MATERIAL ORDERING DATA
MIL-C-15726
IDN: N4523A 2060-1001
ICN: 38RTC16301 KO: S03 KOI: 004
Paragraph 6.2 Ordering Data
Preparer's note: Forgings previously procured to this specification are now procured to MIL- C-24679.
a. MIL-C-15726F, Copper-Nickel Alloy, Sheet, Plate, Strip, Bar, Rod and Wire dated 25 October 1988; including Amendment 1, dated 8 October 1991
b. Current issue of DODISS is to be cited in the solicitation.
c. Composition: Alloy C71500 (formerly 70-30) Form: plate Temper: M20-soft
d. Is a specific manufacturing technique required? If yes, specify: No
3.1 Unless otherwise specified, material shall be finished by such hot working, cold working, or heat treatment as may be necessary to meet the properties specified.
e. Dimensions: 1"thk, 80" x 83-5/8"
3.7 Unless otherwise specified, tolerances shall be specified in FED-STD-146.
3.7.1 When specified, tolerances shall be all plus or all minus.
f. Is alloy identity test required? No
3.9.2 When specified, each random mill length, prior to cutting to ordered length, and each forging shall be shown to be of the correct generic metallurgical group after final marking.
g. Is sampling for visual and dimensional inspections other than specified? If yes, specify: No
4.2.4 Sampling shall be as specified.
6.7 Unless otherwise specified (see 4.2.4), sampling should be in accordance MIL-STD-105, general inspection level II, acceptable quality level 1.5.
h. Is nondestructive inspection required? If yes, specify: No
4.2.5 Liquid penetrant inspection shall be in accordance with MIL-STD-271.
i. Is liquid penetrant inspection other than specified? If yes, specify: No
4.3.3.2 Liquid penetrant inspection shall be in accordance with MIL-STD-271. (Amendment 1)
j. Method used for alloy identity test: NA
4.5.1 Method of test for alloy identity shall be by an approved procedure.
k. Level of packing and packaging: C, Special marking is not required
5.1 The material shall be packaged to level A or C; packed to level A, B, or C, as specified and marked in accordance with MIL-C-3993.
Additional Data Requirements: NA Prepared By: Alexis Gahan
Code: 260.3
IDN: N4523A 2060-1002
ICN: 38RTC16301 KO: S03 KOI: 005
Paragraph 6.2 Ordering Data
Preparer's note: Forgings previously procured to this specification are now procured to MIL- C-24679.
a. MIL-C-15726F, Copper-Nickel Alloy, Sheet, Plate, Strip, Bar, Rod and Wire dated 25 October 1988; including Amendment 1, dated 8 October 1991
b. Current issue of DODISS is to be cited in the solicitation.
c. Composition: Alloy C71500 (formerly 70-30) Form: plate Temper: M20-soft
d. Is a specific manufacturing technique required? If yes, specify: No
3.1 Unless otherwise specified, material shall be finished by such hot working, cold working, or heat treatment as may be necessary to meet the properties specified.
e. Dimensions: 1"thk, 55" x 120"
3.7 Unless otherwise specified, tolerances shall be specified in FED-STD-146.
3.7.1 When specified, tolerances shall be all plus or all minus.
f. Is alloy identity test required? No
3.9.2 When specified, each random mill length, prior to cutting to ordered length, and each forging shall be shown to be of the correct generic metallurgical group after final marking.
g. Is sampling for visual and dimensional inspections other than specified? If yes, specify: No
4.2.4 Sampling shall be as specified.
6.7 Unless otherwise specified (see 4.2.4), sampling should be in accordance MIL-STD-105, general inspection level II, acceptable quality level 1.5.
h. Is nondestructive inspection required? If yes, specify: No
4.2.5 Liquid penetrant inspection shall be in accordance with MIL-STD-271.
i. Is liquid penetrant inspection other than specified? If yes, specify: No
4.3.3.2 Liquid penetrant inspection shall be in accordance with MIL-STD-271. (Amendment 1)
j. Method used for alloy identity test: NA
4.5.1 Method of test for alloy identity shall be by an approved procedure.
k. Level of packing and packaging: C, Special marking is not required
5.1 The material shall be packaged to level A or C; packed to level A, B, or C, as specified and marked in accordance with MIL-C-3993.
Additional Data Requirements: NA
IDN: N4523A 2060-1003
ICN: 38RTC16301 KO: S03 KOI: 003
Paragraph 6.2 Ordering Data
Preparer's note: Forgings previously procured to this specification are now procured to MIL- C-24679.
a. MIL-C-15726F, Copper-Nickel Alloy, Sheet, Plate, Strip, Bar, Rod and Wire dated 25 October 1988; including Amendment 1, dated 8 October 1991
b. Current issue of DODISS is to be cited in the solicitation.
c. Composition: Alloy C71500 (formerly 70-30) Form: plate Temper: M20-soft
d. Is a specific manufacturing technique required? If yes, specify: No
3.1 Unless otherwise specified, material shall be finished by such hot working, cold working, or heat treatment as may be necessary to meet the properties specified.
e. Dimensions: 1"thk, 80" x 120"
3.7 Unless otherwise specified, tolerances shall be specified in FED-STD-146.
3.7.1 When specified, tolerances shall be all plus or all minus.
f. Is alloy identity test required? No
3.9.2 When specified, each random mill length, prior to cutting to ordered length, and each forging shall be shown to be of the correct generic metallurgical group after final marking.
g. Is sampling for visual and dimensional inspections other than specified? If yes, specify: No
4.2.4 Sampling shall be as specified.
6.7 Unless otherwise specified (see 4.2.4), sampling should be in accordance MIL-STD-105, general inspection level II, acceptable quality level 1.5.
h. Is nondestructive inspection required? If yes, specify: No
4.2.5 Liquid penetrant inspection shall be in accordance with MIL-STD-271.
i. Is liquid penetrant inspection other than specified? If yes, specify: No
4.3.3.2 Liquid penetrant inspection shall be in accordance with MIL-STD-271. (Amendment 1)
j. Method used for alloy identity test: NA
4.5.1 Method of test for alloy identity shall be by an approved procedure.
k. Level of packing and packaging: C, Special marking is not required
5.1 The material shall be packaged to level A or C; packed to level A, B, or C, as specified and marked in accordance with MIL-C-3993.
Additional Data Requirements: NA