CLIN 0004 AK14068169.pdf

PDF 130 KB Posted

Attached to
DDAA Multiple SPI (Special Packaging Instruction) Boxes Federal contract opportunity
Solicitation number
SP3300-25-Q-0018
Issued by
Defense Logistics Agency Distribution

About this file

This document is a Special Packaging Instruction (SPI) for a federal contract opportunity. It provides detailed packaging requirements for a vaneaxial fan, including cleaning, drying, preservation, packing, marking, and inspection instructions. The key details are:

The federal contract opportunity is for multiple SPI boxes for DLA Distribution Anniston, AL (DDAA). It is a Firm-Fixed Price (FFP) contract solicited as a 100% Small Business Set-Aside under NAICS 321920 (Wood Container and Pallet Manufacturing). The Product Service Code is 8115 (Boxes, Cartons, and Crates). The packaging specifications reference various military and commercial standards such as MIL-STD-2073-1D, ASTM-D4727, ASTM-D5118, and MIL-DTL-117. The packaging includes a multi-layer approach using caps, wraps, liners, sleeves, containers, bags, and cushions. Inspection of the preservation, unit pack, and packing is required per the applicable standards.

View the file

Other files for this federal contract opportunity

Other files attached to DDAA Multiple SPI (Special Packaging Instruction) Boxes, newest first.
File Type Posted
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
CLIN 0005 AK14068167.pdf PDF
Amendment 0001.pdf PDF
CLIN 0003 10730076.pdf PDF
CLIN 0002 AK12922993 packaging.pdf PDF
CLIN 0001 AK13458888.pdf PDF
CSS SP3300-25-Q-0018.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DD FORM 2169, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 4 Pages

SPECIAL PACKAGING INSTRUCTION Form Approved OMB No. 0704-0188

-CC/TB

The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS

1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.

12388111 (19207) FAN, VANEAXIAL 19207 AK14068169

4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION

4140-01-406-8169 05-20-2002 A

7. QUP 8. ICQ 9. UNIT PACK WT. (LB) 10. UNIT PACK CU (CU FT) 11. UNIT PACK SIZE (INCHES)

1 EA NONE 97.7 5.777 22.6 X 20.6 x 21.9

12. MILITARY PRESERVATION (METHOD) 18.

STEPS

19.

REQ’D

20.

DESCRIPTION

MIL-STD-2073-1D, METHOD 42 SEE NOTES

13. CLEANING

MIL-STD-2073-1D, CODE 1

14. DRYING

MIL-STD-2073-1D

15. PACKING

a. LEVEL A

MIL-STD-2073-1D AND NOTE I

b. LEVEL B

MIL-STD-2073-1D AND NOTE I

16. MARKING

MIL-STD-129

17. NOTES / DRAWING

A. REFER TO THE BILL OF MATERIALS FOR CIRCLED NUMBERS AND REFERENCED ITEM NUMBERS ON THE

ACCOMPANYING PAGES.

B. PLACE CAP, ITEM 1, ON SHAFT OF GEARBOX, SEE FIGURE 4 FOR LOCATION ON PART.

C. WRAP PART WITH WRAP, ITEM 2, AND SECURE WITH TAPE.

D. PLACE LINER, ITEM 3, IN CONTAINER, ITEM 5, THEN PLACE WRAPPED PART INTO CONTAINER.

E. PLACE SLEEVE, ITEM 4, OVER GEARBOX, AS SHOWN IN FIGURE 4. CLOSE CONTAINER IN ACCORDANCE

WITH ASTM-D1974, METHOD 2B6.

F. PLACE CONTAINER, ITEM 5, INTO BAG, ITEM 6.

G. PLACE ONE CUSHION, ITEM 7, ON EACH CORNER OF BAGGED CONTAINER.

H. PLACE PREPARED CONTAINER FROM NOTE G INTO CONTAINER, ITEM 8. CLOSE CONTAINER IN

ACCORDANCE WITH ASTM-D1974, METHOD 2B3.

I. LEVEL A: PACKING SHALL BE ACCOMPLISHED USING A CLEATED PLYWOOD BOX, TYPE B, CONFORMING

TO ASTM-D6251, TYPE III, CLASS 1.

LEVEL B: THE UNIT CONTAINER IS AN ACCEPTABLE LEVEL B SHIPPING CONTAINER WHEN SEALED AND

REINFORCED IN ACCORDANCE WITH ASTM-D1974, METHOD 2C OR 2D.

FOR BOTH LEVEL A AND LEVEL B, WHEN THE TOTAL QUANTITY TO BE SHIPPED TO THE SAME

DESTINATION EXCEEDS 125 POUNDS, EXTERIOR PACKS WITHOUT SKIDS SHALL BE PALLETIZED.

MIL-HDBK-774 MAY BE USED FOR GUIDANCE.

J. INSPECT THE PRESERVATION, THE UNIT PACK AND THE PACKING IN ACCORDANCE WITH

MIL-STD-2073-1D AND THE APPLICABLE CONTAINER SPECIFICATION.

DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 2 of 4 Pages

OMB No. 0704-0188

-CC

The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS

1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.

12388111 (19207) FAN, VANEAXIAL 19207 AK14068169

4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION

4140-01-406-8169 05-20-2002 A

SCORES

FIGURE 1

17-5/8

SLEEVE, ITEM 4

FIGURE 2

SCORES

FLUTES

18-9/16

LINER, ITEM 3

17-3/4

34-5/16

FLUTES

68-5/8

71-7/8

54-9/16

35-15/16

DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 3 of 4 Pages

OMB No. 0704-0188

-CC

The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS

1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.

12388111 (19207) FAN, VANEAXIAL 19207 AK14068169

12388111

PACKAGING CONFIGURATION

CUSHION, ITEM 7

FIGURE 3

FIGURE 4

DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 4 of 4 Pages

OMB No. 0704-0188

-CC

The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS

1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.

12388111 (19207) FAN, VANEAXIAL 19207 AK14068169

BILL OF MATERIALS

DESCRIPTION

SIZE

SPECIFICATION DATA

QTY.

1 CAP NAS844. 1

2 WRAP 69 X 36 A-A-3174, POLYETHYLENE,

THICKNESS 4 MIL.

3 LINER SEE FIGURE 1 ASTM-D4727, TYPE CF, CLASS D,

VARIETY DW, GRADE 500.

4 SLEEVE SEE FIGURE 2 ASTM-D4727, TYPE CF, CLASS D,

VARIETY TW, GRADE 1100.

5 CONTAINER 18-7/8 X 17-5/8 X 18 ASTM-D5118, TYPE CF, CLASS D,

STYLE FOL, VARIETY SW, GRADE 350.

6 BAG 42 X 44 MIL-DTL-117, TYPE I, CLASS E, STYLE

1.

7 CUSHION SEE FIGURE 3 A-A-59136, CLASS 1, GRADE A, TYPE

I.

8 CONTAINER 21-1/2 X 20-1/4 X

21-3/8

ASTM-D5118, TYPE CF, CLASS WR,

STYLE RSC, VARIETY SW, GRADE V3c.

File details come from the government source that posted it. Updated .