Salient_Characteristics_Form.xlsx
XLSX spreadsheet 13 KB Posted
- Attached to
- Provide liquid oxygen and nitrogen Federal contract opportunity
- Solicitation number
- W81K00-16-T-0338
- Issued by
- Department of the Army Medical Command
About this file
Bidders are required to address all the attached salient characteristics to be considered.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Modification.pdf | ||
| W81K00-16-T-0338.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1 Solicited: Bulk Medical Oxygen and Nitrogen Company: ___________________________
| Salient Characteristics | Proposed | |
| Must include: | ||
| 1 | Contractor shall be able to refill medical gas bulk listed in the CLINS twice weekly. BAMC has three |
bulk medical liquid oxygen tanks; two primary (9000 gallons) and a reserve (6000 gallons) plus a bulk liquid nitrogen tank (900 gallons). Refill quantity is based on the current meter readings.
2 The medical gas must be medical grade USP rated by the FDA. All medical gas manufactures and fillers of medical gas must be register with FDA as drug manufacturer.
3 All oxygen and nitrogen shall be manufactured, process, packed, transported and stored according to FDA Current Good Manufacturing Practice. (CGMP) regulations and all labeling shall comply with FDA’s labeling requirements.
4 Contractor shall be able to deliver medical grade gas within time frame specified by the facility POC. Contractor must provide emergency delivery within 24 hours after receipt of Government notification.
5 Contractor must be in compliance with DOT regulations regarding transporting medical gas to the facility. To include cylinder structure and color coded requirements according to AR 700‐68, Storage and Handling of Liquefied and Gaseous Compressed Gasses and their Full and Empty Cylinders.
6 Contractor must provide a valid certificate of analysis on medical grade gas when requested by the facility. Medical grade liquid nitrogen must be 99% pure at time of testing/certification prior to installation into the in‐line system.
7 Contractor must be licensed to transport and handle liquid oxygen and liquid nitrogen.
8 Contractor shall be able to have on site repairmen available to make repairs to the existing bulk system as required.
9 Contractor shall provide packing list at time of installation/delivery to ensure proper payment.
Sheet2
Sheet3
File details come from the government source that posted it. Updated .