Text version
Statement of Work (SOW) for Fabrication of Fiber Optic MQJs
Fabrication of Fiber Optic Measurement Quality Jumpers (MQJs)
JML #: 02188634-02188635
Ship/Activity: OE Ship of Opportunity Title: MQJ Fiber Optic Test Equipment
BACKGROUND
REFERENCES
2.1 PPD 802-6337554 Rev (B) Section 9, Fiber Optic Assembly and Test Methods
WORK REQUIREMENTS
NOTE
Since PPD 802-6337554, Revision B, does not reflect the specific MQJs needed, the following criteria must be used to order the required MQJs.
3.2 2 modified PPD 802-633755-9.3.1-1 Single Mode Fiber MQJs with enhanced polish in-lieu of Multi-Mode fiber and master keying. The 1 Fiber Single Mode MQJs shall have a Receptacle on the “A-End” that will mate with a PPD 802-6337554-8.7.1-2 male insert.
3.3 2 modified PPD 802-6337554-9.3.1-3 Single Mode Fiber MQJ’s with enhanced polish in-lieu of Multi-Mode fiber and master keying. The 2 Fiber Single Mode MQJs shall have a Plug on the “A-End” that will mate with a PPD 802-6337554-8.8.1-8 or -9 female receptacle.
3.4 The “B-End” of each of the 3 Fiber MQJs shall consist of 3 one (1) meter lengths of
M85045/16-02. All termini on each MQJ shall be polished using the Single Mode Enhanced (SME) method.
3.5 Each MQJ shall be tested IAW section 9.2.4 of PPD 802-6337554, Revision B, for multi-terminus including return loss IAW 9.2.2.
3.5.1 An acceptance criterion for section 9.2.4.2 (insertion loss) is provided in PPD 802-
6337554, Revision B.
Statement of Work (SOW) for Fabrication of Fiber Optic MQJs
3.5.2 An acceptance criterion for section 9.2.4.3 is Optical Return Loss (ORL) greater than or equal to 40 dB.
3.6 Deliver the fabricated MQJs with Completed Test OQE per the Delivery Instructions provided below.
DELIVERABLE ITEMS
4.1 2 modified PPD 802-633755-9.3.1-1 Single Mode Fiber MQJ. The 1 Fiber Single Mode
MQJ with a Receptacle on the “A-End” that will mate with a PPD 802-6337554-8.7.1-2 male insert. The “B-End” of the Fiber MQJ having one (1) meter length of M85045/16- 02.
4.2 2 modified PPD 802-6337554-9.3.1-3 Single Mode Fiber MQJs. The 2 Fiber Single
Mode MQJs shall have a Plug on the “A-End” that will mate with a PPD 802-6337554- 8.8.1-8 or -9 female receptacle. The “B-End” of each of the 2 Fiber MQJs shall consist of 2 one (1) meter lengths of M85045/16-02.
QUALITY ASSURANCE SURVEILLANCE PLAN
Primary Performance Objectives
Performance Standard/AQL
Performance Assessment Method
Services provided such that repaired equipment functions as intended
100% compliance Contractor shall provide assessment report to COR
Contractor maintain close liaison and good communication with Government
Any problems or questions encountered by either party are addressed within 24 hours (1 business day)
Provide COR with written report of discrepancies
Final condition report of assessment
100% compliance Provide COR final assessment condition report
| 1. BACKGROUND |
| Puget Sound Naval Shipyard and Intermediate Maintenance Facility (PSNS/IMF) in support of SARAH Sparing on the SSN-21 and SSN-22 requires fiber optic test MQJs to verify ship infrastructure. PSNS&IMF requires the fabrication/manufacture of these MQJs ... |
| 2. REFERENCES |
| 3. WORK REQUIREMENTS |
| 3.1 Fabricate MQJs in accordance with the following: |
| 4. DELIVERABLE ITEMS |
| 5. QUALITY ASSURANCE SURVEILLANCE PLAN |