This document is a Special Packaging Instruction (SPI) related to a federal contract opportunity for a Hydraulic Transmission. The SPI provides detailed instructions for the preservation, packing, and marking requirements for a Hydraulic Transmission with a reusable container. It specifies the national stock number, part number, nomenclature, and technical details such as transmission weight, container weight, and dimensional information. The SPI outlines the required cleaning, drying, preservation, and packing methods, as well as the specific container, desiccant, and marking requirements. Quality assurance provisions and notes are also included. The related federal contract opportunity is for the procurement of 7 Hydraulic Transmissions with an option for 7 additional units. This is a Firm Fixed Price contract with a DLA provision for potential use of reverse auction as a pricing technique.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DD FORM 2169, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 2 Pages
SPECIAL PACKAGING INSTRUCTION Form Approved OMB No. 0704-0188
XCL
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
57K7252 (19207) TRANSMISSION WITH CONTAINER 19207 AK15778294
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
2520-01-577-8294 08/23/2024 A
7. QUP 8. ICQ 9. UNIT PACK WT. (LB) 10. UNIT PACK CU (CU FT) 11. UNIT PACK SIZE (INCHES)
001 NONE 1,593.0 LBS 53.700 60.0 X 43.0 X 40.8
12. MILITARY PRESERVATION (METHOD) 18.
STEPS
19.
REQ’D
20.
DESCRIPTION
MIL-STD-2073-1, METHOD 55 1-B A/R INTERNAL PRESERVATIVE: OPERATIONAL FLUID
13. CLEANING
MIL-STD-2073-1 2-C A/R EXTERNAL PRESERVATIVE: MIL-PRF-16173, GRADE 4
14. DRYING
MIL-STD-2073-1 3-D 48 DESICCANT: MIL-D-3464, TY I (48 UNITS REQUIRED)
15. PACKING 4-D 1 CONTAINER: P/N: 12573706, CAGE: 19207
A. LEVEL A
MIL-STD-2073-1 AND NOTE F
B. LEVEL B
NOT APPLICABLE
16. MARKING
MIL-STD-129 AND NOTE G
17. NOTES / DRAWING
CONSISTS OF: 1 EA. DRESSED TRANSMISSION, P/N 3815362, CAGE 75Q65 AND 1 EA. REUSABLE CONTAINER, P/N
12573706, CAGE 19207.
TRANSMISSION WEIGHT IS 850 LBS. AND REUSABLE CONTAINER WEIGHT IS 743 LBS.
A. QUALITY ASSURANCE PROVISIONS:
1. INSPECT THE PRESERVATION AND UNIT PACK IN ACCORDANCE WITH MIL-STD-2073-1.
2. INSPECT THE CONTAINER IN ACCORDANCE WITH A-A-52462, INCLUDING THE FIRST ARTICLE INSPECTION
REQUIREMENT.
B. FILL TRANSMISSION TO OPERATING LEVEL. ROTATE MECHANISM TO ENSURE 100% COVERAGE OF PRESERVATIVE ON INTERNAL SURFACES. REMOVE DRAIN PLUG AND DRAIN EXCESS PRESERVATIVE.
REPLACE DRAIN PLUG SECURELY.
(NOTE: IF TRANSMISSION HAS BEEN PREVIOUSLY RUN BY THE MANUFACTURER AND ALL INTERIOR
SURFACES HAVE BEEN COATED WITH THEIR APPROVED LUBRICANT, NO ADDITIONAL INTERNAL
PRESERVATION IS REQUIRED.)
C. APPLY TO UNPAINTED, UNPLATED FERROUS SURFACES.
D. MOUNTING HARDWARE FURNISHED WITH CONTAINER. FOR INSTALLATION INSTRUCTIONS AND DESICCANT APPLICATION, SEE INSTRUCTION DECAL LOCATED ON THE LOWER HALF OF THE ITEM CONTAINER.
E. THE PACKED REUSABLE CONTAINER WITH ITEM, SHALL BE PLACED IN A SHADED AREA AND MONITORED UNTIL THE INTERNAL RELATIVE HUMIDITY LEVEL STABILIZES AT OR BELOW 30 PERCENT. DESICCANT SHALL
BE REPLACED AS NEEDED UNIT A STABILIZED RELATIVE HUMIDITY LEVEL IS ACHIEVED.
(NOTE: THE STABILIZATION OF RELATIVE HUMIDITY LEVEL TYPICALLY REQUIRES A MINIMUM OF 24 HOURS
TO ACHIEVE.)
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 2 of 2 Pages
SPECIAL PACKAGING INSTRUCTION Form Approved OMB No. 0704-0188
XCL
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
57K7252 (19207) TRANSMISSION WITH CONTAINER 19207 AK15778294
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
2520-01-577-8294 08/23/2024 A
17. NOTES / DRAWING
F. THE UNIT CONTAINER IS THE SHIPPING CONTAINER.
G. THE FOLLOWING SPECIAL MARKING SHALL BE APPLIED:
TRANSMISSION ASSEMBLY SERIAL NUMBER SHALL BE STENCILED ON THE CONTAINER IN ACCORDANCE
WITH MIL-STD-129.