SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
QUESTIONS
The answers to your questions are provided below:
1) Do these cables have to meet the OPNAVINST 11310.3B?
Answer: No.
2) Do the conductor legs have to have a heat shrink over them?
Answer: Yes, for Enhanced THOF-500 cable. No, for Enhanced THOF-500 Plus cable.
3) Do the contact insulator/sleeves have to be vulcanized?
Answer: No, the insulator/sleeve should be molded directly onto cable leads after the contact is installed. Separate or pre-molded insulator/sleeves that are vulcanized onto the cable leads are Not Acceptable.
(End of Summary of Changes)
File details come from the government source that posted it. Updated .