Revised_Drawing_0691C0000_10-29-18.pdf
PDF 46 KB Posted
- Attached to
- CLOSED CELL CROSS LINKED FOAM Federal contract opportunity
- Solicitation number
- W9098S19T0008
About this file
Revised Drawing
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 19T0008__Amend_Solicitation_10-29.pdf | ||
| drawing.pdf | ||
| 19T0008.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
A
D
D
C
B
A
CONTRACT NUMBER
CAGE CODESIZE
SCALE UNIT WT.
DESIGN ACTIVITY
CONTRACTOR
DRAWN BY DATE(YEAR-MO-DA)
CHECKER ENGINEER
ENGINEER QUALITY_ENGINEER
DRAWING APPROVAL
DESIGN APPROVAL
B
MODELED BYMATL ENGR
SHEET
TOLERANCE ON ANGLES
2 PLACE DECIMALS
3 PLACE DECIMALS
FORMAT: C_TACOM_ENG_1_0
DRAWING SIZE C
DWG NO.
DISTRIBUTION STATEMENT A.
APPROVED FOR PUBLIC RELEASE;
DISTRIBUTION IS UNLIMITED.
1 OF 10.0001.000
0691C000059678C
FOAM LAYER MATERIAL
US ARMY
ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER
ROCK ISLAND, ILLINOIS 61299-5000
YEAR-MM-DD(REQUIRED)
YEAR-MM-DD(REQUIRED)
J. LANGEL(REQUIRED)
YEAR-MM-DDJ. LANGEL
J. LANGEL
THIRD ANGLE PROJECTION
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
DO NOT SCALE DRAWING
APPLICATION
USED ONNEXT ASSY
MADCS0691C1000
MADCS0691C1001
PMIC
MECHANICAL
PROPERTIES
YP
TS
EL2
RA
BH
RH
REVISIONS
APPROVEDDATE(YEAR-MO-DA)DESCRIPTIONREVISION
YEAR-MM-DDALLOCATED BASELINE ERRX0
PART NO. 0691C0000
THIS DRAWING WAS GENERATED FROM A SOLID MODEL
AND IS CAD MAINTAINED. CHANGES SHALL BE
INCORPORATED BY THE DESIGN ACTIVITY.
NSN
SPECIFICATIONS
TYPE TOOL ORGANIZING LINER
MATERIAL CLOSED-CELL, CROSS-LINKED FOAM
DENSITY 4 TO 6 LBS PER CUBIC FT
WATER ABSORPTION NO MORE THAN .02 LBS/FT2 OVER CUT SURFACES
WHEN TESTED IAW ASTM D3575
CONTRASTING COLOR
THE FOAM SHALL BE ONE COLOR ON TOP AND A
CONTRASTING COLOR UNDERNEATH TO PROVIDE
CONTRASTING COLOR UNDERNEATH TOOLS TO AID
IN RAPID INVENTORY
CHEMICAL RESISTANCE
RESISTANT TO WATER, REFRIGERANTS,
AUTOMOTIVE OILS, GREASES, LUBRICANTS, FUELS
INCLUDING GASOLINE, DIESEL FUEL, JP-8 AND
JP-4, ACIDS, BASES, COOLANTS, ALCOHOLS, AND
CLEANING AGENTS
SEAMS
NO VERTICAL SEAMS ALLOWED; HORIZONTAL SEAMS
PERMITTED TO ALLOW FOR LAMINATION TO REACH
THE TOTAL THICKNESS NECESSARY AS WELL AS TO
RAISE THINNER ITEMS TO BE MORE ACCESSIBLE
ATTACHMENT
ALL SEAMS SHALL BE ATTACHED IN A PERMANENT
FASHION; SEAMS SHALL NOT SEPARATE WHEN
FORCE IS APPLIED; RATHER, THE TOOL
ORGANIZER ITSELF SHALL TEAR BEFORE THE SEAM
SEPARATES. THE ATTACHMENT SHALL REMAIN
PERMANENT WHEN STORED IN TEMPERATURES
RANGING FROM -25°F TO 170°F FOR NO LESS
THAN 4 HOURS.
NOTES
1. APPLICABLE STANDARDS/SPECIFICATIONS:
A. ASME Y14.100-2017
B. ASME Y14.5-2009
Sheet 1
File details come from the government source that posted it.