PURCHASE DESCRIPTION (SALIENT CHARACTERISTICS)

US AFRICOM/EUCOM RF Tent and Secure Communications:

REQUIREMENTS/SALIENT FEATURES:

1) RF TENT (INFLATABLE RF SHIELDED ENCLOSURE): TFBS-060707-S-00-SYS (OR EQUIVALENT) TFBSD4 3x5x7 RF Shielded Enclosure System, or equivalent.

Dimensions: 3 width x 5 length x 7 height (feet)

Shall Pass/Exceed RF attenuation outlined in MIL STD 125I188 shall be inflatable, and light weight.

Equipped with 110/220 VAC air pumps No more than two person assembly No more than 15 minutes to assemble Shall be able to fit in rooms with 8 foot ceilings Lighting shall fully illuminate the interior of the enclosure shall Have an Environmental Control Unit (Air Conditioner) Auto sensing universal power supply (110I240 VAC 50~60Hz) Self evaporating condensate tray Airline checkable (62 linear inches max, 70lbs max) Shield Effectiveness Minimum 90Db Attenuation Dielectric Break (RJ45 {Ethernet} - Fiber - RJ45 {Ethernet}) Dielectric Break (RJ45 {ISDN} - Fiber - RJ45 {ISDN}) Entrance assembly utilizing conductive Velcro Transport Case - Hard: Enclosure and Frame Transport Case - Soft: Enclosure and Frame Transport Case - Hard: SECURX & Accessories Transport Case - Soft: SECURX & Accessories Instruction Manuals: Tent, Power, and Communications gear System Certification Report Tent/Enclosure Field Repair Kit Ruggedized Communications Connections -

- 4 Ethernet with dielectric breaks

- 2 Fiber Optic pass through signal (ST - ST)

- 1 ISDN signal connector with dielectric break

2) RF TENT EXTENDED WARRANTY (TFBSD060707DSD00DSYS):

Shall be compatible with the RF Tent Provides three (3) year coverage of the tent enclosure and ancillary equipment.

3) ENVIRONMENTAL CONTROL UNIT FOR RF TENT: SCSP-010101-SYS-01 SECAIR

Provide cooling for enclosure interior Rugged lightweight polymer construction Control Unit and Cables

4) ADDITIONAL SECURX MS UNIT WITH ISDN INTERFACE (OR EQUIVALENT):

Shall be compatible with RF Tent High Airflow/minimal noise air circulation blower Intake/Exhaust via high RF attenuating waveguide vent 10 amp (110-240 VAC/50~60 Hz) power supply via high performance power filter (100 dB from 20 MHz ~ 10 GHz.)

Ruggedized Communications Connections -

- 4 Ethernet with dielectric breaks

5) RF TENT (INFLATABLE RF SHIELDED ENCLOSURE): TFBS-060707-S-00-SYS (OR EQUIVALENT)

TFBS-4 6x7x7 RF Shielded Enclosure System, or equivalent.

Dimensions: 6 width x 7 length x 7 height (feet)

Shall Pass/Exceed RF attenuation outlined in MIL STD 125-188.

Be inflatable, and light weight Equipped with 110/220 VAC air pumps No more than two person assembly No more than 15 minutes to assemble Shall be able to fit in rooms with 8 foot ceilings Lighting shall fully illuminate the interior of the enclosure shall Have an Environmental Control Unit (Air Conditioner) Auto sensing universal power supply (110I240 VAC 50~60Hz) Self evaporating condensate tray Airline checkable (62 linear inches max, 70lbs max) Shield Effectiveness Minimum 90Db Attenuation Dielectric Break (RJ45 {Ethernet} - Fiber - RJ45 {Ethernet}) Dielectric Break (RJ45 {ISDN} - Fiber - RJ45 {ISDN}) Entrance assembly utilizing conductive Velcro Transport Case - Hard: Enclosure and Frame Transport Case - Soft: Enclosure and Frame Transport Case - Hard: SECURX & Accessories Transport Case - Soft: SECURX & Accessories Instruction Manuals: Tent, Power, and Communications gear System Certification Report Tent/Enclosure Field Repair Kit Ruggedized Communications Connections -

- 4 Ethernet with dielectric breaks

6) RF TENT EXTENDED WARRANTY (TFBSD060707DSD00DSYS):

Provides three (3) year coverage of the tent enclosure and ancillary equipment.

7) ENVIRONMENTAL CONTROL UNIT FOR RF TENT: SCSP-010101-SYS-01 SECAIR

Provide cooling for enclosure interior Rugged lightweight polymer construction Control Unit and Cables

8) MIB-RF TENT TRAINING:

Training to be held either on Kelley Barracks or Patch Barracks Training shall be compatible with RF Tent One day of demonstrations: set up, tear down, and maintenance Operational testing and overall unit instruction Leadership demonstration