CONTRACTING OFFICE/KWH
KENT W. HACKETT
918-420-6177/MCALESTER CONTRACTING
1 C TREE ROAD
MCALESTER OK 74501-9002
SEE SCHEDULE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to add CLIN 0002 to the solicitation.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 5
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 16-Aug-2016
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W44W9M-16-T-0337
X 9B. DATED (SEE ITEM 11)
28-Jul-2016
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
16-Aug-2016
CODE
CONTRACTING OFFICE
MCALESTER CONTRACTING OFFICE
1 C TREE ROAD
MCALESTER OK 74501-9002
W44W9M 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE W44W9M
FACILITY CODECODE
EMAIL:TEL:
W44W9M-16-T-0337
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SUPPLIES OR SERVICES AND PRICES
CLIN 0001
The CLIN extended description has changed from:
PRE-FABRICATED CONCRETE BUILDING, PER THE ATTACHED PURCHASE DESCRIPTION.
INSTALLED. MODULAR CONNECTIONS PRODUCT OR EQUAL.
To:
PRE-FABRICATED CONCRETE BUILDING, PER THE ATTACHED PURCHASE DESCRIPTION..
CLIN 0002 is added as follows:
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0002 1 Each
PREFABRICATED CONCRETE BUILDING
FFP
PRE-FABRICATED CONCRETE BUILDING, PER THE ATTACHED
PURCHASE DESCRIPTION.
FOB: Destination
NSN: 1AT STEAM PIT:4MJK0
MILSTRIP: W44W9M6228012Q
PURCHASE REQUEST NUMBER: W44W9M6228012Q
NET AMT
INSPECTION AND ACCEPTANCE
The following Acceptance/Inspection Schedule was added for CLIN 0002:
INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY
Destination Government Destination Government
The following have been modified:
PURCHASE DESCRIPTION
Pump Shelter Enclosure
The Concrete Shelter shall be standard construction featuring solid concrete design with 4 in. thick walls with steel rebar reinforced high strength concrete. The standard exterior finish is exposed aggregate, gray.
The Concrete Shelter shall be designed to be, Bulletproof to 30.06 Rifle from 15 feet per UL-752, provide 2-Hour Fire Rating per UBC, and be Virtually Waterproof and Maintenance Free (No Leakage unless surroundings are flooded).
The Shelter shall be equipped as follows:
1) 13 ft. 8 in. WOD x 26 ft. LOD x 11 ft. 1 in. HOD Concrete Shelter 12 ft. 7 in. WID x 24 ft. 11 in. LOD x 9 ft. 9 in. HID **** Manufactured in a NPCA Certified Facility**** Estimated Weight: 82,000 lbs. Unequipped Exterior Finish – Exposed Aggregate Greystone Gray Four (4) Cast-in Lift Shackles Internal (Non-Exposed) Structural Seals ¼ in. per Foot Roof Slope in All Four Directions with Rubber Membrane Secondary Roof Seal and 2 in. Roof Overhang on all Four Sides 300 PSF Floor Load Uniformly Distributed Consisting of 8 in. Thick Concrete Waffle Design with 4 in. Thick Solid Cap 60 PSF Roof Load Uniformly Distributed 150 MPH Wind Load Seismic Rated – Category D
2) Interior Finish ¾ in. Thick White HDPE Coated Plywood Paneling Walls and Ceiling Trowel Finished Urethane Painted Concrete Floor with Rubber Cove Molding
3) Insulation R-11 Walls R-19 Ceiling
4) Doors and Accessories One (1) 3 ft. x 7 ft. Exterior 18 Gauge Galvanized and Painted Steel Door with Cast-in 16 Gauge Galvanized and Painted Steel Door Frame with, NRP Non-Corrosive Hinges Lever Mortise Lockset with Deadbolt and Removable Core Aluminum Threshold and Door Sweep Weather-stripping Door Stop with Hold Open Latch Aluminum Drip Shield
Two (2) 10 ft. Wide x 8 ft. High Roll up Doors with, Slide Latch Locking Pull Chain, Manual Operated
5) Electrical System To be completed by the government.
6) Cooling / Heating One (1) 650 CFM (12 in.) Exhaust Fan with Gravity Flow Backdraft Louver and Screened Fiberglass Rain Hood, 12 in. Motorized Intake Louver with Screened and Filtered Fiberglass Rain Hood, and Thermostat Controls One (1) 2 kW Fan Forced Electric Wall Mounted Heater with Integral Thermostat Controls
7) Cable / Pipe Entrances Floor and Wall Penetrations as Required for doors and piping through floor and wall.
8) Delivery and Logistics Cost shall be included in quoted price.
9) Offload and Installation Completed by the government.
10) Engineering Three (3) PE sealed Engineering Analysis packages are included with each shelter.
11) Certifications Contractor shall comply with State Building Programs where applicable and required. Local/municipal inspections and approvals, including site inspections, building permits, and zoning approvals, are not included. Contractor is not responsible for determining such local/municipal requirements.
12) Warranty Shelter carries a one (1) year structural warranty from date of delivery.
Component accessories will carry the original equipment manufacturers’ warranty minimum of (1) year.
Steam Pit Enclosure
11 FT. 8 IN. WOD x 16 FT. LOD x 11 FT. 1 IN. HOD Concrete Shelter 10 FT. 7 IN. WID x 14 FT. 11 IN. LOD x 9 FT. 9 IN. HID Bulletproof to 30.06 Rifle from 15 feet per UL-752, provide 2-Hour Fire Rating per UBC, and be Virtually Waterproof and Maintenance Free Estimated Weight: 50,000 lbs. Unequipped.
Exterior Finish # Exposed Aggregate Greystone Gray.
Four (4) Cast-in Lift Shackles Internal (Non-Exposed) Structural Seals.
1/4 IN. per Foot Roof Slope in All Four Directions with Rubber Membrane Secondary Roof.
Seal and 2# Roof Overhang on all Four Sides.
150 PSF Floor Load 60 PSF Roof Load 150 MPH Wind Load
Seismic Rated # Category D Interior Finish: 3/4# White HDPE Coated Plywood Paneling Walls and Ceiling. Commercial Grade Vinyl Tile Concrete Floor with Rubber Cove Molding. Insulation: R-11 Walls. R-19 Ceiling Doors and Accessories One (1) 3# x 7# Exterior 18 Gauge Galvanized and Painted Steel Door with Cast-in 16 Gauge Galvanized and Painted Steel Door Frame with, NRP Non-Corrosive Hinges. Lever Mortise Lockset with Deadbolt and Removable Core. Aluminum Threshold and Door Sweep. Weather-stripping. Door Stop with Hold Open Latch. Aluminum Drip Shield.
One (1) 10# Wide x 8# High Roll up Door with, Slide Latch Locking Pull Chain Manual Operated
Electrical System:
A) 12 Circuit AC Load Center. 120/208 VAC Three Phase. 60 Hz Operation. 100 Amp Main Breaker B) Four (4) Dual Bulb Fluorescent Wet Location Interior Light Fixtures with Switch and Lenses C) One (1) 11 Watt LED Exterior Light Fixture with Switched Photocell D) Four (4) Duplex Convenience Receptacles # Wall Mounted E) Required Surface Mounted EMT Conduit, Connectors, Clamps, Breakers, and Wire Cooling / Heating: One (1) 650 CFM (12#) Exhaust Fan with Gravity Flow Backdraft Louver and Screened Fiberglass Rainhood, 12# Motorized Intake Louver with Screened and Filtered Fiberglass Rainhood, and Thermostat Controls. One (1) 2 kW Fan Forced Electric Wall mounted hearter with integral thermostat control