Technical_Exhibit_B_-_Drawings.pdf
PDF 2 MB Posted
- Attached to
- Replace Air Handler Federal contract opportunity
- Solicitation number
- W91151-19-B-0035
About this file
Technical Exhibit B - Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| KO_RELEASED_AMENDMENT_P00001_SOLICIT-19-B-0035-REPLC_AHU_IN_BUILD_91019-FHTX-15AUG19.pdf | ||
| TECH_EXHIBIT_C_-_REVISED_DRAWING_(S_MOD_1)-_19-B-0035-REPLC_AHU_IN_BUILD_91019-FHTX-15AUG19.pdf | ||
| Attachment_1-Appendix_A_04-Aug-2016.pdf | ||
| Solicitation_19-B-0035_Replace_Air_Handler_7_24__2019.pdf | ||
| Technical_Exhibit_A_-_Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET
N
1"=200’
INDEX OF DRAWINGS
HWY 84
HWY 84
HWY 36
F .M
RES.BD.
RES.BD.
R E S . B
D
RES. BD.
R E
S .B
D
KILLEEN
CANTONMENT
AREA
WEST
FORT
HOOD
GATESVILLE
NORTH
FORT
HOOD
RESERVATION
BELTON
LAKE
COPPERAS
COVE
HWY190
HWY190
FORT HOOD AREA MAP
O L
D G
E O
R G
E T
O W
N R
D
E A
S T R
A N
G E R
D
N O
LA
N R
D
FORT HOOD
W E S
T R
A N
G E R
D
C L
A R
K E R
D
H W
Y
35 37
LOCATION
PROJECT
LAREDO
CORPUS
CHRISTI
HOUSTON
AUSTIN
KILLEEN
WACO
FORT WORTH DALLAS
FORT
SMITH
OKLAHOMA
CITY
TULSA
AMARILLO
ALBUQUERUE
SANTA FE
VICINITY MAP
LOUISIANA
MEXICO
MEXICO
TEXAS
ARKANSAS
NEW
MEXICO
ELPASO
OKLAHOMA
GULF OF
SAN ANTONIO
FORT HOOD
WICHITA FALLS
N
SCALE IN MILES
1/2 1
FORT HOOD MILITARY RESERVATION
N
0 100 200
SCALE IN MILES
N
0 5 10
SCALE IN MILES
NORTH SYMBOL
GENERAL SYMBOLS
REVISION NUMBER
WALL TYPE MARK
DOOR MARKWINDOW MARK
DETAIL NUMBER
REFERENCE FROM
REFERENCE TO
G-101
C O
V E
R S
H E
E T
REPLACE AHU
FORT HOOD,TEXAS
FORT HOOD DIRECTORATE OF PUBLIC WORKS-ENGINEERING DIVISION
NOTE BY SYMBOL
SHEET DESCRIPTION
A
A
N
A
A
BUILDING LEGEND (POINTS OF INTEREST)
PROJECT SITE
BUILDING 4612 (DIRECTORATE OF PUBLIC WORKS)
WEST FORT HOOD
C L E
A R C
R E
E K
US HIGHWAY 190
CENTRAL
TEXAS
COLLEGE
US HIGHWAY 190
PERSHING PARK
VENABLE VILLAGE
H W
Y
CHAFFEE VILLAGE
PATTON
PARK
Santa Fe Av e
WAREHOUSE AVE
62ND
RAIL HEAD
W R
A T
T E
N
C L
A R
K E R
O A
D
MONTAGUE VILLAGE
TO
WEST
FT.HOOD
LIBERTY VILLAGE
BUSINESS ROUTE 190
H W
Y
B A S
E R
D
W
AR
EH
O
U
SE
AVE
MOHAWK RD
G R
E Y D
R
PROJECT NO: AD005235P
B P
R E
S S
E R
HOT-WATER SYSTEM CONTROLSM-702
CONTROLS
AIR-DELIVERY & COOLING SYSTEMSM-701
MECHANCIAL SCHEDULESM-601
MECHANICAL DETAILSM-501
ENLARGED MECHANICAL ROOM PLANSM-102
EXISTING MECHANICAL PLANM-101
MECHANICAL NOTESM-001
COVER SHEETG-101
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E O
F
A B C D E F
D a te
D e s c ri p ti o n
DPW
FORT HOOD TEXAS
D ir ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/3
/2
:2
:1
P
M G E
N G
S
V C \P ro j\
A D
P B
R
E P
L A
C E A
H U \F lo o rp la n s
D e s ig n \G -1
C o v e r S h e e t.
d g n
R E
P L
A C
E A
H U
91019
AD005235P
B P
R E
S S
E R
-A
P R -2
NEW
R
OBERT
GRAY
DR
N E
W R
O B
E R
T G
R A
Y
R
GRAY D
G R
A Y
INNER FENCE RD
n oi siviD gnire en i g n E
91030 91053
91054
90033
91016
91017
91029
91018
91019
90031
91023
91020
91021 91022
M E
C H
A N
IC
A L N
O T
E S
M-001
B P
R E
S S
E R
ELECTRICAL NOTES:
MECHANICAL NOTES:
GENERAL NOTES:
UNTIL REUSED.
ITEMS INTENDED FOR REUSE ON THIS PROJECT SHALL REMAIN IN THE POSSESSION OF THE CONTRACTOR5.
OF THE CONTRACTOR, WHO SHALL BE RESPONSIBLE FOR ITS DISPOSAL.
UNLESS NOTED OTHERWISE, ALL MATERIAL REMOVED AND NOT REUSED SHALL BECOME THE PROPERTY4.
PENETRATIONS WHEREVER MECHANICAL, PLUMBING, OR ELECTRICAL WORK OCCURS.
CONSTRACTOR SHALL PROVIDE PATCHING, CLOSURE, AND FINISHING OF ADJACENT SURFACES AND3.
TO PERFORMING ANY MATERIAL TAKE-OFFS AND PRIOR TO CONSTRUCTION.
ALL DIMENSIONS SHOWN ARE APPROXIMATE. CONTRACTOR SHALL FIELD-VERIFY ALL DIMENSIONS PRIOR2.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXISTING SITE CONDITIONS.1.
BACK TO THE EXISTING ELECTRICAL PANEL. ALL NEW EQUIPMENT SHALL FEATURE NEW WIRING.
ALL EXISTING ELECTRICAL WIRING ASSOCIATED WITH DEMOLISHED EQUIPMENT SHALL BE DEMOLISHED2.
AND BE LABELED AS "SPARE".
DEMOLISHED. ANY BREAKERS THAT ARE NOT REUSED SHALL REMAIN IN THE EXISTING ELECTRICAL PANEL
EQUIPMENT IF THEY ARE APPROPRIATELY SIZED. ANY CONDUIT THAT IS NOT REUSED SHALL BE
EXISTING ELECTRICAL CONDUIT AND CIRCUIT BREAKERS SHALL BE PRESERVED AND REUSED FOR NEW1.
EQUIPMENT AND DUCTWORK IN THE MECHANICAL ROOM.
CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING, ADJUSTING, AND BALANCING (TAB) ALL NEW HVAC5.
JACKETING.
INSULATED PER SPECS (23 23 00). ALL EXTERIOR REFRIGERANT PIPING SHALL FEATURE ALUMINUM
ALL NEW REFRIGERANT PIPING SHALL BE INSTALLED PER THE MANUFACTURER’S INSTRUCTIONS AND4.
ALL NEW HOT-WATER PIPING SHALL BE INSTALLED AND INSULATED PER SPECS (23 05 15).3.
INSULATED PER SPECS (23 07 00).
COMBINATION OF AS-BUILT INFORMATION AND ON-SITE MEASUREMENTS. ALL NEW DUCTWORK SHALL BE
SPECS (23 00 00). ALL INDICATED DUCTWORK DIMENSIONS ARE APPROXIMATE AND REPRESENT A
WHERE NECESSARY, CONTRACTOR SHALL INSTALL NEW DUCTWORK PER SMACNA 3RD EDITION AND2.
AND REUSED FOR THE MODIFIED HVAC SYSTEM.
UNLESS NOTED OTHERWISE, ALL EXISTING DIFFUSERS, GRILLES, AND DUCTWORK SHALL BE PRESERVED1.
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/3
/2
:2
:1
P
M G E
N G
S
V C \P ro j\
A D
P B
R
E P
L A
C E A
H U \F lo o rp la n s
D e s ig n \M
-0 .d g n
R E
P L
A C
E A
H U
91019
AD005235P
B P
R E
S S
E R
-A
P R -2 n oi siviD gnire en i g
M-101 0 4 8
SCALE (FEET)
SCALE: 3/16" = 1’
KEY NOTES:
GENERAL NOTES:
M
M
B P
R E
S S
EXISTING MECHANICAL PLAN
P L
A N
E X
IS
T
IN
G M
E C
H A
N
IC
A L
EXISTING THERMOSTAT SERVING AHU-1 TO BE REPLACED.
N
M-702.
MECHANICAL ROOM AND HAVE ALL OF THE CAPABILITIES DESCRIBED IN M-701 AND
BE WIRED TO THE NEW DIRECT DIGITAL CONTROL (DDC) CONTROLLER IN THE
A NEW, WALL-MOUNTED, LONWORKS-COMPLIANT THERMOSTAT. THIS DEVICE SHALL
CONTRACTOR SHALL REPLACE THE EXISTING THERMOSTAT SERVING AHU-1 WITH2.
DESIGN AIRFLOWS ARE PROVIDED FOR REFERENCE PURPOSES ONLY.
DIFFUSER AND RETURN GRILLE ONCE ALL NEW HVAC EQUIPMENT IS INSTALLED.
EXISTING DUCTWORK SYSTEM STATING THE MEASURED AIRFLOWS AT EACH SUPPLY
CONTRACTOR SHALL SUBMIT A PARTIAL TAB REPORT FOR THE BUILDING’S1.
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/3
/2
:2
:2
P
M G E
N G
S
V C \P ro j\
A D
P B
R
E P
L A
C E A
H U \F lo o rp la n s
D e s ig n \M
-1 .d g n
R E
P L
A C
E A
H U
91019
AD005235P
B P
R E
S S
E R
-A
P R -2
T
C
C
D
C
C
C
C
B
B
A
A
A
A
A
A
C
A
A
A
D
SPLITTER DAMPER
DAMPER
SPLITTER
10’’ x 10’’ 12’’ x 12’’
10’’ x 10’’ 12’’ x 12’’
10’’ x 10’’ 12’’ x 12’’
30’’ x 12’’
7’’ x 6’’
7’’ x 6’’ 7’’ x 6’’ x
7’’ x 6’’ 7’’ x 6’’
7’’ x 6’’
14’’ x 12’’
22’’ x 20’’
15’’ x 12’’ x
8’’ x 8’’
8’’ x 8’’
8’’ x 8’’ x x
LEGEND:
T EXISTING THERMOSTAT
EXISTING ROOF-MOUNTED EXHAUST FAN
EXISTING 1’ X 1’ SUPPLY DIFFUSER
EXISTING 2’ X 2’ SUPPLY DIFFUSER
n oi siviD gnire en i g
SCALE: 1/2" = 1’
20 4
SCALE (FEET)
B P
R E
S S
E R
KEY NOTES:
GENERAL NOTES:
N
DUCTWORK
PIPING
ENLARGED MECHANICAL ROOM PLANS
R O
O M P
L A
N S
E N
L A
R G
E D M
E C
H A
N
IC
A L
M-102101 M
M
EQUIPMENT LIST
AHU-1
SYMBOL DESCRIPTION
WH-1
AIR-HANDLING UNIT
CU-1 CONDENSING UNIT
EF-1 EXHAUST FAN
HWP-1 HOT-WATER PUMP (NOT SHOWN)
WATER HEATER
CONTRACTOR SHALL REATTACH THE EXISTING FLUE TO WH-1.
NEW DDC CONTROLLER IN A NEMA 1 ENCLOSURE. SEE M-701 FOR DETAILS.
DESCRIBED IN M-702.
BE WIRED TO THE NEW DDC CONTROLLER AND HAVE ALL OF THE CAPABILITIES
CONTRACTOR SHALL INSTALL A NEW OUTSIDE-AIR (OA) SENSOR. THIS DEVICE SHALL8.
ENCLOSURES, RESPECTIVELY.
AND CU-1. THESE DISCONNECTS SHALL BE PROTECTED BY NEMA 1 AND NEMA 3R
CONTRACTOR SHALL REPLACE THE EXISTING ELECTRICAL DISCONNECTS FOR AHU-17.
UNDERSIZED.
EXISTING PADS MAY BE REUSED, HOWEVER, THEY SHALL BE EXPANDED IF THEY ARE
AHU-1 AND CU-1 SHALL BE INSTALLED ON FORMED-AND-PLACED CONCRETE PADS.6.
SCREEN AT ITS DISCHARGE END. SEE M-504 FOR MORE DETAILS.
CONDENSATE DRAIN IN THE MECHANICAL ROOM. THIS PIPING SHALL FEATURE A BUG
CONTRACTOR SHALL RUN NEW CONDENSATE PIPING FROM AHU-1 TO THE NEAREST5.
PROTECTIVE SLEEVE SHALL BE INSTALLED PER SPECS (23 05 15).
AND CU-1. EXISTING WALL PENETRATIONS SHALL BE REUSED, BUT A NEW
CONTRACTOR SHALL REPLACE ALL EXISTING REFRIGERANT PIPING BETWEEN AHU-14.
ROOM PER SPECS (23 07 00).
CONTRACTOR SHALL REINSULATE ALL EXISTING DUCTWORK IN THE MECHANICAL3.
SYSTEM ACCESSORIES.
AND REUSED FOR THE NEW HVAC SYSTEM, AS WELL AS ALL EXISTING HOT-WATER
EXISTING WATER HEATER (WH-1) AND IN-LINE PUMP (HWP-1) SHALL BE PRESERVED2.
DETAILS.
NECESSARY TO INSTALL NEW EQUIPMENT. SEE M-601 FOR SIZING AND CAPACITY
SYSTEM AS SHOWN. EXISTING PIPING CONNECTED TO AHU-1 MAY BE REPLACED AS
SYSTEM SHALL BE CONNECTED TO THE BUILDING’S EXISTING HOT-WATER PIPING
CONDENSING UNIT (CU-1) SERVING BUILDING 91019 WITH A NEW SPLIT SYSTEM. THIS
CONTRACTOR SHALL REPLACE THE EXISTING AIR-HANDLING UNIT (AHU-1) AND1.
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/3
/2
:2
:2
P
M G E
N G
S
V C \P ro j\
A D
P B
R
E P
L A
C E A
H U \F lo o rp la n s
D e s ig n \M
-1 .d g n
R E
P L
A C
E A
H U
91019
AD005235P
B P
R E
S S
E R
-A
P R -2
GRILLE
OUTSIDE-AIR
24" x 24"
EXISTING CONCRETE PAD
x x
AHU
EF
12’’ x 24’’ 12’’ x 24’’
PLENUM
MIXED-AIR
24" x 24"
GRILLE
RETURN-AIR
GRILLE
RETURN-AIR
AHU
WH
CU
EXISTING CONCRETE PAD
EXISTING CONCRETE PAD
FD
EXISTING FLUE TO ROOF
LEGEND:
FD
EXISTING ELECTRICAL PANEL
EXISTING FLOOR DRAIN
EXISTING ELECTRICAL DISCONNECT
EXISTING EXHAUST FAN
n oi siviD gnire en i g
B P
R E
S S
E R
M-501
M E
C H
A N
IC
A L D
E T
A
IL
S
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/3
/2
:2
:3
P
M G E
N G
S
V C \P ro j\
A D
P B
R
E P
L A
C E A
H U \F lo o rp la n s
D e s ig n \M
-5 .d g n
R E
P L
A C
E A
H U
91019
AD005235P
B P
R E
S S
E R
-A
P R -2
NOT TO SCALE
AHU CONDENSATE DRAIN DETAIL
FROM AHU
TO FLOOR DRAIN
SEE NOTE 4
COIL DRAIN BY 2"
VENT EXTENDED ABOVE
N O
T E
S E
E
N O
T E
S E
E
M
M
NOTES:
PROVIDE THREADED PLUG CLEANOUT.4.
LESS THAN 1 1/4".
TO NO LESS THAN 1" BEYOND DISCHARGE OF P-TRAP. SIZE OF LINE IN NO CASE SHALL BE
CONDESATE DRAIN LINE SHALL BE EQUAL TO UNIT CONNECTION SIZE AND MAINTAIN THIS SIZE3.
UNIT OR THE TOTAL POSITIVE STATIC PRESSURE FOR A BLOW-THROUGH UNIT.
LENGTH SHALL BE EQUAL TO 1/2 THE NEGATIVE STATIC PRESSURE FOR A DRAW-THROUGH2.
NEGATIVE OR POSITIVE, OF THE RESPECTIVE UNIT PLUS AN ADDITIONAL 2".
LENGTH SHALL BE EQUAL TO THE STATIC PRESSURE IN INCHES OF WATER GAUGE, BE IT1.
AIR FLOW AIR FLOW
REMOVEABLE #4 SCREEN IN FRAME
ACCESS PANEL
SLOPE BOTTOM TOWARDS LOUVER
WHERE INDICATED
MOTORIZED DAMPER
SEAMS WATERTIGHT)
PLENUM (SEAL ALL JOINTS AND
INSULATED SHEET-METAL
SCREEN
INSECT
#4 MESH
OUTDOOR-AIR LOUVER DETAIL
NOT TO SCALE501
M M
NOTES:
REUSED.
SHALL BE PRESERVED AND
DAMPER. THE EXISTING LOUVER
DAMPER WITH A NEW, MOTORIZED
THE EXISTING OUTSIDE-AIR
CONTRACTOR SHALL REPLACE1.
(SEE NOTE 4)
BRONZE BEARINGS
LIP SEAL
CORNER-WELD FRAME
SLIDE PIN (SEE NOTE 5)
CONTROL SHAFT WITH DAMPER BLADES (6-1/2" WIDE MAX)
16 GA GALVANIZED-STEEL
LEAKAGE
LIP SEALS FOR MINIMUM AIR
FELTED OR NEOPRENE BLADE
ADJACENT BLADES WITH
3/8" INTERLOCK BETWEEN
RETAINERS
PIN WITH LOCK
1/4" TIEBARS WITH
OPPOSED-BLADE DAMPER
PARALLEL-BLADE DAMPER
NOT TO SCALE
LOW-LEAKAGE RECTANGULAR DAMPERS
8" MAX
3 1/2"A
B
A
B
8" MAX
3 1/2"
M
M
NOTES:
WITH 1/2" SLIDE PINS ON END OF BLADES.
SELF-LUBRICATING BRONZE BEARINGS4.
S.S. JAMB TO BLADE WINDSTOP NOT SHOWN.3.
MAXIMUM HEIGHT, B, 72" PER SECTION.2.
MAXIMUM WIDTH, A, 48" PER SECTION.1.
RELIEF-AIR, AND RETURN-AIR DAMPERS.
ALL AIR-HANDLING UNIT OUTSIDE-AIR,
PROVIDE OPPOSED BLADE DAMPERS FOR6.
WITH SLIDE PIN CONTROL.
OR 3/8" SQUARE EXTENDED 6" BEYOND FRAME
CADMIUM-PLATED CONTROL SHAFT 1/2"5.
BOTTOM
BLADE STOPS ON TOP AND
GALVANIZED HAT CHANNEL WITH
FRAME: 3 1/2" X 5/8" X 14 GA
n oi siviD gnire en i g
P
R E
S S
E R
M E
C H
A N
IC
A L S
C H
E D
U L E
S
M-601
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/3
/2
:2
:3
P
M G E
N G
S
V C \P ro j\
A D
P B
R
E P
L A
C E A
H U \F lo o rp la n s
D e s ig n \M
-6 .d g n
R E
P L
A C
E A
H U
91019
AD005235P
B P
R E
S S
E R
-A
P R -2
SYMBOL
PHASE
(HZ)
CYCLE
VOLTAGE
CU-1 2 3 60
TYPE
REFRIGERANT
R-410A 208/230
TYPE
(TONS)
CAPACITY
MIN
BASIS OF DESIGN
14 SEER
SYMBOL
AIR-HANDLING UNIT SCHEDULE
FAN DATA HEATING COIL DATA
AHU-1
TYPE
DX
TYPE
(BTU/H)
CAPACITY
TOTAL
MIN
BASIS OF DESIGN
CONDENSING UNIT SCHEDULE
PHASE
(HZ)
CYCLE
VOLTAGE
3 60 208/230
(CFM)
AIRFLOW
TOTAL
(CFM)
AIRFLOW
OUTSIDE
MIN
HW
GPM
WATER
(°F)
ET
(°F)
LT
COOLING ONLY
EFFICIENCY
MIN
ELECTRIC DATA
STAGES
NUMBER OF
MIN
3,800 120,000 160,000 - 10400 -
10 TRANE TTA12043D
FILTER DATA
(IN)
DEPTH
TYPE
PLEATED (MERV 13) 0.70
PERFORMANCE REQUIRMENTS SHALL BE MET UNDER AHRI CONDITIONS.2.
OR LOUVERED PANELS.
UNIT SHALL FEATURE MANUFACTURER-SUPPLIED COIL PROTECTION, SUCH AS HAIL GUARDS1.
NOTES:
170 TRANE TWE12043B
(BTU/H)
CAPACITY
TOTAL
MIN
COOLING COIL DATA
(IN WC)
SP
EXTERNAL
(FT WC)
DROP
PRESSURE
ELECTRICAL DATA
PERFORMANCE REQUIRMENTS SHALL BE MET UNDER AHRI CONDITIONS.6.
UNIT SHALL FEATURE OPTIONAL EXTERNAL VIBRATION ISOLATORS, IF NOT INTERNALLY ISOLATED.5.
COILS, OR THE MAIN SUPPLY DAMPER.
DIRECTLY CONNECTED TO THE UNIT. IT DOES NOT ACCOUNT FOR THE SUPPLY FAN, THE COOLING AND HEATING
EXTERNAL STATIC PRESSURE (SP) INCLUDES THE EFFECTS OF ALL DUCTWORK AND EQUIPMENT NOT4.
COOLING COIL SHALL FEATURE A STAINLESS STEEL CASING AND A DRAIN PAN.3.
COIL AND FILTER SECTIONS SHALL FEATURE HINGED ACCESS DOORS.2.
SYSTEM.
UNIT SHALL BE A VERTICAL SUPPLY/HORIZONTAL RETURN AIR-HANDLING UNIT INSTALLED AS PART OF A SPLIT1.
NOTES:
n oi siviD gnire en i g
M-701
P
R E
S S
E R
GENERAL NOTES: KEY NOTES:
AHU-1 SHALL FEATURE A HAND-OFF-AUTO SWITCH.
NOT TO SCALE
OCCUPANCY SCHEDULE:
M
M
SYSTEMS:
SEQUENCE OF OPERATION FOR THE AIR-DELIVERY AND COOLING
S Y
S T
E M
S C
O N
T R
O L S
A
IR
-D
E L
IV
E R
Y C
O O
L
IN
G
UNOCCUPIEDHOLIDAYS
UNOCCUPIEDSATURDAY & SUNDAY
0600 - 1800MONDAY - FRIDAY
DDC CONTROLLER SHALL BE PROGRAMMED WITH THE FOLLOWING OCCUPANCY SCHEDULE (ADJ).1.
AIR-DELIVERY & COOLING SYSTEMS CONTROLS
ALARM SYSTEM.
SMOKE DETECTOR SHALL CLOSE, PROVIDING AN ALARM TO THE BUILDING’S FIRE
OPERATING. AT THE SAME TIME, A SET OF NORMALLY-OPEN CONTACTS IN THE
SUPPLY-FAN STARTER CONTROL CIRCUIT SHALL OPEN, PREVENTING THE FAN FROM
DUCTWORK BY A SMOKE DETECTOR, A SET OF NORMALLY-CLOSED CONTACTS IN THE
SMOKE DETECTION: WHEN SMOKE IS SENSED IN EITHER THE SUPPLY OR RETURN7.
PROGRAMMED OCCUPANCY SCHEDULE.
(ADJ) AND 85°F (ADJ), THE HVAC SYSTEM SHALL RETURN TO FOLLOWING THE
SETPOINT (90°F (ADJ)). ONCE THE TEMPERATURE ENTERS THE RANGE BETWEEN 65°F
RANGE BETWEEN THE ST LOW-LIMIT SETPOINT (60°F (ADJ)) AND THE ST HIGH-LIMIT
OCCUPIED MODE IF THE TEMPERATURE IN THE MONITORED SPACE LEAVES THE
NIGHT SETBACK: WHILE IN UNOCCUPIED MODE, THE HVAC SYSTEM SHALL SWITCH TO6.
FOLLOWING THE PROGRAMMED OCCUPANCY SCHEDULE.
TO OCCUPIED MODE FOR ONE HOUR (ADJ). AFTERWARDS, IT SHALL RETURN TO
THAT, WHEN PRESSED, SHALL SWITCH THE HVAC SYSTEM FROM UNOCCUPIED MODE
THE BUILDING’S THERMOSTAT SHALL FEATURE AN OCCUPANCY-OVERRIDE BUTTON5.
THE ST SETPOINT SELECTED BY THE OCCUPANTS.
HEATING ST SETPOINTS. THESE VALUES SHALL BE DETERMINED INTERNALLY USING
DDC CONTROLLER SHALL MAINTAIN A 2°F DEADBAND BETWEEN THE COOLING AND4.
COOLING CIRCUIT EVERY 7 DAYS.
THE BUILDING’S THERMOSTAT. CIRCUITS 1 AND 2 SHALL ALTERNATE AS THE PRIMARY
OCCUPANTS SHALL HAVE THE ABILITY TO ADJUST THE ST SETPOINT +/- 3°F USING
REACHED IN THE MONITORED SPACE, REFRIGERATION CIRCUIT 2 SHALL BE ENABLED.
72°F. IF, AFTER 30 MINUTES OF CONTINUOUS OPERATION, THE ST SETPOINT IS NOT
CIRCUIT SHALL BE UTILIZED TO SATISFY THE SPACE-TEMPERATURE (ST) SETPOINT OF
WHEN COOLING IS REQUIRED, REFRIGERATION CIRCUIT 1 SHALL BE ENABLED. THIS3.
OA DAMPER SHALL BE CLOSED.B.
SUPPLY FAN FOR AHU-1 SHALL BE DISABLED.A.
UNOCCUPIED MODE:2.
DETERMINED BY THE TAB CONTRACTOR.
OUTSIDE-AIR (OA) DAMPER SHALL BE OPENED TO ITS MINIMUM POSITION, ASB.
SUPPLY FAN FOR AHU-1 SHALL BE ENABLED.A.
OCCUPIED MODE:1.
OF OPERATION. ALL COMPONENTS OF THE NEW DDC SYSTEM SHALL BE LONWORKS-COMPLIANT.
CONTRACTOR SHALL PROVIDE ALL CONTROL DEVICES NEEDED TO ACCOMPLISH THE SPECIFIED SEQUENCES4.
CONTRACTOR SHALL INSTALL A NEW DDC PANEL WITH A LONWORKS DISPLAY IN THE MECHANICAL ROOM.3.
NEMA 1 ENCLOSURE.
(H-O-A) SWITCH THAT ALLOWS FOR MANUAL OVERRIDE OF ALL OUTPUTS AND SHALL BE PROTECTED BY A
ACCOMPLISH THE SPECIFIED SEQUENCE OF OPERATION. THIS DEVICE SHALL FEATURE A HAND-OFF-AUTO
CONTRACTOR SHALL INSTALL A NEW, LONWORKS-COMPLIANT DDC CONTROLLER PROGRAMMED TO2.
UNLESS NOTED OTHERWISE.
DEVICES, INCLUDING SENSORS, RELAYS, VALVES, DAMPERS, ACTUATORS, AND PANELS SHALL BE REPLACED, BUILDING 91019 AND ESTABLISH NEW DIRECT DIGITAL CONTROLS (DDC) AS SHOWN. ALL EXISTING CONTROL
CONTRACTOR SHALL DEMOLISH ALL CONTROLS FOR THE EXISTING SPLIT SYSTEM (AHU-1 AND CU-1) SERVING1.
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/3
/2
:2
:3
P
M G E
N G
S
V C \P ro j\
A D
P B
R
E P
L A
C E A
H U \F lo o rp la n s
D e s ig n \M
-7 .d g n
R E
P L
A C
E A
H U
91019
AD005235P
B P
R E
S S
E R
-A
P R -2
DDC
E
S
T
A
HWR
HWS
DDC
DDC
T DDC
DDC
E S
DDC
DDC
DDC T
SD
SD
CU
AHU
T
DDC
E S
DDC
RETURN AIR OUTSIDE AIR
MIXED AIR
SUPPLY FAN
COOLING COIL
HEATING COIL
CIRCUIT 1 CIRCUIT 2
SUPPLY AIR
A
SD
LEGEND:
S
DDC
T
E
T
SMOKE DETECTOR
THERMOSTAT
ACTUATOR
WITH LONWORKS DISPLAY)
(NEW CONTROLLER & NEW DDC PANEL
DIRECT DIGITAL CONTROL CONTROLLER
EQUIPMENT STATUS
EQUIPMENT ENABLE
TEMPERATURE SENSOR
M
M oi siviD gnire en i g
P
R E
S S
E R
KEY NOTES:
1 HWP-1 SHALL FEATURE A H-O-A SWITCH.
NOT TO SCALE
GENERAL NOTES:
M-702702 M
M
UNOCCUPIEDHOLIDAYS
UNOCCUPIEDSATURDAY & SUNDAY
0600 - 1800MONDAY - FRIDAY
DDC CONTROLLER SHALL BE PROGRAMMED WITH THE FOLLOWING OCCUPANCY SCHEDULE (ADJ).1.
SEQUENCE OF OPERATION FOR THE HW SYSTEM:
C O
N T
R O
L S
H O
T -W
A T
E R S
Y S
T E
M
OCCUPANCY SCHEDULE:
NOT TO SCALE
HOT-WATER SYSTEM CONTROL DIAGRAM HOT-WATER SYSTEM CONNECTIONS
M
M
THE ST SETPOINT SELECTED BY THE OCCUPANTS.
HEATING ST SETPOINTS. THESE VALUES SHALL BE DETERMINED INTERNALLY USING
DDC CONTROLLER SHALL MAINTAIN A 2°F DEADBAND BETWEEN THE COOLING AND5.
THE ST SETPOINT +/- 3°F USING THE BUILDING’S THERMOSTAT.
HEATING ST SETPOINT OF 72°F. OCCUPANTS SHALL HAVE THE ABILITY TO ADJUST
DDC CONTROLLER SHALL MODULATE A 3-WAY CONTROL VALVE TO SATISFY THE4.
WH-1 SHALL NEVER BE ENABLED WHEN HWP-1 IS DISABLED.3.
AFTER THIS OCCURS, HWP-1 SHALL BE DISABLED.
ABOVE THE HW SYSTEM ENABLE SETPOINT, WH-1 SHALL BE DISABLED. FIVE MINUTES
WHEN THE HVAC SYSTEM IS IN UNOCCUPIED MODE OR THE OA TEMPERATURE IS 3°F2.
SETPOINT OF 170°F (ADJ) USING ITS INTERNAL CONTROLS.
SHALL ALSO BE ENABLED. WH-1 SHALL MAINTAIN THE HW SUPPLY TEMPERATURE
ONCE THE CURRENT-SENSING RELAY FOR THE PUMP VERIFIES OPERATION, WH-1
BELOW THE HW SYSTEM ENABLE SETPOINT OF 65°F (ADJ), HWP-1 SHALL BE ENABLED.
WHEN THE HVAC SYSTEM IS IN OCCUPIED MODE AND THE OA TEMPERATURE IS1.
SYSTEM SHALL BE LONWORKS-COMPLIANT.
REPLACE TWO EXISTING MANUAL ISOLATION VALVES AS SHOWN. ALL COMPONENTS OF THE NEW DDC
OF OPERATION. SPECIFICALLY, CONTRACTOR SHALL INSTALL A NEW, MOTORIZED 3-WAY CONTROL VALVE AND
CONTRACTOR SHALL PROVIDE ALL CONTROL DEVICES NEEDED TO ACCOMPLISH THE SPECIFIED SEQUENCE3.
SEQUENCE OF OPERATION.
CONTRACTOR SHALL PROGRAM THE NEW LONWORKS DDC CONTROLLER TO ACCOMPLISH THE SPECIFIED2.
ACTUATORS, SHALL BE PRESERVED AND REUSED FOR THE NEW DDC SYSTEM, UNLESS NOTED OTHERWISE.
BUILDING 91019 AS SHOWN. EXISTING CONTROL DEVICES, INCLUDING SENSORS, RELAYS, VALVES, AND
CONTRACTOR SHALL ESTABLISH DDC CONTROLS FOR THE EXISTING HOT-WATER (HW) SYSTEM SERVING1.
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E
D a te
D e s c ri p ti o n ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/3
/2
:2
:3
P
M G E
N G
S
V C \P ro j\
A D
P B
R
E P
L A
C E A
H U \F lo o rp la n s
D e s ig n \M
-7 .d g n
R E
P L
A C
E A
H U
91019
AD005235P
B P
R E
S S
E R
-A
P R -2
E
S
DDC
WH
SE
DDC
T
DDC
T
DDC
HWP
HWR
HWS
TDDC
SENSOR
TEMPERATURE
OUTSIDE-AIR
DDC A
HWR
HWS
LEGEND:
S
T
E
DDC
A
UNION CONNECTION
BALL VALVE
3-WAY CONTROL VALVE
ACTUATOR
WITH LONWORKS DISPLAY)
(NEW CONTROLLER & NEW DDC PANEL
DIRECT DIGITAL CONTROL CONTROLLER
EQUIPMENT STATUS
EQUIPMENT ENABLE
TEMPERATURE SENSOR
n oi siviD gnire en i g
| G-101 Cover Sheet |
| M-001 |
| M-101 |
| M-102 |
| M-501 |
| M-601 |
| M-701 |
| M-702 |
File details come from the government source that posted it.