AMENDED SOLICITATION SPMYM2225Q1776.pdf

PDF 363 KB Posted

Attached to
TOE JACK Federal contract opportunity
Solicitation number
SPMYM225Q1776
Issued by
Defense Logistics Agency Land and Maritime

About this file

This document is an Amendment of Solicitation/Modification of Contract for a HUBZone set-aside solicitation for Jung Compact Toe Jacks. The amendment modifies two key aspects: the response deadline has been extended from 28-May-2025 11:00 AM to 12-Jun-2025 08:00 AM, and the technical specifications for CLIN 0002 have been slightly revised, including changes to cylinder volume, jack height measurements, and the number of starting positions for the lifting toe. The solicitation is for a Jung Compact Toe Jack, Model 10GPLUS, with a 10-ton (20,000 lb) capacity, issued by the Defense Logistics Agency Maritime Puget Sound, with electronic submission required through SAM.gov.

The solicitation requires vendors to submit complete documentation, including manufacturer specifications in PDF format, cage code, lead time, manufacturer name, and country of manufacturing. Vendors quoting alternative products must provide detailed specifications, or their bids will be considered non-responsive. The solicitation includes specific technical requirements for the toe jack, such as low-profile lifting toes, swivel capabilities, compact dimensions, and compliance with ASME B30.1 standards. Contractors may be required to implement NIST SP 800-171 security requirements, with an exception for Commercial Off-The-Shelf (COTS) items.

View the file

Other files for this federal contract opportunity

Other files attached to TOE JACK, newest first.
File Type Posted
SOLICITATION SPMYM225Q1776.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N4523A50960160

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

REVISE SALIENT CHARACTERSITICS FOR CLIN 0002

EXTEND OFFER DUE DATE

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 11-Jun-2025

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X SPMYM225Q1776

X 9B. DATED (SEE ITEM 11)

22-May-2025

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

11-Jun-2025

CODE

DLA MARITIME PUGET SOUND

ATTN: JACK EDWARDS

467 W STREET

BREMERTON WA 98312

SPMYM2 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

SPMYM225Q1776

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

SOLICITATION/CONTRACT FORM

The required response date/time has changed from 28-May-2025 11:00 AM to 12-Jun-2025 08:00 AM.

SUPPLIES OR SERVICES AND PRICES

CLIN 0002

The CLIN extended description has changed from:

JUNG COMPACT TOE JACK, MODEL 10GPLUS, CAPACITY 10 TONS/20,000 LBS VENDOR P/N: MPN

JH10GPLUS MANUFACTURER P/N: JH 10 G PLUS MFG: JUNG**SEE BELOW SALIENT

CHARACTERISTICS**Salient characteristics for 5 ton capacity Compact Toe Jacks, JML DOC: 50960161-Toe jacks must have a 10 ton (20,000 lb. working load limit)-Each Toe jack must come with one hydraulic jack and one pumping handle-Pumping handle for toe jacks must be able to be locked upright to tip back the jack onto it’s wheels for rolling for easy placement-Toe jacks must have low profile lifting toes. Toes must swivel for tilted loads and a firm grip-Jack feet must swivel to prevent tipping/slipping-Toe jack model must be considered compact in size, dimensions: 13.6” L x 9.7” W +/- 1” and must not exceed a weight of 65 lbs. per toe jack.-Toe jacks must meet ASME B30.1-toe jacks must have an incremental toe height adjustment of 1.6”-Toe jacks must have a jack height of 18.1” +/- 1” in extended position-Toe jacks must have a maximum toe height starting position of 7.2” +/- 2”-Toe jacks must have a 5.9” stroke-Toe jacks must have 2.2” usable toe depth-Toe jacks must have a cylinder volume of 11.5” (cubic inches)-Toe jack height when retracted: 9.6”-Toe jack height when extended: 19.6”-must be considered indoor/outdoor jacks-must have 7540 PSI working pressure-lifting toe must be adjustable and have 6 starting positionsBRAND NAME OR EQUAL TO:MFR: JUNGPN: MPN JH10GPLUS MFR

NAME:______________________________________

BRAND:__________________________________________

P/N:_____________________________________________ NOTE: VENDORS QUOTING EQUALS MUST

SUBMIT THEIR BID WITH MANUFACTURER SPECIFICATIONS (PDF FORMATTED) FOR

EVALUATION. BIDS RECEIVED FOR EQUALS WITHOUT MANUFACTURER SPECIFICATIONS WILL BE

NON-RESPONSIVE AND NOT CONSIDERED.

To:

JUNG COMPACT TOE JACK, MODEL 10GPLUS, CAPACITY 10 TONS/20,000 LBS VENDOR P/N: MPN

JH10GPLUS MANUFACTURER P/N: JH 10 G PLUS MFG: JUNG**SEE BELOW SALIENT

CHARACTERISTICS**Salient characteristics for 5 ton capacity Compact Toe Jacks, JML DOC: 50960161-Toe jacks must have a 10 ton (20,000 lb. working load limit)-Each Toe jack must come with one hydraulic jack and one pumping handle-Pumping handle for toe jacks must be able to be locked upright to tip back the jack onto it’s wheels for rolling for easy placement-Toe jacks must have low profile lifting toes. Toes must swivel for tilted loads and a firm grip-Jack feet must swivel to prevent tipping/slipping-Toe jack base must be considered compact in size, dimensions: 13.6” L x 9.7” W +/- 1” and must not exceed a weight of 65 lbs. per toe jack.-Toe jacks must meet ASME B30.1-toe jacks must have an incremental toe height adjustment of 1.6”-Toe jacks must have a jack height of 18.1” +/- 1” in extended position-Toe jacks must have a maximum toe height starting position of 7.2” +/- 2”-Toe jacks must have a 5.9” stroke-Toe jacks must have 2.2” usable toe depth-Toe jacks must have a cylinder volume of 19.6”-Toe jack height when retracted: 12.2”-Toe jack height when extended: 13”-must be considered indoor/outdoor jacks-must have 7540 PSI working pressure-lifting toe must be adjustable and have 5 starting positionsBRAND

NAME OR EQUAL TO:MFR: JUNGPN: MPN JH10GPLUS MFR

SPMYM225Q1776

NAME:______________________________________

BRAND:__________________________________________

P/N:_____________________________________________ NOTE: VENDORS QUOTING EQUALS MUST

SUBMIT THEIR BID WITH MANUFACTURER SPECIFICATIONS (PDF FORMATTED) FOR

EVALUATION. BIDS RECEIVED FOR EQUALS WITHOUT MANUFACTURER SPECIFICATIONS WILL BE

NON-RESPONSIVE AND NOT CONSIDERED.

(End of Summary of Changes)

File details come from the government source that posted it. Updated .