N4215813438189
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
I. This modification is to:
1. UPDATE CLIN 0001 ORDERING DATA/ACQUISITION REQUIREMENTS FOR MIL-E-23765/3A ELECTRODES 1.(c) FROM Type: CuNiAI Form 6 Size: 1/8” Diameter TO Type: CuNiAI Form 6 Size: 3/32” Diameter
2. EXTEND SOLICITATION END DATE TO FEBRUARY 23,2022 1600.
II. All other terms and conditions are the same.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 14-Feb-2022
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X SPMYM122Q0054
X 9B. DATED (SEE ITEM 11)
08-Feb-2022
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
14-Feb-2022
CODE
DLA MARITIME NORFOLK
TED HALLIDAY
CODE NMAB B6
(757) 396-8064
PORTSMOUTH VA 23709-5000
SPMYM1 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
SPMYM122Q0054
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 14-Feb-2022 04:00 PM to 23-Feb-2022 04:00 PM.
SUPPLIES OR SERVICES AND PRICES
CLIN 0001
The CLIN extended description has changed from:
ROD, WELDINGMIL-E-23765B/3A FORM 6 TYPE MI=CUNIAL 3/32” DIAMETER TIG WIREAUL #
3439HMCN15043NSN: 9B 3439-HM-CN1-5043 ITEM: WELD ROD STRAIGHT 3/32”a) All material for this line item must be marked and identified clearly on each individual container and LABEL IAW CFR29.1910.1200.
MUST NOT CONTAIN “METHYLENE CHLORIDE” b) The manufacturer: WISCONSIN WIRE WORKS INC and product: NICKEL BRONZE WELD, C63280 (COPPER AND BRASS WELDING ALLOYS, WELDING ROD/NICKEL, P/N: 63209350/ 3/32”, 50 LB BOX on attached JML has been approved for use at Norfolk Naval Ship Yard. The above manufacture and product AUL#’s are, 9B 3439-HM-CN1-5043 SHELF LIFE: 0-00OQE ORDERING REQUIREMENTS FOR CIM Provide written verification that the chemical and mechanical properties have been determined and are acceptable IAW the required specification MIL-E-23765B as applicable for Document# 1343-8189. a.) Provide written verification that the chemical analysis and mechanical properties tests have been determined and are acceptable. All test reports will contain a signed certification that the results represent the actual values for the material provided and that they are in full compliance with the contract specification.
Material certification data shall be recorded on the testing company's letterhead and shall bear the name, title and signature of the authorized company representative. The name and title shall be clearly legible. Certification data supplied to the government shall be either the original mill material certification, the original copy from the testing facility, or exact photocopies of these documents. The data forwarded by the manufacturer shall contain a signed certification that the reported results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Statements on material certification documents must be positive and unqualified. The material certification data reports shall include quantitative data representing the actual values obtained during testing. b.) Test reports will list all verified attributes and will be traceable to the material via a heat, lot, or batch number applied to the material by the manufacturer. Each piece of material must be marked with the applicable heat, lot, or batch number shown on the test reports provided. In the case of a finished product identified by a lot number manufactured from a start material identified by a heat number, the final test reports performed on the finished product samples shall be marked with the lot number. The test reports for the raw material shall be marked with the heat number of that material.c.) Test reports labeled "Typical," those with words such as "to the best of our knowledge" or "we believe the information contained herein is true" or those that have results transcribed from other reports or documents, or test reports with the heat/lot/batch number information handwritten on them are not acceptable. d.) Test reports for loose MIL-DTL-1222, K-Monel (QQ-N- 286), fasteners and for all assemblies which contain MIL-DTL-1222 K-Monel fasteners, shall include a certification statement describing the forming process used to manufacture the fasteners (i.e. hot headed with cold rolled threads, hot headed with machined threads, etc.), the heat treatments performed, and the order in which these actions were performed (i.e., fasteners manufactured and then solution annealed and age hardened, etc.). This action is required to ensure compliance with MIL-DTL-1222, paragraph 3.3.4, which requires fasteners with formed heads (i.e., hot headed, cold headed, etc.) and rolled threads to be solution annealed and age hardened after the manufacturing process. e.) Certifications for QQ-N-286 Rev G materials shall show that slow strain rate tensile SSRT test of "start material" has been accomplished per QQ-N-286 Rev G requirements. f.) Where headed fastener specifications require a yield strength test AND a wedge tensile test, a separate (new, untested) fastener is required for each of the two test methods, and both of these tests shall be reported. This does not apply to steel hex head fasteners (grades 2, 5, 8, B7, and B16) are certified to a proof load and NOT yield strength; therefore, this issue does NOT apply to those fasteners. NOTE: This does apply to All CRES and non-ferrous bolts and screws, and ALL steel socket head cap screws (grade A574 and 4340). Wedge tensile test a required test for including ones that had their yield strength and tensile strength certified by alternative testing IAW MIL-DTL-1222.ORDERING DATA/ACQUISITION REQUIREMENTS FOR MIL-E-23765/3A ELECTRODES: 1. All diameters of CuNiAI Welding, Bare, and Solid Copper Alloyed Cored Electrodes shall be ordered in accordance with reference (a) shall include the following acquisition requirements. (a) Military Specification, Electrode and Rods- Welding, Bare, Solid Copper Alloyed Cored, General Specification For; MIL-E-23765B (SH) AMENDMENT 1, 15 September 1989 (b) Electrode and Rods- Welding, Bare, Solid Copper Alloy; MIL-E-23765/3A (SH) 11 March 1986 (c) Type; CuNiAI Form 6 Size:
1/8" Diameter (d) First article inspection is not required (e) Alloy Identity testing is not required (f) N/A (g) Level C packaging is required (h) Additional special marking is not required
To:
ROD, WELDINGMIL-E-23765B/3A FORM 6 TYPE MI=CUNIAL 3/32” DIAMETER TIG WIREAUL #
3439HMCN15043NSN: 9B 3439-HM-CN1-5043 ITEM: WELD ROD STRAIGHT 3/32”a) All material for this line item must be marked and identified clearly on each individual container and LABEL IAW CFR29.1910.1200.
MUST NOT CONTAIN “METHYLENE CHLORIDE” b) The manufacturer: WISCONSIN WIRE WORKS INC and product: NICKEL BRONZE WELD, C63280 (COPPER AND BRASS WELDING ALLOYS, WELDING ROD/NICKEL, P/N: 63209350/ 3/32”, 50 LB BOX on attached JML has been approved for use at Norfolk Naval Ship Yard. The above manufacture and product AUL#’s are, 9B 3439-HM-CN1-5043 SHELF LIFE: 0-00OQE ORDERING REQUIREMENTS FOR CIM Provide written verification that the chemical and mechanical properties have been determined and are acceptable IAW the required specification MIL-E-23765B as applicable for Document# 1343-8189. a.) Provide written verification that the chemical analysis and mechanical properties tests have been determined and are acceptable. All test reports will contain a signed certification that the results represent the actual values for the material provided and that they are in full compliance with the contract specification.
Material certification data shall be recorded on the testing company's letterhead and shall bear the name, title and signature of the authorized company representative. The name and title shall be clearly legible. Certification data supplied to the government shall be either the original mill material certification, the original copy from the testing facility, or exact photocopies of these documents. The data forwarded by the manufacturer shall contain a signed certification that the reported results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Statements on material certification documents must be positive and unqualified. The material certification data reports shall include quantitative data representing the actual values obtained during testing. b.) Test reports will list all verified attributes and will be traceable to the material via a heat, lot, or batch number applied to the material by the manufacturer. Each piece of material must be marked with the applicable heat, lot, or batch number shown on the test reports provided. In the case of a finished product identified by a lot number manufactured from a start material identified by a heat number, the final test reports performed on the finished product samples shall be marked with the lot number. The test reports for the raw material shall be marked with the heat number of that material.c.) Test reports labeled "Typical," those with words such as "to the best of our knowledge" or "we believe the information contained herein is true" or those that have results transcribed from other reports or documents, or test reports with the heat/lot/batch number information handwritten on them are not acceptable. d.) Test reports for loose MIL-DTL-1222, K-Monel (QQ-N- 286), fasteners and for all assemblies which contain MIL-DTL-1222 K-Monel fasteners, shall include a certification statement describing the forming process used to manufacture the fasteners (i.e. hot headed with cold rolled threads, hot headed with machined threads, etc.), the heat treatments performed, and the order in which these actions were performed (i.e., fasteners manufactured and then solution annealed and age hardened, etc.). This action is required to ensure compliance with MIL-DTL-1222, paragraph 3.3.4, which requires fasteners with formed heads (i.e., hot headed, cold headed, etc.) and rolled threads to be solution annealed and age hardened after the manufacturing process. e.) Certifications for QQ-N-286 Rev G materials shall show that slow strain rate tensile SSRT test of "start material" has been accomplished per QQ-N-286 Rev G requirements. f.) Where headed fastener specifications require a yield strength test AND a wedge tensile test, a separate (new, untested) fastener is required for each of the two test methods, and both of these tests shall be reported. This does not apply to steel hex head fasteners (grades 2, 5, 8, B7, and B16) are certified to a proof load and NOT yield strength; therefore, this issue does NOT apply to those fasteners. NOTE: This does apply to All CRES and non-ferrous bolts and screws, and ALL steel socket head cap screws (grade A574 and 4340). Wedge tensile test a required test for including ones that had their yield strength and tensile strength certified by alternative testing IAW MIL-DTL-1222.ORDERING DATA/ACQUISITION REQUIREMENTS FOR MIL-E-23765/3A ELECTRODES: 1. All diameters of CuNiAI Welding, Bare, and Solid Copper Alloyed Cored Electrodes shall be ordered in accordance with reference (a) shall include the following acquisition requirements. (a) Military Specification, Electrode and Rods- Welding, Bare, Solid Copper Alloyed Cored, General Specification For; MIL-E-23765B (SH) AMENDMENT 1, 15 September 1989 (b) Electrode and Rods- Welding, Bare, Solid Copper Alloy; MIL-E-23765/3A (SH) 11 March 1986 (c) Type; CuNiAI Form 6 Size:
3/32” Diameter (d) First article inspection is not required (e) Alloy Identity testing is not required (f) N/A (g) Level C packaging is required (h) Additional special marking is not required