Text version
DD FORM 2169, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 4 Pages
SPECIAL PACKAGING INSTRUCTION Form Approved OMB No. 0704-0188
-CC
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12274501 (19207) HOUSING, STEERING CO 19207 AK10635678
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
2530-01-063-5678 2-5-2007 C
7. QUP 8. ICQ 9. UNIT PACK WT. (LB) 10. UNIT PACK CU (CU FT) 11. UNIT PACK SIZE (INCHES)
1 EA NONE 225.0 7.136 28.1 X 21.2 X 20.7
12. MILITARY PRESERVATION (METHOD) 18.
STEPS
19.
REQ’D
20.
DESCRIPTION
MIL-STD-2073-1D, METHOD 43
13. CLEANING
MIL-STD-2073-1D
14. DRYING
MIL-STD-2073-1D
SEE NOTES.
15. PACKING
a. LEVEL A
MIL-STD-2073-1D AND NOTE E
b. LEVEL B
MIL-STD-2073-1D AND NOTE E
16. MARKING
MIL-STD-129
17. NOTES / DRAWING
A. REFER TO THE BILL OF MATERIALS FOR ALL REFERENCED ITEMS AND CIRCLED PART NUMBERS ON THE
ACCOMPANYING PAGES.
B. APPLY PRESERVATIVE, ITEM 1, TO ALL BARE FERROUS SURFACES.
C. WRAP PART WITH WRAP, ITEM 2, AND SECURE WITH TAPE. MAKE SURE TO APPLY WRAP WITH
GREASEPROOF SIDE TOWARD THE PART.
D. PREPARE CONTAINER, ITEM 12, AS SHOWN ON PAGE 3. TO LOCATE HOLES IN BARRIER, ITEM 9, INSERT CARRIAGE BOLTS, ITEM 5, THROUGH BOTTOM OF ASSEMBLED CRATE PLATFORM (SEE PAGE 3). WITH THE BARRIER CENTERED ON THE PLATFORM, PRESS DOWN ON THE INSIDE BOTTOM OF THE BARRIER UNTIL TOUCHING THE PLATFORM BASE. APPLY ENOUGH PRESSURE ON BOLT ENDS SO THE BARRIER BECOMES INDENTED, MARKING WHERE THE HOLES SHOULD BE MADE. GASKETS, ITEM 10, SHALL BE CEMENTED TO BOTH SIDES OF THE BARRIER AT THE MOUNTING LOCATIONS USING ADHESIVE, ITEM 11. AFTER POSITIONING BARRIER OVER BOLTS, A SUFFICIENT QUANTITY OF ADHESIVE SHALL BE APPLIED AROUND
THE BOLTS AND GASKETS TO PROVIDE AN AIRTIGHT SEAL.
E. THE UNIT CONTAINER IS AN ACCEPTABLE LEVEL A AND LEVEL B SHIPPING CONTAINER.
F. INSPECT THE PRESERVATION, THE UNIT PACK, AND THE PACKING IN ACCORDANCE WITH MIL-STD-2073-1D
AND THE APPLICABLE CONTAINER SPECIFICATION.
OMB No. 0704-0188
-CC
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12274501 (19207) HOUSING, STEERING CO 19207 AK10635678
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
2530-01-063-5678 2-5-2007 C
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 2 of 4 Pages
OMB No. 0704-0188
-CC
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12274501 (19207) HOUSING, STEERING CO 19207 AK10635678
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
2530-01-063-5678 2-5-2007 C
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 3 of 4 Pages
BASE OF
CONTAINER
4 PLACES
6 7 8
P/N 12274501
2 PLACES
2 PLACES
2 PLACES
4 PLACES
DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 4 of 4 Pages
OMB No. 0704-0188
-CC
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12274501 (19207) HOUSING, STEERING CO 19207 AK10635678
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
2530-01-063-5678 2-5-2007 C
BILL OF MATERIALS
ITEM
NUMBER DESCRIPTION SIZE SPECIFICATION DATA QTY.
1 PRESERVATIVE MIL-PRF-32033. A/R
2 WRAP 36 X 75 MIL-PRF-121, TYPE II, STRETCHABLE. 1
3 BLOCKING 2 X 4 (NOM) X 19,
SEE PAGE 2
ASTM-D6199, CLASS 2,
GROUP II OR III.
4 PAD 3-1/2 X 19,
SEE PAGE 2
ASTM-D4727, TYPE CF, CLASS WR,
VARIETY SW, GRADE V3c.
5* BOLT, CARRIAGE ½ X 9 COMMERCIAL GRADE. 4
6* WASHER, FLAT ½ COMMERCIAL GRADE. 4
7* WASHER, LOCK ½ COMMERCIAL GRADE. 4
8* NUT, HEX ½ COMMERCIAL GRADE. 4
9 BARRIER 35 X 36 MIL-DTL-6060. 1
10 GASKET 4 X 4 X 1/16 ASTM-F104, TYPE 2. 8
11 ADHESIVE MMM-A-260. A/R
12 CONTAINER 25-1/4 X 19-3/4 X
15-1/2, SEE PAGE 2
ASTM-D6880, CLASS 2, STYLE 2. 1
* COMMERCIAL QUALITY STEEL IS ACCEPTABLE WITH ZINC PLATING OR PRESERVATIVE COATING
CONFORMING TO MIL-PRF-16173, GRADE 4.
File details come from the government source that posted it.