Statement of Work Mindrum Precision, Inc.

Background The United States National Aeronautics and Space Administration (NASA) plans to launch a mission to Titan, the largest moon of Saturn, in order to study prebiotic chemistry and extraterrestrial habitability at various surface locations with the use of a mobile robotic rotorcraft lander that will include the Dragonfly Mass Spectrometer (DraMS). In order for DraMS to accomplish its objectives a precision ion trap mass spectrometer (ITMS) assembly comprised of four hyperbolic rods and a pair of end ceramics are required to be machined to some of the highest levels of precision available in the industry.

Scope

- Fabricate ITMS rod assembly parts per released fabrication drawings. Provide material certs and full inspection documentation from Zeiss Contura CMM (or equivalent):

o PN # 2314451- ,Analyzer Rod, Slitted Qty: 10 Material: TI-6AL-4V Annealed o PN # 2314452- ,Analyzer Rod, Solid Qty: 10 Material: TI-6AL-4V Annealed o PN # 2314453- ,End Ceramic, Analyzer Rod Qty: 10 Material: >99% Alumina (Al2O3)

Requirements

Conformance to the requirements as specified in the mechanical design drawings for the respective parts.

Material certificates to be supplied with the delivered parts.

Full inspection report from Zeiss Contura CMM or equivalent to be provided on delivered parts meeting dimensional requirements specified in the drawing.

Qty 2 of each will be needed before the remaining Qty 8, allowing for a possibility of a partial shipment to meet the need date specified below.

Deliverables or Delivery Schedule Period of performance: February 1st, 2021 to July 1st, 2020

A minimum Qty of 2 of each + accompanying inspection reports + material certificates shall be delivered to Andrej Grubisic (GSFC - Code 699) by the need date of 2021/06/01.

The remaining items + inspection reports + material certificates shall be delivered to Andrej Grubisic (GSFC – Code 699) by the end of period of performance.

Government-Furnished Equipment and Government-Furnished Information

None

Place of Performance

- Mindrum Precision, Inc, Facilities in Rancho Cucamonga, CA

File details come from the government source that posted it. Updated .