Specifications-Pumps-Central Crops.docx
DOCX document 170 KB Posted
- Attached to
- Custom Built Irrigation Pumps Federal contract opportunity
- Solicitation number
- 12405B23Q0517
About this file
This document outlines specifications for furnishing and delivering four custom built irrigation pump units to the Central Crops Research Station in Clayton, North Carolina by July 26, 2023. The pumps must meet minimum specifications including 100HP totally enclosed fan cooled motors, Cornell 3YH pumps with float assemblies, strainers, discharge fittings and adjustable pump depths. Controller requirements include 100HP 480V 3-Phase variable frequency drives with lightning protection, bypass starters and surge traps. Pump unit manufacturers must be able to respond to service requests within 24 hours and maintain factory authorized technicians within 150 miles of the research station. This opportunity relates to federal contract solicitation 12405B23Q0517 for custom built irrigation pumps issued by the US Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications
Furnish and Deliver Irrigation Pump Units
Central Crops Research Station Clayton, North Carolina
Prepared by: Kurt Geisler 07/26/2023
1. Description of Need:
· Furnish and deliver four (4) complete pump units as specified in this document.
· Pump units must meet the minimum specifications.
· Delivery site: 13223 US Business 70 West, Clayton, NC, 27520
2. Pump Unit Minimum Specifications:
Motor:
· 100HP, 3600RPM, totally enclosed, fan cooled motor Pump:
· Cornell 3YH pump
· Equipped with float assembly, strainer, and discharge fittings.
Float assembly:
· Capable of supporting complete pump unit and discharge piping.
· Adjustable pump depth/height.
· Equipped with air bleed bypass anti-airlock lines.
Controller/Electrical:
· Variable Frequency Drive 100HP, 480V, 3-Phase control panel.
· Equipped with lightning protection, bypass starter, and surge trap (BRKR MOD-4) Manufacturer:
· Pump unit manufacturer must maintain factory authorized technicians within a 150 mile radius of the Central Crops Research Station and have the ability to respond with on-site service within 24 hours of request for service.
image1.png