This document outlines specifications for 2.4mm RF power sensor standards required by the Communications Technology Laboratory Radio Frequency Technology Division Guided Wave Electromagnetics Group at the National Institute of Standards and Technology. It requests four RF power sensor standards with specified frequency ranges, reflection coefficients, input power limits, and leakage levels. It also requires one each of a short-circuit, open-circuit, and mismatch microcalorimeter characterization standard with identical specifications except for the element dissipating RF power. Delivery is required by a specified date to NIST in Boulder, Colorado. Training, warranty, calibration, and maintenance services are also specified over option periods up to four years. The related federal contract opportunity is a solicitation from the Department of Commerce NIST for the required 2.4mm RF power sensor standards.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment B QAs-1.xls | XLS spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Requirements / Specification Document
TITLE: 2.4 mm RF Power Sensor Standards
Requesting Laboratory / Division / Group:
Communications Technology Laboratory Radio Frequency Technology Division Guided Wave Electromagnetics Group (672.01)
General Statement of Need:
These are 2.4 mm thermoelectric power sensor standards that are compatible with microcalorimeters. This procurement also includes special standards that are intended to help characterize the microcalorimeter. These items are being acquired as part of an agreement with the Army Primary Standards Laboratory.
Item Specifications and Quantities:
Item 1: RF Power Sensor Standards (Rohde & Schwarz Model NTS50T) Quantity: 4 EACH Specifications: 1.1 Possess a 2.4 mm coaxial connector.
1.2 A radiofrequency (RF) termination with an operating
frequency ranges from DC to 50 GHz.
1.3 RF termination shall have a reflection coefficient magnitude of less than 0.2 across the operating frequency range when referenced to a 50 Ω impedance.
1.4 RF termination shall have a maximum input power of at
least 20 dBm.
1.5 RF leakage from the transfer standard shall be at least 40 dBc below the RF input power across the operating frequency range.
1.6 A DC heater with a maximum input power of at least 20
dBm.
1.7 DC heater shall have a four-wire lead configuration
1.8 DC heater shall have a DC resistance in the range of 50 Ω to
2 kΩ.
1.9 A thermopile to sense heating from RF power dissipation
with a sensitivity of at least 100 mV/W and a thermopile to sense heating from DC power dissipation with a sensitivity of at least 100 mV/W. Heating from both RF and DC power may be sensed with a single thermopile or with one thermopile for the RF termination and one for the DC heater.
1.10 A DC connector that allows direct electrical connections to the DC heater, the thermopile(s), and any auxiliary temperature sensors
1.11 If the transfer standard contains active readout or data storage electronics, it shall be possible to operate the transfer standard without supplying power to these electronics. The RF termination, DC heater, thermopile(s), and any auxiliary temperature sensors shall be operable without supplying power to active readout or data storage electronics.
1.12 Dimensions of less than 100 mm × 50 mm × 50 mm (length × width × height).
1.13 Total mass of less than 100 g.
Item 2: Short-circuit Microcalorimeter Characterization Standard Quantity: 1 EACH Specifications: 2.1 Possess the same design as the RF power sensor standard, with the exception that the element that dissipates RF power is replaced with a short-circuit termination designed to reflect RF power.
Item 3: Open-circuit Microcalorimeter Characterization Standard (Rohde &
Schwarz) Quantity: 1 EACH Specifications: 3.1 Possess the same design as the RF power sensor standard, with the exception that the element that dissipates RF power is replaced with an open-circuit termination designed to reflect RF power.
Item 4: Mismatch Microcalorimeter Characterization Standard (Rohde &
Schwarz) Quantity: 1 Specifications: 4.1 Possess the same design as the RF power sensor standard, with the exception that the element that dissipates RF power is replaced with a termination designed to partially reflect RF power, and partially dissipate RF power.
Procurement Support Information and Ancillary Services:
Section Requirements/Specifications
Planning Considerations ☐ N/A
☐ List any visits required to allow potential vendors to see site specific constraints.
[Explain Requirements.] ☐ US citizen required on-site (foreign nationals require pre-registration 30 days prior to visit.)
☐ Vendor Representative On-Site more than three (3) days.
☐ Other Considerations:
[List other considerations to ensure an accurate quote.]
Shipping & Delivery ☐ N/A
Shipping Address:
☒ NIST-Boulder
Mail Stop: 672.01 325 Broadway Boulder, CO 80305
Shipping Criteria:
☐ Partial Delivery Acceptable
☐ [Enter Shipping and Delivery information by item.] ☐ Direct Delivery to OU Building Required [Explain Need for Requirement]
Building /Room Number: [Enter Building/Room Number] ☐ Building has Loading Dock
Containerization Preference: [Enter Container Type] Other Requirements:
[List Any Other Requirement] Delivery Date Criteria:
☐ Delivery Shall Be Competed No Later Than:
Click or tap to enter a date.
☐ Delivery Shall Be Made No Earlier Than:
Click or tap to enter a date.
☐ Scheduled Deliveries:
Item Number Due Date
☐ Other:
[List Other Shipping, Delivery or Special Requirements.]
Electronic Media ☒ N/A
[Enter Electronic Media Requirements by Item.]
☐ Software ☐ Electronic Manuals ☐ License Key ☐ Other:
[List Any Other Electronic Media Requirements] ☐ US Government Email Address for Software Delivery:
[Enter Address]
Installation
[Enter Installation Requirements by Item]
☐ Vendor Technician on Site ☐ Rigging ☐ Uncrating / Unpackaging ☐ Removal of Packaging Material ☐ Equipment Set Up ☐ Start-Up Services ☐ Turnkey Installation ☐ Other:
[Enter Details] NOTE: SME shall be the coordination POC.
Facility / Utility Considerations ☒ N/A
[List Site Specific Utility Considerations by Item] ☐ OFPM Work Order Numbers
[List Work Order Numbers]
☐ Power Available
Voltage: [Enter voltage] (V) Maximum Current: [Enter max current draw] (A) Phase: [Choose Phase]
Frequency: [Typically 60Hz] (Hz) NEMA Plug Type: [Enter Plug Type] (i.e.: NEMA L5-20P) Environment: [Choose Environment] Other Power Considerations:
[List Any Other Power Considerations.]
☐ Utility Connections:
[List Relevant Available Utilities, Pressure(s) and Flowrate(s).]
☐ Other Considerations:
[List Other Considerations to Ensure an Accurate Quote.]
Inspection and Acceptance ☐ N/A
[Inspection Requirements Per Item (Who, When, What, Where)] ☐ On-Site
☒ Acceptance is NOT Expected to Exceed 7 Business Days
☐ Acceptance Expected to Exceed 7 Business Days:
[Duration]
☐ Inspection and Acceptance Plan:
[Explanation]
[Enter Other Requirements]
Training
Training Requirements (Who, When, What, Where)
☐ Number of Trainees: [Enter Number of Trainees] ☐ On-Site
☐ Off-Site Location: [Enter Location(s)] Is Trainee Travel Required: [Choose Answer] Scope of Training ☐ Operation ☐ Maintenance ☐ Troubleshooting
☐ Safety ☐ Other [Enter Other Scope of Training Requirements] ☐ Training Materials to be Provided by Government:
[Describe Materials] ☐ Training Materials to be Provided by Vendor:
[Describe Materials] ☐ Other [Enter Other Training Requirements] NOTE: TPOC shall be coordination POC.
Warranty ☐ N/A
Base Manufacturer Warranty is acceptable Warranty Length: [i.e. 3 - Years] What is included?
☐ Labor ☐ Parts ☐ Travel ☐ Cost and Liability for Returns
☐ Other [Enter Other Requirements]
☐ 1 Option Period ☐ 2 Option Periods ☐ 3 Option Periods ☐ 4 Option Periods (Maximum)
Calibration
[Describe Calibration Requirements Per Item] Calibration Plan Length: [i.e. 3 - Years] What is Included?
☐ Labor ☐ Spare Parts ☐ Consumables
☐ Travel ☐ Cost and Liability for Shipment ☐ Software Updates ☐ Manuals
☐ Other [Enter Other Requirements] ☐ Requirements:
[Enter Requirements] (i.e.: On-Site Within 72 hours, etc.)
☐ 1 Option Period
Length: [i.e. 1 – Year / 6 - Months] ☐ 2 Option Periods
Maintenance
[Describe Maintenance Requirements Per Item] Maintenance Plan Length: [i.e. 3 - Years] What is Included?
☐ Labor ☐ Spare Parts ☐ Consumables
☐ Travel ☐ Cost and Liability for Shipment ☐ Software Updates ☐ Manuals
☐ Other
☐ Requirements:
[Enter Requirements] (i.e.: On-Site Within 72 hours, etc.)
☐ 1 Option Period
Length: [i.e. 1 – Year / 6 - Months] ☐ 2 Option Periods
Government Furnished Material / Equipment ☒ N/A
List Any Government Furnished Material / Equipment Per Item] ☐ Samples for Testing
☐ Equipment which will leave Government Site
Description:
Serial Number:
NIST Property Number:
[Enter Description] [Enter Serial Number] [Enter NIST Property Number]
☐ Other: [Enter Other Details]
Travel
[Describe any Travel Requirements Per Item] ☐ Explain:
[Enter Justification / Requirement]
File details come from the government source that posted it. Updated .