1. 2000W microwave power in unpulsed mode.

1. Temperature sensor – Contact-free temperature measurement of all kinds of vessels.

1. Cooling unit – Fast vessel cooling for high throughput.

1. SmartScreen – Intuitive software with installed methods, video manuals, etc.

1. Remote control for easy connection with your mobile phone or notebook.

1. Time saving visual interaction including high safety standards; such as fluorpolymer coated cavity, and resealing safety.

1. Instrumentation uses silicon carbide plates that bears several advantages for microwave chemistry.

1. Silicon carbide plates insure heating efficiency with microwave irradiation that distributes heat quickly.

1. Even heating permits different reaction mixtures (solvent, substrates, catalysts, various molar ratios) within the same run while maintaining homogeneity across the silicon carbide plate.

1. Silica carbide and robust housing are proven very safe, including digestion venting and exhaust that runs to a fume hood.

1. A dedicated 3-meter vent tube is included, which can be ordered longer from the factory based upon user installation needs.

1. Reaction volumes can be as small as 100-µL and can reach up to 3-ml at a maximum temperature/pressure limit of 200 °C, at elevated pressures (20 bar).

1. The chosen rotor and plates can process up to 96 samples per run.

1. Complete digestion and extraction of organic and inorganic samples under high pressure and temperatures, as well as for synthesis.

1. A scientifically proven and efficient amino acid and protein digestion workhorse.

1. Overall, the instrument facilitates the most robust, high throughput, fastest and safest method and efficiency for a complicated amino acid digestion procedure with concentrated hydrochloric acid

1. This instrument accomplishes multiple acid digestions in minutes, as opposed to most acidic methods that run overnight.

1. A dedicated 220V power supply is needed.

1. Necessary vials and vial caps required, as well as on-site training is included.

1. Some of the specifications in the second paragraph are good to include like up to how many samples you’d need to run, volumes,