Specifications for Greenhouse LED fixtures
The following specifications are met by Valoya BX180C2+MW500MA, AP67
1. Size—long and narrow is a requirement that best distributes light uniformly over our bench configuration while minimizing shading of natural light and maximizing ease of installation. Light fixtures must be: 68—72” in length x ≤2.9” wide x ≤ 2.3” high
2. Weight—to minimize structural requirements for installation, minimizing weight is desirable. Fixtures should weigh no more than 12 pounds (includes light and driver units whether separate or integrated).
3. construction—aluminum body, dust- and water-tight
4. cooling—passive, via passive transfer from body of fixture to the air without forced ventilation by fans
5. light spectrum <400 nm 0%; 400—500 nm 14%; 500—600 nm 16%; 600—700 nm 53%; 700—800 nm 17%. CRI = 70.
6. light output intensity: 2.06 μmol/W at full power; dimmable.
7. voltage: 100-240, 277 VAC
8. Power consumption: 199W or less; includes power consumption of driver.
9. installation—fixtures should have a hook, eye, or bracket to permit hanging on chains. Drivers to be supplied with pigtail suitable for attachment of plug end.
10. Must be RoHS compliant and meet the following North American standards:
UL1598: Luminare safety; UL8750: Light Emitting Diode (LED) equipment for use In lighting products; UL2108: Standard for Low Voltage Lighting Systems; CSA C22.2: #9.0: General Requirements for Luminaires; CSA C22.2: #250.0.8: Safety for Light emitting diode (LED) equipment for lighting applications; CSA C22.2 No. 250.13-14: Light Emitting Diode (LED) equipment for use in lighting products.
11. warranty: Five years free of defects in materials and workmanship that cause failure. >5% of LEDs failing to illuminate is considered a failure. Failed components to be replaced by manufacturer during warranty period.