About this file
This document outlines the salient characteristics for a federal solicitation seeking upgrades to proprietary heat exchanger cleaning equipment. Key requirements include feeder protection modules, replacement fuses, an emergency stop retrofit, an automated tube cleaning arm, parallel controller operation, an AC power supply upgrade, communications hardware and software, and an improved lance feeder clamping system. Delivery is required by May 6, 2022. The solicitation will be issued on March 30 as a 100% small business set-aside and awarded as a firm fixed-price contract to the Defense Logistics Agency for use at Puget Sound Naval Shipyard. Offers must be submitted electronically by April 8 to be considered.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SPMYM2-22-Q-0964 (SOLICITATION) FEEDER PROTECTION MODULE.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Feeder Heater Protection Module
FOR CLINS 0001-0015
CLIN 0001: 2036-3750
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard.
This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment that has resulted in damage due to suspected stray current. This upgrade will fuse protect a path of potential stray current from the Terydon SHR-27 lance feeder to the Terydon LB-4M or LB-4M/ACC Lunch Box Controller.
• Works with proprietary Lunch Box Controllers
• Protects Units from stray voltage which may have damaged sensitive electronics in the past
• Connectors compatible with existing system or with intended design changes
• Fits into space available in LB-4M/LB-4M/ACC Controller box or on to the existing SHR-27 lance feeder
• Does not inhibit or interfere with the control signal path
• Sources readily available replacement part (consumable) fuses
CLIN 0002: 2036-3751
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard.
This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment that has resulted in damage due to suspected stray current. This upgrade will fuse protect a path of potential stray current from the SHR-27 lance feeder to the Terydon LB-4M or LB4M/ACC Lunchbox Control Module.
• Circuitry modifications to SHR-27 Lance Feeders required to work with Protection Module
• Protects Controller Units from stray voltage which may damage sensitive electronics
• Fits into space the available of the SHR-27 Lance Feeder Assembly
• Does not inhibit or interfere with the control signal path
CLIN 0003: 2036-3752
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard.
This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment that has resulted in damage due to suspected stray current. This upgrade will fuse protect a path of potential stray current from the Terydon SHR-27 lance feeder to the Terydon LB-4M or LB-4M/ACC Lunchbox Control Module.
• Replacement Fuse #1
• Consumable
• Spares
• Works specifically with the Protection Module
• Protects Units from stray voltage which may damage sensitive electronics
CLIN 0004: 2036-3753
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard.
This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment that has resulted in damage due to suspected stray current. This upgrade will fuse protect a path of potential stray current from the Terydon SHR-27 lance feeder to the Terydon LB-4M or LB-4M/ACC Lunchbox Control Module.
• Replacement Fuse #2
• Consumable
• Spares
• Works with Protection Module
• Protects Units from stray voltage which may damage sensitive electronics
CLIN 0005: 2036-3754
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard.
This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment that has resulted in damage due to suspected stray current. Terydon SHR-27 lance feeder to the Terydon LB-4M or LB-4M/ACC Lunchbox Control Module.
• Replacement Fuse #3
• Consumable
• Spares
• Works with Protection Module
• Protects Units from stray voltage which may damage sensitive electronics
CLIN 0006: 2036-3755
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard.
This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment that has resulted in damage due to suspected stray current. This upgrade will fuse protect a path of potential stray current from the Terydon SHR-27 lance feeder to the Terydon LB-4M or LB-4M/ACC Lunchbox Control Module.
• Replacement Fuse #4
• Consumable
• Spares
• Works with Protection Module
• Protects Units from stray voltage which may damage sensitive electronics
CLIN 0007: 2036-3756
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard.
This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment by improving safety. This upgrade will be installed in the existing Terydon LB-4M or LB-4M/ACC Lunchbox Controllers to add the ability to stop the Heat exchanger cleaning equipment quickly and positively in the case of emergency.
• Emergency Stop Retrofit to existing Government owned equipment
• Works with proprietary software running Lunchbox Controller units
• Fits within space envelope of Lunchbox Controller units
• Large Red stop button
• Necessary wiring to reach control circuitry from installation location
• Positively stops all operation when depressed
• Ruggedized for use in industrial environment
NOTE: Retrofit will be included standard on all subsequent procurements of this model equipment
CLIN 0008: 2036-3757
This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment. The arm is a newly developed automated smart tool and is necessary to clean the various unique exchanger patterns. This arm is required to convert the currently owned X-Y indexer, used in a specific condenser, into the STI-HD-UM, Universal Main cleaning system. The STI-HD-UM is capable of cleaning 100% of the tubes in a specific condenser without using the Terydon Rotary Indexer. This upgrade will bring Puget Sound Naval Shipyard STI-HD up to the same standard as the improved Norfolk Naval Shipyard equipment specifications ie. STI-
HU-UM.
• Remote condenser tube cleaning
• Operates in Wet, Confined, Industrial Environment
• Automatically navigate hole to hole indexing during tube cleaning
• Utilizes both Cartesian and Polar coordinate locating / indexing systems
• Compatible with 4 automated tool path programs
• Works with existing SHR-27 single lance feeder
• Supports automatic feeding of lance during cleaning operations
• Works with existing STI-HD-UM X-Y Indexing equipment
• Works with existing LB-4M and future LB-4M/ACC Lunchbox controller units
• Space envelope supports use on all tubes in a main condenser unit
• Allows 100% of the tubes to be cleaned with automated program.
• Capable of cleaning up to or more than 600 tubes in a shift while operating at peak performance
• Updated propriety software upgrade to the latest operating release required to operate
CLIN 0009: 2036-3758
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard.
This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment. This upgrade will add the ability run parallel Heat exchanger cleaning equipment lunchbox control units at the same time.
• Connects with Terydon LB-4M or LB-4M/ACC Lunchbox Controller units
• Works with proprietary software running controller unit
• Communications Hub must meet electrical Safety requirements
• Communications Hub must be approved by Local IT department for use in Shipyard
• Must not cause radio frequency interference
• Ruggedized for industrial environment
CLIN 0010: 2036-3759
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard.
This upgrade will eliminate the battery, which prohibits uninterrupted operation due to charge depletion.
• Works to convert an LB-4M Lunch Box Controller into an LB-4M/ACC Lunch Box Controller
• 110v Grounded Plug
• UL or NRTL listing approval
• Ruggedized for industrial environments
CLIN 0011: 2036-3760
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard. This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment by updating to the latest version. This upgrade will add the ability to connect the Communications Hub to the LB-4M and LB-4M/ACC Lunch Box Controllers.
• Cable Connects to Communications Hub
• Cable connects to LB-4M and LB-4M/ACC Lunchbox Controller
• Ruggedized for industrial environment
CLIN 0012: 2036-3761
Specifications:
• Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard. This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment by updating to the latest version. This upgrade will add the ability to connect the communications Hub to the LB-4M or LB-4M/ACC Lunch Box Controller
• Cable Connects to Communications Hub
• Cable connects to LB-4M or LB-4M/ACC Lunchbox Controller
• Ruggedized for industrial environment
CLIN 0013: 2036-3762
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard. This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment by updating to the latest version. Lunchbox smart controller circuitry required to run propriety commercial software for use with automated heat exchanger cleaning equipment.
• Compatible with LB-4M or LB-4M/ACC Lunchbox Controller units
• Installs in available space in LB-4M or LB-4M/ACC Lunchbox controller
• Works with the proprietary software running controller unit
• Circuitry must meet electrical Safety requirements
• Circuitry must be approved by Local IT department for use in Shipyard
• Must not cause radio frequency interference
• Ruggedized for industrial environment
CLIN 0014: 2036-3763
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard. This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment by updating to the latest version. This upgrade will increase reliability by adding the ability to connect a windows based tablet using proprietary commercial software to the Communications Hub via wired connection rather than by blu-tooth.
• Compatible with the hardware in the LB-4M Lunchbox Controller units
• Works with proprietary software (current or future) running the Lunchbox controller units
• Adapter must meet electrical Safety requirements
• Adapter must be approved by Local IT department for use in Shipyard
• Must not cause radio frequency interference
• Ruggedized for industrial environment
Supports Cat 5 Cable
CLIN 0015: 2036-3764
Specifications:
Specifications:
Upgrades to existing PSNS Government owned equipment, to bring up to date with improvements added to those units recently procured by Norfolk Naval Shipyard. This upgrade is to resolve issues specific to Government use of Proprietary Heat Exchanger Cleaning equipment by updating to the latest version. This upgrade improves operation, and maintenance with advancements in safety for the operator and increased efficiency of the Terydon SHR-27 lance feeder with reduced risk of damage to the lance and lance feeder.
• Works exclusively with the lance feeder.
• Updates lance feeder clamping system to the newest design.
• Fits into existing SHR-27 lance feeder with no modification.
• Does not require extensive retraining to incorporate new design.
• Extends service life of lance.
• Interchangeable design allowing for use with single or dual lance feeder.
• Allows for easier install of the lance into the SHR-39 Lance Feeder.
• Aligns both the SHR-27 and SHR-39 Lance installation method.