FSS-65-II-A - Ben's Precision Instruments, Inc. - V797D50575

DOC document 608 KB

Attached to
Federal Supply Schedule V797D50575 Federal contract IDV
Contract number
V797D50575
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12

About this file

Ben\'S Precision Instruments, Inc. (DBA B P I Medical) Pricelist and/or Vendor Terms and Conditions for V797D50575, a Federal Supply Schedule awarded to Ben\'S Precision Instruments, Inc. (DBA B P I Medical), under Medical Equipment and Supplies (FSS-65-II-A)

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The Department of Veterans Affairs Federal Supply Service

Authorized Federal Supply Schedule Price List

On-line access to contract ordering information, terms and conditions, up-to-date pricing, and the option to create an electronic delivery order are available through GSA Advantage!, a menu-driven database system. The INTERNET address for GSA Advantage is: GSAAdvantage.gov.

Medical Equipment and Supplies

FSC Group 65, Part II, Section A FSC Class:

Contract Number: V797D-50575 For more information on ordering Federal Supply Schedules click on the FSS Schedules button at fss.gsa.gov.

Contract Period: 03/15/2016 through 03/14/2021 Contractor Name

Ben’s Precision Instruments, Inc.

Address

4813 Pacific Hwy East, Fife, WA 98424

Phone #

(253) 883-5040

Fax #

(253) 883-5041 Contract Administration Source Jeff Loflin Business Size

Small Business Tax Identification Number (TIN) 91-1305753

CUSTOMER INFORMATION:

1a.

SIN A-200 (Equipment Maintenance and Repair)

1b.

SIN A-200

$0.63

2.

Maximum order: $500,000

3.

Minimum order: $25

4.

Geographic coverage: FOB Destination to the 50 States, District of Columbia, and Puerto Rico.

5.

Repair services conducted in Fife, WA USA

6.

Discount from list prices or statement of net price: .56% to 31.71% dependent on type of repair

7.

Quantity discounts: None

8.

Payment terms: 2% 20 Days; Net 30

9.

Government purchase cards are accepted up to, at, and above the Micro-Purchase Threshold (MPT).

10.

Foreign items: None

11a.

Time of delivery: Three (3) days after Receipt of Order (ARO)

11b.

Expedited Delivery. 24 hours. No additional charge from standard delivery rate.

11c.

Overnight delivery.

12.

F.o.b. destination to the 50 States, District of Columbia, and Puerto Rico

13a.

Ordering address: Ben’s Precision Instruments (dba BPI Medical), 4813 Pacific Hwy East, Fife, WA 98424 13b. Ordering procedures: For services, the ordering procedures, information on Blanket Purchase Agreements (BPA’s), and a sample BPA can be found at the GSA/FSS Schedule homepage (fss.gsa.gov/schedules)

14.

Payment address: Ben’s Precision Instruments (dba BPI Medical), 4813 Pacific Hwy East, Fife, WA 98424

15.

Warranty provision: See attached BPI Medical Warranty Policy

Return Goods Policy: n/a

16.

Export packing charges, if applicable: n/a

17.

Terms and conditions of Government purchase card acceptance (any thresholds above the micro-purchase level): Credit card acceptance below, equal to, and above MPT (Micro Purchase Threshold)

18.

Terms and conditions of rental, maintenance, and repair (if applicable): n/a

19.

Terms and conditions of installation (if applicable): n/a

20.

Terms and conditions of repair parts indicating date of parts price lists and any discounts from list prices (if applicable): n/a

20a.

Terms and conditions for any other services (if applicable): n/a

21.

List of service and distribution points (if applicable): n/a

22.

List of participating dealers (if applicable): n/a

23.

Preventive maintenance (if applicable): n/a

24a.

Special attributes such as environmental attributes (e.g., recycled content, energy efficiency, and/or reduced pollutants): n/a

24b.

If applicable, indicate that Section 508 compliance information is available on Electronic and Information Technology (EIT) supplies and services and show where full details can be found (e.g. contractor’s website or other location.) The EIT standards can be found at: : n/a

25.

Data Universal Number System (DUNS) number: 103344024

26.

System of Award Management (SAM): Registered

Warranty Policy BPI Medical, Inc. warrants all repairs done to instruments or equipment against defects in replacement components, materials and labor. All mechanical components and labor are covered by the warranty for a period of 90 days (3 months), from date of shipment from BPI Medical, Inc. All electrical components are covered by the warranty for a period of 90 days (3 months) from date of shipment. The warranty may be extended to 180 days (6 months) for rigid scopes, instruments, and certain Equipment Sales. Please refer to your quote or invoice for applicable warranty duration.

This warranty extends to all customers, but is limited only to the repair work previously done by BPI Medical. All instruments or equipment submitted due to defects in replacement components, materials, or labor during the warranty periods will be repaired at no charge to the customer (including shipping, which will be borne by the contractor).

This warranty does not apply to any instruments or equipment which has been subject to misuse, abuse, neglect, improper installation or operation, or that has been altered, adjusted, or tampered with by any person other than BPI Medical’s authorized repair technicians.

If upon examination by authorized repair technicians it is determined that the malfunction is due to misuse or abuse, warranty provisions will not apply. An estimate of the cost of repair work will be given to the customer prior to repairing the instrument or equipment along with the technician’s warranty evaluation.

Please contact our Customer Service at (253) 883-5041 for any inquiries regarding warranties and instructions for their return. Our hours of operation are 7:00 am to 4:00 pm Pacific Time.

Please send all warranty repairs to:

BPI Medical, Inc.

Attn: Warranty

4813 Pacific Hwy E Fife, WA 98424 Ben’s Precision Instruments Inc (dba BPI Medical Inc) Contract # V797D-50575

SIN
Product Number
Description
Unit Of Measure
FSS Net Price
A-200
401004
Surgical Instrument Repair - Arthroscopy Punch/Scissor/Grasper
EA
21.08
A-200
401005
Surgical Instrument Repair - Adenotome
EA
21.08
A-200
401006
Surgical Instrument Repair - Aspirating Needle
EA
21.08
A-200
401007
Surgical Instrument Repair - Awls
EA
8.62
A-200
401127
Surgical Instrument Repair - Bone Chisel
EA
7.40
A-200
401128
Surgical Instrument Repair - Curette, Bone/Adenoid/Cervical/Regular
EA
12.32
A-200
401129
Surgical Instrument Repair - Bone Cutter
EA
36.96
A-200
401131
Surgical Instrument Repair - Greenberg Arm Refurbish
EA
55.92
A-200
401132
Surgical Instrument Repair - Greenberg Arm, New Cable
EA
65.72
A-200
401133
Surgical Instrument Repair - Greenberg Arm, New Ball Joint
EA
17.65
A-200
401134
Surgical Instrument Repair - Greenberg Arm, New Handle
EA
51.65
A-200
401141
Surgical Instrument Repair - Greenberg Arm - Primary Bar
EA
33.19
A-200
401142
Surgical Instrument Repair - Greenberg Arm - Secondary Bar
EA
33.19
A-200
401143
Surgical Instrument Repair - Greenberg Arm - Floating Secondary Bar
EA
74.67
A-200
401137
Surgical Instrument Repair - Burr
EA
9.86
A-200
401138
Surgical Instrument Repair - Burr-Cranial
EA
9.86
A-200
401139
Surgical Instrument Repair - Burr-Large
EA
9.86
A-200
401140
Surgical Instrument Repair - Greenberg Arm, New Side Clamp
EA
89.36
A-200
401145
Surgical Instrument Repair - Calipers
EA
12.32
A-200
401147
Surgical Instrument Repair - Cannula
EA
18.48
A-200
401148
Surgical Instrument Repair - Cannula irrigating micro
EA
18.48
A-200
401150
Surgical Instrument Repair - Cement Removal Inst.
EA
18.48
A-200
401151
Surgical Instrument Repair - Chisel, inc. Bone & 4-sided
EA
9.98
A-200
401152
Surgical Instrument Repair - Chisel 4 sided
EA
9.98
A-200
401154
Surgical Instrument Repair - Clamp Bone Holding
EA
8.62
A-200
401160
Surgical Instrument Repair - Bookwalter Blades Refurbish
EA
6.16
A-200
401161
Surgical Instrument Repair - Bookwalter Horizontal Bar
EA
30.80
A-200
401167
Surgical Instrument Repair - Bookwalter, Horiz Bar, Floating
EA
99.57
A-200
401162
Surgical Instrument Repair - Bookwalter Ratchet
EA
40.62
A-200
401163
Surgical Instrument Repair - Bookwalter Blades - Replace
EA
57.67
A-200
401164
Surgical Instrument Repair - Bookwalter Post Coupeler
EA
36.96
A-200
401165
Surgical Instrument Repair - Bookwalter Ring
EA
24.64
A-200
401166
Surgical Instrument Repair - Bookwalter Table Post
EA
30.80
A-200
401170
Surgical Instrument Repair - Clamps, Vascular/Bulldog
EA
12.32
A-200
401176
Surgical Instrument Repair - Clamp Towel Clips
EA
7.76
A-200
401177
Surgical Instrument Repair - Clamp Vascular
EA
12.32
A-200
401178
Surgical Instrument Repair - Clip Applying Forceps
EA
18.48
A-200
401184
Surgical Instrument Repair - Curette Adenoid
EA
12.32
A-200
401185
Surgical Instrument Repair - Curette Micro
EA
30.80
A-200
401186
Surgical Instrument Repair - Curette, Dual Head/Micro
EA
30.80
A-200
401187
Surgical Instrument Repair - Curette Cervical
EA
12.32
A-200
401194
Surgical Instrument Repair - Deflector Bridge
EA
440.55
A-200
401196
Surgical Instrument Repair - Dilator, Sound
EA
8.62
A-200
401197
Surgical Instrument Repair -Dissector
EA
7.40
A-200
401199
Surgical Instrument Repair -Drill Bits-Burrs
EA
12.32
A-200
401201
Surgical Instrument Repair -Drill Twist
EA
12.32
A-200
401202
Surgical Instrument Repair -Dowel Cutter
EA
12.32
A-200
401210
Surgical Instrument Repair -Elevator, Periosteal/Rib/Freer/Bone
EA
6.16
A-200
401211
Surgical Instrument Repair -Elevator Dual
EA
18.48
A-200
401212
Surgical Instrument Repair -Elevator, Nasal/Dual/Micro
EA
18.48
A-200
401213
Surgical Instrument Repair -Elevator Nasal
EA
18.48
A-200
401214
Surgical Instrument Repair -Elevator Periosteal
EA
7.40
A-200
401215
Surgical Instrument Repair -Elevator Rib
EA
7.40
A-200
401216
Surgical Instrument Repair -Elevator Freer
EA
7.40
A-200
401217
Surgical Instrument Repair -Elevator Bone
EA
7.40
A-200
401219
Surgical Instrument Repair -Forcep, Reinsulate/Resolder Cord
EA
110.90
A-200
401221
Surgical Instrument Repair -Forcep, Debakey/Delivery
EA
7.40
A-200
401222
Surgical Instrument Repair -Forceps Delivery OB
EA
7.40
A-200
401223
Surgical Instrument Repair -Forcep Micro, Jeweler
EA
22.46
A-200
401224
Surgical Instrument Repair -Forcep, Tissue/Adson
EA
6.16
A-200
401225
Surgical Instrument Repair -Forcep New Carbide
EA
18.48
A-200
401226
Surgical Instrument Repair -Forcep Bipolar
EA
18.85
A-200
401227
Surgical Instrument Repair -Forcep Bipolar New Cap
EA
73.20
A-200
401228
Surgical Instrument Repair -Forcep Reinsulate
EA
110.90
A-200
401229
Surgical Instrument Repair -Forcep Bipolar, Re-insulate, New Cap
EA
110.90
A-200
401230
Surgical Instrument Repair -Forcep New Stopper
EA
36.96
A-200
401231
Surgical Instrument Repair -Forcep Flexible
EA
77.60
A-200
401232
Surgical Instrument Repair -Forcep Flexible-Straighten Shaft
EA
36.96
A-200
401233
Surgical Instrument Repair -Forcep Flexible-Major Overhaul
EA
110.90
A-200
401234
Surgical Instrument Repair -Forcep Flexible - New Needle
EA
49.17
A-200
401235
Surgical Instrument Repair -Forcep Flex-Hot, Rebuild
EA
135.56
A-200
401236
Surgical Instrument Repair -Forcep, Snare - Replace
EA
74.31
A-200
401239
Surgical Instrument Repair -Gouges
EA
12.32
A-200
401240
Surgical Instrument Repair -Hex Driver
EA
8.62
A-200
401241
Surgical Instrument Repair -Hex Driver, New Tip
EA
46.21
A-200
401245
Surgical Instrument Repair -Hooks General Surgery
EA
9.98
A-200
401246
Surgical Instrument Repair -Hooks Micro
EA
30.80
A-200
401247
Surgical Instrument Repair -Iglesias Working Element
EA
261.87
A-200
401248
Surgical Instrument Repair -Iglesias Thumb Ring
EA
65.44
A-200
401249
Surgical Instrument Repair -Iglesias New Tubing
EA
320.16
A-200
401250
Surgical Instrument Repair -Iglesias Remove Electrode
EA
55.46
A-200
401251
Surgical Instrument Repair -Iglesias Straighten Tube
EA
73.94
A-200
401252
Surgical Instrument Repair -Irrigation Handle
EA
129.21
A-200
401254
Surgical Instrument Repair -Kleppinger Forcep
EA
43.14
A-200
401256
Surgical Instrument Repair -Kleppinger Insert - Replace
EA
160.81
A-200
401257
Surgical Instrument Repair -Kleppinger New Thumb Ring
EA
76.52
A-200
401258
Surgical Instrument Repair -Kleppinger - Replace Suction Adapt
EA
43.01
A-200
401259
Surgical Instrument Repair -Knives, Amputation/Micro Eye/Regular
EA
24.64
A-200
401260
Surgical Instrument Repair -Knives Amputation
EA
24.64
A-200
401263
Surgical Instrument Repair -Knife, Micro Eye
EA
24.65
A-200
401264
Surgical Instrument Repair -Knife, sickle
EA
24.65
A-200
401275
Surgical Instrument Repair -Laryngeal Blade Refurbish
EA
12.32
A-200
401276
Surgical Instrument Repair -Laryngeal Blade, Replace Lamp
EA
26.62
A-200
401277
Surgical Instrument Repair -Laryngeal Blade, Replace Pin
EA
24.64
A-200
401278
Surgical Instrument Repair -Laryngeal Blade, Replace Ball
EA
24.64
A-200
401279
Surgical Instrument Repair -Ligature Carriers
EA
36.96
A-200
401280
Surgical Instrument Repair -Mallet Refurbish
EA
6.16
A-200
401281
Surgical Instrument Repair -Mallet, Replace Nylon Head
EA
67.35
A-200
401282
Surgical Instrument Repair -Mallet, Replace Handle
EA
97.85
A-200
401283
Surgical Instrument Repair -Mallet, Secure Handle
EA
24.40
A-200
401284
Surgical Instrument Repair -Mesh/skin Graft
EA
246.46
A-200
401285
Surgical Instrument Repair -Mesh/ Skin Graft, Major
EA
492.92
A-200
401286
Surgical Instrument Repair -Mesh/Skin Graft, Minor
EA
110.90
A-200
401288
Surgical Instrument Repair -Micro Instruments/Misc.
EA
24.64
A-200
401289
Surgical Instrument Repair -Micro Manipulators
EA
30.80
A-200
401290
Surgical Instrument Repair -Micro Loops-Probes
EA
30.80
A-200
401291
Surgical Instrument Repair -Mirror Dental, Refurbish
EA
6.65
A-200
401292
Surgical Instrument Repair -Mirror Dental-secure mirror
EA
20.94
A-200
401293
Surgical Instrument Repair -Mouth Gag Refurbish
EA
8.26
A-200
401294
Surgical Instrument Repair -Mouth Gag -replace silicone tube
EA
17.75
A-200
401301
Surgical Instrument Repair -Mouth Gag, color coat
EA
36.51
A-200
401295
Surgical Instrument Repair -Nail Clippers
EA
11.10
A-200
401296
Surgical Instrument Repair -Needle Holder, Refurbish Only
EA
11.54
A-200
401297
Surgical Instrument Repair -Needle Holder, New Carbide Jaws
EA
22.73
A-200
401298
Surgical Instrument Repair -Needle Holder, Shape New Seat
EA
27.18
A-200
401299
Surgical Instrument Repair -Needle Holder-Castro, Refurbish
EA
30.80
A-200
401300
Surgical Instrument Repair -Needle Holder, Diamond Dust
EA
54.34
A-200
401310
Surgical Instrument Repair -Osteotomes/Lambotte Refurbish
EA
8.62
A-200
401311
Surgical Instrument Repair -Osteotomes-2 sided - Carbides
EA
98.34
A-200
401315
Surgical Instrument Repair -Lambotte
EA
8.62
A-200
401316
Surgical Instrument Repair -Obturators
EA
8.62
A-200
401317
Surgical Instrument Repair -Pans/Genesis
EA
36.96
A-200
401318
Surgical Instrument Repair -Pans/Genesis-replace handle
EA
91.04
A-200
401319
Surgical Instrument Repair -Pan/Genesis-replace screw
EA
110.54
A-200
401320
Surgical Instrument Repair -Pans/Genesis-straighten blade lock
EA
30.80
A-200
401321
Surgical Instrument Repair -Pans/Genesis-replace blade lock
EA
55.15
A-200
401322
Surgical Instrument Repair -Pans/Genesis-reattach handle
EA
18.48
A-200
401323
Surgical Instrument Repair -Pans/Genesis-rivets (ea)
EA
24.64
A-200
401324
Surgical Instrument Repair -Pin/Wire Cutter Refurbish
EA
30.80
A-200
401325
Surgical Instrument Repair -Pin/Wire Cutter-new carbides
EA
255.09
A-200
401342
Surgical Instrument Repair -Pin/Wire Cutter, new jaws
EA
429.22
A-200
401326
Surgical Instrument Repair -Pin Cutter, large
EA
30.80
A-200
401327
Surgical Instrument Repair -Pitchers
EA
9.98
A-200
401328
Surgical Instrument Repair -Pitchers-secure handle
EA
12.63
A-200
401329
Surgical Instrument Repair -Pliers
EA
14.78
A-200
401330
Surgical Instrument Repair -Probes
EA
7.40
A-200
401331
Surgical Instrument Repair -Proctoscope
EA
36.96
A-200
40118
Surgical Instrument Repair -Punch
EA
27.27
A-200
401332
Surgical Instrument Repair -Rasps Refurbish
EA
8.62
A-200
401333
Surgical Instrument Repair -Rasps-replace carbides
EA
61.37
A-200
401334
Surgical Instrument Repair -Reamers, Twist/Hip(cheese grater)
EA
36.96
A-200
401335
Surgical Instrument Repair -Reamers-hip (cheese grater)
EA
36.96
A-200
401336
Surgical Instrument Repair -Reamers, Acetabular
EA
49.30
A-200
401337
Surgical Instrument Repair -Reamers, Flex/Rigid/Tapered
EA
30.80
A-200
401338
Surgical Instrument Repair -Reamers-Rigid
EA
30.80
A-200
401340
Surgical Instrument Repair -Reamers-twist
EA
36.96
A-200
401341
Surgical Instrument Repair -Reamers-tapered
EA
30.80
A-200
401343
Surgical Instrument Repair -Blades, Retractor, Refurbish
EA
24.64
A-200
401349
Surgical Instrument Repair -Retractor Chest Refurbish
EA
24.64
A-200
401350
Surgical Instrument Repair -Retractor chest -new blade
EA
111.47
A-200
401351
Surgical Instrument Repair -Retractor chest- new handle
EA
103.27
A-200
401353
Surgical Instrument Repair -Retractor Rib Spreader, Refurbish
EA
30.80
A-200
401354
Surgical Instrument Repair -Retractor-finochietto-new handle
EA
246.46
A-200
401355
Surgical Instrument Repair -Retractor, Locking-Gelpi/Weitliner
EA
12.75
A-200
401361
Surgical Instrument Repair -Retractor, Hand Held/Rake
EA
6.16
A-200
401368
Surgical Instrument Repair -Retractor rake
EA
6.16
A-200
401372
Surgical Instrument Repair -Retractor Weitlaner
EA
12.75
A-200
401153
Surgical Instrument Repair -Ring-handled Instrument
EA
9.18
A-200
401380
Surgical Instrument Repair -Rongeur, General
EA
27.18
A-200
401381
Surgical Instrument Repair -Rongeur, Disc/Pituitary/Double/Single
EA
30.80
A-200
401382
Surgical Instrument Repair -Rongeur Kerrison
EA
30.80
A-200
401385
Surgical Instrument Repair -Rongeur Kerrison remove horn
EA
18.48
A-200
401387
Surgical Instrument Repair -Rongeur Takahashi/Shutt
EA
24.64
A-200
401388
Surgical Instrument Repair -Rongeur Shutt
EA
24.64
A-200
401400
Surgical Instrument Repair -Scissors General/Iris/Wire/Mayo Metz
EA
5.44
A-200
401402
Surgical Instrument Repair -Scissors Delicate/Serrated
EA
10.98
A-200
401403
Surgical Instrument Repair -Scissors vascular and potts
EA
10.98
A-200
401404
Surgical Instrument Repair -Scissors, Supercut/Carbide
EA
7.32
A-200
401406
Surgical Instrument Repair -Scissors bandage
EA
5.44
A-200
401407
Surgical Instrument Repair -Scissor iris-tenotomy
EA
5.44
A-200
401408
Surgical Instrument Repair -Scissor super cut
EA
7.32
A-200
401410
Surgical Instrument Repair -Scissors wire
EA
5.44
A-200
401413
Surgical Instrument Repair -Scissor castro viejo
EA
21.08
A-200
401414
Surgical Instrument Repair -Scissors, Greishaber
EA
82.62
A-200
401416
Surgical Instrument Repair -Scissors, Micro Ear/Castro Viejo/Micro
EA
21.08
A-200
401417
Surgical Instrument Repair -Sheath/Cannula
EA
30.80
A-200
401418
Surgical Instrument Repair -Sheath-Valve replace
EA
63.65
A-200
401419
Surgical Instrument Repair -Sheath-replace lock lever
EA
46.70
A-200
401421
Surgical Instrument Repair -Sheath-Hysto
EA
24.64
A-200
401422
Surgical Instrument Repair -Sheath resectoscope
EA
55.46
A-200
401424
Surgical Instrument Repair -Snare, Ear/Nasal/Tonsil
EA
20.94
A-200
401425
Surgical Instrument Repair -Snare nasal
EA
20.95
A-200
401426
Surgical Instrument Repair -Snare tonsil
EA
20.95
A-200
401430
Surgical Instrument Repair -Speculum Eye Wire
EA
18.49
A-200
401431
Surgical Instrument Repair -Speculum Eye Ratchet
EA
24.65
A-200
401432
Surgical Instrument Repair -Speculum GYN/Eye Wire Refurbish
EA
18.48
A-200
401433
Surgical Instrument Repair -Speculum replace nut
EA
17.21
A-200
401434
Surgical Instrument Repair -Speculum Nasal/Eye Ratchet Refurbish
EA
24.64
A-200
401436
Surgical Instrument Repair -Speculum color coat
EA
98.71
A-200
401457
Surgical Instrument Repair -Color Coat Gyn Speculum
EA
149.35
A-200
401437
Surgical Instrument Repair -Speculum weighted
EA
12.32
A-200
401438
Surgical Instrument Repair -Stapling Equip
EA
73.94
A-200
401440
Surgical Instrument Repair -Stringers Refurbish
EA
6.16
A-200
401441
Surgical Instrument Repair -Stringers-new pin
EA
22.18
A-200
401442
Surgical Instrument Repair -Stringers-straighten pin
EA
6.16
A-200
401444
Surgical Instrument Repair -Suction, Poole/Frazier/w.Needle/Coagulation, Refurbish
EA
12.32
A-200
401445
Surgical Instrument Repair -Suction secure tube
EA
7.40
A-200
401446
Surgical Instrument Repair -Suction poole refurbish
EA
12.32
A-200
401447
Surgical Instrument Repair -Suction, Yankauer
EA
9.86
A-200
401448
Surgical Instrument Repair -Suction, new tip
EA
12.32
A-200
401449
Surgical Instrument Repair -Suction frazier refurbish
EA
12.32
A-200
401450
Surgical Instrument Repair -Suction w/needle refurbish
EA
12.32
A-200
401451
Surgical Instrument Repair -Suction-replace needle
EA
43.07
A-200
401452
Surgical Instrument Repair -Suction / Coagulation refurbish
EA
12.32
A-200
401453
Surgical Instrument Repair -Suction Tube, Micro
EA
30.80
A-200
401456
Surgical Instrument Repair -Suture Passer
EA
8.62
A-200
401460
Surgical Instrument Repair -Spring replacement-small
EA
19.64
A-200
401461
Surgical Instrument Repair -Spring replacement - large
EA
19.64
A-200
401462
Surgical Instrument Repair -Spring ratchet replacement
EA
18.42
A-200
401463
Surgical Instrument Repair -Stopcock Repl. (Per Stopcock)
EA
67.35
A-200
401464
Surgical Instrument Repair -Stopcock Handle or Pin
EA
30.74
A-200
401465
Surgical Instrument Repair -Tonometers
EA
12.32
A-200
401467
Surgical Instrument Repair -Tourniquets
EA
14.78
A-200
401313
Surgical Instrument Repair -Tray
EA
36.96
A-200
401468
Surgical Instrument Repair -Trephine
EA
12.32
A-200
401469
Surgical Instrument Repair -Trocar includes Pyramidal
EA
12.20
A-200
401470
Surgical Instrument Repair -Trocars, Pyramidal
EA
12.20
A-200
401480
Surgical Instrument Repair -Trumpet Valve repair
EA
36.96
A-200
401481
Surgical Instrument Repair -Trumpet valve replace
EA
79.67
A-200
401482
Surgical Instrument Repair -Urological working elmt (min)
EA
49.30
A-200
401483
Surgical Instrument Repair -Valvulatome
EA
12.32
A-200
401484
Surgical Instrument Repair -Verres needle Refurbish
EA
27.12
A-200
401485
Surgical Instrument Repair -Verres needle -new tube
EA
117.01
A-200
401495
Surgical Instrument Repair -Finish laser
EA
9.86
A-200
401496
Surgical Instrument Repair -Finish refurbish
EA
3.33
A-200
401497
Surgical Instrument Repair -Finish polish
EA
4.92
A-200
401498
Surgical Instrument Repair -Finish ebonize
EA
99.75
A-200
401499
Surgical Instrument Repair -Finish clear anodize
EA
92.42
A-200
401500
Surgical Instrument Repair -Finish titanium anodize
EA
54.34
A-200
401501
Surgical Instrument Repair -Finish diamond dust
EA
54.34
A-200
401502
Surgical Instrument Repair -Finish gold dip
EA
3.55
A-200
401510
Surgical Instrument Repair -Color coat-ring handle ea
EA
2.77
A-200
401513
Surgical Instrument Repair -Color coat-multi color ea.color
EA
3.88
A-200
401514
Surgical Instrument Repair -Insulation
EA
67.93
A-200
401520
Surgical Instrument Repair -Heat
EA
12.32
A-200
401521
Surgical Instrument Repair -Weld
EA
18.48
A-200
401523
Surgical Instrument Repair -Major Inst. Screw (rongeurs, lap instruments, large retractors, bone clamps, bone forcepts, pin & bolt cutters)
EA
12.93
A-200
401524
Surgical Instrument Repair -Spring
EA
19.64
A-200
401525
Surgical Instrument Repair -Pin
EA
18.48
A-200
401602
Surgical Instrument Repair -Lap repair ratchet mechanism
EA
30.80
A-200
401604
Surgical Instrument Repair -Lap replace insulation
EA
38.81
A-200
401605
Surgical Instrument Repair -Lap replace jaw-pin
EA
30.80
A-200
401606
Surgical Instrument Repair -Lap solder
EA
18.48
A-200
401610
Surgical Instrument Repair -Lap align and adjust
EA
12.32
A-200
401611
Surgical Instrument Repair -Lap sharpen only
EA
18.48
A-200
401612
Surgical Instrument Repair -Lap bovie adapter
EA
30.80
A-200
401613
Surgical Instrument Repair -Lap color coat handle
EA
59.89
A-200
401614
Surgical Instrument Repair -Lap color coat ratchet handle
EA
50.83
A-200
401653
Surgical Instrument Repair -Lap color coat shaft
EA
64.81
A-200
401615
Surgical Instrument Repair -Lap color coat rotator
EA
35.49
A-200
401617
Surgical Instrument Repair -Lap replace control rod
EA
61.31
A-200
401618
Surgical Instrument Repair -Lap replace control rod ball
EA
12.38
A-200
401620
Surgical Instrument Repair -Lap free frozen control rod
EA
36.96
A-200
401622
Surgical Instrument Repair -Lap l & j hook reinsulate
EA
42.14
A-200
401625
Surgical Instrument Repair -Taping per ring
EA
0.63
A-200
401626
Surgical Instrument Repair -Lap new hinges
EA
38.81
A-200
401629
Surgical Instrument Repair -Lap new screw
EA
19.10
A-200
401630
Surgical Instrument Repair -Lap new shaft
EA
338.89
A-200
401631
Surgical Instrument Repair -Lap ratchet mech. Repair
EA
24.64
A-200
401632
Surgical Instrument Repair -Lap machine rotator
EA
154.04
A-200
401633
Surgical Instrument Repair -Lap stopcock replacement
EA
60.99
A-200
401634
Surgical Instrument Repair -Lap stopcock handle
EA
30.74
A-200
401639
Surgical Instrument Repair -Lap new handle
EA
246.46
A-200
401644
Surgical Instrument Repair -Lap straighten
EA
12.32
A-200
401645
Surgical Instrument Repair -Lap remove dents
EA
18.49
A-200
401646
Surgical Instrument Repair -Lap new cap
EA
83.19
A-200
401647
Surgical Instrument Repair -Lap weld
EA
46.21
A-200
401648
Surgical Instrument Repair -Lap new rotator
EA
89.35
A-200
401649
Surgical Instrument Repair -Lap new luerlock
EA
24.52
A-200
401651
Surgical Instrument Repair -Lap free action lube
EA
18.49
A-200
401652
Surgical Instrument Repair -Lap needle holders, replace carbides
EA
166.36
A-200
401012
Surgical Sterilization Container Repair -Remove dent container lid / base - Minor
EA
33.19
A-200
401013
Surgical Sterilization Container Repair -Remove dent container lid / base - Major
EA
49.78
A-200
401014
Surgical Sterilization Container Repair -External clean (tape and sticker removal)
EA
24.89
A-200
401015
Surgical Sterilization Container Repair -Straighten / repair filter retention plate
EA
16.59
A-200
401016
Surgical Sterilization Container Repair -Remove container lid / base burr
EA
33.19
A-200
401017
Surgical Sterilization Container Repair -Inner basket repair mesh
EA
74.67
A-200
401025
Surgical Sterilization Container Repair -Latch repair
EA
34.02
A-200
401019
Surgical Sterilization Container Repair -Handle repair
EA
63.90
A-200
401020
Surgical Sterilization Container Repair -Gasket frame rivet repair
EA
16.59
A-200
401021
Surgical Sterilization Container Repair -Gasket frame rivet replace
EA
34.02
A-200
401022
Surgical Sterilization Container Repair -Gasket frame repaired
EA
65.29
A-200
401023
Surgical Sterilization Container Repair -Complete rebuild base - Full refurbishment, straighten, aligned, and adjusted. Includes the following as needed springs, washers, pin, rivets, nuts, and handles
EA
133.58
A-200
401024
Surgical Sterilization Container Repair -Complete rebuild lid - Full refurbishment, straighten, aligned, and adjusted. Includes the following as needed springs, washers, pin, rivets, nuts, handles and seal.
EA
56.00
A-200
444001
Pneumatic Surgical Hand Piece Repair without hose - LEVEL 1 Complete diagnostic. Five point exterior inspection and documentation. Minor repair stuck burr or blade/chuck repair. Minor repair trigger and switch. Complete specifications test.
EA
166.37
A-200
444002
Pneumatic Surgical Hand Piece Repair without hose - LEVEL 2 Complete diagnostic. Five point exterior inspection and documentation. Ten point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Complete specifications test.
EA
277.29
A-200
444003
Pneumatic Surgical Hand Piece Repair without hose - LEVEL 3 Complete diagnostic. Five Point exterior inspection and documentation. Ten Point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Replace bearings and vanes. Complete specifications test.
EA
476.92
A-200
444004
Pneumatic Surgical Hand Piece Dermatome Repair - LEVEL 1 Complete diagnostic. Five point exterior inspection and documentation. Minor repair stuck burr or blade/chuck repair. Minor repair trigger and switch. Complete specifications test.
EA
221.82
A-200
444005
Pneumatic Surgical Hand Piece Dermatome Repair - LEVEL 2 Complete diagnostic. Five point exterior inspection and documentation. Ten point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Complete specifications test.
EA
332.73
A-200
444006
Pneumatic Surgical Hand Piece Dermatome Repair - LEVEL 3 Complete diagnostic. Five Point exterior inspection and documentation. Ten Point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Replace bearings and vanes. Complete specifications test.
EA
554.56
A-200
444007
Pneumatic Surgical Hand Piece Dermatome Repair - Calibration & Parts
EA
381.60
A-200
444139
Pneumatic Surgical Hand Piece Dermatome Repair - Gauge Bar Replacement
EA
264.85
A-200
444130
Pneumatic Surgical Hand Piece Integrated Motor Repair with Hose - LEVEL 1 Complete diagnostic. Five point exterior inspection and documentation. Minor repair stuck burr or blade/chuck repair. Minor repair trigger and switch. Complete specifications test.
EA
187.44
A-200
444131
Pneumatic Surgical Hand Piece Integrated Motor Repair with Hose - LEVEL 2 Complete diagnostic. Five point exterior inspection and documentation. Ten point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Complete specifications test.
EA
471.38
A-200
444132
Pneumatic Surgical Hand Piece Integrated Motor Repair with Hose - LEVEL 3 Complete diagnostic. Five Point exterior inspection and documentation. Ten Point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Replace bearings and vanes. Complete specifications test.
EA
549.03
A-200
444133
Pneumatic Surgical Hand Piece Integrated Motor Repair with Inner Hose Replacement - LEVEL 1 Complete diagnostic. Five point exterior inspection and documentation. Minor repair stuck burr or blade/chuck repair. Minor repair trigger and switch. Complete specifications test. W/ inner hose replacement
EA
303.90
A-200
444134
Pneumatic Surgical Hand Piece Integrated Motor Repair with Inner Hose Replacement - LEVEL 2 Complete diagnostic. Five point exterior inspection and documentation. Ten point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Complete specifications test. W/ inner hose replacement
EA
587.84
A-200
444135
Pneumatic Surgical Hand Piece Integrated Motor Repair with Inner Hose Replacement - LEVEL 3 Complete diagnostic. Five Point exterior inspection and documentation. Ten Point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Replace bearings and vanes. Complete specifications test. W/ inner hose replacement
EA
665.48
A-200
444136
Pneumatic Surgical Hand Piece Integrated Motor Repair with Inner/Outer Hose Replacement - LEVEL 1 Complete diagnostic. Five point exterior inspection and documentation. Minor repair stuck burr or blade/chuck repair. Minor repair trigger and switch. Complete specifications test. W/ inner and outer hose replacement
EA
437.01
A-200
444137
Pneumatic Surgical Hand Piece Integrated Motor Repair with Inner/Outer Hose Replacement - LEVEL 2 Complete diagnostic. Five point exterior inspection and documentation. Ten point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Complete specifications test. W/ inner and outer hose replacement
EA
720.94
A-200
444138
Pneumatic Surgical Hand Piece Integrated Motor Repair with Inner/Outer Hose Replacement - LEVEL 3 Complete diagnostic. Five Point exterior inspection and documentation. Ten Point interior inspection and documentation. Clean and lubricate all internal parts. Replace all worn o-rings, clips and seals. Replace bearings and vanes. Complete specifications test. W/ inner and outer hose replacement
EA
798.58
A-200
444200
Pneumatic Surgical Hand Piece Attachment Repair - Burr Guard Replace up to two bearings, clean, lubricate and inspect. Test operation.
EA
56.01
A-200
445201
Pneumatic or Electric Surgical Hand Piece Attachment Repair - Simple Inspect, Clean, Lube & Replace Bearings and Seals as required.
EA
110.90
A-200
445204
Pneumatic or Electric Surgical Hand Piece Attachment Repair - Complex Inspect, Clean, Lube & Replace Bearings and Seals as required.
EA
332.56
A-200
445205
Pneumatic or Electric Surgical Hand Piece Attachment Repair - Chuck Inspect, Clean, Lube & Replace Bearings and Seals as required.
EA
174.24
A-200
445222
Pneumatic or Electric Surgical Hand Piece Attachment Repair - Chuck Replace Inspect, Clean, Lube & Replace Bearings and Seals as required. Replace Chuck
EA
348.49
A-200
444150
Pneumatic Surgical Hand Piece Hose Repair - LEVEL 1 Complete Diagnostic. Straighten Connectors. Replace O-ring. Complete Specifications Test.
EA
122.00
A-200
444151
Pneumatic Surgical Hand Piece Hose Repair - LEVEL 2 Complete Diagnostic. New inner/outer hose. New clips, spring, and O-ring. Straighten Connectors. Complete Specifications test.
EA
165.87
A-200
445-STR-4100-001
Electric Surgical Hand Piece Repair - Stryker 4100 / 4200 Series Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
277.29
A-200
445-STR-4100-002
Electric Surgical Hand Piece Repair - Stryker 4100 / 4200 Series Base Repair with PCBS and/Or Sensors Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs.
EA
443.66
A-200
445-STR-4100-003
Electric Surgical Hand Piece Repair - Stryker 4100 / 4200 Series Base Repair with Module Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor control module.
EA
776.40
A-200
445-STR-4100-004
Electric Surgical Hand Piece Repair - Stryker 4100 / 4200 Series Base Repair with Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor coil.
EA
471.09
A-200
445-STR-4100-005
Electric Surgical Hand Piece Repair - Stryker 4100 / 4200 Series Base Repair with PCB and Module Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor control module.
EA
942.77
A-200
445-STR-4100-006
Electric Surgical Hand Piece Repair - Stryker 4100 / 4200 Series Base Repair with PCB and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil.
EA
637.49
A-200
445-STR-4100-007
Electric Surgical Hand Piece Repair - Stryker 4100 / 4200 Series Base Repair with Module and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor control module. Replace motor coil.
EA
970.23
A-200
445-STR-4100-008
Electric Surgical Hand Piece Repair - Stryker 4100 / 4200 Series Base Repair with PCB, Module, and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor control module. Replace motor coil.
EA
1136.60
A-200
445-STR-2100-001
Electric Surgical Hand Piece Repair - Stryker 2100 Series Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
415.93
A-200
445-STR-2100-008
Electric Surgical Hand Piece Repair - Stryker 2100 Series Base Repair with PCB, Module, and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor control module. Replace motor coil.
EA
1081.41
A-200
445-STR-2296210-001
Electric Surgical Hand Piece Repair - Stryker Command II Models: 2296-(10,12,17,18,31,34,37,210,212,231,234,237), 296-(10,12,31,34,37) Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
332.73
A-200
445-STR-2296210-002
Electric Surgical Hand Piece Repair - Stryker Command II Models: 2296-(10,12,17,18,31,34,37,210,212,231,234,237), 296-(10,12,31,34,37) Base Repair with PCBS and/Or Sensors Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs.
EA
443.65
A-200
445-STR-2296210-004
Electric Surgical Hand Piece Repair - Stryker Command II Models: 2296-(10,12,17,18,31,34,37,210,212,231,234,237), 296-(10,12,31,34,37) Base Repair with Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor coil.
EA
720.93
A-200
445-STR-2296210-006
Electric Surgical Hand Piece Repair - Stryker Command II Models: 2296-(10,12,17,18,31,34,37,210,212,231,234,237), 296-(10,12,31,34,37) Base Repair with PCB and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil.
EA
831.84
A-200
445-STR-229688-001
Electric Surgical Hand Piece Repair - Stryker Command II Models: 2296-(80,88), 296-80 Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
332.73
A-200
445-STR-229688-002
Electric surgical Hand Piece Repair - Stryker Command II Models: 2296-(80,88), 296-81 Base Repair with PCBS and/Or Sensors Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs.
EA
720.93
A-200
445-STR-229688-004
Electric Surgical Hand Piece Repair - Stryker Command II Models: 2296-(80,88), 296-82 Base Repair with Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor coil.
EA
720.93
A-200
445-STR-229688-006
Electric Surgical Hand Piece Repair - Stryker Command II Models: 2296-(80,88), 296-83 Base Repair with PCB and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil.
EA
1109.14
A-200
445-STR-2296300-001
Electric Surgical Hand Piece Repair - Stryker TPS Models: 2296-100,Straight Drill 100K II & 2296-300; Impaction Drill Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
221.83
A-200
445-STR-2296300-006
Electric Surgical Hand Piece Repair - Stryker TPS Models: 2296-100,Straight Drill 100K II & 2296-300; Impaction Drill Base Repair with PCB and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil.
EA
998.22
A-200
445-STR-510010-001
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5100-10, 5100-15, 5100-25, 5100-31, 5100-34, 5100-37; Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
221.83
A-200
445-STR-510010-002
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5100-10, 5100-15, 5100-25, 5100-31, 5100-34, 5100-37; Base Repair with PCBS and/Or Sensors Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs.
EA
443.66
A-200
445-STR-510010-004
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5100-10, 5100-15, 5100-25, 5100-31, 5100-34, 5100-37; Base Repair with Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor coil.
EA
471.39
A-200
445-STR-510010-006
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5100-10, 5100-15, 5100-25, 5100-31, 5100-34, 5100-37; Base Repair with PCB and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil.
EA
693.22
A-200
445-STR-510088-001
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5100-88, 5100-99; Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
221.83
A-200
445-STR-510088-002
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5100-88, 5100-99; Base Repair with PCBS and/Or Sensors Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs.
EA
720.95
A-200
445-STR-510088-004
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5100-88, 5100-99; Base Repair with Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor coil.
EA
490.49
A-200
445-STR-510088-006
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5100-88, 5100-99; Base Repair with PCB and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil.
EA
989.62
A-200
445-STR-5400100-001
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5400- (100, 31, 34, 37 MD #s); Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
320.95
A-200
445-STR-5400100-002
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5400- (100, 31, 34, 37 MD #s); Base Repair with PCBS and/Or Sensors Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs.
EA
641.92
A-200
445-STR-5400100-004
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5400- (100, 31, 34, 37 MD #s); Base Repair with Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor coil.
EA
668.84
A-200
445-STR-5400100-006
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5400- (100, 31, 34, 37 MD #s); Base Repair with PCB and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil.
EA
989.80
A-200
445-STR-540088-001
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5400 Series 88/ 89 MD #s; Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
330.58
A-200
445-STR-540088-002
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5400 Series 88/ 89 MD #s; Base Repair with PCBS and/Or Sensors Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs.
EA
689.71
A-200
445-STR-540088-004
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5400 Series 88/ 89 MD #s; Base Repair with Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor coil.
EA
708.02
A-200
445-STR-540088-006
Electric Surgical Hand Piece Repair - Stryker TPS Models: 5400 Series 88/ 89 MD #s; Base Repair with PCB and Coil Replace Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil.
EA
1067.15
A-200
445031
Electric Surgical Hand Piece Dermatome Repair - LEVEL 1 Complete diagnostic. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals as needed.
EA
477.93
A-200
445032
Electric Surgical Hand Piece Dermatome Repair - LEVEL 2 Complete diagnostic. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace motor, bearings, 0-rings and shaft seals as needed.
EA
647.20
A-200
445134
Electric Surgical Hand Piece Dermatome Repair - Cable Replacement on Model B Cable replacement - Model B
EA
179.90
A-200
445136
Electric Surgical Hand Piece Dermatome Repair - Cable replacement on Models S & SB Cable Replacement - Model S & SB
EA
1533.36
A-200
445039
Electric Surgical Hand Piece Dermatome Repair - Calibration & Parts
EA
381.60
A-200
445139
Electric Surgical Hand Piece Dermatome Repair - Replace Gauge Bar
EA
264.85
A-200
445-STR/LIN-Shaver-021
Surgical Shaver Repair - Stryker Formula Series / Concept Linvatec; Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
515.77
A-200
445-STR/LIN-Shaver-022
Surgical Shaver Repair - Stryker Formula Series / Concept Linvatec; BASE WITH PCBS AND/OR SENSORS REPLACE Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs.
EA
903.96
A-200
445-STR/LIN-Shaver-023
Surgical Shaver Repair - Stryker Formula Series / Concept Linvatec; BASE REPAIR WITH CABLE REPAIR Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace cable
EA
1104.21
A-200
445-STR/LIN-Shaver-024
surgical Shaver Repair - Stryker Formula Series / Concept Linvatec; BASE REPAIR WITH COIL REPLACE Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace motor coil.
EA
792.56
A-200
445-STR/LIN-Shaver-025
Surgical Shaver Repair - Stryker Formula Series / Concept Linvatec; BASE WITH PCB AND CABLE REPLACE Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace cable.
EA
1492.57
A-200
445-STR/LIN-Shaver-026
Surgical Shaver Repair - Stryker Formula Series / Concept Linvatec; BASE WITH PCB AND COIL REPLACE Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil.
EA
1181.25
A-200
445-STR/LIN-Shaver-027
Surgical Shaver Repair - Stryker Formula Series / Concept Linvatec; BASE WITH COIL AND CABLE REPLACE Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace cable. Replace motor coil.
EA
1381.02
A-200
445-STR/LIN-Shaver-028
Surgical Shaver Repair - Stryker Formula Series / Concept Linvatec; BASE WITH PCB, COIL AND CABLE REPLACE Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals. Replace hall effect sensors and/or PCBs. Replace motor coil. Replace cable.
EA
1769.86
A-200
445-STR-Shaver-021
Surgical Shaver Repair - Stryker Base Complete diagnostic of motor coil current. Clean and lubricate all internal parts. Inspect unit for proper operation and adjust as required. Check RPM. Clean Contacts. Replace all bearings, 0-rings and shaft seals.
EA
277.29
A-200
445-STR-Shaver-022

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .