Salient Characteristics for a Vertical Dynamometer
Project # 012-330 10 Aug 20
1. One (1) - Vertical Dynamometer (EC Dyno Vertical Fixture, Taylor Dynamometer (now referred to as PTDSUBCO, LLC), Item #00013500001 or equivalent) to include the following minimum/equal features:
a. DM-8100 dry gap dynamometer mounted vertical shaft up in a vertical base assembly.
b. A mechanical actuator system raises and lowers the DUT mounting fixture manually.
c. The fixture will have guards on all four sides. Water piping with safeties is included.
d. Calibration arm, weight hanger, weights, and pulley system are included for dead weight calibration: A load cell connected to the dynamometer measures torque and a 60 tooth gear and magnetic pickup measures speed.
e. Dimensions to be similar to DM-8120 vertical stand per 6523 assembly and 16172-OUT-001.
f. Dyno shall utilize 20 gpm of cooling water (water source provided by the government) with an inlet temp. of no greater than 90 deg. F.
g. 200hp @ 1800 rpm, 6000 rpm max. speed
2. One (1) Controller (Inter-Loc V Multi-Loop Closed Loop Controller (Base Unit Only), Taylor Dynamometer (now referred to as PTDSUBCO, LLC), Item #OIL5-STD-02 or equivalent) to include the following minimum/equal features:
a. Modular design, with three slots for dyno or throttle cards
b. Advanced graphical tuning display
c. Precise speed and torque control
d. Updates all control loops 500 times per second
e. Programmable Digital Inputs and Outputs
3. One (1) Operator Control Station (IL5 Operator Control Station (OCS) v4, Windows 10, Taylor Dynamometer (now referred to as PTDSUBCO, LLC), Item #0IL5-OCS-04 or equivalent)
4. One (1) Dyno Controller Kit (Inter-Loc V Dyno Controller Kit, Taylor Dynamometer (now referred to as PTDSUBCO, LLC), Item #0IL5-DYNO-01 or equivalent)
5. One (1) Eddy Current Power Amplifier Unit (PAU) (Eddy Current PAU,6 Amp, Rack Mnt, Std Temp, Fused for 240 P, 240 S, 200VDC Out, 1.5 KVA XFRMR, 60 HZ, Taylor Dynamometer (now referred to as PTDSUBCO, LLC, Item #0ECPAU015RS-GGC6 or equivalent)
6. One (1) Rack Mount (Taylor Dynamometer (now referred to as PTDSUBCO, LLC), Item #00013500002 or equivalent)
7. Asbestos – No asbestos products/materials shall be used in any components (i.e. gaskets, etc.) of the equipment. The equipment shall be asbestos free.
8. Removal/Installation Services - The contractor shall provide all personnel and supplies to disconnect the existing dynamometer, all associated equipment, securing devices (including clamps and bolts), and the new specified equipment and all associated equipment shall be assembled, installed, calibration, set-up and tested by the contractor. The contractor shall provide all personnel, and supplies necessary for the complete installation and set-up of the proposed system. The contractor shall completely level the machine prior to any operational testing and training described herein. (NOTE: The government shall provide forklift and utilities (power and water) disconnection/connection services.)
9. On-Site Operator/Maintenance Training – On-Site, 8 hours/one day minimal
10. Three (3) hard copies of Operator Manuals – Which shall include detailed instructions on how to operate the software, etc. Operator / Maintenance / Repair Manuals - The equipment shall be furnished with three (3) hard copies of the manufacturer’s standard Operation, Maintenance, and Repair Manual(s), bound in durable three ring binder(s). The manuals shall include all mechanical and electrical schematics showing discrete components/block diagrams/wiring diagrams with inputs and outputs identified/system electrical interface documents and drawings for the specific model of all machine equipment/drives/controls supplied. The information contained in the manual(s) shall reflect the unit and its components in the “as built” configuration. The information contained in the manual(s) shall be adequate to permit trouble shooting and repair of the equipment by journeymen level personnel. The information contained in the manual(s) shall be in the English language. The information contained in the manual(s) shall be in imperial units of measure. The vendor shall provide a “no asbestos used” statement, certifying that all products/materials (i.e. gaskets, etc.) used in the components of the equipment does not contain asbestos, as outlined in paragraph 6. The contractor shall provide a list of recommended consumable spare parts and possible sources for procurement.
11. NRTL Certification Report - This includes the equipment and its component parts shall be in compliance with applicable Code of Electrical Regulations (CFR) Title 29, Part 1910. By definition, any equipment will be deemed acceptable and approved by TRF, Bangor, if it meets specific Occupational Safety and Health Administration (OSHA) conditions outlined in CFR Title 29, Part 1910; Subparts "O" and "S". Specifically, equipment will be "Accepted" by TRF, Bangor, if it has been inspected and found by a Nationally Recognized Testing Laboratory (NRTL) to conform to specified plans or procedures of applicable codes. The equipment (as a whole system) shall be Nationally Recognized Testing Laboratory (NRTL) inspected and certified (by an OSHA authorized third party). One (1) “hard” copy of the NRTL certification report shall be provided. If the equipment type/model has already been NRTL inspected and certified, a certification report (one (1) “hard” copy) or documentation mounted on the equipment, (which acknowledges it is NRTL certified), shall be provided.
12. Warranty - The warranty period shall be for one year. Supplies and services furnished shall be covered by warranty from defects in design, materials and workmanship. The warranty shall be the manufacturer’s standard commercial warranty, which shall conform to all the requirements of the contract. Acceptance of the manufacturer’s standard commercial warranty shall not minimize the rights of the government under clauses in the contract, and in any conflict that arises between the terms and conditions of the contract and manufacturer’s warranty, the terms and conditions of the contract shall take precedence. The warranty period shall commence from the date of acceptance. All warranty work shall be provided by a factory authorized distributer.
13. Admittance To The Work Site - Upon contract award, employees or representatives of the Contractor who require access to the Receiving Activity's facility at Naval Base Kitsap, Bangor (NBK, Bangor) shall be admitted to the work site only after they have been issued an appropriate Naval Region NW visitor security badge which is obtained at NBK, Bangor Pass & ID Office (located outside the NBK, Bangor Trident/ Main Gate).
Navy Region NW badge is required to gain access through the Operational Area Gate, or Waterfront Restricted Area, and is obtained through the on-line Base Authorization and Visit Request (BAVR) computer system. The prime contractor will need to submit all badge requests for their personal and for sub-contractor personnel. To request a Navy Region NW badge, Go on line to "https://www.bavr.cnic.navy.mil, and submit a request for a badge, a minimum of five (5) business days prior to arrival. All requested information highlighted in red is mandatory. Type N/A for “Driver’s License Information”. The "Command you are visiting" is: “Trident Refit Facility (TRF)” (or "NBK Bangor"). The “Company Name or Command” and “Work Phone” is your company/command information. The “Originating Command Security Officer Information” is Bruce Girkin, bruce.girkin@navy.mil. The "Sponsor E-Mail" for an on-line badge should be: aaron.k.peal@navy.mil (Aaron Peal, 360-315-1047, 360-471-8624 (cell)). In the "Purpose of Visit" box, please explain in detail the purpose of your visit, and include the Contract Number, the Receiving Activity Point of Contact (name and telephone number) and ALL the buildings/areas/piers you are visiting. The “Start Date” is the day you expect to pick up your badge (you cannot pick it up early, even if approvals are completed). The “End Date” is the last date of your visit. Also send a copy of the contract (or contract modification if the delivery date has been changed) to Aaron Peal at the e-mail address listed above. You will be notified at the e-mail address you provided, when all approvals have been completed. If the BAVR computer system doesn't work, try different search engines (“Firefox” search engine seems to work the best). If BAVR still doesn’t work contact the Receiving Activity Point of Contact or our security manager, Aaron Peal, 360-315-1047, 360-471-8624 (cell) to schedule a visit(s), and shall provide the following information:
* Full Legal Name
* US Citizen Status
* All Company Contact Information
* Contract Number
Visitors must show proof of US Citizenship (at the NBK Bangor Pass & ID Office, located outside Bangor’s Main Gate (Trident Boulevard), by having an original active US Passport, an "Enhanced Driver's License", or an unlamented official birth certificate.
| Salient Characteristics for a |
| 1. One (1) - Vertical Dynamometer (EC Dyno Vertical Fixture, Taylor Dynamometer (now referred to as PTDSUBCO, LLC), Item #00013500001 or equivalent) to include the following minimum/equal features: |
| a. DM-8100 dry gap dynamometer mounted vertical shaft up in a vertical base assembly. |
| b. A mechanical actuator system raises and lowers the DUT mounting fixture manually. |
| c. The fixture will have guards on all four sides. Water piping with safeties is included. |
| d. Calibration arm, weight hanger, weights, and pulley system are included for dead weight calibration: A load cell connected to the dynamometer measures torque and a 60 tooth gear and magnetic pickup measures speed. |
| e. Dimensions to be similar to DM-8120 vertical stand per 6523 assembly and 16172-OUT-001. |
| f. Dyno shall utilize 20 gpm of cooling water (water source provided by the government) with an inlet temp. of no greater than 90 deg. F. |
| g. 200hp @ 1800 rpm, 6000 rpm max. speed |
| 2. One (1) Controller (Inter-Loc V Multi-Loop Closed Loop Controller (Base Unit Only), Taylor Dynamometer (now referred to as PTDSUBCO, LLC), Item #OIL5-STD-02 or equivalent) to include the following minimum/equal features: |
| a. Modular design, with three slots for dyno or throttle cards |
| b. Advanced graphical tuning display |
| c. Precise speed and torque control |
| d. Updates all control loops 500 times per second |
| e. Programmable Digital Inputs and Outputs |
| 3. One (1) Operator Control Station (IL5 Operator Control Station (OCS) v4, Windows 10, Taylor Dynamometer (now referred to as PTDSUBCO, LLC), Item #0IL5-OCS-04 or equivalent) |
| 4. One (1) Dyno Controller Kit (Inter-Loc V Dyno Controller Kit, Taylor Dynamometer (now referred to as PTDSUBCO, LLC), Item #0IL5-DYNO-01 or equivalent) |
| 5. One (1) Eddy Current Power Amplifier Unit (PAU) (Eddy Current PAU,6 Amp, Rack Mnt, Std Temp, Fused for 240 P, 240 S, 200VDC Out, 1.5 KVA XFRMR, 60 HZ, Taylor Dynamometer (now referred to as PTDSUBCO, LLC, Item #0ECPAU015RS-GGC6 or equivalent) |