DD FORM 2169, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 1 Pages
SPECIAL PACKAGING INSTRUCTION
Form Approved OMB No. 0704-0188
-XKG
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to the Department of Defense, Executive Services and Communications Directorate (0704-0188). Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR COMPLETED FORM TO THE ABOVE ORGANIZATION.
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
1587423-1 (83298) STATOR, ENGINE GENERATOR 19207 AK10461718
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
2920-01-046-1718 8-10-2011 B
7. QUP 8. ICQ 9. UNIT PACK WT. (LB) 10. UNIT PACK CU (CU FT) 11. UNIT PACK SIZE (INCHES)
1 EA. NONE 19.8 * 0.388 *
12. MILITARY PRESERVATION (METHOD) 18.
STEPS
19.
REQ’D
20.
DESCRIPTION
MIL-STD-2073-1D, METHOD 42 PRESERVATIVE: NONE
13. CLEANING
MIL-STD-2073-1D 1-B INTIMATE WRAP: MIL-DTL-17667, TYPE II
14. DRYING
MIL-STD-2073-1D 2-C CUSHIONING: ASTM D4727, TY CF, CL DOM, GR 275
15. PACKING 3-D 1 CONTAINER: ASTM D5118, TY CF, CL DOM, GR 275,
a. LEVEL A
ST RSC
MIL-STD-2073-1D AND NOTE F
b. LEVEL B
4-E 1 BAG: MIL-DTL-117, TY I, CL E, ST 1
MIL-STD-2073-1D AND NOTE F
16. MARKING
5-D 1 CONTAINER: ASTM D5118, TY CF, CL WR, GR W5c, MIL-STD-129 ST RSC
17. NOTES / DRAWING
A. INSPECT THE PRESERVATION AND UNIT PACK IN ACCORDANCE WITH MIL-STD-2073-1. INSPECT THE PACKING IN ACCORDANCE WITH MIL-STD-1186 AND THE APPLICABLE CONTAINER SPECIFICATION.
B. WRAP ITEM TWICE AND SECURE USING TAPE.
C. FIBERBOARD FILLER PADS AND/OR DIECUTS SHALL BE DEVISED AND USED TO IMMOBILIZE THE ITEM AND
PREVENT DAMAGE TO THE ITEM OR CONTAINER.
D. CLOSURE SHALL BE IN ACCORDANCE WITH ASTM D1974, METHOD 2B3.
E. COMPUTE SIZE AND CONFORM BAG IN ACCORDANCE WITH MIL-STD-2073-1D. CLOSE BAG BY HEAT SEALING.
F. PACKING:
LEVEL A PACKING SHALL BE ACCOMPLISHED USING WOOD-CLEATED PANELBOARD SHIPPING BOXES, CONFORMING TO ASTM-D 6251, TYPE III, CLASS 2 OR NAILED WOOD BOXES CONFORMING TO ASTM-D 6880, CLASS 2.
LEVEL B PACKING SHALL BE ACCOMPLISHED USING FIBERBOARD BOXES, WEATHER RESISTANT,
CONFORMING TO ASTM-D 5118 OR TRIPLEWALL, CORRUGATED FIBERBOARD BOXES, CLASS 2,
CONFORMING TO ASTM-D 5168. CLOSURE, SEALING, AND REINFORCEMENT SHALL BE IAW SPECIFIC, APPLICABLE METHODS OF ASTM-D 1974, OR AS REFERENCED IN THE CONTAINER SPECIFICATION.
WHEN THE TOTAL QUANTITY TO BE SHIPPED TO THE SAME DESTINATION EXCEEDS 125 POUNDS, EXTERIOR
PACKS WITHOUT SKIDS SHALL BE PALLETIZED IN ACCORDANCE WITH MIL-STD-147.
* UNIT PACK WT. AND CU. ARE ESTIMATED AND ARE PROVIDED FOR INTERNAL GOVERNMENT PURPOSES ONLY.