

AR

K D

AT

E

US Army Corps of Engineers

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

SI

ZE

SU

BM

IT

TE

D B

Y:

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

U M

BE

R

FI

LE

N

AM

E:

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

M O

B

IL

E D

IS

TR

IC

T

M O

B

IL

E, A

LA

B

A M

A

SHEET ID

AN

SI

D

KL

H

KL

H

, J W

, T B

EW

H

KL

H

AN

N

IS

TO

N A

R M

Y D

EP

O

T, A

LA

BA

M A

7.

M W

G

EN

ER

AT

IO

N

P

LA

N T

FY

E R

C

IP

A T

AN

N

IS

TO

N A

R M

Y D

EP

O

T gr ou p E ng in ee ri ng a nd T ec hn ic al

S ol ut io ns

AU

G

U

ST

M

BY

M

BY

1E -8

.d wg

E-802

TY

PI

C

AL

P O

W

ER

P

LA

N T

L O

AD

B

AN

K

D

ET

AI

L

AutoCAD SHX Text

SIDE VIEW

AutoCAD SHX Text

GRADE

AutoCAD SHX Text

CONCRETE PAD SEE STRUCTURAL

AutoCAD SHX Text

FA

AutoCAD SHX Text X1

AutoCAD SHX Text H1

AutoCAD SHX Text

GND

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text

(SKID MOUNTING HOLES)

AutoCAD SHX Text

KVA:

AutoCAD SHX Text

HIGH VOLTAGE:

AutoCAD SHX Text

LOW VOLTAGE:

AutoCAD SHX Text

HV TAPS:

AutoCAD SHX Text

HV-KV BIL:

AutoCAD SHX Text

LV-KV BIL:

AutoCAD SHX Text

PHASE:

AutoCAD SHX Text

FREQ-HZ:

AutoCAD SHX Text

TEMP RISE-°C:

AutoCAD SHX Text

COOLING CLASS:

AutoCAD SHX Text

INSULATION CLASS:

AutoCAD SHX Text

WINDING COND:

AutoCAD SHX Text

PAINT/COATING:

AutoCAD SHX Text

APPRX WT-LBS:

AutoCAD SHX Text

AutoCAD SHX Text

12,470 DELTA

AutoCAD SHX Text 480Y/277

AutoCAD SHX Text 2A2B 2 1/2%%%

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AA

AutoCAD SHX Text 220°C

AutoCAD SHX Text

COPPER

AutoCAD SHX Text

ANSI 61 GRAY

AutoCAD SHX Text 14500

AutoCAD SHX Text

%%UTRANSFORMER SECTION

AutoCAD SHX Text

%%ULOAD BANK SECTION

AutoCAD SHX Text

CONDUIT STUB-UP AREA

AutoCAD SHX Text 2,500kW

AutoCAD SHX Text 2,875kW

AutoCAD SHX Text

HV BUS CONNECT

AutoCAD SHX Text

HV BUS CONNECT

AutoCAD SHX Text Y

AutoCAD SHX Text

FROM SWITCHGEAR

AutoCAD SHX Text

PP-N1

AutoCAD SHX Text G

AutoCAD SHX Text

ROD

AutoCAD SHX Text

ROD

AutoCAD SHX Text

ROD

AutoCAD SHX Text

ROD

AutoCAD SHX Text

ROD

AutoCAD SHX Text

ROD

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text

#1/0 CU GRD TO LOADBANK

AutoCAD SHX Text

#1/0 CU GRD TO TRANSFORMER SEC

AutoCAD SHX Text

#1/0 CU GRD TO GRD LUG

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text

#6 CU GRD TO CONCRETE PAD REINFORCEMENT

AutoCAD SHX Text

GRD ROD: 3/4" X 20'-0" (TYP)

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

TO REMOTE CONTROL

AutoCAD SHX Text

PANEL

AutoCAD SHX Text

12,470V, 3 PH.

AutoCAD SHX Text

TB

AutoCAD SHX Text

MDP-20

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BASE BID

AutoCAD SHX Text

CONCRETE PAD 5' X 23'

AutoCAD SHX Text

TB

AutoCAD SHX Text 3#2/0(15kV) & 1#2/0(600V)-5"C

AutoCAD SHX Text

1-5"C SPARE

AutoCAD SHX Text

MAIN CIRCUIT BREAKER

AutoCAD SHX Text

SECTION

AutoCAD SHX Text

CABLE TERMINATORS

AutoCAD SHX Text

MDP-26 (CONTROL POWER)

AutoCAD SHX Text

2#10 & 1#10(GRD)-1"C

AutoCAD SHX Text 480Y/277V

AutoCAD SHX Text

SECONDARY MAIN CIRCUIT BREAKER

AutoCAD SHX Text

TYPICAL POWER PLANT LOAD BANK DETAILS

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

SHEET NOTES

AutoCAD SHX Text

KEYED NOTES

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text E802

AutoCAD SHX Text

1. THIS DETAIL SHEET IS TYPICAL AND THIS DETAIL SHEET IS TYPICAL AND DIMENSIONS SHOWN ARE APPROXIMATE. CONTRACTOR SHALL USE EXACT DIMENSIONS OF MANUFACTURER SHOP DRAWINGS. 2. ALL PATHWAY RACEWAYS TO AND IN ALL PATHWAY RACEWAYS TO AND IN SUPPORT OF THE LOAD BANK SHALL BE PROVIDED IN BASE BID, STUBBED UP AND CAPPED. INSTALL ALL WIRING, EQUIPMENT AND DEVICES IN BID OPTION.

AutoCAD SHX Text

(BID OPTION)

AutoCAD SHX Text

SINGLE LINE DIAGRAM

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text A

AutoCAD SHX Text E802

AutoCAD SHX Text

FOUNDATION PLAN

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text B

AutoCAD SHX Text E802

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

120V, 30A CIRCUIT (HEATER)

AutoCAD SHX Text

* 2#8 &1#8(GRD)-1"C

AutoCAD SHX Text

LOAD BANK COOLING FANS TO BE POWERED BY INTERNAL POWER SOURCE.

AutoCAD SHX Text REMOTE CONTROL PANEL TO BE LOCATED IN SWITCHGEAR BUILDING. SEE SHEET E-203 FOR PLACEMENT IN BUILDING. * 1 1/2" CONDUIT 1 1/2" CONDUIT * PROVIDE ALL CONTROL WIRING PROVIDE ALL CONTROL WIRING PER MANUFACTURER

AutoCAD SHX Text C

AutoCAD SHX Text E-402

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AMEND 0001, ADDED SHEET NOTE

APR 2021

1 MBY20001C-001 - AMEND 0001
Sheets and Views
C-001
1 MBY20001CU101 - AMEND 0001
Sheets and Views
CU101
2 MBY20001A-101 - AMEND 0001
2 MBY20001A-601 - AMEND 0001
3 MBY20001MP-201 - AMEND 0001
4 MBY20001M-301- AMEND 0001
5 MBY20001E-150 - AMEND 0001
Sheets and Views
E-150
5 MBY20001E-802 - AMEND 0001
Sheets and Views
Layout1
5 MBY20001T-100 - AMEND 0001
5 MBY20001T-506 - AMEND 0001

File details come from the government source that posted it. Updated .