41238699 sow.pdf

PDF 471 KB Posted

Attached to
CONNECTOR, FO RECEP SS Federal contract opportunity
Solicitation number
SPMYM224Q1769
Issued by
Defense Logistics Agency Land and Maritime

About this file

This document is a Statement of Work (SOW) for the procurement of six Level 1 Fiber Optic Receptacle assemblies in accordance with Reference (A) by the original equipment manufacturer Teledyne/D.G. The contractor shall provide all material, labor, testing, and delivery services for the fabrication and delivery of the receptacles, which shall be terminated with a straight series 153 Monel connector and use Corning Clear Curve single mode fiber. The receptacles must meet specific optical, hydrostatic, and visual requirements. Objective Quality Evidence documentation is required as a deliverable, along with certifications and test reports. The receptacles will be delivered to the Puget Sound Naval Shipyard in Bremerton, Washington.

The related federal contract opportunity is a solicitation (SPMYM224Q1769) for a Fiber Optic Receptacle that will be issued as a 100% small business set-aside, sole source to Teledyne D.G. O'Brien. The contract will be a firm fixed-price supply contract for FOB Destination delivery to Bremerton, WA. Offerors must comply with NIST SP 800-171 requirements and provide specific information in their quotes, such as lead time, manufacturer, and country of origin.

View the file

Other files for this federal contract opportunity

Other files attached to CONNECTOR, FO RECEP SS, newest first.
File Type Posted
SPMYM224Q1769 13SEP24.pdf PDF
41238699 sow.pdf PDF
41238698 sow.pdf PDF
41238698 CDRL EXHIBIT C_Redacted.pdf PDF
SPMYM224Q1769 1 AUG 24.pdf PDF
41238698 sow.pdf PDF
41238699 CDRL EXHIBIT I_Redacted.pdf PDF
SPMYM224Q1769 EXTENDED.pdf PDF
41238698 CDRL EXHIBIT D_Redacted.pdf PDF
41238699 CDRL EXHIBIT I_Redacted.pdf PDF
41238699 sow.pdf PDF
41238698 CDRL EXHIBIT A_Redacted.pdf PDF
41238698 CDRL EXHIBIT C_Redacted.pdf PDF
41238698 CDRL EXHIBIT F_Redacted.pdf PDF
41238698 CDRL EXHIBIT G_Redacted.pdf PDF
41238699 CDRL EXHIBIT K_Redacted.pdf PDF
41238699 CDRL EXHIBIT L_Redacted.pdf PDF
41238699 CDRL EXHIBIT H_Redacted.pdf PDF
41238699 CDRL EXHIBIT N_Redacted.pdf PDF
41238698 sow.pdf PDF
41238698 tdp.pdf PDF
41238698 CDRL EXHIBIT E_Redacted.pdf PDF
41238699 CDRL EXHIBIT J_Redacted.pdf PDF
SPMYM224Q1769.pdf PDF
41238699 tdp.pdf PDF
41238698 ss_Redacted s.pdf PDF
41238699 ss_Redacted s.pdf PDF
41238698 CDRL EXHIBIT B_Redacted.pdf PDF
41238699 CDRL EXHIBIT M_Redacted.pdf PDF
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work

JML: KOI 00

Job Order: S Ship/Activity: FIBER OPTIC PENETRATOR RECEPTACLES Place of Performance: Vendor s Facility Period of performance: 202 TO 202

1. BACKGROUND: Puget Sound Naval Shipyard, and Intermediate Maintenance Facility (PSNS/IMF) Ocean Engineering Division (OED), requires the procurement of ( ) Level I Fiber Optic Receptacle assemblies in accordance with Reference (A) by the OEM manufacture Teledyne/D.G.

This SOW provides for the procurement of (6) each Level 1 Fiber Optic Receptacles IAW -172

(1535016-168 (RECEPTACLE) with (CAP)) and for the receipt of deliverables in support of that procurement. Receptacles shall be terminated with a straight series 153 Monel (QQ-N-281(D)- CL

-292 with a UPC polish) on the opposite end and shall be constructed using Corning Clear Curve single mode fiber.

Overall length shall be in accordance with (IAW) Reference (A). Each fiber optic receptacle shall be delivered with protective pressure proof c n P/N: 1534000-105, installed IAW Reference (A). Hydrostatic Test shall be IAW Reference (A) General Note 9. Optical requirements shall be IAW Reference (A), General Note 16.

SCOPE: The contractor shall provide all material, hazmat, labor services, test and inspection services, machine services and facilities for the fabrication and delivery of ( ) Level 1 Fiber Optic

1535016-172 (1535016-168 (RECEPTACLE) with (CAP)) and for the receipt of deliverables in support of that procurement. Receptacles shall be terminated with a straight series 153 Monel (QQ-N-281-

-292 with a UPC polish) on the opposite end and shall be constructed using Corning Clear Curve single mode fiber. Overall length shall be in accordance with (IAW) Reference (A). Each fiber optic receptacle shall be delivered with protective pressure proof c 1534000-105, installed IAW Reference (A). Hydrostatic Test shall be IAW Reference (A) General Note 9. Optical requirements shall be IAW Reference (A), General Note 16.

REFERENCES:

NAVSEA 302-7591113(B) SSN 688 CL/ 688I CL/ SSN21 CL/ NSSN CL TORPEDO TUBE FIBER

OPTIC PENETRATOR MK1

NAVSEA 0948-LP-045 7010

NAVSEA 0924-062-0010(C)

Paragraph 4.5.7

4. CONTRACTOR FURNISHED MATERIAL: Contractor is to furnish all supplies, material, labor, equipment, tooling, hazmat, and facilities necessary to complete the manufacture of ( ) each FIBER OPTIC RECEPTACLE ~ P/N: 1535016-172 (1535016-168 (RECEPTACLE) with

(CAP))

Each Fiber Optic Receptacle shall conform to Fabrication Notes as specified in Ref (A) for PC- 2 QQ- N-281(D)

5. DELIVERABLES:

* each Level 1 Fiber Optic Receptacles and each protective pressure proof caps IAW Reference (A) from Teledyne D.G.

FIBER OPTIC RECEPTACLE ~ P/N: 1535016-172 (1535016-168 (RECEPTACLE) with

(CAP))

*Furnish Objective Quality Evidence (OQE) for the Level 1 components of Reference (A).

*All MIC Level 1 material shall have identification, traceability, and control documentation.

*All Level I material shall comply with the identification marking, inspection, material testing, procurement, storage and documentation requirements of Reference B.

*The following shall be a part of the furnished OQE:

Serial number.

*On site testing inspection and over sight shall be performed by Defense Contract Management Agency (DCMA) at the vendor s facility.

*A copy of material chemical, physicals, and heat treatments certifications with a statement to the effect that objective evidence is on file in support of material identification and heat treatment, traceable from a unique serial number.

*O-ring sealing surfaces are free of imperfections and damage.

*Furnish Objective Quality Evidence for the following tests on each fiber optic receptacle assembly with DCMA oversite:

Visual Inspection of fiber optical receptacle for overall conformance to Reference (A) Sheet 11.

Pre-Hydrostatic Fiber Optic Receptacle optical performance shall be IAW Reference (A) General Note 16.

Hydrostatic pressure test Fiber Optic Receptacles open faced IAW Reference (A) General Note 9.

Post-Hydrostatic Fiber Optic Receptacle optical performance shall be IAW Reference (A) General Note 16.

Post-hydrostatic Return Loss test data (greater than or equal to 45 dB) for each receptacle measured at 1310nm and 1550nm wavelengths.

QUALITY ASSURANCE REQUIREMENTS: The following Certification records shall be supplied as a deliverable in conjunction with the each Fiber Optic Receptacles

DI-MISC 81020 (Certification Data for Non-Nuclear Level I Material) DI-QCIC-81110 (Inspection and Test Plan)

DI-MISC- (Pre-Hydrostatic est: Insertion Loss and Return Loss) DI-NDT1-80809B (Hydrostatic Pressure, Open Face) DI-MISC- (Post-Hydrostatic Test: Insertion Loss & Return Loss)

DI-NDTI-80809B (Test/Inspection Report Visual Inspection) DI-MISC-81356A (Certificate of Compliance)

PACKAGING: Completed Fiber Optic Receptacles shall be packaged as follows:

Each Fiber Optic Receptacle shall be enclosed in a transparent plastic bag. The assemblies shall be protected from damage during shipping per Reference B.

H 1

I 1 J 1

K L M N 1

SECURITY REQUIREMENTS: All references and deliverable items associated with this task are unclassified Distribution Statement D. Distribution authorized to DOD and DOD contractors only.

Contractors shall be registered in the Joint Certification Program (JCP) in order to receive unclassified technical data associated with this statement of work. There are no other known requirements for access to restricted areas or information connected with the performance of this task. Access to PSNS is not required for this work.

TRAVEL REQUIREMENTS: There are no known travel requirements

GOVERNMENT REPRESENTATIVE: , Code 127.2, (360) 627-51

Any items concerning contractual requirements or funding must be addressed to the Contracting Officer.

SHIPPING ADDRESS: Shipping address of acquisition materials for direct delivery, fastest means possible to DOD installation shall be to the following location:

Puget Sound Naval Shipyard 1400 Farragut Ave

Bldg. 514 Bremerton WA 98314

File details come from the government source that posted it. Updated .