This sources sought notice from the Department of Veterans Affairs seeks capabilities statements from preferably Service Disabled Veteran Owned Small Businesses to provide three arterial blood gas analyzers and three UPS backup power sources for the Biloxi, Mississippi campus. Responses are due by March 18, 2024 and must include the vendor's Unique Entity Identification number and any required certifications. The analyzers must be compatible with RapidComm data management software, have a Windows 10 operating system, two-step user authentication, touch screen operation, and provide results within 60 seconds while automatically printing and sending results to the data manager. Additional requirements include self-cleaning sample ports, bar code scanning, cartridge-based consumables with at least 28-day onboard life, and the ability to measure and report arterial blood gas, blood gas co-oximetry, and pleural fluid pH. Clinical training, installation, and validation of the instruments are also required.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUBJECT*
Blood Gas Analyzer
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 39531 |
| SOLICITATION NUMBER* |
| 36C25624Q0596 |
| RESPONSE DATE/TIME/ZONE |
| 03-18-2024 12pm CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339113 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Gulf Coast Veterans Healthcare System 400 Veterans Avenue Biloxi MS 39531
POINT OF CONTACT*
Contract Specialist Angela Kennedy angela.kennedy2@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
Gulf Coast Veterans Healthcare System
400 Veterans Avenue
Biloxi MS
| POSTAL CODE |
| 39531 |
Sources Sought Notice Sources Sought Notice
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
This is a SOURCES SOUGHT NOTICE ONLY This SOURCE SOUGHT NOTICE is for the purpose of Market Research. Response to this notice will be used for information and planning purposes. No proposals or quotes are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS or QUOTES and NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall NOT be construed as solicitation or as an obligation on the part of the Department of Veterans Affairs (VA). Responses to this notice is not a request to be added to a prospective bidders list or to receive a copy of the solicitation.
The Network Contracting Office (NCO) 16 is seeking preferably Service Disabled Veteran Owned Small Businesses capable of providing a Blood Gas Analyzer as per the draft Statement of Work below
See DRAFT Statement of Work below for detailed services.
The NAICS code is 339113, Medical & Surgical Instruments, Equipment, and Supplies and the Size Standard is 750 Employees. Responses must be received by no later than 12:00 p.m. Central Time, Monday, March 18, 2024. Responses shall be emailed to angela.kennedy2@va.gov Response shall contain Capabilities Statements to include Unique Entity Identification (UEI) number, and any qualifying certifications that may be required. Facsimile or Telephonic responses will not be accepted.
Note: All interested parties are reminded to be registered, active and verified in the following to be considered for Award.
· SAM:
SAM.gov | Home
· VETBIZ
Home · VetBiz Portal (va.gov)
· Vet 4212 (Veteran owned small Business are reminded of Reporting Requirements) VETS-4212 Federal Contractor Reporting | U.S. Department of Labor (dol.gov)
DRAFT STATEMENT OF WORK
Scope: Medical Service/ Respiratory Therapy section is requesting to purchase three (3) arterial blood gas analyzers with three (3) UPS standard 120V backup power sources for the Biloxi campus. Installation, training, and validation is included with purchase.
Specifications/Characteristics:
· The arterial blood gas analyzers must meet the following requirements:
· Must be compatible with RapidComm data management software
· Must have Microsoft Windows 10 operating system
· Two step user authentication process
· Touch screen operation
· Results available in 60 seconds, auto print of results, auto send results to data manager
· Sample: sufficient sample as small as one microliter, universal sample port, self-cleaning sample port, hands free automatic sample aspiration
· Bar code scanner for patient data, operator identification, quality control information
· Cartridge bases system: measurement, quality control, waste
· Measurement cartridge: initialization less than 30 minutes, 28-day onboard use life
· Quality control: independent automatic quality control cartridge, ability to schedule quality control at required intervals, three levels of automatic quality controls, auto repeat if quality control failure, ability to manually que quality control sample
· Routine scheduled automatic calibrations, auto repeat if calibration failure, ability to manually que system calibrations
· Integrated automatic clot and bubble checks, integrated automatic clot clearance function
· Manual interruption of calibration to allow for STAT sample analysis
· Must, at a minimum, measure and report arterial blood gas, blood gas co-oximetry, and pleural fluid pH (must be FDA approved to report these tests)
· Allow for key entry of ventilator settings and metrics
· Automated defenses to safeguard IT security
· UPS power surge protector
· Clinical training of staff
· Installation and validation of instruments
· Telephone support: 24/7 for life of equipment
Blood Gas Analyzer End of Document