STUDB171B167ORDDERING_DATA.docx

DOCX document 17 KB Posted

Attached to
STUDS Federal contract opportunity
Solicitation number
SPMYM118Q0060
Issued by
Defense Logistics Agency Land and Maritime

About this file

Not Listed

View the file

Other files for this federal contract opportunity

Other files attached to STUDS, newest first.
File Type Posted
001_-_1222-1423_chem_and_mech_prop_-_Doc___8054B149.doc DOC document
006_-_1423_gaging_verification-_Doc___8054B154.doc DOC document
003_-_1423_gaging_verification-_Doc____8054B151.doc DOC document
003_-_1222-1423_chem_and_mech_prop_-_Doc____8054B151.doc DOC document
005_-_1222-1423_chem_and_mech_prop_-_Doc___8054B153.doc DOC document
005_-_1423_gaging_verification-_Doc___8054B153.doc DOC document
004_-_1423_SSRT_-_Doc___8054B152.doc DOC document
002_-_1423_gaging_verification-_Doc___8054B150.doc DOC document
006_-_1222-1423_chem_and_mech_prop_-_Doc___8054B154.doc DOC document
004_-_1222-1423_chem_and_mech_prop_-_Doc___8054B152.doc DOC document
004_-_1423_gaging_verification-_Doc___8054B152.doc DOC document
005_-_1423_SSRT_-_Doc___8054B153.doc DOC document
006_-_1423_SSRT_-_Doc___8054B154.doc DOC document
010_-_1222-1423_chem_and_mech_prop_-_Doc___8054B158.doc DOC document
015_-_1423_gaging_verification-_Doc___8054B163.doc DOC document
024_-_1423_gaging_verification-_Doc___8054B172.doc DOC document
CAP_SCREW_1B161B155_ORDERING_DATA.docx DOCX document
017_-_1222-1423_chem_and_mech_prop_-_Doc___8054B165.doc DOC document
017_-_1423_gaging_verification-_Doc___8054B165.doc DOC document
023_-_1222-1423_chem_and_mech_prop_-_Doc___8054B171.doc DOC document
025_-_1222-1423_chem_and_mech_prop_-_Doc___8054B173.doc DOC document
018_-_1222-1423_chem_and_mech_prop_-_Doc___8054B166.doc DOC document
012_-_1423_gaging_verification-_Doc___8054B160.doc DOC document
TUDB166B161_ORDERING_DATA.docx DOCX document
010_-_1222-1423_chem_and_mech_prop_-_Doc___8054B158.doc DOC document
014_-_1423_gaging_verification-_Doc___8054B162.doc DOC document
048_-_1423_gaging_verification-_Doc___8054B176.doc DOC document
025_-_1423_gaging_verification-_Doc___8054B173.doc DOC document
014_-_1222-1423_chem_and_mech_prop_-_Doc___8054B162.doc DOC document
022_-_1222-1423_chem_and_mech_prop_-_Doc___8054B170.doc DOC document
046_-_1423_SSRT_-_Doc___8054B174.doc DOC document
048_-_1222-1423_chem_and_mech_prop_-_Doc___8054B176.doc DOC document
018_-_1423_SSRT_-_Doc___8054B166.doc DOC document
023_-_1423_gaging_verification-_Doc___8054B171.doc DOC document
024_-_1222-1423_chem_and_mech_prop_-_Doc___8054B172.doc DOC document
020_-_1423_SSRT_-_Doc___8054B168.doc DOC document
019_-_1423_SSRT_-_Doc___8054B167.doc DOC document
CAP_SCREW_1B161B155_ORDERING_DATA.docx DOCX document
SPMYM1-18-Q-0060.docx DOCX document
019_-_1222-1423_chem_and_mech_prop_-_Doc___8054B167.doc DOC document
020_-_1222-1423_chem_and_mech_prop_-_Doc___8054B168.doc DOC document
019_-_1423_gaging_verification-_Doc___8054B167.doc DOC document
022_-_1423_gaging_verification-_Doc___8054B170.doc DOC document
021_-_1423_SSRT_-_Doc___8054B169.doc DOC document
021_-_1222-1423_chem_and_mech_prop_-_Doc___8054B169.doc DOC document
018_-_1423_gaging_verification-_Doc___8054B166.doc DOC document
013_-_1222-1423_chem_and_mech_prop_-_Doc___8054B161.doc DOC document
026-_1423_gaging_verification-_Doc___8054B174.doc DOC document
DOC___8054B17678054B172_ORDERING_DATA.docx DOCX document
047_-_1222-1423_chem_and_mech_prop_-_Doc__8054B175.doc DOC document
Show all 50

STUDS has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STUD, 1-1/4"-7 X 6

STUD 1-1/4"-7-UNC-3A X 6" LONG, MONEL, QQ-N-281D, MIL-S-1222J

ORDERING DATA FOR DOCUMENT# 8054B171

MIL_DTL-1222J

A: General specification for Studs, Bolts, Screws and Nuts for applications where a high degree of reliability is required;

Mil-Dtl-1222J; 08 December 2000 B: M1222ST3N20C396 NANN – 1-1/4”-7-UNC-3A x 6” long, Stud, QQ-N-281 Rev. D, Monel 400, as formed, stress relieved, uncoated.

per MIL-DTL-1222J, Type III, Style C.

C. Latest Revision D. N/A E: No Coating Required F thru J. N/A K. Locking element NOT required

L. IAW 3.13

M. All reports required.

N. N/A O. N/A P. N/A Q. IAW 4.3.2 and 4.3.2.1 R. Acceptance criteria IAW 4.3.2 and 4.3.2.1 S. Nondestructive testing and acceptance criteria shall be IAW 4.3.3 T. Mechanical Test are to be done after final heat treatment.

U. IAW 5.1

V thru BB. N/A

Lot ID marking required.

Full testing to spec and dimensional inspection reports required including Systems 22 gaging results.

REMARKS: 1. Chemical Analysis and Mechanical test reports required, see para (M)

2. Mercury Free Clause Applies.

OQE Ordering Data for CIM

Provide written verification that the chemical and mechanical properties have been determined and are acceptable IAW the required specification QQ-N281D as applicable for document # 8054B171_ are as follows:

a.) Provide written verification that the chemical analysis and mechanical properties tests have been determined and are acceptable. All test reports will contain a signed certification that the results represent the actual values for the material provided and that they are in full compliance with the contract specification. Material certification data shall be recorded on the testing company's letterhead and shall bear the name, title and signature of the authorized company representative. The name and title shall be clearly legible. Certification data supplied to the government shall be either the original mill material certification, the original copy from the testing facility, or exact photocopies of these documents. The data forwarded by the manufacturer shall contain a signed certification that the reported results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Statements on material certification documents must be positive and unqualified. The material certification data reports shall include quantitative data representing the actual values obtained during testing.
b.) Test reports will list all verified attributes and will be traceable to the material via a heat, lot, or batch number applied to the material by the manufacturer. Each piece of material must be marked with the applicable heat, lot, or batch number shown on the test reports provided. In the case of a finished product identified by a lot number manufactured from a start material identified by a heat number, the final test reports performed on the finished product samples shall be marked with the lot number. The test reports for the raw material shall be marked with the heat number of that material.
c.) Test reports labeled "Typical," those with words such as "to the best of our knowledge" or "we believe the information contained herein is true" or those that have results transcribed from other reports or documents, or test reports with the heat/lot/batch number information handwritten on them are not acceptable.
d.) Test reports for loose MIL-DTL-1222, K-Monel (QQ-N-286), fasteners and for all assemblies which contain MIL-DTL-1222 K-Monel fasteners, shall include a certification statement describing the forming process used to manufacture the fasteners (i.e. hot headed with cold rolled threads, hot headed with machined threads, etc.), the heat treatments performed, and the order in which these actions were performed (i.e., fasteners manufactured and then solution annealed and age hardened, etc.). This action is required to ensure compliance with MIL-DTL-1222, paragraph 3.3.4, which requires fasteners with formed heads (i.e., hot headed, cold headed, etc.) and rolled threads to be solution annealed and age hardened after the manufacturing process.
e) Certifications for QQ-N-286 Rev G materials shall show that slow strain rate tensile {SSRT} test of “start material” has been accomplished per QQ-N-286 Rev G requirements.
f.) Where headed fastener specifications require a yield strength test AND a wedge tensile test, a separate (new, untested) fastener is required for each of the two test methods, and both of these tests shall be reported.

Note 1: Enter specification Note 2: Enter the document number

TUD, 3/4"-10X4-1/2

STUD, 3/4"-10-UNC-3A X 4-1/2" LONG, K MONEL, QQ-N286G, MIL-S-1222J

ORDERING DATA FOR DOCUMENT# 8054B170

MIL_DTL-1222J

A: General specification for Studs, Bolts, Screws and Nuts for applications where a high degree of reliability is required;

Mil-Dtl-1222J; 08 December 2000 B: M1222ST3N12C372NCNN – ¾-10- UNC-3A x 4-1/2” long, Stud, QQ-N-286 Rev. G K500 Monel, annealed and age hardened, per MIL-DTL-1222J, ty. III, Style C.

C. Latest Revision D. N/A E: No Coating Required F thru J. N/A K. Locking element NOT required

L. IAW 3.13 (.K.)

M. All reports required.

N. N/A O. N/A P. N/A Q. Inspected IAW 4.3.2 and 4.3.2.1 R. Acceptance criteria IAW 4.3.2 and 4.3.2.1 S. Nondestructive testing and acceptance criteria shall be IAW 4.3.3 T. Mechanical Test are to be done after final heat treatment

U. IAW 5.1

V thru BB. N/A

Lot ID marking required.

Full testing to spec and dimensional inspection reports required including Systems 22 gaging results.

QQ-N-286G

A. Nickel-Copper Aluminum Alloy, Wrought (UNS N05500); QQ-N-286G, 07 December 2000 B. Form 2, Annealed and age hardened C. Latest Revision D. Forging sketch not required E. Size required to suit mfg. of fastener F. Not required G. N/A H. Tolerances are to be as specified I. Not required J. Not required K. To suit mfg. of fastener L. N/A M. Edges as specified N. To suit mfg. of fasteners O. Markings as specified P. Mechanical test required (not for re-forging) Q. N/A R. Solution annealed and SSRT IAW 4.3.6.2 S. SSRT laboratory shall be one of attached listed facilities

SUPPLY NOTE: ADDITIONAL REQUIREMENTS (1423’S ATTACHED)

1.Chemical and Mechanical certifications
2.Slow Strain Rate Testing
3.Verification of Gaging Methods

OQE Ordering Requirements for CIM Provide written verification that the chemical and mechanical properties have been determined and are acceptable IAW the required specification MIL-DTL-1222J as applicable for document # 8054B170 are as follows:

a.) Provide written verification that the chemical analysis and mechanical properties tests have been determined and are acceptable. All test reports will contain a signed certification that the results represent the actual values for the material provided and that they are in full compliance with the contract specification. Material certification data shall be recorded on the testing company's letterhead and shall bear the name, title and signature of the authorized company representative. The name and title shall be clearly legible. Certification data supplied to the government shall be either the original mill material certification, the original copy from the testing facility, or exact photocopies of these documents. The data forwarded by the manufacturer shall contain a signed certification that the reported results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Statements on material certification documents must be positive and unqualified. The material certification data reports shall include quantitative data representing the actual values obtained during testing.
b.) Test reports will list all verified attributes and will be traceable to the material via a heat, lot, or batch number applied to the material by the manufacturer. Each piece of material must be marked with the applicable heat, lot, or batch number shown on the test reports provided. In the case of a finished product identified by a lot number manufactured from a start material identified by a heat number, the final test reports performed on the finished product samples shall be marked with the lot number. The test reports for the raw material shall be marked with the heat number of that material.
c.) Test reports labeled "Typical," those with words such as "to the best of our knowledge" or "we believe the information contained herein is true" or those that have results transcribed from other reports or documents, or test reports with the heat/lot/batch number information handwritten on them are not acceptable.
d.) Test reports for loose MIL-DTL-1222, K-Monel (QQ-N-286), fasteners and for all assemblies which contain MIL-DTL-1222 K-Monel fasteners, shall include a certification statement describing the forming process used to manufacture the fasteners (i.e. hot headed with cold rolled threads, hot headed with machined threads, etc.), the heat treatments performed, and the order in which these actions were performed (i.e., fasteners manufactured and then solution annealed and age hardened, etc.). This action is required to ensure compliance with MIL-DTL-1222, paragraph 3.3.4, which requires fasteners with formed heads (i.e., hot headed, cold headed, etc.) and rolled threads to be solution annealed and age hardened after the manufacturing process.
e) Certifications for QQ-N-286 Rev G materials shall show that slow strain rate tensile {SSRT} test of “start material” has been accomplished per QQ-N-286 Rev G requirements.
f.) Where headed fastener specifications require a yield strength test AND a wedge tensile test, a separate (new, untested) fastener is required for each of the two test methods, and both of these tests shall be reported.

Note 1: Enter specification Note 2: Enter document number

TUD, 7/8"-9X5-1/2

STUD 7/8"-9X5-1/2" LONG, K MONEL, QQ-N-286G, MIL-S-1222J

ORDERING DATA FOR DOCUMENT# 8054B169

MIL_DTL-1222J

A: General specification for Studs, Bolts, Screws and Nuts for applications where a high degree of reliability is required;

Mil-Dtl-1222J; 08 December 2000 B: M1222ST3N14C388NCNN - 7/8”-9- UNC-3A x 5-1/2” long, Stud, QQ-N-286 Rev. G K500 Monel, annealed and age hardened, per MIL-DTL-1222J, ty. III, Style C.

C. Latest Revision D. N/A E: No Coating Required F thru J. N/A K. Locking element NOT required

L. IAW 3.13 (.K.)

M. All reports required.

N. N/A O. N/A P. N/A Q. Inspected IAW 4.3.2 and 4.3.2.1 R. Acceptance criteria IAW 4.3.2 and 4.3.2.1 S. Nondestructive testing and acceptance criteria shall be IAW 4.3.3 T. Mechanical Test are to be done after final heat treatment

U. IAW 5.1

V thru BB. N/A

Full testing to spec and dimensional inspection reports required including Systems 22 gaging results.

B. Form 2, Annealed and age hardened C. Latest Revision D. Forging sketch not required E. Size required to suit mfg. of fastener F. Not required G. N/A H. Tolerances are to be as specified I. Not required J. Not required K. To suit mfg. of fastener L. N/A M. Edges as specified N. To suit mfg. of fasteners O. Markings as specified P. Mechanical test required (not for re-forging) Q. N/A

1.Chemical and Mechanical certifications
2.Slow Strain Rate Testing
3.Verification of Gaging Methods

OQE Ordering Requirement for CIM

Provide written verification that the chemical and mechanical properties have been determined and are acceptable IAW the required specification MIL-DTL-1222J as applicable for document # 8054B169_ are as follows:

a.) Provide written verification that the chemical analysis and mechanical properties tests have been determined and are acceptable. All test reports will contain a signed certification that the results represent the actual values for the material provided and that they are in full compliance with the contract specification. Material certification data shall be recorded on the testing company's letterhead and shall bear the name, title and signature of the authorized company representative. The name and title shall be clearly legible. Certification data supplied to the government shall be either the original mill material certification, the original copy from the testing facility, or exact photocopies of these documents. The data forwarded by the manufacturer shall contain a signed certification that the reported results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Statements on material certification documents must be positive and unqualified. The material certification data reports shall include quantitative data representing the actual values obtained during testing.
b.) Test reports will list all verified attributes and will be traceable to the material via a heat, lot, or batch number applied to the material by the manufacturer. Each piece of material must be marked with the applicable heat, lot, or batch number shown on the test reports provided. In the case of a finished product identified by a lot number manufactured from a start material identified by a heat number, the final test reports performed on the finished product samples shall be marked with the lot number. The test reports for the raw material shall be marked with the heat number of that material.
c.) Test reports labeled "Typical," those with words such as "to the best of our knowledge" or "we believe the information contained herein is true" or those that have results transcribed from other reports or documents, or test reports with the heat/lot/batch number information handwritten on them are not acceptable.
d.) Test reports for loose MIL-DTL-1222, K-Monel (QQ-N-286), fasteners and for all assemblies which contain MIL-DTL-1222 K-Monel fasteners, shall include a certification statement describing the forming process used to manufacture the fasteners (i.e. hot headed with cold rolled threads, hot headed with machined threads, etc.), the heat treatments performed, and the order in which these actions were performed (i.e., fasteners manufactured and then solution annealed and age hardened, etc.). This action is required to ensure compliance with MIL-DTL-1222, paragraph 3.3.4, which requires fasteners with formed heads (i.e., hot headed, cold headed, etc.) and rolled threads to be solution annealed and age hardened after the manufacturing process.
e) Certifications for QQ-N-286 Rev G materials shall show that slow strain rate tensile {SSRT} test of “start material” has been accomplished per QQ-N-286 Rev G requirements.
f.) Where headed fastener specifications require a yield strength test AND a wedge tensile test, a separate (new, untested) fastener is required for each of the two test methods, and both of these tests shall be reported.

Note 1: Enter specification Note 2: Enter The document number

STUD, 7/8"-9X6" LG

STUD, 7/8"-9-UNC-3A X 6" LONG, K MONEL, QQ-N286G, MIL-S-1222J

ORDERING DATA FOR DOCUMENT# 8054B168

MIL_DTL-1222J

A: General specification for Studs, Bolts, Screws and Nuts for applications where a high degree of reliability is required;

Mil-Dtl-1222J; 08 December 2000 B: M1222ST3N14C396NCNN - 7/8”-9- UNC-3A x 6” long, Stud, QQ-N-286 Rev. G K500 Monel, annealed and age hardened, per MIL-DTL-1222J, ty. III, Style C.

C. Latest Revision D. N/A E: No Coating Required F thru J. N/A K. Locking element NOT required

L. IAW 3.13 (.K.)

M. All reports required.

N. N/A O. N/A P. N/A Q. Inspected IAW 4.3.2 and 4.3.2.1 R. Acceptance criteria IAW 4.3.2 and 4.3.2.1 S. Nondestructive testing and acceptance criteria shall be IAW 4.3.3 T. Mechanical Test are to be done after final heat treatment

U. IAW 5.1

V thru BB. N/A

Full testing to spec and dimensional inspection reports required including Systems 22 gaging results.

B. Form 2, Annealed and age hardened C. Latest Revision D. Forging sketch not required E. Size required to suit mfg. of fastener F. Not required G. N/A H. Tolerances are to be as specified I. Not required J. Not required K. To suit mfg. of fastener L. N/A M. Edges as specified N. To suit mfg. of fasteners O. Markings as specified P. Mechanical test required (not for re-forging) Q. N/A

1.Chemical and Mechanical certifications
2.Slow Strain Rate Testing
3.Verification of Gaging Methods

Provide written verification that the chemical and mechanical properties have been determined and are acceptable IAW the required specification MIL-DTL-1222J as applicable for document # 8054B168 are as follows:

a.) Provide written verification that the chemical analysis and mechanical properties tests have been determined and are acceptable. All test reports will contain a signed certification that the results represent the actual values for the material provided and that they are in full compliance with the contract specification. Material certification data shall be recorded on the testing company's letterhead and shall bear the name, title and signature of the authorized company representative. The name and title shall be clearly legible. Certification data supplied to the government shall be either the original mill material certification, the original copy from the testing facility, or exact photocopies of these documents. The data forwarded by the manufacturer shall contain a signed certification that the reported results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Statements on material certification documents must be positive and unqualified. The material certification data reports shall include quantitative data representing the actual values obtained during testing.
b.) Test reports will list all verified attributes and will be traceable to the material via a heat, lot, or batch number applied to the material by the manufacturer. Each piece of material must be marked with the applicable heat, lot, or batch number shown on the test reports provided. In the case of a finished product identified by a lot number manufactured from a start material identified by a heat number, the final test reports performed on the finished product samples shall be marked with the lot number. The test reports for the raw material shall be marked with the heat number of that material.
c.) Test reports labeled "Typical," those with words such as "to the best of our knowledge" or "we believe the information contained herein is true" or those that have results transcribed from other reports or documents, or test reports with the heat/lot/batch number information handwritten on them are not acceptable.
d.) Test reports for loose MIL-DTL-1222, K-Monel (QQ-N-286), fasteners and for all assemblies which contain MIL-DTL-1222 K-Monel fasteners, shall include a certification statement describing the forming process used to manufacture the fasteners (i.e. hot headed with cold rolled threads, hot headed with machined threads, etc.), the heat treatments performed, and the order in which these actions were performed (i.e., fasteners manufactured and then solution annealed and age hardened, etc.). This action is required to ensure compliance with MIL-DTL-1222, paragraph 3.3.4, which requires fasteners with formed heads (i.e., hot headed, cold headed, etc.) and rolled threads to be solution annealed and age hardened after the manufacturing process.
e) Certifications for QQ-N-286 Rev G materials shall show that slow strain rate tensile {SSRT} test of “start material” has been accomplished per QQ-N-286 Rev G requirements.
f.) Where headed fastener specifications require a yield strength test AND a wedge tensile test, a separate (new, untested) fastener is required for each of the two test methods, and both of these tests shall be reported.

Note 1: Enter specification Note 2: Enter documentation

STUD, 7/8" 9 X 3.4375

STUD, 7/8"-9 UNC-3A X 3- 7/16" LONG, K MONEL, QQ-N-286G, MIL-S-1222J

ORDERING DATA FOR DOCUMENT# 8054B167

MIL_DTL-1222J

A: General specification for Studs, Bolts, Screws and Nuts for applications where a high degree of reliability is required;

Mil-Dtl-1222J; 08 December 2000 B: M1222ST3N14C355NCNN - 7/8”-9- UNC-3A x 3-7/16” long, Stud, QQ-N-286 Rev. G K500 Monel, annealed and age hardened, per MIL-DTL-1222J, ty. III, Style C.

C. Latest Revision D. N/A E: No Coating Required F thru J. N/A K. Locking element NOT required

L. IAW 3.13 (.K.)

M. All reports required.

N. N/A O. N/A P. N/A Q. Inspected IAW 4.3.2 and 4.3.2.1 R. Acceptance criteria IAW 4.3.2 and 4.3.2.1 S. Nondestructive testing and acceptance criteria shall be IAW 4.3.3 T. Mechanical Test are to be done after final heat treatment

U. IAW 5.1

V thru BB. N/A

Full testing to spec and dimensional inspection reports required including Systems 22 gaging results.

B. Form 2, Annealed and age hardened C. Latest Revision D. Forging sketch not required E. Size required to suit mfg. of fastener F. Not required G. N/A H. Tolerances are to be as specified I. Not required J. Not required K. To suit mfg. of fastener L. N/A M. Edges as specified N. To suit mfg. of fasteners O. Markings as specified P. Mechanical test required (not for re-forging) Q. N/A

1.Chemical and Mechanical certifications
2.Slow Strain Rate Testing
3.Verification of Gaging Methods

OQE Ordering Requirements for CIM Provide written verification that the chemical and mechanical properties have been determined and are acceptable IAW the required specification MIL-DTL-1222J as applicable for document # 8054B167_ are as follows:

a.) Provide written verification that the chemical analysis and mechanical properties tests have been determined and are acceptable. All test reports will contain a signed certification that the results represent the actual values for the material provided and that they are in full compliance with the contract specification. Material certification data shall be recorded on the testing company's letterhead and shall bear the name, title and signature of the authorized company representative. The name and title shall be clearly legible. Certification data supplied to the government shall be either the original mill material certification, the original copy from the testing facility, or exact photocopies of these documents. The data forwarded by the manufacturer shall contain a signed certification that the reported results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Statements on material certification documents must be positive and unqualified. The material certification data reports shall include quantitative data representing the actual values obtained during testing.
b.) Test reports will list all verified attributes and will be traceable to the material via a heat, lot, or batch number applied to the material by the manufacturer. Each piece of material must be marked with the applicable heat, lot, or batch number shown on the test reports provided. In the case of a finished product identified by a lot number manufactured from a start material identified by a heat number, the final test reports performed on the finished product samples shall be marked with the lot number. The test reports for the raw material shall be marked with the heat number of that material.
c.) Test reports labeled "Typical," those with words such as "to the best of our knowledge" or "we believe the information contained herein is true" or those that have results transcribed from other reports or documents, or test reports with the heat/lot/batch number information handwritten on them are not acceptable.
d.) Test reports for loose MIL-DTL-1222, K-Monel (QQ-N-286), fasteners and for all assemblies which contain MIL-DTL-1222 K-Monel fasteners, shall include a certification statement describing the forming process used to manufacture the fasteners (i.e. hot headed with cold rolled threads, hot headed with machined threads, etc.), the heat treatments performed, and the order in which these actions were performed (i.e., fasteners manufactured and then solution annealed and age hardened, etc.). This action is required to ensure compliance with MIL-DTL-1222, paragraph 3.3.4, which requires fasteners with formed heads (i.e., hot headed, cold headed, etc.) and rolled threads to be solution annealed and age hardened after the manufacturing process.
e) Certifications for QQ-N-286 Rev G materials shall show that slow strain rate tensile {SSRT} test of “start material” has been accomplished per QQ-N-286 Rev G requirements.
f.) Where headed fastener specifications require a yield strength test AND a wedge tensile test, a separate (new, untested) fastener is required for each of the two test methods, and both of these tests shall be reported.