AFRICOM_RF_Tent_Salient_Characteristics-For_Synopsis.pdf
PDF 89 KB Posted
- Attached to
- RF TENTS Federal contract opportunity
- Solicitation number
- W564KV-17-T-0018
About this file
Salient Characteristics
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W564KV-17-T-0018.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US AFRICOM/EUCOM RF Tent and Secure Communications:
Salient Features.
A) Requirements/Salient Features
1. RF Tent
2. Environmental Control Unit for RF Tent
3. RF Tent Extended Warranty
4. Additional SECURX ISDN interface (or equivalent)
5. MIB‐RF Tent Training
1) RF Tent (Inflatable RF Shielded Enclosure)
TFBS‐060707‐S‐00‐SYS,
TFBS‐4 6x7x7 RF Shielded Enclosure System, or equivalent.
Dimensions: 6 width x 7 length x 7 height (feet)
Must Pass/Exceed RF attenuation outlined in MIL STD 125‐188
Must be inflatable, and light weight.
Equipped with 110/220 VAC air pumps
No more than two person assembly
No more than 15 minutes to assemble
Must be able to fit in rooms with 8 foot ceilings
Lighting must fully illuminate the interior of the enclosure
Needs Environmental Control Unit (Air Conditioner)
Auto sensing universal power supply (110‐240 VAC 50~60Hz)
Self‐evaporating condensate tray
Airline checkable (62 linear inches max, 70lbs max)
Shield Effectiveness Minimum 90Db Attenuation
Dielectric Break (RJ45 {Ethernet} – Fiber – RJ45 {Ethernet})
Dielectric Break (RJ45 {ISDN} – Fiber – RJ45 {ISDN})
Entrance assembly utilizing conductive Velcro
Transport Case – Hard: Enclosure and Frame
Transport Case – Soft: Enclosure and Frame
Transport Case – Hard: SECURX & Accessories
Transport Case – Soft: SECURX & Accessories
Instruction Manuals: Tent, Power, and Communications gear
System Certification Report
Tent/Enclosure Field Repair Kit
Ruggedized Communications Connections –
‐ 4 Ethernet with dielectric breaks
‐ 2 Fiber Optic pass‐through signal (ST – ST)
‐ 1 ISDN signal connector with dielectric break
2) Environmental Control Unit for RF Tent
SCSP‐010101‐SYS‐01 SECAIR
Must be compatible with the RF Tent
Provide cooling for enclosure interior
Rugged lightweight polymer construction
Control Unit and Cables
3) RF Tent Extended Warranty
Must be compatible with the RF Tent
Provides five year coverage of the tent enclosure and ancillary equipment.
4) Additional SECURX MS Unit with ISDN interface (or equivalent)
Must be compatible with RF Tent
High Airflow/minimal noise air circulation blower
Intake/Exhaust via high RF attenuating waveguide vent
10 amp (110‐240 VAC/50~60hz) power supply via high‐performance power filter (100 dB from 20 Mhz ~ 10 Ghz.)
Ruggedized Communications Connections –
‐ 4 Ethernet with dielectric breaks
‐ 2 Fiber Optic pass‐through signal (ST – ST)
‐ 1 ISDN signal connector with dielectric break
5) MIB‐RF Tent Training
Training to be held either on Kelley Barracks or Patch Barracks
Training must be compatible with RF Tent
One day of demonstrations: set up, tear down, and maintenance
Operational testing and overall unit instruction
Leadership demonstration
B) Person receiving supply contact details.
HQ USAFRICOM
Unit 30401, Kelley Barracks, Plieningen Strass 289 Building 3312, Frank Foltyn 70567 Stuttgart
File details come from the government source that posted it. Updated .