Tab 04 SOW.pdf

PDF 782 KB Posted

Attached to
Xiris XIR-1800 Basic SWIR Camera Kit and Calibration Federal contract opportunity
Solicitation number
80NSSC875509Q
Issued by
National Aeronautics and Space Administration

About this file

This document is a Statement of Work (SOW) for the purchase of the Xiris XIR-1800 Basic SWIR Camera Kit and Calibration by the Marshall Space Flight Center of NASA. The key requirements include the camera kit, calibration, and related lenses and filters. The SOW specifies the part numbers, descriptions, and technical details of the required products. The period of performance is approximately 3-4 weeks from receipt of the purchase order, with a requested delivery by September 1, 2024. The place of performance is the Marshall Space Flight Center in Huntsville, Alabama. This SOW is associated with a Special Notice federal contract opportunity (Solicitation Number 80NSSC875509Q) for the same products and services.

View the file

Other files for this federal contract opportunity

Other files attached to Xiris XIR-1800 Basic SWIR Camera Kit and Calibration, newest first.
File Type Posted
Tab 07 Capability Statement SAM.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

1. Objective/Requirements

Marshall Space Flight Center requires the purchase of the Xiris XIR-1800 Basic SWIR Camera Kit and Calibration for in situ, real-time monitoring of laser beam welding in support of suborbital laser beam welding TIP.

2. Characteristics, Scope, and Specs

Part # Description

880-02031

XIR-1800 Basic SWIR Camera Kit, No Lenses or Calibration – 120V, including:

XIR-1800 Thermal Camera (uncalibrated) Mounting Frame with integrated cooling channel, cover and protective windows Camera mounting arm Power Over Ethernet Injector Kit GigE Camera Cable – 10m Pelican Storage Case WeldStudio™ 3 Pro, Permanent Digital License

504-XIR-180

Standard Camera Calibration - performed at Xiris with a Precision, Traceable Black Body Temperature Source.

Calibrated at WD of 200 mm and FoV of 17 x 14 mm Accuracy is within +/- 10°C or 2% whichever is greater within the calibrated range of 350-1500°C.

Measurements above or below this range are extrapolated.

Calibration Certificate Provided

891-9520-5 50mm C-Mount SWIR Objective Lens

202-DNG-002 2X C-Mount Lens Magnifier

891-9551-1 Band Pass Filter (1550 nm)

209-UC000-1 UV-Protective Filter

203-F50C-03 50mm Objective Lens, C-Mount

202-DNG-002 2X Lens Magnifier, C-Mount

209-RC635-2 RED - Optical Filter

209-VC000-2 UV- Full IR Optical Filter

209-NC0D6-1 ND60 (25%) Neutral Density Filter wt. ring

209-UC000-1 Protection Filter with UV wt. ring

891-9357-4 Camera mounting arm

880-02083 Extended Mounting Plate with LED Illumination

3. Place of Performance

Marshall Space Flight Center Mail Stop EM31 4619 Saturn Rd Huntsville, AL 35812

4. Period of Performance

Approximately 3- 4 weeks from receipt of Purchase Order

*Delivery requested by September 1, 2024

File details come from the government source that posted it. Updated .