ORDERING SPECIFICATIONS FOR 4/0 HEAVY DUTY 600 VOLT
WELDING CABLE
DOCUMENT # 1065-3346
• MUST BE APPROVED/CERTIFIED BY A NATIONALY APPROVED TESTING
LABORATORY
• MUST BE # 34 AWG BUNCH STRANDED ROPE LAY COPPER TO REDUCE WIRE
FATIGUE, IMPROVE FLEXABILITY AND INCREASE IMPACT RESISTANCE
• MUST HAVE 100% FABRIC SERVE BETWEEN WIRE AND INSUALTION JACKET
• JACKET MUST BE ON "SUPER-TREX TSE" MATERIAL OR EQUAL AND MUST BE
FLAME/HEAT RESISTANT AND RESISTANT TO SOLVENTS AND CHEMICALS
• COPPER CABLE SHALL NOT TWIST INDEPENDENT OF JACKET CAUSING
"BUNCHING" ON CABLE JACKET BOUNDARY
• AVERAGE JACKE THICKNESS MUST BE 0.158"
• NOMINAL CABLE O.D. 0.900"
• JACKET AND CABLE CONNECTOR COVER MUST BE RED IN COLOR
• MUST BE PRIVATE PERMANENT INK BRANDED "PSNS PROPERTY SHOP 26"
INTERMITTENTLY DOWN LENGTH OF CABLE ALONG WITH DATE OF PRINTING
• CAM-LOC CABLE CONNECTORS MUST BE SOLDERED TO CABLE. MALE/FEMALE
CAMLOC CABLE CONNECTORS SHALL HAVE TAPER NOSE COVERS MOLDED TO
WELD CABLE
• CABLE SHALL BE SUBJECTED TO MECHANICAL, CHEMICAL, ENVIRONMENTAL
AND OPERATIONAL TESTING COMMON TO INDUSTRIAL SHIP BUILDING/REPAIR
ENVIRONMENTS.
• MUST HAVE MINIMUM BEND RADIUS OF 7.2 INCHES
• CABLE JACKET WILL MAINTAIN INTEGRITY WHEN FLEXED AT -20 DEGREE
TEMPERATURES
• MUST BE 4/0 AWG/ 600 VOLT WELDING CABLE
• CABLE SHOULD RESIST CHEMICALS THAT INCLUDE BUT NOT LIMITED TO, SALT
WATER, ACIDS, JET FUEL, PAINT, TURPENTINE, KEROSENE, HYDROCLORIC
CHEMICALS AND GASOLINE
File details come from the government source that posted it. Updated .