JUSTIFICATION FOR SOLE SOURCE (SAP <$100k) Ref: FAR 13.106 and NAVSUP 4200.85D Chapter 5 Para. 2.b.(5)

The service or material listed on (Document number) 8094-3520,8094-3521,& 8094- 3522 is sole source and competition must be restricted to one source, or to only one brand name for reasons indicated below. There are no substitutes available for this material.

Restricted to the following source or brand name. Provide original manufacturer's name.

(If a sole source manufacturer distributes via dealers, ALSO provide dealer information.)

Manufacturer: Fluke Calibration (PRESSURE AND GAS FLOW CALIBRATION PRODUCTS) Manufacturer POC & Phone Nr. Larry Renda com: 602.773.4733 // cell: 602.757.9330 Mfr. Address 4765 EAST BEAUTIFUL LANE // PHOENIX, AZ 85044-5318 Manufacturers Dealer/Rep same as above Dealer/Rep Address/Phone Number same as above

_X Description of the item or service required, the estimated cost, and required delivery date.

One each Fluke model: 4322 Automated Pressure Calibrator (PRIMARY EFERENCE STANDAR a model 4322 Automated Pressure Calibrator.

_X Specific characteristics of the material or service that limit the availability to a sole source or particular brand name (unique features, function of the item, etc.).

Describe in detail why only this suggested source can furnish the requirements to the exclusion of other sources.

The Fluke model: 4322 Automated Pressure Calibrator is utilized in multiple Navy

Calibration Procedures for the calibration of a wide variety of pressure test measurement and diagnostic equipment (TMDE). The 4322 is listed as an authorized standard in NAVSEA OD 48939 Navy Calibration Equipment (NCE) Publication. IAW OPNAVINST 3960.16 para 6u, only equipment listed in the NCE can be used to perform calibrations. Fluke is the original equipment manufacturer and the only authorized manufacturer for this Automated Pressure Calibrator.

_X The requested material or service represents the minimum requirements of the Government

CHECK & FILL IN ALL APPLICABLE BLANKS BELOW

The material/service must be compatible in all aspects (form, fit and function) with existing systems presently installed. Describe the equipment you have now and how the new item/service must coordinate, connect, or interface with the existing system.

A patent, copyright, or proprietary data limits competition. The proprietary data is:

X These are “direct replacements” parts/components for existing brand name equipment.

X Other information to support a sole-source buy:

The sole source is submitted to ensure that exact model and MFR are purchased without substitution due to item end use being a calibration standard. Actual source of procurement is not being limited, only model and manufacturer. Fluke Model 4322, NSN 6695-01-654-0977 is shown as unavailable via Naval Stock System.

I CERTIFY THAT STATEMENTS CHECKED, AND INFORMATION PROVIDED ABOVE, ARE COMPLETE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND DO NOT CONTAIN CLASSIFIED INFORMATION. I UNDERSTAND THAT THE PROCESSING OF THIS SOLE-SOURCE JUSTIFICATION PRECLUDES THE USE OF FULL AND OPEN

COMPETITION.

Contracting Officer Signature FISCPS 4200/180 Rev 02/11/10

Date

JUSTIFICATION FOR SOLE SOURCE (SAP <$100k)
One each Fluke (cage 89536/4U744) model: 4322 Automated Pressure Calibrator (PRIMARY EFERENCE STANDARDS CALIBRATION SET). This model is listed in the NCE as a model 4322 Automated Pressure Calibrator. Cost each: $119774.62. RDD: 06 July 2018.
The Fluke model: 4322 Automated Pressure Calibrator is utilized in multiple Navy Calibration Procedures for the calibration of a wide variety of pressure test measurement and diagnostic equipment (TMDE). The 4322 is listed as an authorized standard in...
CHECK & FILL IN ALL APPLICABLE BLANKS BELOW
Activity: PSNS & IMF Shop 52 Title: Metrology Plannerman_
Date
2018-04-24T10:47:10-0700