SPMYM2-20-Q-2842 (SALIENT CHARACTERISTICS) GRADE A TEST STAND.pdf

PDF 153 KB Posted

Attached to
GRADE A TEST STAND Federal contract opportunity
Solicitation number
SPMYM2-20-Q-2842
Issued by
Defense Logistics Agency Land and Maritime

View the file

Other files for this federal contract opportunity

Other files attached to GRADE A TEST STAND, newest first.
File Type Posted
SPMYM2-20-Q-2842 (TEST SYSTEM SPECIFICATIONS) GRADE A TEST STAND.pdf PDF
SPMYM2-20-Q-2842 (SOLICITATION) GRADE A TEST STAND.pdf PDF
SPMYM2-20-Q-2842 (SSJA-REDACTED) GRADE A TEST STAND.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics for a Valve Grade “A Test Stand

Project #994-320 10 Aug 20

1. One (1) Valve Grade “A” Test Stand, Calder/Climax, Manufacturer Part #HPC 6K to include the following minimum (or equal) machine performance ranges (+/- 10%):

a. Hydrostatic pressure: 300 – 5,700 psi

b. Low-pressure air: 5 – 125 psi

c. Air pilot actuation pressure: 5 -125 psi

d. Vacuum pilot actuation pressure: 0 -28 inHD (vacuum)

e. Quick fill: 3 GPM

f. Water inlet pressure: 50 psi recommended; 70 psi maximum; 25 psi minimum

g. Gauge accuracy, analog: 0.5 F.S.

h. Gauge accuracy, digital: 0.25 F.S.

i. System pressure decay: 100 psi/ 10 minutes maximum – block valve to outlet port

j. Hydrostatic test media: Water, Glycol, Water / soluble oil blends

k. Shop air requirement: 40 scfm @ 100 – 150 psi

l. Water requirement: 3 GPM minimum @ 50 psi/ 5 GPM @ 50 psi

m. Pump lubrication requirement: General purpose air tool oil, 25 -30 pump stokes per drop)

n. The following spare parts shall be provided:

i. Water inlet filtration; 125 micron, Qty: 1

ii. Water outlet filtration: 7 micron, Qty: 1

iii. Air filter cartridge; 40 micron, Qty: 1

iv. Vacuum filter cartridge; 10 micron, Qty: 1

2. Asbestos – No asbestos products/materials/spare parts shall be used in any components (i.e. gaskets, etc.)

of the equipment. The equipment shall be asbestos free.

3. Contractor Commissioning Services to be provided - The specified equipment and all associated equipment shall be commissioned by the contractor. This includes ensuring the Valve Test Stand was installed properly by the government, and is operational prior to operational testing and training. The contractor shall provide all personnel, test equipment, supplies, etc. necessary for the complete commissioning of the proposed system.

4. On-Site Operator/Maintenance Training – On-Site, 8 hours/one day minimal

5. Three (3) hard copies of Operator Manuals – Which shall include detailed instructions on how to operate the software, etc. Operator / Maintenance / Repair Manuals - The equipment shall be furnished with three (3) hard copies of the manufacturer’s standard Operation, Maintenance, and Repair Manual(s), bound in durable three ring binder(s). The manuals shall include all mechanical and electrical schematics showing discrete components/block diagrams/wiring diagrams with inputs and outputs identified/system electrical interface documents and drawings for the specific model of all machine equipment/drives/controls supplied. The information contained in the manual(s) shall reflect the unit and its components in the “as built” configuration. The information contained in the manual(s) shall be adequate to permit trouble shooting and repair of the equipment by journeymen level personnel. The information contained in the manual(s) shall be in the English language. The information contained in the manual(s) shall be in imperial units of measure. The vendor shall provide a “no asbestos used” statement, certifying that all products/materials (i.e. gaskets, etc.) used in the components of the equipment does not contain asbestos, as outlined in paragraph 6. The contractor shall provide a list of recommended consumable spare parts and possible sources for procurement.

6. Warranty - The warranty period shall be for two (2) years. Supplies and services furnished shall be covered by warranty from defects in design, materials and workmanship. The warranty shall be the manufacturer’s standard commercial warranty, which shall conform to all the requirements of the contract. Acceptance of the manufacturer’s standard commercial warranty shall not minimize the rights of the government under clauses in the contract, and in any conflict that arises between the terms and conditions of the contract and manufacturer’s warranty, the terms and conditions of the contract shall take precedence. The warranty period shall commence from the date of acceptance. All warranty work shall be provided by a factory authorized distributer.

7. Admittance To The Work Site - Upon contract award, employees or representatives of the Contractor who require access to the Receiving Activity's facility at Naval Base Kitsap, Bangor (NBK, Bangor) shall be admitted to the work site only after they have been issued an appropriate Naval Region NW visitor security badge which is obtained at NBK, Bangor Pass & ID Office (located outside the NBK, Bangor Trident/ Main Gate).

Navy Region NW badge is required to gain access through the Operational Area Gate, or Waterfront Restricted Area, and is obtained through the on-line Base Authorization and Visit Request (BAVR) computer system. The prime contractor will need to submit all badge requests for their personal and for sub-contractor personnel. To request a Navy Region NW badge, Go on line to "https://www.bavr.cnic.navy.mil, and submit a request for a badge, a minimum of five (5) business days prior to arrival. All requested information highlighted in red is mandatory. Type N/A for “Driver’s License Information”. The "Command you are visiting" is: “Trident Refit Facility (TRF)” (or "NBK Bangor"). The “Company Name or Command” and “Work Phone” is your company/command information. The “Originating Command Security Officer Information” is Bruce Girkin, bruce.girkin@navy.mil. The "Sponsor E-Mail" for an on-line badge should be: aaron.k.peal@navy.mil (Aaron Peal, 360-315-1047, 360-471-8624 (cell)). In the "Purpose of Visit" box, please explain in detail the purpose of your visit, and include the Contract Number, the Receiving Activity Point of Contact (name and telephone number) and ALL the buildings/areas/piers you are visiting. The “Start Date” is the day you expect to pick up your badge (you cannot pick it up early, even if approvals are completed). The “End Date” is the last date of your visit. Also send a copy of the contract (or contract modification if the delivery date has been changed) to Aaron Peal at the e-mail address listed above. You will be notified at the e-mail address you provided, when all approvals have been completed. If the BAVR computer system doesn't work, try different search engines (“Firefox” search engine seems to work the best). If BAVR still doesn’t work contact the Receiving Activity Point of Contact or our security manager, Aaron Peal, 360-315-1047, 360-471-8624 (cell) to schedule a visit(s), and shall provide the following information:

* Full Legal Name

* US Citizen Status

* All Company Contact Information

* Contract Number

Visitors must show proof of US Citizenship (at the NBK Bangor Pass & ID Office, located outside Bangor’s Main Gate (Trident Boulevard), by having an original active US Passport, an "Enhanced Driver's License", or an unlamented official birth certificate.

Salient Characteristics for a
1. One (1) Valve Grade “A” Test Stand, Calder/Climax, Manufacturer Part #HPC 6K to include the following minimum (or equal) machine performance ranges (+/- 10%):
a. Hydrostatic pressure: 300 – 5,700 psi
b. Low-pressure air: 5 – 125 psi
c. Air pilot actuation pressure: 5 -125 psi
d. Vacuum pilot actuation pressure: 0 -28 inHD (vacuum)
e. Quick fill: 3 GPM
f. Water inlet pressure: 50 psi recommended; 70 psi maximum; 25 psi minimum
g. Gauge accuracy, analog: 0.5 F.S.
h. Gauge accuracy, digital: 0.25 F.S.
i. System pressure decay: 100 psi/ 10 minutes maximum – block valve to outlet port
j. Hydrostatic test media: Water, Glycol, Water / soluble oil blends
k. Shop air requirement: 40 scfm @ 100 – 150 psi
l. Water requirement: 3 GPM minimum @ 50 psi/ 5 GPM @ 50 psi
m. Pump lubrication requirement: General purpose air tool oil, 25 -30 pump stokes per drop)
n. The following spare parts shall be provided:
i. Water inlet filtration; 125 micron, Qty: 1
ii. Water outlet filtration: 7 micron, Qty: 1
iii. Air filter cartridge; 40 micron, Qty: 1
iv. Vacuum filter cartridge; 10 micron, Qty: 1

File details come from the government source that posted it. Updated .