This document provides technical ordering data for an alternating current motor to be procured by the Defense Logistics Agency Land and Maritime under solicitation number SPMYM224Q0378. The motor specifications include a 150 nominal and 170 maximum horsepower, 440 volt 3 phase power at 60 hertz, totally enclosed fan cooled enclosure, 505Z frame, 3580 revolutions per minute at full load in a counterclockwise direction. Additional requirements cover insulation class, thermal protection sensors, bearing and grease specifications, terminal lead wires and lugs, paint finish, insulation resistance, and mounting orientation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SPMYM2-24-Q-0378.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATERIAL ORDERING DATA
IDN: N4523A-3304-5200
ICN: 38N4U-52119 KO: S02 KOI: 013
Paragraph Ordering Data
A. ALTERNATING CURRENT (AC) MOTOR, INTEGRAL-HORSE POWER, SHIPBOARD
USE, MIL-DTL-17060G WITH AMENDMENT 1, DATED 30 AUG 2016
B. Classification: Navy Service A--Heavy-duty, high impact, shock-resistant motors for driven auxiliaries.
C. Design/Duty: design B/Continues duty
D. Voltage/Frequency/Phases: 440 Volts/60Hz/3 Phases
E. Enclosure: Totally Enclosed Fan Cooled
F. Frame: 505Z
G. Synchronous Speed/Full Load RPM/Rotational: 3600/3580/in CounterClockwise (CCW).
H. HP: 150 NOM., 170 MAX
I. Amperes Full Load: 180 NOM, 200 MAX.
J. Type of Rotor: Squirrel Cage
K. Insulation Class: F minimum.
L. Winding Insulation: Epoxy with Sealed Insulation System
M. Thermal Protection: 3 each Thermal sensors per each phase group and shall be imbedded in the stator winding. Equipped with Temperature Monitoring System.
Thermistors per MIL-M-24738
N. Bearing/Grease: Low Noise per MIL-B-17931, Type III, Class 1/ bearing grease per DOD-G-24508
O. Terminal Lead Wires and Lugs: Per approved DWG A-505-83 Rev A.
P. Paint Finish: Machinery gray per MIL-E-917
Q. Winding Insulation Resistance: 500 megohms minimum
R. Gasket, Terminal Box: Per MIL-G-1149
MATERIAL ORDERING DATA
S. Mounting: Horizontal
T. Drive End Shaft Runout/Eccentricity/Flange face perpendicular/Total axial endplay: Per DWG A-505-83 Rev A