TEST BENCH SALIENT CHARACTERISTICS.pdf

PDF 118 KB Posted

Attached to
TEST BENCH Federal contract opportunity
Solicitation number
SPMYM221Q2291
Issued by
Defense Logistics Agency Land and Maritime

View the file

Other files for this federal contract opportunity

Other files attached to TEST BENCH, newest first.
File Type Posted
SPMYM2-21-Q-2291.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TEST BENCH SALIENT CHARACTERISTICS

PART NUMBER: MTTB10-W-O-G-M-L10-L100-L10-L100-DLA5-DLE30-75-7.5G-DG-DRD

City Water Test Circuit

• • L10-VE single air head air driven pump, 11:1 pressure ratio, 5.49 in³/cycle displacement, stainless steel construction, UHMWPE seals and Viton O-rings. Suitable for pressure tests from 165-

1,100 PSI

• • L100-VE single air head air driven pump, 113:1 pressure ratio, 0.54 in³/cycle displacement, stainless steel construction, UHMWPE seals and Viton O-rings. Suitable for pressure tests from

1,100-10,000 PSI

• • Inlet water bulkhead with 20 micron water filter and panel mount shutoff valve

• • Two manual pressure isolation valves in series, panel mounted.

• • Manual pressure vent valve, panel mounted

• • Pressure relief valve 100-1,000 psi adjustable, with isolation valve, panel mounted.

• • Pressure relief valve 1,000-10,000 psi adjustable, panel mounted.

• • Dual 4” outlet pressure gauges, 0-3,000 psi, panel mount, with isolation valve.

• • Dual 4” outlet pressure gauges, 0-10,000 psi, panel mount.

• • Inlet air drive filter

• • Panel mount drive air regulator with gauge

• • Individual air shut-off valve for each pump, panel mounted.

Hydraulic Oil Test Circuit

• • L10-VE single air head air driven pump, 11:1 pressure ratio, 5.49 in³/cycle displacement, stainless steel construction, UHMWPE seals and Viton O-rings. Suitable for pressure tests from 165-

1,100 PSI

• • L100-VE single air head air driven pump, 113:1 pressure ratio, 0.54 in³/cycle displacement, stainless steel construction, UHMWPE seals and Viton O-rings. Suitable for pressure tests from

1,100-10,000 PSI

• • Inlet oil bulkhead with 10 micron spin-on filter and panel mount shutoff valve

• • Two manual pressure isolation valves in series, panel mounted.

• • Manual pressure vent valve, panel mounted

• • Pressure relief valve 100-1,000 psi adjustable, with isolation valve, panel mounted.

• • Pressure relief valve 1,000-10,000 psi adjustable, panel mounted.

• • Dual 4” outlet pressure gauges, 0-3,000 psi, panel mount, with isolation valve.

• • Dual 4” outlet pressure gauges, 0-10,000 psi, panel mount.

• • Inlet air drive filter

• • Individual air shut-off valve for each pump, panel mounted.

Compressed Air Test Circuit

• • DLE5 single stage double acting single air head gas booster, 5:1 ratio, to boost incoming air to 600 psi

• • DLE30-75 two stage double acting single air head gas booster, 75:1 ratio, to boost 600 psi air to 8,700 psi maximum.

• • 1 Gallon 1,800 psi inter-stage bottle between boosters.

• • 1 Actual Cubic Foot (ACF) air receiver, 10,000 psi rated.

• • High pressure outlet pressure switch to switch the boosters of at 8,700 psi maximum. Pilot switch adjustable 4,350-8,700 psi.

• • Outlet gas regulator, 200-8,700 psi adjustable, panel mounted.

• • Inlet air bulkhead with 40 micron filter and panel mount shutoff valve

• • Two manual pressure isolation valves in series, panel mounted.

• • Manual pressure vent valve, panel mounted

• • Pressure relief valve 100-1,000 psi adjustable, with isolation valve, panel mounted.

• • Pressure relief valve 1,000-10,000 psi adjustable, panel mounted.

• • Dual 4” outlet pressure gauges, 0-3,000 psi, panel mount, with isolation valve.

• • Dual 4” outlet pressure gauges, 0-10,000 psi, panel mount.

• • Inlet air drive filter

• • Individual air shut-off valve for each booster, panel mounted.

File details come from the government source that posted it. Updated .