This document is a Request for Quote (RFQ) for the procurement of an Electrical Test Bench by the Defense Logistics Agency (DLA) Land and Maritime for the Puget Sound Naval Shipyard in Bremerton, Washington.
The Electrical Test Bench must meet detailed specifications, including a hardwood countertop, heavy-duty aluminum framing, and a variety of electrical components and test equipment such as power supplies, multimeters, oscilloscopes, and power quality analyzers. All instruments must be calibrated and comply with industry standards. The Test Bench must fit within specific dimensional and weight requirements.
The RFQ is being issued on an unrestricted basis using commercial item procedures. It will be awarded as a firm-fixed-price commercial purchase order to the vendor submitting the lowest priced, technically acceptable offer. Quotes must be emailed to the buyer by 10 AM Pacific Time on July 08, 2024. The FOB destination is Bremerton, WA.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| DRAWING.pdf | ||
| SOLICITATION SPMYM2-24-Q-1862.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Electrical Test Bench Specification Sheet
Tabletop Setup:
Table Top: Hardwood countertop with neoprene black rubber. 1-1/2” thick minimum to 3-1/4” thick maximum, 3’ minimum depth, minimum length of 8’ to maximum of 10’.
Tabletop to be mounted on 2 each cabinets 24” minimum, with lockable swivel wheels rated properly for capacity. Each cabinet is to have a minimum of 5 drawers. Cabinets are to be spaced to allow a work chair in between.
Construction: Console, heavy duty aluminum framing and high impact Kydex panels or equivalent. Front Panel, durable PVC and high impact Formica laminate or equivalent.
Electrical Requirements:
Main Input Power of 480 VAC, 3P, 60Hz Secondary Input Power of 240 VAC, Single Phase, L-L, 60Hz Disconnect Switch, 600VAC max 3 pole 100A minimum enclosed disconnect switch.
Load Center, 240 VAC max 1P, 60 Hz, 100A minimum, NEMA Type 1 enclosed load center.
3P Motor Starter with motor controller that is panel mounted, minimum size 3, 65A max, emergency stop button, and remote start.
Power Strip, minimum of six 20A 120VAC receptacles.
Continuity Test Panel with banana jacks, fuse, red lamp, on/off switch, and audible alert to conduction.
24 VDC Fixed Supply with banana jacks and fuse with continuous 24 VDC minimum supply.
Must Include the Following Panel Mounted Meters and Calibrators:
Variable DC Power Supply, minimum 30VDC/5A single variable output.
5.5 Digit Multimeter, measure up to 750VAC and 1,000VDC, with resistance, amperage, frequency, period and continuity, and diode test.
AC/DC Power Supply with variable AC/DC output in at least the following ranges: 0-140VAC @
16A, 0-280VAC @ 10A, 0-560VAC @ 5A, 0-120VDC @ 16A, 0-240VDC @ 8A, 0-480VDC @ 4A.
5000V minimum Megohmmeter, automated 250V, 500V, 1000V, 2500V and 5000V insulation tester. Test leads.
10A minimum Micro-Ohmmeter, measures from 250 mΩ to 2500.0Ω. Test current selections of
0.1mA, 1mA, 10mA, 100mA, 1A and 10A. Test leads.
Digital Panel Analyzer that displays current, voltage, amps, and watts.
Function Generator, 10 MHz minimum sine and square waveforms, pulse, ramp, triangle, noise, and DC waveforms, AM, FM, and PWM modulation types, linear and logarithmic sweeps and burst operation, 10 mVpp to 10Vpp amplitude range.
Digital Oscilloscope, minimum 100MHz bandwidth, 500MHz passive probe (10:1 attenuation).
Digital Relay Timer, 40.00Hz to 500.0Hz measurement range or greater, 5 to 250 or greater DC or AC input. Include test leads and alligator clips.
Current Power Supply, peak output of 1000A with multiple current ranges. Include contact leads and high cam-lok connectors.
Power Quality Analyzer with motor testing/diagnosis. Minimum of 8 independent channels.
Include software for analysis. 4 GB internal Data storage. Measurement ranges: 1000V rms 3A to 3000A, AC/DC. Include AC adapter, 8-6 FT cables with alligator clips, 1 set of 3-phase flex probes and 1 single phase flex probe, Dran-View 7 Enterprise software, soft case.
Calibration and Certificates:
All instruments calibrated traceable to NIST. Accredited by A2LA, meters must comply with ISO 17025 standards. Certifications good for one year.
All components must meets industry standards for compliance.
Accessories:
Test Lead Kit that includes T/C wire kits, minimum 2 ea. of J, K, T, and E with minimum 5’ of wire.
Motor Starter Test leads, minimum 15’ with cam-lok plugs on one end and insulated 100A minimum alligator clams on the other end.
Soldering/ Desoldering Station: 200W minimum, 200° F or below to 850° F or above, digital station with micro tweezers and safety stands.
Hot Air Station: 900W minimum 150° F or below to 1100° F or above digital station, 5-100 LPM air flow.
Anti-Static Table Mat, 24” x 48” or larger heavy duty anti-static table mat, minimum 3 layers of vinyl. Include snap fasteners, wrist grounding system, minimum 15’ grounding cord and 2 or more 6’ minimum wrist straps.
Anti-Static Floor Mat: 48” x 72” or larger heavy duty anti-static floor mat. Include 10’ minimum grounding cord.
Overhead Lamp Cooling Fan
Test Bench Must Be Within The Following Dimensions and Weight:
Height minimum of 80” to a maximum of 90” Width minimum of 96” to a maximum of 120” Depth minimum of 36” to a maximum of 38” No greater than 1200 LBS
Manuals:
Instruction manuals for all components included in the Electrical Test Bench Assembly.