SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 30 - BLOCK 14 CONTINUATION PAGE

The following have been added by full text:

QUESTIONS

The answers to your questions are provided below:

1) Do these cables have to meet the OPNAVINST 11310.3B?

Answer: No.

2) Do the conductor legs have to have a heat shrink over them?

Answer: Yes, for Enhanced THOF-500 cable. No, for Enhanced THOF-500 Plus cable.

3) Do the contact insulator/sleeves have to be vulcanized?

Answer: No, the insulator/sleeve should be molded directly onto cable leads after the contact is installed. Separate or pre-molded insulator/sleeves that are vulcanized onto the cable leads are Not Acceptable.

(End of Summary of Changes)