About this file

This Special Packaging Instruction document outlines packaging and preservation requirements for Housing, Mechanical part number 12321956. The Defense Logistics Agency Land and Maritime will solicit this item, with a quantity of 60 EA and a 100% option, under solicitation number SPRDL119R0283 expected to post on or around September 30, 2019. Packaging must be in accordance with MIL-STD-2073-1 and involve cleaning, preservation, cushioning, barrier materials, unit packaging, and marking per the document's detailed instructions. Inspection requirements include Group B examination of randomly selected samples and an S-1 inspection level with an AQL of 4.0%.

Special packaging instructions

View the file

Other files for this federal contract opportunity

Other files attached to Housing, Mechanical, newest first.
File Type Posted
SPRDL119R0283-0001.pdf PDF
SPRDL119R0283.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 2 Pages

SPECIAL PACKAGING INSTRUCTION

Form Approved OMB No. 0704-0188

The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS

1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.

12321956 (19207) 19207 AK12664019

4. NATIONAL STOCK NO. 5. DATE 6. REVISION

3040-01-266-4019 06/03/2019 A

7. QUP 8. ICQ 9. UNIT PACK WT (LB.) 10. UNIT PACK CU (CU. FT.) 11. UNIT PACK SIZE (INCHES)

1 Each None 53.0 5.740 34.5 x 19.5 x 14.8

12. MILITARY PRESERVATION 18.

STEPS

19.

REQD

20.

DESCRIPTION MIL-STD-2073-1, METHOD 41

13. CLEANING

1 A PRESERVATIVE: MIL-PRF-21260 GRADE 30

MIL-STD-2073-1 2 B CUSHION WRAP: A-A-59136

14. DRYING 3 C BARRIER: MIL-DTL-117 STYLE 1, TYPE I, CLASS E

MIL-STD-2073-1 4 FOAM IN PLACE, MIL-STD-119 TECHNIQUE I

15. PACKING (SEE NOTES D - G)

a. LEVEL A

MIL-STD-2073-1 AND NOTE I

b. LEVEL B

MIL-STD-2073-1 AND NOTE I

16. MARKING

MIL-STD- 129

17. NOTES/ DRAWING

A. APPLY OIL TO ALL EXTERNAL UNPAINTED UNPLATED SURFACES.

B. SECURE WITH TAPE.

C. CLOSE BAG BY HEAT SEALING.

D. PROCEDURES FOR FOAM IN PLACE PACKAGING, MATERIALS AND WORKMANSHIP SHALL BE AS SPECIFIED.

E. TO ACCOMPLISH THE FOAM IN PLACE PROCEDURE, THE FOLLOWING MATERIALS ARE REQUIRED.

1. BOX, FIBERBOARD ASTM-D5118, TYPE CF, 34 X 19 X 14 1EA

GRADE V3c, CLASS WR

2. TOP, PAD MIL-F-83671, CLASS 3 34 X 19 X 2 1EA

SEMI-RIGID

3. DRAPE A-A-3174, AS SPECIFIED AS REQUIRED 1EA

IN MIL-STD-1191

4. CUSHIONING MIL-P-83671, CLASS 3 SEE NOTE G

SEMI-RIGID

F. MINIMUM FOAM THICKNESS OR THE MINIMUM CLEARANCE BETWEEN THE CONTAINER WALLS AND THE

OUTERMOST PROJECTIONS OF THE WRAPPED AND BAGGED ITEM SHALL BE TWO INCHES.

G. 2.0 POUNDS OF FOAM IN ESTIMATED. THIS AMOUNT OF FOAM SHOULD ONLY BE USED AS A GUIDE.

THE AMOUNT OF FOAM ACTUALLY USED PER PACK WILL BE INFLUENCED BY EQUIPMENT TYPE, FOAM

FORMULATION, ATMOSPHERIC CONDITIONS, FACILITIES, ETC.

SPECIAL PACKAGING INSTRUCTION

Form Approved

OMB No. 0704-0188

The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS

1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CAGE 3. SPI NO.

12321956 (19207) 19207 AK12664019

4. NATIONAL STOCK NO. 5. DATE 6. REVISION

3040-01-266-4019 06/03/2019 A

DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 2 of 2 Pages

H. INSPECT THE PRESERVATION, THE UNIT PACK AND THE PACKING IN ACCORDANCE WITH MIL-STD- 2073-1 AND THE APPLICABLE CONTAINER SPECIFICATION. INSPECTION FOR THE FOAM-IN-PLACE

PACKAGING SHALL BE AS SPECIFIED IN MIL-STD-1191. SAMPLE SIZE FOR GROUP B AND C

INSPECTIONS OF MIL-STD-1191 SHALL CONSIST OF TWO PACKS SELECTED AT RANDOM FROM LOTS SUBMITTED FOR EXAMINATION. LOTS SUBJECT TO EXAMINATION SHALL BE LOT NO 1, 4, 7, 10 AND

RANDOMLY THEREAFTER FOR THE REMAINDER OF THE CONTRACT SUCH THAT THE TOTAL

FREQUENCEY OF SAMPLING OVER THE TOTAL CONTRACT QUANTITY DOES NOT EXCEED ONE

SAMPLING OUT OEVERY THREE LOTGS SUBMITTTED. PARAGRAPH 30.4.1.5 OF MIL-STD-1191 APPLIES

TO LOT INSPECTIONS. BOTH PACKS SELECTED WILL BE SUBJECTED TO GROUP B INSPECTION.

GROUP C ROUGH HANDLING AND SHOCK MITIGATION TEST ARE NOT REQURIED. THE INSPECTION

LEVEL SHALL BE S-1 AND AN AQL OF 4.0%.

I. LEVEL A PACKING SHALL BE ACCOMPLISHED USING WOOD-CLEATED PANELBOARD SHIPPING

BOXES, CONFORMING TO ASTM-D 6251, TYPE III, CLASS 2 OR NAILED WOOD BOXES CONFORMING TO

ASTM-D 6880, CLASS 2.

LEVEL B PACKING SHALL BE ACCOMPLISHED USING FIBERBOARD BOXES, WEATHER RESISTANT,

CONFORMING TO ASTM-D 5118 OR TRIPLEWALL, CORRUGATED FIBERBOARD BOXES, CLASS CGWR, CONFORMING TO ASTM-D 5168. CLOSURE, SEALING, AND REINFORCEMENT SHALL BE IAW SPECIFIC, APPLICABLE METHODS OF ASTM-D 1974, OR AS REFERENCED IN THE CONTAINER SPECIFICATION.

WHEN THE TOTAL QUANTITY TO BE SHIPPED TO THE SAME DESTINATION EXCEEDS 125 POUNDS, EXTERIOR PACKS WITHOUT SKIDS SHALL BE PALLETIZED IN ACCORDANCE WITH MIL-STD-147.

File details come from the government source that posted it. Updated .